Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
N Engl J Med ; 374(22): 2111-9, 2016 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-27248619

RESUMEN

BACKGROUND: Catheter-associated urinary tract infection (UTI) is a common device-associated infection in hospitals. Both technical factors--appropriate catheter use, aseptic insertion, and proper maintenance--and socioadaptive factors, such as cultural and behavioral changes in hospital units, are important in preventing catheter-associated UTI. METHODS: The national Comprehensive Unit-based Safety Program, funded by the Agency for Healthcare Research and Quality, aimed to reduce catheter-associated UTI in intensive care units (ICUs) and non-ICUs. The main program features were dissemination of information to sponsor organizations and hospitals, data collection, and guidance on key technical and socioadaptive factors in the prevention of catheter-associated UTI. Data on catheter use and catheter-associated UTI rates were collected during three phases: baseline (3 months), implementation (2 months), and sustainability (12 months). Multilevel negative binomial models were used to assess changes in catheter use and catheter-associated UTI rates. RESULTS: Data were obtained from 926 units (59.7% were non-ICUs, and 40.3% were ICUs) in 603 hospitals in 32 states, the District of Columbia, and Puerto Rico. The unadjusted catheter-associated UTI rate decreased overall from 2.82 to 2.19 infections per 1000 catheter-days. In an adjusted analysis, catheter-associated UTI rates decreased from 2.40 to 2.05 infections per 1000 catheter-days (incidence rate ratio, 0.86; 95% confidence interval [CI], 0.76 to 0.96; P=0.009). Among non-ICUs, catheter use decreased from 20.1% to 18.8% (incidence rate ratio, 0.93; 95% CI, 0.90 to 0.96; P<0.001) and catheter-associated UTI rates decreased from 2.28 to 1.54 infections per 1000 catheter-days (incidence rate ratio, 0.68; 95% CI, 0.56 to 0.82; P<0.001). Catheter use and catheter-associated UTI rates were largely unchanged in ICUs. Tests for heterogeneity (ICU vs. non-ICU) were significant for catheter use (P=0.004) and catheter-associated UTI rates (P=0.001). CONCLUSIONS: A national prevention program appears to reduce catheter use and catheter-associated UTI rates in non-ICUs. (Funded by the Agency for Healthcare Research and Quality.).


Asunto(s)
Infecciones Relacionadas con Catéteres/prevención & control , Infección Hospitalaria/prevención & control , Cateterismo Urinario/estadística & datos numéricos , Infecciones Urinarias/prevención & control , Infecciones Relacionadas con Catéteres/epidemiología , Infección Hospitalaria/epidemiología , Capacidad de Camas en Hospitales , Unidades Hospitalarias , Humanos , Incidencia , Modelos Estadísticos , Estados Unidos , Cateterismo Urinario/efectos adversos , Infecciones Urinarias/epidemiología
2.
Infect Control Hosp Epidemiol ; 35(1): 56-62, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24334799

RESUMEN

BACKGROUND: Several studies demonstrating that central line-associated bloodstream infections (CLABSIs) are preventable prompted a national initiative to reduce the incidence of these infections. METHODS: We conducted a collaborative cohort study to evaluate the impact of the national "On the CUSP: Stop BSI" program on CLABSI rates among participating adult intensive care units (ICUs). The program goal was to achieve a unit-level mean CLABSI rate of less than 1 case per 1,000 catheter-days using standardized definitions from the National Healthcare Safety Network. Multilevel Poisson regression modeling compared infection rates before, during, and up to 18 months after the intervention was implemented. RESULTS: A total of 1,071 ICUs from 44 states, the District of Columbia, and Puerto Rico, reporting 27,153 ICU-months and 4,454,324 catheter-days of data, were included in the analysis. The overall mean CLABSI rate significantly decreased from 1.96 cases per 1,000 catheter-days at baseline to 1.15 at 16-18 months after implementation. CLABSI rates decreased during all observation periods compared with baseline, with adjusted incidence rate ratios steadily decreasing to 0.57 (95% confidence intervals, 0.50-0.65) at 16-18 months after implementation. CONCLUSION: Coincident with the implementation of the national "On the CUSP: Stop BSI" program was a significant and sustained decrease in CLABSIs among a large and diverse cohort of ICUs, demonstrating an overall 43% decrease and suggesting the majority of ICUs in the United States can achieve additional reductions in CLABSI rates.


Asunto(s)
Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/prevención & control , Infección Hospitalaria/prevención & control , Unidades de Cuidados Intensivos , Adulto , Cateterismo Venoso Central/efectos adversos , Infección Hospitalaria/epidemiología , Humanos , Incidencia , Control de Infecciones/métodos , Evaluación de Programas y Proyectos de Salud , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA