Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(1): 64-70, 2020 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-32071465

RESUMEN

OBJECTIVE: To compare the clinical effects of ultrasonic subgingival debridement and ultrasonic subgingival debridement combined with manual root planing on severe periodontitis and then to investigate the necessity and significance of manual root planing. METHODS: Twenty-three patients with severe periodontitis participated in this split-mouth randomized-controlled clinical trial. Baseline examination and randomization were performed after supragingival scaling: each of the upper and lower jaws had a quadrant as the test group treated with ultrasonic subgingival debridement combined with manual root planing, whereas the other two quadrants were the control group treated with ultrasonic subgingival debridement. Treatment of each patient was at intervals of one week and completed in two visits. Clinical indicators concerning probing depth (PD), clinical attachment loss (CAL) and bleeding index (BI) were recorded at baseline and 1 month, 3 months, 6 months after treatment. RESULTS: There was no significant difference of periodontal indicators between the test group and the control group at baseline. Both the test group and control group resulted in significant improvement of PD, CAL and BI. One and three months after treatment, reduction of PD in the test group was higher than that in the control group [1 month: (2.13±1.31) mm vs. (1.79±1.33) mm, P<0.01; 3 months: (2.46±1.33) mm vs. (2.17±1.38) mm, P<0.01] and reduction of CAL in the test group was higher than that in the control group [1 month: (1.89±2.03) mm vs. (1.65±1.93) mm, P<0.01; 3 months: (2.03±2.05) mm vs. (1.83±1.97) mm, P<0.05]. Six months after treatment, PD in the test group and the control group decreased by (2.52±1.40) mm and (2.35±1.37) mm respectively, and the improvement in the test group was significantly better than that in the control group (P<0.01). CAL in the test group and the control group decreased by (1.89±2.14) mm and (1.77±2.00) mm respectively, and there was no statistical difference between the groups. There was no significant difference in the changes of BI between the two groups 1, 3 and 6 months after treatment. CONCLUSION: Ultrasonic subgingival debridement combined with manual root planing has more reduction in PD and CAL compared with ultrasonic subgingival debridement. Therefore, it is still necessary to use manual instruments for root planing following ultrasonic subgingival debridement.


Asunto(s)
Periodontitis , Ultrasonido , Desbridamiento , Raspado Dental , Humanos , Aplanamiento de la Raíz , Resultado del Tratamiento
3.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 55(2): 73-79, 2020 Feb 09.
Artículo en Chino | MEDLINE | ID: mdl-32074666

RESUMEN

Objective: To establish a quantitative three-dimensional method based on intraoral scan to evaluate the changes of soft tissue, and to evaluate the changes of supracrestal gingival thickness (SGT) in skeletal class Ⅲ patients induced by periodontal regenerative and corticotomy surgery (PRCS). Methods: Twenty-two systematically and periodontally healthy skeletal class Ⅲ patients (4 males and 18 females, aged between 19 and 35 years), who were in need of combined orthodontic-orthognathic treatment and referred to the Department of Periodontology from the Department of Orthodontics and the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology from January, 2018 to March, 2019, were collected in the study. The teeth involved were 112 anterior teeth (46 maxillary anterior teeth and 66 mandibular anterior teeth). PRCS in anterior tooth area was conducted before orthodontic decompensation. Probing depth (PD), bleeding index (BI) and keratinized gingiva width (KGW) were recorded before surgery and 6 months post-surgery. The intraoral digital impressions of maxillary and mandibular anterior teeth were obtained by 3-shape intraoral scanner before surgery and 6 months after surgery. The Standard Tessellation Language (STL) files were processed using Geomagic qualify 12.2 software to establish the soft tissue morphological measurement model, and to quantitatively analyze the changes of gingival thickness situated 1 to 2 mm apical to the free gingival margin on the median sagittal measurement plane. Results: Probing depth and bleeding index had no significant difference before and 6 months after operation (P>0.05). KGW in 6-month post-operation group [(5.18±2.32) mm] was significantly higher than that in pre-operation group [(4.22±1.43) mm] (P<0.05). Supracrestal gingival thickness situated 1 to 2 mm apical to the free gingival margin also significantly increased 6 months after surgery (P<0.05). The changes of gingival thickness situated 1 to 2 mm apical to the free gingival margin in the upper anterior area were (0.68±0.56) and (1.00±0.69) mm, respectively. The changes in the lower anterior area were (0.38±0.42) and (0.58±0.45) mm, respectively. The gingival changes of the upper anterior teeth were also significantly higher than those of the lower anterior teeth (P<0.01). Conclusions: The described quantitative measurement based on intraoral scan could be an effective method for quantitative evaluation of the changes of soft tissue. PRCS could safely increase the supracrestal gingival thickness as well as KGW in skeletal class Ⅲ patients who were in need of combined orthodontic-orthognathic treatment.


Asunto(s)
Encía/diagnóstico por imagen , Maloclusión de Angle Clase III , Procedimientos Quirúrgicos Orales , Adulto , Femenino , Humanos , Imagenología Tridimensional , Masculino , Maxilar , Adulto Joven
4.
Opt Express ; 23(9): 11183-94, 2015 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-25969214

RESUMEN

Black phosphorous (BP), the most thermodynamically stable allotrope of phosphorus, is a high-mobility layered semiconductor with direct band-gap determined by the number of layers from 0.3 eV (bulk) to 2.0 eV (single layer). Therefore, BP is considered as a natural candidate for broadband optical applications, particularly in the infrared (IR) and mid-IR part of the spectrum. The strong light-matter interaction, narrow direct band-gap, and wide range of tunable optical response make BP as a promising nonlinear optical material, particularly with great potentials for infrared and mid-infrared opto-electronics. Herein, we experimentally verified its broadband and enhanced saturable absorption of multi-layer BP (with a thickness of ~10 nm) by wide-band Z-scan measurement technique, and anticipated that multi-layer BPs could be developed as another new type of two-dimensional saturable absorber with operation bandwidth ranging from the visible (400 nm) towards mid-IR (at least 1930 nm). Our results might suggest that ultra-thin multi-layer BP films could be potentially developed as broadband ultra-fast photonics devices, such as passive Q-switcher, mode-locker, optical switcher etc.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...