Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Card Fail ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38851449

RESUMEN

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
Int J Infect Dis ; 142: 106989, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38428479

RESUMEN

OBJECTIVES: The empirical treatment of infective endocarditis is still debated. The aim of this study was to compare the impact of empirical treatment with antistaphylococcal penicillin (ASP) or cefazolin vs. other treatments in methicillin-susceptible Staphylococcus aureus (MSSA) endocarditis. METHODS: A post hoc analysis of a prospective cohort study of patients hospitalized in a French reference centre with MSSA endocarditis was conducted between 2013 and 2022. The primary outcome was the duration of bacteraemia under treatment. RESULTS: Of the 208 patients included, 101 patients (48.6%) were classified in the reference group (ASP or cefazolin) and 107 (52.4%) in the non-reference group. Empirical treatment with ASP/cefazolin was associated with a shorter duration of bacteraemia compared to other treatments (3.6 d vs. 4.6 d, P = 0.01). This difference was not corrected by the addition of an aminoglycoside (3.6 d vs. 4.7 d, P < 0.01). In multivariate analysis, empirical treatment with ASP/cefazolin was associated with a duration of bacteraemia ≤72 h (P = 0.02), whereas endocarditis on native valves (P = 0.01), and intracardiac abscess were associated with longer duration of bacteraemia (P = 0.01). CONCLUSIONS: Empirical treatment of endocarditis with ASP or Cefazolin is more effective than other treatments in MSSA endocarditis, even when the other treatments are combined with aminoglycosides.


Asunto(s)
Bacteriemia , Endocarditis Bacteriana , Endocarditis , Infecciones Estafilocócicas , Humanos , Cefazolina/uso terapéutico , Meticilina/farmacología , Meticilina/uso terapéutico , Estudios Prospectivos , Staphylococcus aureus , Estudios de Cohortes , Infecciones Estafilocócicas/tratamiento farmacológico , Antibacterianos/uso terapéutico , Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis/tratamiento farmacológico , Bacteriemia/tratamiento farmacológico
3.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34974497

RESUMEN

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Resultado del Tratamiento
4.
ESC Heart Fail ; 8(6): 5159-5167, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34494391

RESUMEN

AIMS: Despite regularly updated guidelines, there is still a delay in referral of advanced heart failure patients to mechanical circulatory support and transplant centres. We aimed to analyse characteristics and outcome of non-inotrope-dependent patients implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS: The ASSIST-ICD registry collected LVAD data in 19 centres in France between February 2006 and December 2016. We used data of patients in Interagency Registry for Mechanically Assisted Circulatory Support Classes 4-7. The primary endpoint was survival analysis. Predictors of mortality were searched with multivariable analyses. A total of 303 patients (mean age 61.0 ± 9.9 years, male sex 86.8%) were included in the present analysis. Ischaemic cardiomyopathy was the leading heart failure aetiology (64%), and bridge to transplantation was the main implantation strategy (56.1%). The overall likelihood of being alive while on LVAD support or having a transplant at 1, 2, 3, and 5 years was 66%, 61.7%, 58.7%, and 55.1%, respectively. Age [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.00-1.05; P = 0.02], a concomitant procedure (HR 2.32, 95% CI 1.52-3.53; P < 0.0001), and temporary mechanical right ventricular support during LVAD implantation (HR 2.94, 95% CI 1.49-5.77; P = 0.002) were the only independent variables associated with mortality. Heart failure medications before or after LVAD implantation were not associated with survival. CONCLUSION: Ambulatory heart failure patients displayed unsatisfactory survival rates after LVAD implantation. A better selection of patients who can benefit from LVAD may help improving outcomes.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Anciano , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Tasa de Supervivencia , Resultado del Tratamiento
5.
JACC Case Rep ; 3(3): 486-490, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34317564

RESUMEN

Intra-axial pumps are increasingly used to support cardiogenic shock. The occurrence of electrical storms in this setting is a rising issue, and data remain scarce about optimal management. We report the feasibility of ventricular tachycardia ablation in the presence of a recent surgically inserted Impella 5.0 device (Abiomed, Danvers, Massachusetts). (Level of Difficulty: Intermediate.).

6.
Am J Cardiol ; 146: 82-88, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33549526

RESUMEN

LVAD implantation in patients with a recently diagnosed cardiomyopathy has been poorly investigated. This work aims at describing the characteristics and outcomes of patients receiving a LVAD within 30 days following the diagnosis of cardiomyopathy. Patients from the ASSIST-ICD study was divided into recently and remotely diagnosed cardiomyopathy based on the time from initial diagnosis of cardiomyopathy to LVAD implantation using the cut point of 30 days. The primary end point of the study was all-cause mortality at 30-day and during follow-up. A total of 652 patients were included and followed during a median time of 9.1 (2.5 to 22.1) months. In this population, 117 (17.9%) had a recently diagnosed cardiomyopathy and had LVAD implantation after a median time of 15.0 (9.0 to 24.0) days following the diagnosis. This group of patients was significantly younger, with more ischemic cardiomyopathy, more sudden cardiac arrest (SCA) events at the time of the diagnosis and were more likely to receive temporary mechanical support before LVAD compared with the remotely diagnosed group. Postoperative in-hospital survival was similar in groups, but recently diagnosed patients had a better long-term survival after hospital discharge. SCA before LVAD and any cardiac surgery combined with LVAD implantation were identified as 2 independent predictors of postoperative mortality in recently diagnosed patients. In conclusion, rescue LVAD implantation for recently diagnosed severe cardiomyopathy is common in clinical practice. Such patients experience a relatively low postoperative mortality and have a better long-term survival compared with remotely diagnosed patients.


Asunto(s)
Cardiomiopatías/terapia , Corazón Auxiliar , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Femenino , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Diseño de Prótesis , Estudios Retrospectivos , Tasa de Supervivencia/tendencias
7.
Arch Cardiovasc Dis ; 113(11): 701-709, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32952086

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) implantation may be an attractive alternative therapeutic option for elderly patients with heart failure who are ineligible for heart transplantation. AIM: We aimed to describe the characteristics and outcomes of elderly patients (i.e. aged≥70 years) receiving an LVAD. METHODS: This observational study was conducted in 19 centres between 2006 and 2016. Patients were divided into two groups-younger (aged<70 years) and elderly (aged≥70 years), based on age at time of LVAD implantation. RESULTS: A total of 652 patients were included in the final analysis, and 74 patients (11.3%) were aged≥70 years at the time of LVAD implantation (maximal age 77.6 years). The proportion of elderly patients receiving an LVAD each year was constant, with a median of 10.6% (interquartile range 8.0-15.4%) per year, and all were implanted as destination therapy. Elderly and younger patients had similar durations of hospitalization in intensive care units and total lengths of hospital stays. Both age groups experienced similar rates of LVAD-related complications (i.e. stroke, bleeding, driveline infection and LVAD exchange), and the occurrence of LVAD complications did not impact survival in the elderly group compared with the younger group. Lastly, when compared with younger patients implanted as destination therapy, the elderly group also exhibited similar mid-term survival. CONCLUSION: This work strongly suggests that selected elderly adults can be scheduled for LVAD implantation.


Asunto(s)
Insuficiencia Cardíaca/terapia , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Factores de Edad , Anciano , Femenino , Francia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/mortalidad , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
8.
Eur J Cardiothorac Surg ; 58(6): 1175-1181, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830239

RESUMEN

OBJECTIVES: At our centre, the SynCardia temporary Total Artificial Heart (TAH-t) (SynCardia Systems, LLC, Tucson, AZ, USA) is used to provide long-term support for patients with biventricular failure as a bridge to a transplant. However, a heart transplant (HT) after such support remains challenging. The aim of this retrospective study was to assess the immediate and long-term results following an HT in the cohort of patients who had a TAH-t implant. METHODS: A total of 73 patients were implanted with the TAH-t between 1988 and 2019 in our centre. Of these 73 consecutive patients, 50 (68%) received an HT and are included in this retrospective analysis of prospectively collected data. RESULTS: In the selected cohort, in-hospital mortality after an HT was 10% (n = 5). The median intensive care unit stay was 33 days (range 5-278). The median hospital stay was 41 days (range 28-650). A partial or total pericardiectomy was performed during the HT procedure in 21 patients (42%) due to a severe pericardial reaction. Long-term survival rates after an HT at 5, 10 and 12 years were 79.1 ± 5.9% (n = 32), 76.5 ± 6.3% (n = 22) and 72.4 ± 7.1% (n = 12), respectively, which was similar to the long-term survival for a primary HT without TAH-t during the same period (n = 686). An HT performed within 3-6 months post-TAH-t implantation appeared to provide the best survival (P = 0.007). Eight (16%) patients required chronic dialysis during the subsequent follow-up period, with 3 patients requiring a kidney transplant. CONCLUSIONS: The long-term outcomes with the SynCardia TAH-t as a bridge to transplant in patients with severe biventricular failure are very encouraging. Our review noted that an HT following TAH-t can be technically challenging, especially in the case of a severe pericardial reaction, with potential pitfalls that should be recognized preoperatively.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Artificial , Insuficiencia Cardíaca/cirugía , Humanos , Estudios Retrospectivos
9.
Am J Cardiol ; 133: 81-88, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-32861423

RESUMEN

We aimed at characterizing the impact of low and high body mass index (BMI) on outcomes after left-ventricular assist device (LVAD) surgery and define the predictors of mortality in patients with abnormal BMI (low/high). This study was conducted in 19 centers from 2006 to 2016. Patients were divided based on their baseline BMI into 3 groups of BMI: low (BMI ≤18.5 kg/m²); normal (BMI = 18.5 to 24.99 kg/m²) and high (BMI ≥25 kg/m²) (including overweight (BMI = 25 to 29.99 kg/m²), and obesity (BMI ≥30 Kg/m²)). Among 652 patients, 29 (4.4%), 279 (42.8%) and 344 (52.8%) had a low-, normal-, and high BMI, respectively. Patients with high BMI were significantly more likely men, with more co-morbidities and more history of ventricular/supra-ventricular arrhythmias before LVAD implantation. Patients with abnormal BMI had significantly lower survival than those with normal BMI. Notably, those with low BMI experienced the worst survival whereas overweight or obese patients had similar survival. Four predictors of mortality for LVAD candidates with abnormal BMI were defined: total bilirubin ≥16 µmol/L before LVAD, hypertension, destination therapy, and cardiac surgery with LVAD. Depending on the number of predictor per patients, those with abnormal BMI may be divided in 3 groups of 1-year mortality risk, i.e., low (0 to 1 predictor: 29% and 31%), intermediate (2 to 3 predictors, 51% and 52%, respectively), and high (4 predictors: 83%). In conclusion, LVAD recipients with abnormal BMI experience lower survival, especially underweight patients. Four predictors of mortality have been identified for LVAD population with abnormal BMI, differentiating those a low-, intermediate-, and high risks of death.


Asunto(s)
Índice de Masa Corporal , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Obesidad/complicaciones , Delgadez/complicaciones , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Obesidad/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Delgadez/mortalidad , Resultado del Tratamiento
10.
Eur J Cardiothorac Surg ; 58(1): 112-120, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32298439

RESUMEN

OBJECTIVES: Our goal was to provide a picture of left ventricular assist device (LVAD) activity in France between 2007 and 2016 based on the multicentric ASSIST-ICD registry. METHODS: We retrospectively collected 136 variables including in-hospital data, follow-up survival rates and adverse events from 671 LVAD recipients at 20 out of 24 LVAD implant centres in France. The average follow-up time was 1.2 years (standard deviation: 1.4); the total follow-up time was 807.5 patient-years. RESULTS: The included devices were the HeartMate II®, HeartWare LVAS® or Jarvik 2000®. The overall likelihood of being alive while on LVAD support or having a transplant (primary end point) at 1, 2, 3 and 5 years postimplantation was 65.2%, 59.7%, 55.9% and 47.7%, respectively, given a cumulative incidence of 29.2% of receiving a transplant at year 5. At implantation, 21.5% of patients were on extracorporeal life support. The overall rate of cardiogenic shock at implantation was 53%. The major complications were driveline infection (26.1%), pump pocket or cannula infection (12.6%), LVAD thrombosis (12.2%), ischaemic (12.8%) or haemorrhagic stroke (5.4%; all strokes 18.2%), non-cerebral haemorrhage (9.1%) and LVAD exchange (5.2%). The primary end point (survival) was stratified by age at surgery and by the type of device used, with inference from baseline profiles. The primary end point combined with an absence of complications (secondary end point) was also stratified by device type. CONCLUSIONS: The ASSIST-ICD registry provides a real-life picture of LVAD use in 20 of the 24 implant centres in France. Despite older average age and a higher proportion of patients chosen for destination therapy, survival rates improved compared to those in previous national registry results. This LVAD registry contrasts with other international registries because patients with implants have more severe disease, and the national policy for graft attribution is distinct. We recommend referring patients for LVAD earlier and suggest a discussion of the optimal timing of a transplant for bridged patients (more dismal results after the second year of support?).


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Francia/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
12.
Am J Cardiol ; 125(9): 1421-1428, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32145895

RESUMEN

The impact of uncommon etiology cardiomyopathies on Left-ventricular assist device (LVAD)-recipient outcomes is not very well known. This study aimed to characterize patients with uncommon cardiomyopathy etiologies and examine the outcomes between uncommon and ischemic/idiopathic dilated cardiomyopathy. This observational study was conducted in 19 centers between 2006 and 2016. Baseline characteristics and outcomes of patients with uncommon etiology were compared to patients with idiopathic dilated/ischemic cardiomyopathies. Among 652 LVAD-recipients included, a total of 590 (90.5%) patients were classified as ischemic/idiopathic and 62 (9.5%) patients were classified in the "uncommon etiologies" group. Main uncommon etiologies were: hypertrophic (n = 12(19%)); cancer therapeutics-related cardiac dysfunction (CTRCD) (n = 12(19%)); myocarditis (n = 11(18%)); valvulopathy (n = 9(15%)) and others (n = 18(29%)). Patients with uncommon etiologies were significantly younger with more female and presented less co-morbidities. Additionally, patients with uncommon cardiomyopathies were less implanted as destination therapy compared with ischemic/idiopathic group (29% vs 38.8%). During a follow-up period of 9.1 months, both groups experienced similar survival. However, subgroup of hypertrophic/valvular cardiomyopathies and CTRCD had significantly higher mortality compared to the ischemic/idiopathic or myocarditis/others cardiomyopathies. Conversely, patients with myocarditis/others etiologies experienced a better survival. Indeed, the 12-months survival in the myocarditis/others; ischemic/idiopathic and hypertrophic/CTRCD/valvulopathy group were 77%; 65%, and 46% respectively. In conclusion, LVAD-recipients with hypertrophic cardiomyopathy, valvular heart disease and CTRCD experienced the higher mortality rate.


Asunto(s)
Cardiomiopatía Dilatada/cirugía , Cardiomiopatía Hipertrófica/cirugía , Corazón Auxiliar , Isquemia Miocárdica/cirugía , Adulto , Anciano , Cardiomiopatía Dilatada/etiología , Cardiomiopatía Hipertrófica/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Estudios Retrospectivos , Resultado del Tratamiento
13.
Heart Rhythm ; 16(10): 1506-1512, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31255846

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) can occur after continuous flow left ventricular assist device (LVAD) implantation as a single arrhythmic event or as electrical storm (ES) with multiple repetitive VA episodes. OBJECTIVE: We aimed at analyzing the incidence, predictors, and clinical impact of ES in LVAD recipients. METHODS: Patients analyzed were those included in the multicenter ASSIST-ICD observational study. ES was consensually defined as occurrence of ≥3 separate episodes of sustained VAs within a 24-hour interval. RESULTS: Of 652 patients with an LVAD, 61 (9%) presented ES during a median follow-up period of 9.1 (interquartile range [IQR] 2.5-22.1) months. The first ES occurred after 17 (IQR 4.0-56.2) days post LVAD implantation, most of them during the first month after the device implantation (63%). The incidence then tended to decrease during the initial years of follow-up and increased again after the third year post LVAD implantation. History of VAs before LVAD implantation and heart failure duration > 84 months were independent predictors of ES. The occurrence of ES was associated with an increased early mortality since 20 patients (33%) died within the first 2 weeks of ES. Twenty-two patients (36.1%) presented at least 1 recurrence of ES, occurring 43.0 (IQR 8.0-69.0) days after the initial ES. Patients experiencing ES had a significantly lower 1-year survival rate than did those free from ES (log-rank, P = .039). CONCLUSION: There is a significant incidence of ES in patients with an LVAD. The short-term mortality after ES is high, and one-third of patients will die within 15 days. Whether radiofrequency ablation of arrhythmias improves outcomes would require further studies.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Taquicardia Ventricular/etiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/mortalidad , Adulto , Factores de Edad , Anciano , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Cadenas de Markov , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Tasa de Supervivencia , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/fisiopatología
14.
Clin Infect Dis ; 69(9): 1605-1612, 2019 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-30615098

RESUMEN

BACKGROUND: In the management of infective endocarditis (IE), the presence of extracardiac complications has an influence on both diagnosis and treatment. Current guidelines suggest that systematic thoracoabdominal-pelvic computed tomography (TAP-CT) may be helpful. Our objective was to describe how systematic TAP-CT affects the diagnosis and the management of IE. METHODS: In this multicenter cohort study, between January 2013 and July 2016 we included consecutive patients who had definite or possible IE according to the Duke modified criteria, validated by endocarditis teams. We analyzed whether the Duke classification and therapeutic management were modified regarding the presence or the absence of IE-related lesion on CT and investigated the tolerance of this examination. RESULTS: Of the 522 patients included in this study, 217 (41.6%) had 1 or more IE-related lesions. On the basis of CT results in asymptomatic patients, diagnostic classification was upgraded from possible endocarditis to definite endocarditis for only 4 cases (0.8%). The presence of IE-related lesions on CT did not modify the duration of antibiotic treatment (P = .55), nor the decision of surgical treatment (P = .39). Specific treatment of the lesion was necessary in 42 patients (8.0%), but only 9 of these lesions (1.9%) were asymptomatic and diagnosed only on the TAP-CT. Acute kidney injury (AKI) within 5 days of CT was observed in 78 patients (14.9%). CONCLUSIONS: The TAP-CT findings slightly affected diagnosis and treatment of IE in a very small proportion of asymptomatic patients. Furthermore, contrast media should be used with caution because of the high risk of AKI.


Asunto(s)
Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis/diagnóstico por imagen , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X/métodos , Lesión Renal Aguda/diagnóstico por imagen , Adulto , Anciano , Estudios de Cohortes , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
15.
JACC Clin Electrophysiol ; 4(9): 1166-1175, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30236390

RESUMEN

OBJECTIVES: This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. BACKGROUND: The arrhythmic risk and need for ICD in patients implanted with an LVAD are not very well known. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Late VAs were defined as sustained ventricular tachycardia or fibrillation occurring >30 days post-LVAD implantation, without acute reversible cause and requiring appropriate ICD therapy, external electrical shock, or medical therapy. RESULTS: Among 659 LVAD recipients, 494 (median 58.9 years of age; mean left ventricular ejection fraction 20.7 ± 7.4%; 73.1% HeartMate II, 18.6% HeartWare, 8.3% Jarvik 2000) were discharged alive from hospital and included in the final analysis. Late VAs occurred in 133 (26.9%) patients. Multivariable analysis identified 6 independent predictors of late VAs: VAs before LVAD implantation, atrial fibrillation before LVAD implantation, idiopathic etiology of the cardiomyopathy, heart failure duration >12 months, early VAs (<30 days post-LVAD), and no angiotensin-converting enzyme inhibitors during follow-up. The "VT-LVAD score" was created, identifying 4 risk groups: low (score 0 to 1), intermediate (score 2 to 4), high (score 5 to 6), and very high (score 7 to 10). The rates of VAs at 1 year were 0.0%, 8.0%, 31.0% and 55.0%, respectively. CONCLUSIONS: Late VAs are common after LVAD implantation. The VT-LVAD score may help to identify patients at risk of late VAs and guide ICD indications in previously nonimplanted patients. (Determination of Risk Factors of Ventricular Arrhythmias [VAs] after implantation of continuous flow left ventricular assist device with continuous flow left ventricular assist device [CF-LVAD] [ASSIST-ICD]; NCT02873169).


Asunto(s)
Arritmias Cardíacas , Desfibriladores Implantables , Corazón Auxiliar/efectos adversos , Anciano , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
16.
Circulation ; 130(23): 2012-20, 2014 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-25355912

RESUMEN

BACKGROUND: Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. METHODS AND RESULTS: Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7-94.7) for the whole cohort and 79.8% (95% CI, 71.2-89.4) and 94.0% (95% CI, 90.3-97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7-73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4-13.6). CONCLUSIONS: Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Animales , Bioprótesis/efectos adversos , Bovinos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Unidades de Cuidados Intensivos/estadística & datos numéricos , Estimación de Kaplan-Meier , Tiempo de Internación/estadística & datos numéricos , Masculino , Neoplasias/mortalidad , Modelos de Riesgos Proporcionales , Reoperación/mortalidad , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad
17.
ASAIO J ; 60(2): 140-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24577368

RESUMEN

Hemodynamic performances comparisons between different types of left ventricular assist devices (LVADs) remain difficult in a clinical context. The aim of this study was to create an experimental model to assess and compare two types of LVAD under hemodynamic conditions that simulated physical effort and pulmonary hypertension. An experimental mock circulatory system was created to simulate the systemic and pulmonary circulations and consisted of pulsatile left and right cardiac simulators (cardiowest pump), air/water tanks to model compliances, and tubes to model the venous and arterial resistances. Two types of continuous-flow ventricular assist devices were connected to this pulsated model: an axial flow pump, Heartmate II (HTM II), and a centrifugal pump, VentrAssist (VTA). The hemodynamic conditions at rest and during exercise were replicated. Mean aortic pressures were not significantly different at rest and during effort but mean flow under maximum pump speed was higher with HTM II (13 L vs. 10 L, p = 0.02). Left atrial pressure was lower at rest and during effort for the HTM II (11 mm Hg vs. 3 mm Hg, p = 0.02 and 9 mm Hg vs. 2 mm Hg, p = 0.008) than with the VTA, but with greater risk of left-ventricle suck-down for the axial flow. Power consumption for a similar flow was lower with the VTA during rest (4.7 W vs. 6.9 W, p = 0.002) and during effort (4.3 W vs. 6.6 W, p = 0.008). In case of high pulmonary vascular resistance with preserved right ventricular function, lower right ventricular pressure was obtained with HTM II (21 mm Hg vs. 28 mm Hg, p = 0.03). Observed results are in favor of a better discharge of the left and right cavities with the HTM II compared to the VTA yet with a higher risk of left cavity collapse occurrence.


Asunto(s)
Corazón Auxiliar , Hemodinámica/fisiología , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Pulsátil/fisiología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...