Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.609
Filtrar
1.
Nat Commun ; 15(1): 5653, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38969628

RESUMEN

Rubble pile asteroids are widely understood to be composed of reaccumulated debris following a catastrophic collision between asteroids in the main asteroid belt, where each disruption can make a family of new asteroids. Near-Earth asteroids Ryugu and Bennu have been linked to collisional families in the main asteroid belt, but surface age analyses of each asteroid suggest these bodies are substantially younger than their putative families. Here we show, through a coupled collisional and dynamical evolution of members of these families, that neither asteroid was likely to have been created at the same time as the original family breakups, but rather are likely remnants of later disruptions of original family members, making them second, or later, generation remnants. Our model finds about 80% and 60% of asteroids currently being delivered to near-Earth orbits from the respective families of New Polana and Eulalia are second or later generation. These asteroids delivered today in the 0.5-1 km size range have median ages since their last disruption that are substantially younger than the family age, reconciling their measured crater retention ages with membership in these families.

3.
Phys Rev E ; 109(5-2): 055201, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38907485

RESUMEN

We provide analytic expressions for the effective Coulomb logarithm for inverse bremsstrahlung absorption which predict significant corrections to the Langdon effect and overall absorption rate compared to previous estimates. The calculation of the collisional absorption rate of laser energy in a plasma by the inverse bremsstrahlung mechanism usually makes the approximation of a constant Coulomb logarithm. We dispense with this approximation and instead take into account the velocity dependence of the Coulomb logarithm, leading to a more accurate expression for the absorption rate valid in both classical and quantum conditions. In contrast to previous work, the laser intensity enters into the Coulomb logarithm. In most laser-plasma interactions the electron distribution function is super-Gaussian [Langdon, Phys. Rev. Lett. 44, 575 (1980)0031-900710.1103/PhysRevLett.44.575], and we find the absorption rate under these conditions is increased by as much as ≈30% compared to previous estimates at low density. In many cases of interest the correction to Langdon's predicted reduction in absorption is large; for example at Z=6 and T_{e}=400eV the Langdon prediction for the absorption is in error by a factor of ≈2. However, we also account for the additional effect of plasma screening, which predicts a reduction in absorption by a similar amount (up to ≈30%). These two effects compete to determine the overall absorption, which may be increased or decreased, depending on the conditions. The corrections can be incorporated into radiation-hydrodynamics simulation codes by replacing the familiar Coulomb logarithm with an analytic expression which depends on the super-Gaussian order "M" and the screening length.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38864156

RESUMEN

PURPOSE: The purpose of this pilot cross-sectional study was to compare the operating room (OR) efficiency and intraoperative staff task load when performing individualised versus off-the-shelf (OTS) total knee arthroplasty (TKA). METHODS: A consecutive series of 28 patients randomised (1:1) to receive either OTS TKA or individualised TKA were included. The OR staff workload was assessed with the NASA Task Load Index (TLX), a subjective grading system assessing mental demand, physical demand, temporal demand, performance, effort and frustration on a scale from 0 (very low) to 20 (very high). The time for patient preparation, surgical time, closure and total OR time was recorded to assess OR efficiency. Effect sizes of differences between OTS and individualised TKA were expressed as mean differences (MDs) with 95% confidence intervals (CIs). RESULTS: Patients in both cohorts were similar in age (OTS vs. individualised TKA (median [IQR]), 67 [63-76] vs. 71 [68-79]; p = 0.207) and body mass index (BMI) (29 [24-33] vs. 29 [26-31]; p = 0.807), and there were no significant differences in other preoperative characteristics. The OR staff perceived individualised TKA as less demanding than OTS TKA: Individualised TKA was rated significantly better across the six domains of the NASA TLX: mental demand by 5.6 points, physical demand by 6.3 points, temporal demand by 5.3 points, performance by 3.6 points, effort by 5.9 points and frustration by 5.8 points. Individualised TKA resulted in statistically significantly shorter mean total OR time (MD, 10 min; p = 0.018). CONCLUSION: The staff in the OR found that individualised TKA is less mentally, physically and temporally demanding than OTS TKA. The average total time spent in the OR during individualised TKA is 10 min less than during OTS TKA. CLINICAL TRIAL REGISTRATION: This study constitutes a part of a larger registered randomised controlled trial comparing patient satisfaction following OTS versus individualised TKA (NCT04460989). LEVEL OF EVIDENCE: Level III.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38864165

RESUMEN

PURPOSE: The purpose of this study was to compare postoperative patellar tilt at 4 months follow-up in a consecutive series of randomised patients that received individualised or off-the-shelf (OTS) primary total knee arthroplasty (TKA). The hypothesis was that patellar tilt would be lower and less variable in patients who received individualised TKA compared to patients who received OTS TKA. METHODS: A consecutive series of 385 patients randomised (1:1) to receive either OTS TKA or individualised TKA were analysed. Pre- and postoperative radiographs at 4 months were obtained of weight-bearing long leg, anterior-posterior and lateral knee views and a skyline view at 30° of flexion. Postoperative patellar tilt was measured between the anterior femoral line and patellar resection surface (ß) and the anterior femoral line and mediolateral patellar axis (σ). Postoperative patellar tilt (absolute value) was compared between the individualised and OTS TKA groups based on preoperative phenotypes of their femoral mechanical angle, tibial mechanical angle and hip-knee-ankle angle. Variability in postoperative patellar tilt was compared using the 95% confidence intervals (CIs). RESULTS: Comparisons of baseline patient characteristics revealed no difference between the individualised and OTS TKA groups. Comparison of absolute postoperative patellar tilt revealed significant differences between individualised and OTS TKA (|ß|, 1.0° ± 1.0° and 2.5° ± 2.2°, respectively, p < 0.001; |σ|, 1.7° ± 1.6° and 2.8° ± 2.3°, respectively, p < 0.001). The 95% CI of postoperative patellar tilt (|ß|) was narrower in patients that received individualised compared to OTS TKA (0.0° to 3.8° and 0.1° to 8.3°, respectively), irrespective of their preoperative phenotype. CONCLUSION: Patients who underwent individualised TKA had lower and less variable postoperative patellar tilt than those with OTS TKA, irrespective of preoperative phenotype. Individualised TKA allows the decoupling of the tibiofemoral and patellofemoral joints, replicating anatomical trochlear orientation and improving patellar tilt, which could facilitate better clinical outcomes. CLINICAL TRIAL REGISTRATION: This study constitutes a part of a larger registered randomised controlled trial comparing patient satisfaction following OTS versus individualised TKA (NCT04460989). LEVEL OF EVIDENCE: Level II.

6.
Surg Endosc ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858248

RESUMEN

INTRODUCTION: Despite the advancements in technology and organized training for surgeons in laparoscopic surgery, the persistent challenge of not being able to feel the resistance and characteristics of the tissue, including pulsations, remains unmet. A recently developed grasper (Optigrip®) with real time haptic feedback, based on photonic technology, aims to address this issue by restoring the tactile sensation for surgeons. The key question is whether pulsations can be detected and at what minimal size level they become clinical significant. METHODS: To simulate arterial conditions during laparoscopic procedures, four different silicone tubes were created, representing the most prevalent arteries. These tubes were connected to a validated pressure system, generating a natural pulse ranging between 80 and 120 mm Hg. One control tube without pressure was added. The surgeons had to grasp these tubes blindly with the conventional grasper or the haptic feedback grasper in a randomized order. They then indicated whether they felt the pressure or not and the percentage of correct answers was calculated. RESULTS: The haptic grasper successfully detected 96% of all pulsations, while the conventional grasper could only detect 6%. When considering the size of the arteries, the Optigrip® identified pulsations in 100% the 4 and 5 mm arteries and 92% of the smallest arteries. The conventional grasper was only able to feel the smallest arteries in 8%. These differences were highly significant (p < 0.0001). CONCLUSION: This study demonstrated that the newly developed haptic feedback grasper enables detection of arterial pulsations during laparoscopy, filling an important absence in tactile perception within laparoscopic surgery.

7.
Nat Commun ; 15(1): 4423, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38789438

RESUMEN

Density dependence is a fundamental ecological process. In particular, animal habitat selection and social behavior often affect fitness in a density-dependent manner. The Ideal Free Distribution (IFD) and niche variation hypothesis (NVH) present distinct predictions associated with Optimal Foraging Theory about how the effect of habitat selection on fitness varies with population density. Using caribou (Rangifer tarandus) in Canada as a model system, we test competing hypotheses about how habitat specialization, social behavior, and annual reproductive success (co)vary across a population density gradient. Within a behavioral reaction norm framework, we estimate repeatability, behavioral plasticity, and covariance among social behavior and habitat selection to investigate the adaptive value of sociality and habitat selection. In support of NVH, but not the IFD, we find that at high density habitat specialists had higher annual reproductive success than generalists, but were also less social than generalists, suggesting the possibility that specialists were less social to avoid competition. Our study supports niche variation as a mechanism for density-dependent habitat specialization.


Asunto(s)
Ecosistema , Densidad de Población , Conducta Social , Animales , Reno/fisiología , Canadá , Reproducción/fisiología , Conducta Animal/fisiología , Femenino , Masculino
9.
EFORT Open Rev ; 9(4): 264-275, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38579748

RESUMEN

Purpose: to systematically review comparative studies reporting revision rates, clinical outcomes, or radiographic outcomes of total hip arthroplasty (THA) using collared versus collarless conventional-length uncemented hydroxyapatite (HA)-coated stems. Methods: In adherence with PRISMA guidelines, a literature search was performed on Medline, Embase, and Scopus. Comparative clinical studies were eligible if they reported outcomes of collared versus collarless uncemented HA-coated stems for primary THA. Two reviewers screened titles, abstracts, and full-texts to determine eligibility; then performed data extraction; and assessed the quality of studies according to Joanna Briggs Institute (JBI) checklist. Results: The search returned 972 records, 486 were duplicates, and 479 were excluded after title/abstract/full-text screening. Three further studies were included from the references of eligible studies and from discussions with subject matter experts, resulting in 11 included studies. The JBI checklist indicated six studies scored ≥7 points and four studies ≥4 points. Pooled data revealed collared stems had significantly lower revision rates (OR = 0.45; 95% CI = 0.31-0.64) and subsidence (MD = -1 mm; 95% CI = -1.6--0.3), but no significant difference in intraoperative complication rates (OR = 0.94; 95% CI = 0.67-1.32) in the short term to mid-term. Unpooled data indicated that collared stems provide equivalent survival, equivalent or better outcomes, and equivalent or lower complication rates. Conclusion: In comparative studies, collared stems have lower revision rates than collarless stems, as well as equivalent or better clinical and radiographic outcomes. Differences could be due to a protective effect that the collar offers against subsidence, particularly in undersized or misaligned stems. Further studies are warranted to confirm long-term results and better understand differences between registry data and clinical studies.

10.
Clin Shoulder Elb ; 27(2): 229-236, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556916

RESUMEN

Eponymization serves as a means of paying tribute to individuals who have made significant contributions to our culture. Each eponym is often linked with a story for everyone to discover. To aid in the retention of these stories, this review offers readers an overview of the individuals behind the eponymous terms, as well as their original descriptions, within the context of acromioclavicular joint pathology and orthopaedic surgery.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38467182

RESUMEN

BACKGROUND: The extent of measurement errors of statistical shape models that predict native glenoid width based on glenoid height to subsequently determine the amount of anterior glenoid bone loss is unclear. Therefore, the aim of this study was to (1) create a statistical shape model based on glenoid height and width measured on 3-dimensional computed tomography (3D-CT) and determine the accuracy through measurement errors and (2) determine measurement errors of existing 3D-CT statistical shape models. MATERIALS AND METHODS: A retrospective cross-sectional study included all consecutive patients who underwent CT imaging before undergoing primary surgical treatment of traumatic anterior shoulder dislocation between 2007 and 2022 at the Tohoku University Hospital and affiliated hospitals. Patients were included when instability was unilateral and CT scans of both the injured and contralateral uninjured shoulder were available. 3D segmentations were created and glenoid height and width of the injured and contralateral uninjured side (gold standard) were measured. Accuracy was determined through measurement errors, which were defined as a percentage error deviation from native glenoid width (contralateral uninjured glenoid), calculated as follows: measurement error = [(estimated glenoid width with a statistical shape model - native glenoid width) / native glenoid width] × 100%. A linear regression analysis was performed to create a statistical shape model based on glenoid height according to the formula: native glenoid width = a × glenoid height + b. RESULTS: The diagnosis and procedure codes identified 105 patients, of which 69 (66%) were eligible for inclusion. Glenoid height demonstrated a very strong correlation (r = 0.80) with native glenoid width. The linear regression formula based on this cohort was as follows: native glenoid width = 0.75 × glenoid height - 0.61, and it demonstrated an absolute average measurement error of 5% ± 4%. The formulas by Giles et al, Chen et al and Rayes et al demonstrated absolute average measurement errors of 10% ± 7%, 6% ± 5%, and 9% ± 6%, respectively. CONCLUSION: Statistical shape models that estimate native glenoid width based on glenoid height demonstrate unacceptable measurement errors, despite a high correlation. Therefore, great caution is advised when using these models to determine glenoid bone loss percentage. To minimize errors caused by morphologic differences, preference goes to methods that use the contralateral side as reference.

12.
J Orthop Res ; 42(8): 1641-1652, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38465730

RESUMEN

In unstable shoulders, excessive anteroinferior position of the humeral head relative to the glenoid can lead to a dislocation. Measuring humeral head position could therefore be valuable in quantifying shoulder laxity. The aim of this study was to measure (1) position of the humeral head relative to the glenoid and (2) joint space thickness during passive motion in unstable shoulders caused by traumatic anterior dislocations and in contralateral uninjured shoulders. A prospective cross-sectional CT-study was performed in patients with unilateral anterior shoulder instability. Patients underwent CT scanning of both injured and uninjured side in supine position (0° abduction and 0° external rotation) and in 60°, 90°, and 120° of abduction with 90° of external rotation without an external load. Subsequently, 3D virtual models were created of the humerus and the scapula to create a glenoid coordinate system to identify poster-anterior, inferior-superior, and lateral-medial position of the humeral head relative to the glenoid. Joint space thickness was defined as the average distance between the subchondral bone surfaces of the humeral head and glenoid. Fifteen consecutive patients were included. In supine position, the humeral head was positioned more anteriorly (p = 0.004), inferiorly (p = 0.019), and laterally (p = 0.021) in the injured compared to the uninjured shoulder. No differences were observed in any of the other positions. A joint-space thickness map, showing the bone-to-bone distances, identified the Hill-Sachs lesion footprint on the glenoid surface in external rotation and abduction, but no differences on average joint space thickness were observed in any position.


Asunto(s)
Cabeza Humeral , Imagenología Tridimensional , Luxación del Hombro , Tomografía Computarizada por Rayos X , Humanos , Luxación del Hombro/diagnóstico por imagen , Luxación del Hombro/fisiopatología , Masculino , Adulto , Cabeza Humeral/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven , Estudios Transversales , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/fisiopatología , Inestabilidad de la Articulación/etiología
13.
Diabetes Res Clin Pract ; 208: 111124, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309533

RESUMEN

AIMS: The diagnosis of cystic fibrosis-related diabetes (CFRD) faces several challenges. We propose a novel screening algorithm to alleviate the burden of cystic fibrosis (CF). METHODS: Through a retrospective cross-sectional single-centre study, HbA1c and HOMA2 indices were assessed in multiple models as alternative diagnostic tools from OGTT data. We sought to establish specific thresholds for CFRD screening with oral glucose tolerance test (OGTT) as gold standard. We evaluated various straightforward or sequential approaches, in terms of diagnostic accuracy while also quantify the potential reduction in OGTTs through these different methods. RESULTS: HOMA indices were recovered in 72 patients. We devised a composite index that combines HbA1c and HOMA-B: Diabetes Predicting Index in cystic fibrosis (DIPIc) = (HbA1c(%) × 3.455) - (HOMA-B(%) ×  0.020) - 19.294. This index yields the highest screening accuracy according to receiver-operating characteristics curves. Using a stepwise algorithm that incorporates DIPIc decreases the requirement for annual OGTTs. A CFRD exclusion cutoff less than -1.7445 (sensitivity 98 %), in conjunction with a CFRD diagnostic threshold greater than 0.4543 (specificity 98 %) allows for 71 % OGTT sparing. CONCLUSION: The composite index DIPIc is a suitable, less invasive screening method for CFRD, which enables to avoid many OGTTs.


Asunto(s)
Fibrosis Quística , Diabetes Mellitus , Intolerancia a la Glucosa , Humanos , Prueba de Tolerancia a la Glucosa , Hemoglobina Glucada , Fibrosis Quística/complicaciones , Fibrosis Quística/diagnóstico , Glucemia , Estudios Retrospectivos , Estudios Transversales , Diabetes Mellitus/diagnóstico , Intolerancia a la Glucosa/diagnóstico
16.
JBJS Rev ; 12(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38181107

RESUMEN

BACKGROUND: The treatment of simple elbow dislocations (SEDs) has become more functional last decade with a tendency to shorter immobilization of the elbow, whereas simultaneously, surgical stabilization has been promoted by some authors. The primary aim of this study was to systematically review the literature and analyze the outcomes and complications of different treatment options for acute and persistent SEDs, including operative and nonoperative treatments with varying immobilization periods. METHODS: A literature search was performed based on the online medical databases MEDLINE, Embase, and the Cochrane databases. Articles presenting patients with a SED were eligible for inclusion. When an SED persists for >3 weeks, it is categorized as persistent. Various outcome measures were assessed, including the range of motion (ROM), patient-reported outcome measures, and complication rates. To get insight into the severity of complications, all complications were categorized as minor or major. The Methodological Index for Nonrandomized Studies was used to assess the methodological quality of nonrandomized studies. The risk of bias in the randomized studies was assessed with the Cochrane risk-of-bias tool. RESULTS: A total of 37 articles were included with 1,081 dislocated elbows (1,078 patients). A fair quality of evidence was seen for the nonrandomized studies and a low risk of bias for the randomized study. Nonoperative treatment was administered to 710 elbows, with 244 elbows treated with early mobilization, 239 with 1- to 3-week immobilization, and 163 with ≥3-week immobilization. These groups showed a ROM flexion-extension arc (ROM F/E) of 137, 129, and 131°, respectively. Surgical treatment as open reduction and ligament repair or reconstruction was performed in 228 elbows and showed a ROM F/E of 128°. All persistent SEDs were treated surgically and showed a ROM F/E of 90°. CONCLUSION: The early mobilization treatment showed the most consistent satisfactory outcomes in the literature compared with the other treatment options. Nevertheless, there remains ambiguity regarding which patients would benefit more from surgery than nonoperative treatment. LEVEL OF EVIDENCE: Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Articulación del Codo , Luxaciones Articulares , Humanos , Codo , Articulación del Codo/cirugía , Resultado del Tratamiento , Ambulación Precoz , Luxaciones Articulares/cirugía
18.
Clin Shoulder Elb ; 27(1): 88-107, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38147872

RESUMEN

The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

19.
J Shoulder Elbow Surg ; 33(1): 145-155, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37689102

RESUMEN

BACKGROUND: Overloading of the elbow joint prosthesis following total elbow arthroplasty can lead to implant failure. Joint moments during daily activities are not well contextualized for a prosthesis's failure limits, and the effect of the current postoperative instruction on elbow joint loading is unclear. This study investigates the difference in elbow joint moments between simulated daily tasks and between flexion-extension, pronation-supination, and varus-valgus movement directions. Additionally, the effect of the current postoperative instruction on elbow joint load is examined. METHODS: Nine healthy participants (age 45.8 ± 17 years, 3 males) performed 8 tasks; driving a car, opening a door, rising from a chair, lifting, sliding, combing hair, drinking, emptying cup, without and with the instruction "not lifting more than 1 kg." Upper limb kinematics and hand contact forces were measured. Elbow joint angles and net moments were analyzed using inverse dynamic analysis, where the net moments are estimated from movement data and external forces. RESULTS: Peak elbow joint moments differed significantly between tasks (P < .01) and movement directions (P < .01). The most and least demanding tasks were, rising from a chair (13.4 Nm extension, 5.0 Nm supination, and 15.2 Nm valgus) and sliding (4.3 Nm flexion, 1.7 Nm supination, and 2.6 Nm varus). Net moments were significantly reduced after instruction only in the chair task (P < .01). CONCLUSION: This study analyzed elbow joint moments in different directions during daily tasks. The outcomes question whether postoperative instruction can lead to decreasing elbow loads. Future research might focus on reducing elbow loads in the flexion-extension and varus-valgus directions.


Asunto(s)
Artroplastia de Reemplazo de Codo , Articulación del Codo , Masculino , Humanos , Adulto , Persona de Mediana Edad , Articulación del Codo/cirugía , Codo , Actividades Cotidianas , Movimiento , Fenómenos Biomecánicos
20.
Front Pharmacol ; 14: 1280234, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38089061

RESUMEN

Background: Hyperlipidemia is associated with a higher rate of cardiovascular, cerebrovascular, and peripheral vascular disease. Conventional drugs such as statins are effective in controlling hyperlipidemia; however, they are associated with various side effects, especially myalgia. Nutraceutical lipid-lowering interventions are becoming increasingly popular, particularly among patients who are intolerant or refractory to statins. Substantial preclinical and clinical evidence suggests that extracts of amla, walnut, and olive, and red yeast rice (RYR) powder possess significant antihyperlipidemic effects. Aims: This study aimed to evaluate the efficacy, safety, and patient satisfaction of a combined supplementation of standardized dry extracts of amla fruit (500 mg), walnut leaves (50 mg), olive fruit (25 mg), and RYR powder (33.6 mg) (Cholesfytol NG®) in hypercholesterolemic patients. Methods: This was a real-life setting, retrospective, observational, single-arm, non-randomized study in hypercholesterolemic patients (total cholesterol (TC) ≥ 200 mg/dL or low-density lipoprotein-cholesterol (LDL-C) ≥ 130 mg/dL), enrolled at 57 general practitioner (GP) surgeries in Belgium from March 2020 to January 2022. These patients received a GP-prescribed daily single dosage of two oral tablets of Cholesfytol NG® supplementation for 2 months to overcome their hypercholesterolemia in the absence of a conventional lipid-lowering drug (n = 208) or with a lipid-lowering drug (n = 13). At 2-month follow-up, the lipid profile was re-evaluated, alongside a patient's questionnaire on treatment general satisfaction and willingness to pursue supplementation. Results: After supplementation, TC decreased by 15%, LDL-C by 19%, non-high-density lipoprotein-cholesterol (non-HDL-C) by 20% (all p < 0.0001), triglycerides (TG) by 9% (p = 0.0028) (-18.4%, p = 0.0042, in patients with baseline TG > 180 mg/dL, n = 58), and remnant cholesterol (RC) by 12% (p = 0.0001). These changes were unaffected by statin intolerance status in patients who received Cholesfytol NG® alongside statin. The supplement was well tolerated by all patients, and no serious adverse events or supplement-emergent effects were reported. Most patients were satisfied with the supplementation and wanted to pursue the nutraceutical. Conclusion: According to the results of this study, a combined supplementation of amla, walnut, and olive extracts, and RYR powder exerts a significant antihyperlipidemic effect, leading to a decrease in circulatory LDL-C and RC levels in patients with hypercholesterolemia. The supplementation bears excellent safety and tolerability, and is rated as satisfactory and pursuable, even among patients with statin intolerance. Clinical Trial Registration: clinicaltrials.gov; identifier number: NCT06002893.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...