Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Z Geburtshilfe Neonatol ; 226(4): 245-250, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35545124

RESUMEN

OBJECTIVE: To evaluate the impact of preoperative cervical length on pregnancy outcome in monochorionic diamniotic twin pregnancies complicated by twin-twin transfusion syndrome that underwent laser surgery or cord occlusion. MATERIALS AND METHODS: Retrospective study of 330 patients stratified by preoperative cervical length (≥25 mm, 16-24 mm,≤15 mm). Maternal characteristics, operative data, and pregnancy outcomes were compared between the cervical length groups as well as between the subgroups of patients with a cervical length≤15 mm according to management (expectant vs. cerclage). RESULTS: A preoperative cervical length≥25 mm was observed in 82% (n=271) of cases, 16-24 mm in 9% (n=29), and≤15 mm in 9% (n=30). Patients with a preoperative cervical length≤15 mm showed shorter median procedure-to-delivery interval (5.5 weeks vs. 11.6 (16-24 mm) vs. 13.0 (≥25 mm); p<0.001); lower median gestational age at delivery (29.5 weeks vs. 34.3 (16-24 mm) vs. 33.4 (≥25 mm); p<0.001); higher rate of preterm delivery<32 weeks (78 vs. 20% (16-24 mm) vs. 31% (≥25 mm); p<0.001); and lower neonatal survival rate of at least one twin (70 vs. 88% (16-24 mm) vs. 93% (≥25 mm); p<0.001). Outcome of patients with a preoperative cervical length≤15 mm was similar regardless of management. CONCLUSION: Monochorionic diamniotic twin pregnancies complicated by twin-twin transfusion syndrome with a preoperative cervical length≤15 mm showed a higher rate of preterm delivery<32 weeks and lower neonatal survival. The role of a cervical cerclage remains unclear.


Asunto(s)
Cerclaje Cervical , Transfusión Feto-Fetal , Nacimiento Prematuro , Femenino , Transfusión Feto-Fetal/diagnóstico por imagen , Transfusión Feto-Fetal/cirugía , Edad Gestacional , Humanos , Recién Nacido , Embarazo , Resultado del Embarazo/epidemiología , Embarazo Gemelar , Estudios Retrospectivos
2.
Am J Obstet Gynecol ; 227(3): 502.e1-502.e25, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35351412

RESUMEN

BACKGROUND: The persistent changes in cardiac structure and function in children who survived twin-to-twin transfusion syndrome remain a matter of concern and controversy. Current fetal echocardiographic parameters and their postnatal evolution can help improve our understanding of the subject. OBJECTIVE: To describe the echocardiographic changes of monochorionic fetuses affected by twin-to-twin transfusion syndrome, the recipient and the donor, before and after laser photocoagulation and to determine their evolution in the third trimester and during their first year of life. STUDY DESIGN: An observational study was conducted including 55 uncomplicated monochorionic diamniotic twins and 78 pairs with twin-to-twin transfusion syndrome, 44 stage I-II and 34 stage III-IV, prospectively enrolled from 2015 until 2018. Comprehensive echocardiography was performed at 4 time periods: before laser photocoagulation, at 24 to 72 hours after surgery, at 28 to 30 weeks of gestation, and at 6 to 12 months after birth. Echocardiographic parameters were transformed to z-scores or indexed for heart area, estimated fetal weight, or body mass surface. RESULTS: At diagnosis, recipients in all stages presented larger hearts (cardiothoracic ratio z-score: 2.77 [0.8] vs controls: -0.03 [0.5]; P<.001) and signs of ventricular hypertrophy (left end-diastolic ventricle wall thickness: 2.68 [0.7] vs controls -0.03 [0.7]; P<.001), along with systolic (cardiac index recipients: 317 [114] mL/min/kg vs controls: 400 [120] mL/min/kg, P<.001) and diastolic impairment (isovolumetric relaxation time z-score: 2.76 [0.6] vs controls: 0.05 [0.6]; P<.001). Donors presented smaller ventricular areas and diameters when compared with controls (left end-diastolic ventricle area z-score: -1.48 [1] vs 0.03 [0.9]; P<.001), along with decreased longitudinal motion (tricuspid annular plane systolic excursion z-score: -0.9 [1] vs controls -0.04 [1]; P<.001) and shorter ejection time z-score (-1.5 [0.7] vs controls: 0.0 [0.7]; P<.001). After surgery, an improvement in functional parameters was observed in both fetuses, whereas most morphometric changes prevailed in donors and recipients in the prenatal period. Postnatally, cardiac remodeling persisted in recipients (left relative wall thickness: 0.34 [0.02] vs controls: 0.30 [0.02]; P<.001), whereas donors mainly presented a decreased longitudinal motion in infancy (tricuspid annular plane systolic excursion z-score: -0.72 [0.7] vs controls: 0.23 [0.9]; P<.05). CONCLUSION: Cardiac remodeling is present in both fetuses at the twin-to-twin transfusion syndrome diagnosis, whereas diastolic dysfunction is only significant in the recipient. Fetal therapy improves most echocardiographic parameters, although postnatally, the echocardiographic changes persist in both fetuses.


Asunto(s)
Transfusión Feto-Fetal , Niño , Ecocardiografía , Femenino , Transfusión Feto-Fetal/diagnóstico por imagen , Transfusión Feto-Fetal/cirugía , Corazón , Ventrículos Cardíacos , Humanos , Embarazo , Ultrasonografía Prenatal , Remodelación Ventricular
3.
Am J Obstet Gynecol MFM ; 4(3): 100593, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35144009

RESUMEN

BACKGROUND: Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semirigid bioadhesive patch composed of silicone and hydroxypropyl methylcellulose that achieved ex vivo sealing of membrane defects. OBJECTIVE: To evaluate the feasibility of the insertion of our integrated semirigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in an in vivo ovine model. STUDY DESIGN: An experimental study involving 2 experiments: (1) ex vivo-human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of 2 different bioadhesive patches made of silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures included insertion time, successful insertion, and adhesion at 5 minutes; (2) in vivo-16 patches of silicone-hydroxypropyl methylcellulose were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures included successful insertion, adhesion at 5 minutes, and adhesion at the end of surgery. RESULTS: In the ex vivo insertion study, there was no difference in the insertion time between silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose patches (P=.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for silicone-hydroxypropyl methylcellulose (P=.02). In the in vivo study, insertion of silicone-hydroxypropyl methylcellulose by fetoscopy was feasible and successful in all cases, and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8% and 56.3% of the patches, respectively. CONCLUSION: We describe the feasibility of deploying through a fetoscopic trocar a semirigid silicone-hydroxypropyl methylcellulose patch that seals fetal membranes after an invasive fetal procedure. The results warrant further research for improving long-term adhesion and developing a clinically applicable system.


Asunto(s)
Fetoscopía , Poliuretanos , Animales , Femenino , Fetoscopios , Fetoscopía/métodos , Derivados de la Hipromelosa , Embarazo , Ovinos , Siliconas
4.
Fetal Diagn Ther ; 48(6): 457-463, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34130298

RESUMEN

INTRODUCTION: Preterm prelabor rupture of membranes (PPROM) is a common complication after fetal surgeries. The aim of this study was to assess risk factors for and outcomes after PPROM following cord occlusion (CO) in monochorionic diamniotic (MCDA) pregnancies. METHODS: This was a retrospective cohort study of 188 consecutive MCDA pregnancies treated by bipolar or laser CO, either primarily because of discordant malformation (dMF) or severe selective fetal growth restriction (sFGR), or secondarily when complete bichorionization was not possible in case of twin-to-twin transfusion syndrome (TTTS) or sFGR. Intentional septostomy was performed when needed. The procedure-related PPROM was defined as rupture of membranes <32 weeks' gestation (PROM <32 weeks). Selected pre-, intra-, and early postoperative variables were analyzed by univariate and binomial logistic regression to determine they are correlated to PROM <32 weeks after CO. RESULTS: Between 2006 and 2017, 188 cases underwent CO. Diagnosis was TTTS in 28.2% (n = 53), severe sFGR in 49.5% (n = 93), and dMF in 22.3% (n = 42). PROM <32 weeks occurred in 21.3% (n = 40), resulting in worse perinatal outcomes, as preterm birth <32 weeks occurred in 80.7% (vs. 8.3%, p = 0.000), procedure-to-delivery interval was 47.5 days (vs. 125, p = 0.000), gestational age (GA) at birth 30.0 weeks (vs. 37.7 weeks, p = 0.000), and survival 65.0% (vs. 91.1%, p = 0.000). In univariate analysis, indication, anterior placenta, cervical length, GA at surgery, operation time, amniodistention and drainage fluid volumes, chorioamniotic membrane separation, and septostomy were selected as relevant factors to be included in the regression model. In a multivariate analysis, TTTS was the only factor associated to PROM <32 weeks (OR 3.5 CI 95% 1.5-7.9). CONCLUSIONS: PROM <32 weeks after CO increases the risk of preterm delivery. In this cohort, the membrane rupture was more likely when CO was done in the context of TTTS.


Asunto(s)
Transfusión Feto-Fetal , Nacimiento Prematuro , Femenino , Transfusión Feto-Fetal/epidemiología , Transfusión Feto-Fetal/cirugía , Humanos , Lactante , Recién Nacido , Embarazo , Embarazo Gemelar , Nacimiento Prematuro/epidemiología , Nacimiento Prematuro/etiología , Estudios Retrospectivos , Factores de Riesgo , Gemelos Monocigóticos
5.
Sci Rep ; 11(1): 6109, 2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33731777

RESUMEN

Open fetal surgery for spina bifida (SB) is safe and effective yet invasive. The growing interest in fetoscopic SB repair (fSB-repair) prompts the need for appropriate training. We aimed to develop and validate a high-fidelity training model for fSB-repair. fSB-repair was simulated in the abdominal cavity and on the stomach of adult rabbits. Laparoscopic fetal surgeons served either as novices (n = 2) or experts (n = 3) based on their experience. Technical performance was evaluated using competency Cumulative Sum (CUSUM) analysis and the group splitting method. Main outcome measure for CUSUM competency was a composite binary outcome for surgical success, i.e. watertight repair, operation time ≤ 180 min and Objective-Structured-Assessment-of-Technical-Skills (OSATS) score ≥ 18/25. Construct validity was first confirmed since competency levels of novices and experts during their six first cases using both methods were significantly different. Criterion validity was also established as 33 consecutive procedures were needed for novices to reach competency using learning curve CUSUM, which is a number comparable to that of clinical fSB-repair. Finally, we surveyed expert fetal surgeons worldwide to assess face and content validity. Respondents (26/49; 53%) confirmed it with ≥ 71% of scores for overall realism ≥ 4/7 and usefulness ≥ 3/5. We propose to use our high-fidelity model to determine and shorten the learning curve of laparoscopic fetal surgeons and retain operative skills.


Asunto(s)
Fetoscopía/educación , Modelos Biológicos , Entrenamiento Simulado , Disrafia Espinal/cirugía , Animales , Competencia Clínica , Humanos , Masculino , Conejos
6.
Sci Rep ; 10(1): 18608, 2020 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-33122661

RESUMEN

Preterm prelabor rupture of membranes (PPROM) is the most frequent complication of fetal surgery. Strategies to seal the membrane defect created by fetoscopy aiming to reduce the occurrence of PPROM have been attempted with little success. The objective of this study was to evaluate the ex-vivo mechanical sealing properties and toxicity of four different bioadhesives integrated in semi-rigid patches for fetal membranes. We performed and ex-vivo study using term human fetal membranes to compare the four integrated patches composed of silicone or silicone-polyurethane combined with dopaminated-hyaluronic acid or hydroxypropyl methylcellulose (HPMC). For mechanical sealing properties, membranes were mounted in a multiaxial inflation device with saline, perforated and sealed with the 4 combinations. We measured bursting pressure and maximum pressure free of leakage (n = 8). For toxicity, an organ culture of membranes sealed with the patches was used to measure pyknotic index (PI) and lactate dehydrogenase (LDH) concentration (n = 5). All bioadhesives achieved appropriate bursting pressures, but only HPMC forms achieved high maximum pressures free of leakage. Concerning toxicity, bioadhesives showed low PI and LDH levels, suggesting no cell toxicity. We conclude that a semi-rigid patch coated with HPMC achieved ex-vivo sealing of iatrogenic defects in fetal membranes with no signs of cell toxicity. These results warrant further research addressing long-term adhesiveness and feasibility as a sealing system for fetoscopy.


Asunto(s)
Adhesivos/uso terapéutico , Membranas Extraembrionarias/cirugía , Rotura Prematura de Membranas Fetales/cirugía , Enfermedad Iatrogénica/prevención & control , Membranas Extraembrionarias/metabolismo , Femenino , Rotura Prematura de Membranas Fetales/metabolismo , Fetoscopía/métodos , Edad Gestacional , Humanos , Ácido Hialurónico/administración & dosificación , Derivados de la Hipromelosa/administración & dosificación , L-Lactato Deshidrogenasa/metabolismo , Técnicas de Cultivo de Órganos/métodos , Poliuretanos/administración & dosificación , Embarazo , Siliconas/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...