Acta Biomater ; 9(6): 7054-63, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23485855

RESUMEN

The objective of the present study was to evaluate the biotribological behaviour, in terms of wear and particle release, of bushings and flanges made of carbon fibre reinforced poly-ether-ether-ketone (CFR-PEEK) in articulation with a zirconium nitride (ZrN) multilayer surface coating in a rotating hinge knee system. For the bushings of the rotational and flexion axles and the medial and lateral flanges, a CFR-PEEK with 30% polyacrylonitrile fibre content was used in a new bearing combination with ZrN. In vitro wear simulation was performed for patients with metal ion hypersensitivity, using a new rotating hinge knee design with a ZrN surface articulation in comparison with the clinically established cobalt-chromium version. For the bushings and flanges made of CFR-PEEK subjected to wear simulation, the volumetric wear rates were 2.3±0.48mm(3)million(-1) cycles in articulation to cobalt-chromium as reference and 0.21±0.02mm(3)million(-1) cycles in the coupling with ZrN, a 10.9-fold decrease. The released CFR-PEEK particles were comparable in size and shape for the coupling to cobalt-chromium and ZrN with most of the particles in a size range between 0.1 and 2µm. The study reveals comparable low wear and no macroscopic surface fatigue in a new rotating hinge knee design with highly congruent flanges and axles bushings made of CFR-PEEK articulating to a ZrN multilayer surface coating. Favourable wear behaviour of the newly introduced CFR-PEEK/ZrN coupling in comparison with the clinically established CFR-PEEK/cobalt-chromium articulation was found.


Asunto(s)
Materiales Biocompatibles/química , Carbono/química , Cetonas/química , Articulación de la Rodilla/fisiología , Lubricantes/química , Lubrificación/métodos , Polietilenglicoles/química , Rango del Movimiento Articular/fisiología , Benzofenonas , Materiales Biomiméticos , Fibra de Carbono , Fricción , Ensayo de Materiales , Polímeros , Rotación
2.
Z Rheumatol ; 66(5): 366-75, 2007 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-17717677

RESUMEN

Only a few of the large number of implants developed during the last decades for replacement of the metacarpophalangeal (MCP) joint have proven to be reliable. The rates of loosening and mechanical failure of almost all types of constrained prostheses are so high that their use cannot be recommended at present. For more than 40 years silicone arthroplasty according to Swanson has been regarded as the gold standard in the prosthetic replacement of the MCP joint. In long-term studies this device provided good pain relief and a lasting correction of preoperative ulnar deviation. The degree of patient satisfaction continues to be high after more than 10 years. With the NeuFlex spacer, a modification of the original Swanson implant, a better range of motion and a reduction of wear-related problems is expected. In this study the results of 130 NeuFlex spacers after a mean time of 3.6 years were examined and 82% of the patients were completely pain free. The mobility of the joints improved from 40 degrees preoperatively to 54 degrees after 3.6 years. Radiologically periprosthetic erosions or osteolyses were seen in approximately 15% of implants. A minimal sinking of the stems developed in 24%, a massive one in 6% and 13% of the spacers were broken. Thus the use of the NeuFlex implant resulted in a better range of motion compared to the Swanson spacer, but the problem of radiological appearance remained unchanged. For unlinked prostheses sufficient soft tissue stability is mandatory as well as wear-resistant surface materials. The pyrocarbon prosthesis according to Beckenbaugh is the only implant for which long-term results are available. In a prospective study we evaluated 28 Ascension pyrocarbon prostheses with a mean follow-up of 4 years. Stability was not found to be a problem. Subjective results were satisfactory, the range of motion remained unchanged, however 46% of prosthesis stems exhibited radiolucent seams, 7 prostheses (25%) were rated as loose and 5 of those had to be replaced by a silicone implant. Use of the implant was abandoned, as it was unreliable regarding bony fixation. There are promising concepts in some new prostheses but independent data are still lacking.


Asunto(s)
Artritis Reumatoide/cirugía , Deformidades Adquiridas de la Mano/cirugía , Prótesis Articulares , Articulación Metacarpofalángica/cirugía , Artritis Reumatoide/diagnóstico , Análisis de Falla de Equipo , Estudios de Seguimiento , Deformidades Adquiridas de la Mano/diagnóstico , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/fisiopatología , Inestabilidad de la Articulación/cirugía , Destreza Motora/fisiología , Dimensión del Dolor , Dolor Postoperatorio/fisiopatología , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Radiografía , Rango del Movimiento Articular/fisiología , Reoperación , Siliconas
3.
Orthopade ; 36(8): 714-22, 2007 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-17641872

RESUMEN

Between 1987 and 2005, 165 patients with rheumatoid arthritis of the elbow, four with psoriatic arthritis, and eight with osteoarthrosis of the elbow were treated with total elbow arthroplasty using 126 semiconstrained GSB III elbow replacement prostheses; 46 semiconstrained Coonrad-Morrey prostheses; 24 Souter-Strathclyde unconstrained, unlinked prosthesis; four constrained link hinge prostheses; two custom-made prostheses; and one Pritchard elbow replacement. All implant procedures relieved pain and improved functionality. The complication rate was 34.4%. Revision surgery was needed in 27.2% of elbows because of infection, dislocation, or aseptic loosening. Survival of the semiconstrained implants with ventral or epicondylar flanges for load transfer was better than that of the other implants. Component linkage with the Coonrad-Morrey implant prevents dislocation without increasing the risk of loosening; therefore, semiconstrained implants are our choice for advanced arthritis of the elbow. Total elbow replacement is associated with a high complication rate and therefore may be warranted only for seriously disabled patients.


Asunto(s)
Artritis Reumatoide/cirugía , Articulación del Codo/cirugía , Luxaciones Articulares/etiología , Inestabilidad de la Articulación/etiología , Prótesis Articulares/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Adulto , Artritis Reumatoide/complicaciones , Artroplastia/efectos adversos , Artroplastia/instrumentación , Análisis de Falla de Equipo , Femenino , Humanos , Luxaciones Articulares/diagnóstico , Inestabilidad de la Articulación/diagnóstico , Masculino , Diseño de Prótesis , Falla de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico
4.
Scand J Plast Reconstr Surg Hand Surg ; 33(4): 433-8, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10614754

RESUMEN

In resection arthroplasty of destroyed metacarpophalangeal joints stabilisation with a silicone spacer is regarded as the gold standard. In 28 patients with rheumatoid arthritis (34 hands) 102 arthroplasties of the metacarpophalangeal joint were assessed a median of 10 years postoperatively (range 8.7-12.5). All patients reported pronounced subjective relief of pain, and in three quarters function of the hand had improved. The median active range of movement decreased from 40 degrees (range 10 degrees-90 degrees) preoperatively to 35 degrees (range 5 degrees-85 degrees) postoperatively. Ulnar deviation was corrected from a median of 35 degrees (range 0 degrees-60 degrees) preoperatively to 10 degrees (range 0 degrees-40 degrees) postoperatively. The extension deficit was improved from a median of 35 degrees (range 10 degrees-80 degrees) before surgery to a median of 10 degrees (range 0 degrees-30 degrees) at follow up. Grip strength remained unchanged. Radiological examination showed surrounding osteolysis in 89% of the implants and 28% had broken. The well-known discrepancy between fair clinical and good subjective results with distinct radiological findings such as osteolysis was therefore confirmed. Material fatigue and sharp bony edges that result from osteolysis may be the cause of the relatively common implant fractures and ulnar deviation in this long-term follow-up.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo , Articulación Metacarpofalángica/cirugía , Artritis Reumatoide/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Articulación Metacarpofalángica/diagnóstico por imagen , Persona de Mediana Edad , Osteólisis , Radiografía , Rango del Movimiento Articular , Siliconas , Resultado del Tratamiento
5.
J Hand Surg Br ; 24(5): 561-4, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10597932

RESUMEN

After silicone arthroplasty of the metacarpophalangeal (MP) joint there is increasing osteolysis, subsidence and fracture of the implants in the longer postoperative term. In 44 patients with rheumatoid arthritis (54 hands) 151 arthroplasties of the metacarpophalangeal joint were assessed at a mean of 3.9 years postoperatively. In 57 arthroplasties titanium protectors (grommets) were used. There were no significant differences in the clinical outcomes with respect to swelling, correction of ulnar deviation, range of active movement and grip strength. The additional use of grommets in MP joint arthroplasty slightly reduced reactive osteolysis, protected the spacers from breakage and slightly reduced the amount of pain with only a few additional complications in the midterm follow-up.


Asunto(s)
Artroplastia de Reemplazo/instrumentación , Articulación Metacarpofalángica/cirugía , Osteoartritis/cirugía , Siliconas , Actividades Cotidianas , Adulto , Anciano , Artroplastia de Reemplazo/efectos adversos , Artroplastia de Reemplazo/métodos , Femenino , Estudios de Seguimiento , Fuerza de la Mano , Humanos , Masculino , Articulación Metacarpofalángica/fisiopatología , Persona de Mediana Edad , Osteoartritis/fisiopatología , Diseño de Prótesis , Ajuste de Prótesis , Rango del Movimiento Articular , Resultado del Tratamiento
6.
Z Rheumatol ; 56(5): 287-97, 1997 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-9465382

RESUMEN

Resection arthroplasty of the metacarpophangeal joints stabilized by a Swanson-Silastic-spacer is the golden standard in MP-joint destruction in R.A. 57 (Gr. I), 91 (Gr. II), and 102 (Gr. III) arthroplasties of the metacarpophalangeal joint were assessed in three groups of patients 3.5 years (Gr. I), 4.3 years (Gr. II), and 10.1 years (Gr. III), respectively, postoperatively on the average. In patients of group I titanium protectors, called grommets, were used additionally. Nearly all patients reported a marked relief of pain. Ulnar drift was corrected from an average of 22 degrees (Gr. I), 23 degrees (Gr. II), and 34 degrees (Gr. III) preoperatively. to 8 degrees (Gr. I), 7 degrees (Gr. II), and 12 degrees (Gr. III), respectively, postoperatively. Active range of motion remains unchanged with an average of 33 degrees (Gr. I), 38 degrees (Gr. II), and 42 degrees (Gr. III) ROM preoperatively and 42 degrees (Gr. I), 37 degrees (Gr. II), and 36 degrees (Gr. III) ROM, respectively, postoperatively. The average extension deficit had improved from 45 degrees (Gr. I), 32 degrees (Gr. II), and 33 degrees (Gr. III) at surgery to 18 degrees (Gr. I), 11 degrees (Gr. II), and 11 degrees (Gr. III), respectively, at the time of follow-up. Functional improvement of the hand was found in the medium term in 82% and in the longterm in 75% of the patients. The radiographical findings showed surrounding osteolysis in 45.7% (Gr. I), 63.5% (Gr. II), and 89.4% (Gr. III) of the implants and 0% (Gr. I), 16.5% (Gr. II), and 26.9% (Gr. III) broken spacers. From the medium to the longterm run there is an increase in radiographical deterioration. The additional use of titanium grommets in MP-joint arthroplasty seems to reduce reactive osteolysis and protects Swanson Silastic-spacers from breakage without substantial influence on the clinical outcome.


Asunto(s)
Artritis Reumatoide/cirugía , Prótesis Articulares , Articulación Metacarpofalángica/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Elastómeros de Silicona , Titanio , Artritis Reumatoide/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Fuerza de la Mano/fisiología , Humanos , Masculino , Articulación Metacarpofalángica/diagnóstico por imagen , Persona de Mediana Edad , Falla de Prótesis , Radiografía , Rango del Movimiento Articular/fisiología
7.
Handchir Mikrochir Plast Chir ; 28(5): 254-64, 1996 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-9026492

RESUMEN

Advanced rheumatoid destruction of the metacarpophalangeal joints frequently requires implant arthroplasty. Among many different types of implants, the Swanson-Silastic-spacer is widely used. The long-term results of 102 arthroplasties of the metacarpophalangeal joint were assessed in 28 rheumatoid patients (34 hands) 10.1 years postoperatively on the average. Marked relief of pain was found in all patients. 75% of the patients reported functional improvement of the hand. Active range of motion decreased from 42 degrees preoperatively to 36 degrees postoperatively on the average. Ulnar drift was corrected from an average of 34 degrees preoperatively to 12 degrees postoperatively. The average extension deficit had improved from 33 degrees at surgery to 11 degrees at the time of follow-up. Grip strength remained unchanged. The radiographical findings showed surrounding osteolysis in 89.4% of the implants and 27.5% broken spacers. In comparison to other types of finger implants, Silastic-spacers showed similarly limited all over results, however, there seem to be less problems in salvage procedures.


Asunto(s)
Artritis Reumatoide/complicaciones , Deformidades Adquiridas de la Mano/etiología , Deformidades Adquiridas de la Mano/cirugía , Prótesis Articulares , Articulación Metacarpofalángica/cirugía , Actividades Cotidianas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Articulación Metacarpofalángica/fisiopatología , Persona de Mediana Edad , Dolor , Diseño de Prótesis , Rango del Movimiento Articular , Resultado del Tratamiento
8.
Clin Rheumatol ; 13(1): 90-7, 1994 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8187452

RESUMEN

Rheumatoid arthritis is a complex disease of unknown origin. In consequence of some immunological reactions, proliferative invading synovial tissue leads to destruction of normal joint architecture. The aim of this study was to investigate qualitative changes in extracellular matrix distribution of proliferating rheumatoid synovium and their cellular origin. Synovial tissues from 57 clinically indicated arthrotomies were investigated with immunofluorescence, using specific antibodies against extracellular matrix proteins in tissue slides and cultured cells, which were also studied for collagen biosynthesis. Results indicated that synovial fibroblast-like cells synthesize and secrete basement membrane proteins laminin and collagen type IV as e.g. endothelial cells or organogenic fibroblasts. Laminin and collagen type IV were specifically demonstrated pericellularly in the hyperplastic lining layer of active rheumatoid synovitis. These findings are discussed with respect to the possible implication of altered cell-matrix interactions in rheumatoid synovial proliferation.


Asunto(s)
Artritis Reumatoide/patología , Fibroblastos/metabolismo , Proteínas de la Membrana/análisis , Proteínas de la Membrana/biosíntesis , Membrana Sinovial/química , Artritis Reumatoide/metabolismo , Membrana Basal/química , Radioisótopos de Carbono , Células Cultivadas , Colágeno/química , Matriz Extracelular/química , Fibronectinas/análisis , Técnica del Anticuerpo Fluorescente , Humanos , Osteoartritis/metabolismo , Péptidos/análisis
10.
Z Rheumatol ; 50(2): 103-8, 1991.
Artículo en Alemán | MEDLINE | ID: mdl-1872041

RESUMEN

The concentration of 6-methoxy-2-naphthyl acetic acid (6-MNA) in plasma, synovial fluid, synovial tissue and fibrous capsule tissue was determined in an open study with 20 patients scheduled for knee joint surgery after oral treatment with nabumetone (Arthaxan) under steady state conditions. 6-MNA is the principal metabolite of the prodrug nabumetone arising from an extensive first-pass metabolism in the liver. The patients suffering from rheumatoid arthritis (n = 12) or osteoarthritis stage III or IV (n = 8) received a daily dose of 1 g nabumetone nocte starting 4 days prior to surgery. On day 1 an additional loading dose of 1 g nabumetone was given in the morning. At the time of surgery (day 5) simultaneously blood and synovial fluid was aspirated and after medial opening of the knee joint biopsies of synovial tissue and fibrous capsule tissue were taken. The samples were analysed employing HPLC. After 4 days of treatment mean 6-MNA concentration in plasma was 40.76 micrograms/ml, in synovial fluid 34.79 micrograms/ml, in synovial tissue 19.33 micrograms/g and in fibrous capsule tissue 11.43 micrograms/g. Under steady state conditions mean synovial fluid levels of 6-MNA were higher than after application of a single dose.


Asunto(s)
Antiinflamatorios no Esteroideos , Artritis Reumatoide/tratamiento farmacológico , Butanonas/uso terapéutico , Articulación de la Rodilla , Ácidos Naftalenoacéticos/farmacocinética , Osteoartritis/tratamiento farmacológico , Líquido Sinovial/metabolismo , Adulto , Anciano , Artritis Reumatoide/sangre , Disponibilidad Biológica , Biotransformación , Butanonas/farmacocinética , Esquema de Medicación , Femenino , Humanos , Articulación de la Rodilla/efectos de los fármacos , Articulación de la Rodilla/metabolismo , Masculino , Persona de Mediana Edad , Nabumetona , Osteoartritis/sangre
11.
Beitr Orthop Traumatol ; 37(11-12): 637-41, 1990.
Artículo en Alemán | MEDLINE | ID: mdl-2100505

RESUMEN

We reviewed experiences and results of six shoulder and nine elbow joint synovectomies, performed in a time period between 1989 and 1990 by arthroscopic technique. The operation technique is pretentious an requires some expenditure. The postoperative course distinguishes itself by little pain and early increase of range of motion.


Asunto(s)
Artritis Reumatoide/cirugía , Artroscopía/métodos , Articulación del Codo/cirugía , Articulación del Hombro/cirugía , Sinovectomía , Estudios de Seguimiento , Humanos , Complicaciones Posoperatorias/etiología
12.
Drugs ; 40 Suppl 5: 57-61, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2081495

RESUMEN

The concentration of 6-methoxy-2-naphthylacetic acid (6-MNA) in plasma, synovial fluid, synovial tissue and fibrous capsule tissue was determined in an open study with 20 patients scheduled for knee joint surgery after oral treatment with nabumetone under steady-state conditions. 6-MNA is the principle metabolite of the prodrug nabumetone arising from an extensive first-pass metabolism in the liver. Patients suffering from rheumatoid arthritis (n = 12) or osteoarthritis stage III or IV (n = 8) received a daily dose of nabumetone 1 g in the evening starting 4 days prior to surgery. On day 1 an additional loading dose of nabumetone 1 g was given in the morning. At the time of surgery (day 5), blood, synovial tissue and fibrous capsule tissue were taken simultaneously. The samples were analysed by high performance liquid chromatography. After 4 days of treatment mean 6-MNA concentration in plasma was 40.76 mg/L, in synovial fluid 34.79 mg/L, in synovial tissue 19.33 mg/g and in fibrous capsule tissue 11.43 mg/g. Under steady-state conditions mean synovial fluid levels of 6-MNA were higher than after administration of a single dose and, in common with levels in synovial tissue, persist in a range sufficient for in vitro cyclo-oxygenase inhibition.


Asunto(s)
Antiinflamatorios no Esteroideos/metabolismo , Butanonas/metabolismo , Ácidos Naftalenoacéticos/metabolismo , Administración Oral , Adulto , Anciano , Antiinflamatorios no Esteroideos/análisis , Antiinflamatorios no Esteroideos/sangre , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/metabolismo , Butanonas/análisis , Butanonas/sangre , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Nabumetona , Ácidos Naftalenoacéticos/análisis , Ácidos Naftalenoacéticos/sangre
14.
Z Orthop Ihre Grenzgeb ; 123(3): 290-5, 1985.
Artículo en Alemán | MEDLINE | ID: mdl-4050040

RESUMEN

The SKI-knee joint is used since three years. Our experiences comprise 220 cases up to now. The follow-up time is still short, but the implant, which is partially designed very close to normal anatomy and on the other hand regards fundamental biomechanical aspects is showing a comparably low incidence of complications. The complications specifically due to the endoprosthetic system sums up to 10%. It is obvious that patellar complications are leading. This fact should be seen in close connexion to the anatomical design of the femoral component. With increasing experience these problems are diminished. Causes and potential elimination of patellar complications are discussed. Surgical procedure, especially advantages in comparison with other knee joints are described. The SKI-System in combination with its aligning instruments allow the surgeon anatomical reconstruction, very exact alignment of the implant and precise correction of preexisting deformities. In general the results are encouraging in comparison with formerly used knee joints after the same follow-up period.


Asunto(s)
Prótesis de la Rodilla , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla/rehabilitación , Masculino , Métodos , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Radiografía