Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Indian J Otolaryngol Head Neck Surg ; 73(1): 12-17, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33643879

RESUMEN

This study aimed to assess the balance function in children with sensorineural hearing loss (SNHL) using different tests to assess vestibulospinal pathway and tests to assess vestibular system and to compare the result obtained with those of children with normal hearing sensitivity. Detailed balance assessment was done for 15 children with severe to profound SNHL and 15 children with normal hearing sensitivity in the age range of 6-10 years. The audiological evaluation included pure-tone audiometry, speech audiometry, immittance evaluation, otoacoustic emission, vestibular evoked myogenic potential (cervical VEMP and ocular VEMP), and tests to assess vestibulospinal pathway and cerebellar function, such as Romberg test, Fukuda stepping test, Tandem gait test, and Finger-to-nose test. cVEMP and oVEMP were absent in 8 ears (27%) of a total of 30 ears with SNHL. Statistical analysis shows no significant difference between latency and amplitude of cVEMP peaks and latency of oVEMP peaks across groups. Significant reduction of oVEMP peaks amplitude was seen in children with SNHL compared to children with normal hearing. Fukuda stepping test showed an abnormal response in 2 children with SNHL (13%) and one child could not perform tandem gait test (7%). Children with SNHL showed an evident abnormality on the balance assessment test results. The abnormal function of the vestibular system and the vestibulospinal pathway can compromise the child's motor development and thus needs investigation early in life.

2.
Nanomaterials (Basel) ; 10(6)2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-32492808

RESUMEN

In present work, carbon nanomaterials (CNMs) are investigated as potential carriers of 68Ga, which is widely used in positron emission tomography (PET) in nuclear medicine. Sorption behavior of 68Ga was studied onto CNMs of various structures and chemical compositions: nanodiamonds (ND), reduced graphite oxide (rGiO) and multi-walled carbon nanotubes (MWCNT), as well as their oxidized (ND-COOH) or reduced (rGiO-H, MWCNT-H) forms. The physicochemical properties of the nanoparticles were determined by high resolution transmission electron microscopy, x-ray photoelectron spectroscopy, dynamic light scattering and potentiometric titration. The content of 68Ga in the solutions during the study of sorption was determined by gamma-ray spectrometry. The highest degree of 68Ga sorption was observed on ND and ND-COOH samples, and the optimal sorption conditions were determined: an aqueous solution with a pH of 5-7, m/V ratio of 50 µg/mL and a room temperature (25 °C). The 68Ga@ND and 68Ga@ND-COOH conjugates were found to be stable in a model blood solution-phosphate-buffered saline with a pH of 7.3, containing 40 g/L of bovine serum albumin: 68Ga desorption from these samples in 90 minutes was no more than 20% at 25 °Ð¡ and up to 30% at 37 °Ð¡. Such a quantity of desorbed 68Ga does not harm the body and does not interfere with the PET imaging process. Thus, ND and ND-COOH are promising CNMs for using as carriers of 68Ga for PET diagnostics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...