Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cardiol J ; 30(2): 221-227, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-33438178

RESUMEN

BACKGROUND: Aortic stiffness is a well-known cardio-vascular risk factor. For years, different methods have been studied in the assessment of aortic elastic properties and large arterial stiffness for risk stratification. Herein is an assessment of the role of intravascular ultrasound (IVUS) imaging for the evaluation of aortic elastic properties. METHODS: Intravascular ultrasound imaging of the aorta was performed in 12 patients with transthoracic echocardiography (TTE) and computed tomography (CT) evidence for enlargement of the ascending aorta - diameter ≥ 40.0 mm. Mechanical properties of the aorta were derived from the measured diameters and intra-aortic pressure. Paired samples T-test analyses were performed to determine differences between measurements derived by TTE, CT and IVUS. RESULTS: Mean values of the calculated elastic properties via IVUS of the ascending aorta were as follows: compliance 0.021 ± 0.02; strain 205 ± 4.3; aortic stiffness index 4.3 ± 0.75; elastic modulus 0.31 ± 0.05. On paired T-test analysis maximum ascending aortic diameter measured by CT aortography and IVUS did not differ significantly (t = -0.19, p = 0.985), but a significant difference between IVUS measurements and TTE derived diameters was found (t = 13.118, p = 0.034). On average, IVUS diameters were 2.3 mm larger than the results acquired by TTE (95% confidence interval: 14.21-17.13). CONCLUSIONS: Intravascular ultrasound examination of the ascending aorta provided larger diameters than the ones collected by means of TTE. However, IVUS measurements did not differ significantly from diameters derived by CT aortography.


Asunto(s)
Rigidez Vascular , Humanos , Ultrasonografía , Aorta/diagnóstico por imagen , Ecocardiografía/métodos , Ultrasonografía Intervencional
2.
Future Cardiol ; 16(5): 397-404, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32286883

RESUMEN

The bifurcation optimization stent system (BiOSS) LIM (Balton, Warsaw, Poland) stent is a dedicated coronary bifurcation stent. Its unique construction is developed in accordance with the anatomy of the coronary bifurcations, thus eliminating the carina displacement as a mechanism of side branch ostium compromise. Since its development in 2008, the BiOSS stent underwent several changes with the latest version created of sirolimus eluting cobalt-chromium stent. Results from registries and randomized clinical trials showed that implantation of the BiOSS stent is safe and effective with comparable results for major adverse cardiovascular events (MACE) and target lesion revascularisation rates between the BiOSS and regular drug-eluting stent groups. This stent provides alternative for coronary bifurcation treatment, especially when there is a large difference in diameter between the main vessel and the main branch.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Sirolimus , Stents , Resultado del Tratamiento
3.
JACC Case Rep ; 1(1): 73-74, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34316749

RESUMEN

This report describes the case of a man with Bow Hunter's syndrome that was diagnosed by dynamic cerebral angiography. A decision for endovascular treatment was made. A self-expandable stent, 8 × 300 mm, was implanted in the left vertebral artery with excellent results, with resolution of the patient's symptoms and without any procedure-related complications. (Level of Difficulty: Advanced.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA