Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Obes Surg ; 34(5): 1737-1741, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38528214

RESUMEN

BACKGROUND: Obesity is a risk factor for hyperuricemia and gout, while weight reduction can reduce urate levels. The aim of this study was to examine the effect of bariatric surgery on longitudinal serum urate levels. METHODS: We performed a retrospective observational study of 283 patients who had undergone bariatric surgery [237 (83.7%) gastric bypass, 34 (12.0%) sleeve gastrectomy and 12 (4.2%) gastric banding] and were followed up for 2 years. The results shown represent mean (standard deviation). RESULTS: Bariatric surgery was associated with significant reduction in serum urate from baseline level of 0.343 (0.086) mmol/L to 0.296 (0.076) mmol/L (p < 0.001) at 12 months and 0.286 (0.073) mmol/L (p < 0.001) at 24 months, including in men and women, and in patients with or without diabetes. Patients with elevated urate levels at baseline, who comprised 27.2% of the total cohort, achieved reduction in levels by 4 months. CONCLUSION: Bariatric surgery leads to significant reduction in serum urate levels at 12 and 24 months. This could reduce incidence of gout and need for prophylactic medication(s).


Asunto(s)
Cirugía Bariátrica , Derivación Gástrica , Gota , Obesidad Mórbida , Masculino , Humanos , Femenino , Ácido Úrico , Obesidad Mórbida/cirugía , Obesidad/complicaciones , Obesidad/cirugía , Cirugía Bariátrica/métodos , Derivación Gástrica/métodos , Estudios Retrospectivos , Gastrectomía/métodos , Resultado del Tratamiento
3.
Biosens Bioelectron ; 20(2): 328-37, 2004 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-15308238

RESUMEN

A novel and patented procedure is described for the sonochemical fabrication of a new class of microelectrode array based sensor with electrode element populations of up to 2 x 10(5) cm(-2). For some years it has been accepted that microelectrode arrays offer an attractive route for lowering minimum limits of detection and imparting stir (convectional mass transport) independence to sensor responses; despite this no commercial biosensors, to date, have employed microelectrode arrays, largely due to the cost of conventional fabrication routes that have not proved commercially viable for disposable devices. Biosensors formed by our sonochemical approach offer unrivalled sensitivity and impart stir independence to sensor responses. This format lends itself for mass fabrication due to the simplicity and inexpensiveness of the approach; in the first instance impedimetric and amperometric sensors are reported for glucose as model systems. Sensors already developed for ethanol, oxalate and a number of pesticide determinations will be reported in subsequent publications.


Asunto(s)
Técnicas Biosensibles/instrumentación , Electroquímica/instrumentación , Glucosa Oxidasa/química , Glucosa/análisis , Glucosa/química , Microelectrodos , Sonicación , Técnicas Biosensibles/métodos , Materiales Biocompatibles Revestidos/química , Electroquímica/métodos , Enzimas Inmovilizadas/análisis , Enzimas Inmovilizadas/química , Diseño de Equipo , Análisis de Falla de Equipo , Glucosa Oxidasa/análisis , Materiales Manufacturados , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA