Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Environ Sci Technol ; 57(1): 96-108, 2023 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-36548159

RESUMEN

We performed more than a year of mobile, 1 Hz measurements of lung-deposited surface area (LDSA, the surface area of 20-400 nm diameter particles, deposited in alveolar regions of lungs) and optically assessed fine particulate matter (PM2.5), black carbon (BC), and nitrogen dioxide (NO2) in central London. We spatially correlated these pollutants to two urban emission sources: major roadways and restaurants. We show that optical PM2.5 is an ineffective indicator of tailpipe emissions on major roadways, where we do observe statistically higher LDSA, BC, and NO2. Additionally, we find pollutant hot spots in commercial neighborhoods with more restaurants. A low LDSA (15 µm2 cm-3) occurs in areas with fewer major roadways and restaurants, while the highest LDSA (25 µm2 cm-3) occurs in areas with more of both sources. By isolating areas that are higher in one source than the other, we demonstrate the comparable impacts of traffic and restaurants on LDSA. Ratios of hyperlocal enhancements (ΔLDSA:ΔBC and ΔLDSA:ΔNO2) are higher in commercial neighborhoods than on major roadways, further demonstrating the influence of restaurant emissions on LDSA. We demonstrate the added value of using particle surface in identifying hyperlocal patterns of health-relevant PM components, especially in areas with strong vehicular emissions where the high LDSA does not translate to high PM2.5.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Contaminantes Ambientales , Material Particulado/análisis , Contaminantes Atmosféricos/análisis , Dióxido de Nitrógeno/análisis , Londres , Emisiones de Vehículos/análisis , Pulmón , Monitoreo del Ambiente , Contaminación del Aire/análisis
2.
Cardiovasc Revasc Med ; 41: 35-46, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35140053

RESUMEN

BACKGROUND/PURPOSE: Device-related thrombosis (DRT) is one of the greatest challenges of transcatheter left atrial appendage device occlusion. Due to the invasive nature of transesophageal echocardiography (TEE), cardiac computed tomography angiography (CCTA) is being increasingly utilized in several centers for assessing adequate left atrial appendage closure and monitoring for DRT. There is a paucity of data regarding the standardized definition of DRT on CCTA for the WATCHMAN FLX™ device. METHODS/MATERIALS: A retrospective review was conducted on 43 patients receiving WATCHMAN FLX™ device implantation with CCTA performed at the first follow-up at our institution. A comparative review of DRT predictors was performed on 10 patients who had both CCTA and TEE at the time of follow-up. RESULTS: Hypoattenuated thickening (HAT) was a common finding on CCTA and was noted to be present in 95.35% of the patients. The combination of a large device size, peridevice gap >4 mm, and HAT located on the device gutter and 1 shoulder were characteristics present on CCTA observed in 2 patients with confirmed DRT on TEE. CONCLUSION: CCTA is a noninvasive imaging modality for DRT monitoring, with guidelines still in development. We report potential predictors of DRT on CCTA. Additional studies are needed to further determine standardized parameters for DRT detection on CCTA and the significance of HAT with multimodality correlation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Trombosis , Apéndice Atrial/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Angiografía por Tomografía Computarizada/métodos , Ecocardiografía Transesofágica/métodos , Humanos , Estudios Observacionales como Asunto , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Resultado del Tratamiento
6.
Sci Rep ; 8(1): 5816, 2018 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-29643411

RESUMEN

The application of new sorbent-film coated passive samplers for capture of bulk commercial and military explosives vapours in operationally relevant spaces such as luggage, rooms, vehicles and shipping containers is presented. Samplers were easily integrated with in-service detection technologies with little/no sample preparation required. Ethylene glycol dinitrate (EGDN) was detected within 4 h in a container holding a suitcase packed with 0.2 kg Perunit 28E. Within a 22,000 dm3 room, 1 kg of concealed Seguridad was detected within 24 h and in an adjoining room within 7 days. Exposed samplers also successfully captured components of 1 kg TNT after 72 h and 1 kg concealed Perunit 28E after 6 h in both a furnished room and a large, partially filled shipping container. For the latter, samplers captured detectable residues outside the container after 24 h and were stable during wet weather for 72 h. A one-week trial at three operationally relevant venues including a university, a theatre and a government building revealed a nuisance positive rate of <1.4% (n = 72). Finally, two alternative applications are presented for extraction of liquid samples and use a particulate contact swab showing flexibility for a range of different search activities.

7.
Sci Rep ; 8(1): 5815, 2018 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-29643465

RESUMEN

A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3-5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...