1.
J Arthroplasty ; 39(4): 985-990, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37871861

RESUMEN

BACKGROUND: Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of this study was to assess the survival rate and the reasons for revision of the DeltaMotion cup. METHODS: Data from the AOANJRR were analyzed for all patients who had undergone a primary conventional THA performed between January 1, 2001 and December 31, 2021. Only prostheses with ceramic/ceramic, ceramic/XLPE, metal/XLPE, or CM/XLPE bearing surfaces were included. The primary outcome measure was the cumulative percent revision for all causes. Secondary outcome measures were revision for dislocation/instability, ceramic breakage, or noise. A subanalysis for cup size was also performed. RESULTS: There were 486,946 primary conventional THA procedures undertaken for any reason. Of these, 4,033 used the DeltaMotion cup and 482,913 were modular designs. The DeltaMotion cup had the lowest CPR for all diagnoses compared to the modular bearings at all time points, had a significantly lower revision rate for prosthesis dislocation and no revisions for squeaking compared to other modular bearings. There were 175 ceramic breakages recorded in the modular bearing group and 1 ceramic breakage in the DeltaMotion group. CONCLUSIONS: The DeltaMotion cup had a low rate of all-cause revision, and for dislocation, ceramic breakage, and noise. Although this cup is no longer manufactured, ongoing follow-up of newer monoblock ceramic cups will determine their suitability for younger and more active patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Articulación de la Cadera/cirugía , Falla de Prótesis , Factores de Riesgo , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/métodos , Luxaciones Articulares/cirugía , Cerámica , Reoperación
2.
J Arthroplasty ; 29(5): 1043-51, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24360790

RESUMEN

Bone ingrowth into uncemented acetabular components requires intimate cup-bone contact and rigid fixation, which can be difficult to achieve in revision hip arthroplasty. This study compares polyaxial compression locking screws with non-locked and cancellous screw constructs for acetabular cup fixation. An acetabular cup modified with screw holes to provide both compression and angular stability was implanted into a bone substitute. Coronal lever out, axial torsion and push-out tests were performed with an Instron testing machine, measuring load versus displacement. Polyaxial locking compression screws significantly improved construct stiffness compared with non-locked or cancellous screws. This increased construct stiffness will likely reduce interfacial micromotion. Further research is required to determine whether this will improve bone ingrowth in vivo and reduce cup failure.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Tornillos Óseos , Prótesis de Cadera , Diseño de Prótesis , Acetábulo/fisiopatología , Fenómenos Biomecánicos , Sustitutos de Huesos , Oseointegración