Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
J Clin Med ; 12(22)2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-38002609

RESUMEN

Quadrilateral plate fractures represent a heterogeneous group of acetabular fractures. Accurate reduction is required to prevent post-traumatic arthritis. The purpose of this study is to determine the reduction effect of the direct fixation of quadrilateral plates in acetabular fractures, and to evaluate the strength of direct fixation compared to indirect fixation. Between 2005 and 2021, 49 patients underwent surgery for open reduction and internal fixation in acetabular fractures with severely displaced quadrilateral plates. Twenty-nine patients comprised the indirect fixation group, and twenty patients comprised the direct fixation group. In a comparison of primary outcome between two groups, 10 out of 29 indirect-group patients and 1 out of 20 direct-group patients developed post-traumatic osteoarthritis, wherein the difference between the two groups is statistically significant. In the assessment of postoperative Matta's radiological reduction status, 19 out of 20 patients in the direct group had achieved anatomical and congruent reduction. The treatment using a direct reduction and internal fixation improved the reduction quality of articular displacement and offered a better survivorship of the affected hip joint.

2.
J Clin Med ; 12(19)2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37834870

RESUMEN

Several methods have been introduced to measure the host bone coverage of the acetabular component after total hip arthroplasty (THA). The aims of this study were (1) to validate two-dimensional- and three-dimensional-based host bone coverage measurements by comparing intra-operative measurements, and (2) to determine the minimum host bone coverage for achieving stable cup fixation after THA in hip dysplasia. The clinical outcomes of each patient were evaluated during their final follow-up period using the Harris Hip score (HHS). The coverage of the host bone was analyzed by comparing 2D-based, 3D-based, and intraoperative assessments. The mean HHS was increased significantly from 60.84 ± 14.21 pre-operatively to 93.13 ± 4.59 (p < 0.0001). The host bone coverage ratio measured intraoperatively was 83.67 ± 3.40%, while the ratio measured by 3D CT reconstruction was 82.72 ± 3.59%. There was a strong positive correlation between the intra-operative host bone coverage and the 3D-based one (r = 0.826, p < 0.0001). It is recommended that 3D-based measurements are used to evaluate the host bone coverage after THA in patients with hip dysplasia. In addition, achieving a minimum host bone coverage of 75% is recommended for the attainment of stable cup fixation.

3.
Hip Pelvis ; 34(4): 262-268, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601615

RESUMEN

A fracture of the affected extremity in patients with Klippel-Trenaunay-Weber syndrome can be fatal due to massive bleeding and show poor results. A 42-year-old male presented with an old fracture of the right femoral shaft with metal failure. We planned an operation to remove the previously fixed plate and to perform re-fixation using an intra-medullary nail. Preoperative angiography was performed and the arteriovenous malformations were embolized in order to reduce the risk of bleeding. After angiography, the previously fixed plate was removed. After the operation, a second angiography was performed immediately and the venous malformation was embolized. One week after the first operation, a second operation was performed in order to reduce the fracture and to perform re-fixation using an intramedullary nail. The patient is being followed without major complication over a period of seven years after surgery. We recommend careful planning of preoperative and postoperative angiography and embolization in order to reduce the risk of bleeding in patients with Klippel-Trenaunay-Weber syndrome.

4.
Orthop Traumatol Surg Res ; 108(6): 103041, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34389497

RESUMEN

For periprosthetic joint infection (PJI) treatment, revision total hip arthroplasty using an antibiotic loaded cement spacer is one of the important surgical methods. However, revision total hip arthroplasty using antibiotic-loaded cement spacers poses a risk of spacer dislodgement in patients with acetabular deficiency. We hypothesized that screw augmentation would be more stable and result in lower rates of cement spacer dislodgement in acetabular deficient patients. Thus, we suggest a method of screw augmentation with cement spacers to treat periprosthetic infection in patients with a deficient acetabulum. And we aim to report better clinical outcomes after revision total hip arthroplasty for infection control using screw augmented cement spacer insertion technique. Level of evidence: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Acetábulo/cirugía , Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos/uso terapéutico , Tornillos Óseos , Humanos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/métodos
5.
Bone Joint J ; 103-B(2): 353-359, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33517741

RESUMEN

AIMS: Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). METHODS: Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. RESULTS: The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. CONCLUSION: We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353-359.


Asunto(s)
Corticoesteroides/administración & dosificación , Antiinflamatorios/administración & dosificación , Bursitis/tratamiento farmacológico , Ultrasonografía Intervencional , Corticoesteroides/uso terapéutico , Adulto , Anciano , Antiinflamatorios/uso terapéutico , Bursitis/diagnóstico por imagen , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intraarticulares/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
6.
J Bone Joint Surg Am ; 103(2): 123-130, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33476100

RESUMEN

BACKGROUND: Atypical femoral fracture (AFF) is associated with high prevalence rates of prodromal symptoms, bilateral involvement, complications, and the need for prophylactic fixation due to a risk of an impending fracture. Although most complete AFF cases have an asymptomatic contralateral femur at the initial presentation, there is lack of clarity on its progression. We evaluated the radiographic progression of asymptomatic contralateral femora in patients with a complete AFF and investigated the characteristics of these patients. METHODS: The medical records of 80 consecutive patients who had been treated for a complete AFF were retrospectively evaluated. We excluded 14 patients who had been lost to follow-up, 10 whose contralateral femur initially had been symptomatic and had been treated simultaneously, and 3 whose contralateral femur had previously been treated surgically. The remaining 53 patients were all women with an average age of 71.8 years. The average duration of bisphosphonate (BP) use was 63.6 months, and the mean follow-up duration was 48.9 months. All of the contralateral femora were asymptomatic and were divided into 2 grades according to the initial radiographic findings. We evaluated the prevalence of radiographic progression according to the grades and compared patient characteristics between the progression and non-progression groups. RESULTS: Radiographic progression was noted in 18 patients (34%) during the follow-up: 3 (12%) of 25 in grade 1 and 15 (53.6%) of 28 in grade 2 (p < 0.001). The mean time to progression for these 18 patients was 25.6 months, which also differed significantly depending on the grade (p = 0.02). Eleven and 9 (61.1% and 25.7%) of the patients received BP postoperatively in the progression and non-progression groups, respectively (p = 0.01). CONCLUSIONS: The prevalence of radiographic progression was relatively high, even though the contralateral femur was initially asymptomatic, and differed significantly according to the initial radiographic grade. The frequency of postoperative BP use was significantly higher in the progression group. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas del Fémur/diagnóstico por imagen , Fémur/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Conservadores de la Densidad Ósea/efectos adversos , Difosfonatos/efectos adversos , Progresión de la Enfermedad , Femenino , Fracturas del Fémur/clasificación , Fracturas del Fémur/diagnóstico , Fracturas del Fémur/cirugía , Fémur/lesiones , Fémur/cirugía , Fijación Intramedular de Fracturas , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
7.
J Clin Med ; 9(11)2020 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-33266369

RESUMEN

This study investigated the incidence of failure after locking compression plate (LCP) osteosynthesis around a well-fixed stem of periprosthetic femoral fractures (PFFs). We retrospectively evaluated outcomes of 63 Vancouver type B1 and C PFFs treated with LCP between May 2001 and February 2018. The mean follow-up duration was 47 months. Only patients with fracture fixation with a locking plate without supplemental allograft struts were included. We identified six periprosthetic fractures of proximal Vancouver B1 fractures with spiral pattern (Group A). Vancouver B1 fractures around the stem tip were grouped into seven transverse fracture patterns (Group B) and 38 other fracture patterns such as comminuted, oblique, or spiral (Group C). Vancouver C fractures comprised 12 periprosthetic fractures with spiral, comminuted, or oblique patterns (Group D). Fracture healing without complications was achieved in all six cases in Group A, 4/7 (57%) in Group B, 35/38 (92%) in Group C, and 11/12 (92%) in Group D, respectively. The failure rates of transverse Vancouver type B1 PFFs around the stem tip were significantly different from those of Vancouver type B1/C PFFs with other patterns. For fracture with transverse pattern around the stem tip, additional fixation is necessary because LCP osteosynthesis has high failure rates.

8.
Indian J Orthop ; 54(Suppl 2): 239-245, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33194097

RESUMEN

BACKGROUND: Outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic arthritis due to a higher rate of cup loosening and osteolysis. We, therefore, investigated whether highly cross-linked polyethylene liners positively impact outcomes of THA in patients with posttraumatic osteoarthritis after acetabular fracture. METHODS: We retrospectively evaluated 39 patients with previous acetabular fracture who underwent THA using highly cross-linked polyethylene liner after a mean 8.5 year follow-up. All procedures were performed at a single institution by a single surgeon using the same type of THA implants. Wear measurements were performed using a computer-assisted PolyWare software. Osteolysis was evaluated with use of radiography and computed tomography. RESULTS: The mean preoperative Harris hip score was 44.4 points, which improved to 93.1 points at final follow-up. Neither femoral nor acetabular components displayed mechanical loosening and no components had been revised. Radiographs and CT scans did not demonstrate osteolysis. The mean linear wear was 0.043 mm/y (range 0-0.098 mm/y). With the data available, univariate regression analysis suggests that age, gender, weight, initial fracture type, the duration of follow-up, activity level, liner thickness, acetabular cup inclination, and the necessity of bone graft had no influence on liner penetration. CONCLUSION: While the long-term effects of the polyethylene particles from highly cross-linked polyethylene remain unknown, implant survivorship and wear data in this study are promising for this high-risk population. Our encouraging results support the continued use of this type of polyethylene in patients after acetabular fractures. LEVEL OF EVIDENCE: Level IV Therapeutic study.

9.
Diagnostics (Basel) ; 10(11)2020 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-33143138

RESUMEN

The purpose of our study was the clinical characteristics, radiographic appearance, and outcomes after treatment in patients with rapid destructive arthrosis (RDA) due to subchondral insufficiency fracture (SIF) of the shoulder. Twenty-two cases of RDA of the shoulder were retrospectively reviewed. Clinical outcomes for 15 cases who underwent shoulder arthroplasty were evaluated at an average of 41.4 months. The mean age of patients was 73.7 years (range 50-83 years), and there were 20 women and 2 men. The mean time from onset of symptoms to head collapse was 6.8 months (range 1-12 months). The mean t-score of bone mineral density was -3.1. Nine patients had pseudoparalysis. Based on radiographic appearance, a diversity of types of head destruction with subchondral fracture, bone marrow edema, joint effusion, and synovitis were observed in all cases. In conclusion, RDA due to SIF of the shoulder, presenting with severe short-term pain and functional disability, commonly occurred in elderly women with bone fragility. MRI revealed bone marrow edema, extensive joint effusion, and synovitis as well as a diversity of types of head destruction with subchondral fracture within several months from onset of symptoms.

10.
Clin Orthop Surg ; 12(3): 286-290, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32903950

RESUMEN

The novel coronavirus disease 2019 (COVID-19), which began in Wuhan, China, has rapidly flared up all over the world, evolving into a pandemic. During these critical times, we should give emphasis on infection prevention for the health care staff as well as appropriate patient management in order to maintain the health care system. We report our experience in protecting a surgical team from COVID-19 infection during a bipolar hemiarthroplasty in an infected patient. This case highlights the importance of appropriate protection of the health care staff and education in minimizing the risk of transmission of the infection and maintaining the health care system.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/prevención & control , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia , Control de Infecciones/organización & administración , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Neumonía Viral/prevención & control , Anciano de 80 o más Años , COVID-19 , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/transmisión , Fracturas del Cuello Femoral/microbiología , Humanos , Masculino , Equipo de Protección Personal , Neumonía Viral/diagnóstico , Neumonía Viral/transmisión , República de Corea , SARS-CoV-2
11.
Clin Orthop Surg ; 12(2): 217-223, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32489544

RESUMEN

BACKGROUD: The purpose of this study was to compare early clinical outcomes of manipulation under anesthesia (MUA) and arthroscopic capsular release (ACR) in patients with refractory adhesive capsulitis (AC). METHODS: Thirty AC patients who underwent MUA (MUA group) were included. As a control group, thirty AC patients who underwent ACR (ACR group) were matched for age and sex with the MUA group. Visual analog scale (VAS) pain score, American shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were evaluated preoperatively and at 3, 6, and 12 months after procedure. RESULTS: Both groups had significant improvements in the VAS pain score, ASES score, and ROM at 12 months after procedure. VAS pain score and ASES score were significantly better in the MUA group than in the ACR group at 3 months after procedure. Mean forward flexion was significantly greater in the MUA group than in the ACR group at 3 months after procedure. Mean external rotation and internal rotation were significantly greater in the MUA group than in the ACR group at 3, 6, and 12 months after procedure. Two patients required additional steroid injections at 3 and 6 months after MUA because of recurrent stiffness with pain. CONCLUSIONS: Compared with ACR, MUA provided equivalent clinical outcomes in the early period after procedure. Our study suggests that MUA is a useful option to be considered as treatment for refractory AC before choosing ACR.


Asunto(s)
Artroscopía/métodos , Bursitis/terapia , Liberación de la Cápsula Articular/métodos , Manipulación Ortopédica/métodos , Anestesia , Evaluación de la Discapacidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Rango del Movimiento Articular , Estudios Retrospectivos
12.
Orthopedics ; 43(4): e251-e257, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32271933

RESUMEN

A considerable number of patients who underwent a 2-stage exchange protocol for periprosthetic hip joint infection could not complete the second-stage reimplantation. The aim of this study was to evaluate the results of unintended retention of temporary articulating spacers for the treatment of periprosthetic hip joint infection. Ninety-four patients with infection after total hip arthroplasty were treated by using a 2-stage exchange protocol with temporary articulating spacers. Of the 94 patients, 35 did not complete the 2-stage exchange protocol and retained spacers for more than 12 months. The authors retrospectively investigated the clinical and radiographic results after a mean follow-up of 36.1 months. Thirty-one patients had well-healed wounds without recurrent infection and did not receive further surgery for any reason (success group). Spacers were revised in 2 patients, and the other 2 patients underwent incision and debridement because of recurrent infection (failure group). There were no statistical differences between the 2 groups in terms of demographics or presence of resistant organisms. After 3 years of follow-up, temporary articulating spacers functioned well in 89% of the patients who retained them. These results support that retention of temporary articulating spacers could be considered an alternative treatment option for select patients. [Orthopedics. 2020;43(4):e251-e257.].


Asunto(s)
Artritis Infecciosa/cirugía , Cuerpos Extraños/cirugía , Articulación de la Cadera/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos/efectos adversos , Femenino , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Reimplantación/efectos adversos , Estudios Retrospectivos
13.
Injury ; 51(2): 367-371, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31822345

RESUMEN

INTRODUCTION: The purpose of this study is to evaluate the clinical and radiographic result in patients who got salvage treatment for the failed fixation of intertrochanteric fracture and to evaluate the factors that may affect healing of these treatment. PATIENTS AND METHODS: Between 1997 and 2016, 39 patients who could be followed up for more than 1 year after treatment were enrolled. For determining of factor that may affect healing of treatment, the primary outcome was based on union. There were success group which achieved a restored union and failure group which had an additional revisional surgery because of another complication for analysis. And neck-shaft angle (NSA) was measured with a goniometer. RESULTS: Fracture healing as a primary outcome (after revision surgery) was achieved 31 out of 39 patients (80%). There were no statistically significant differences between two groups in terms of age, sex, BMI and laterality. In the clinical outcomes, four categories of outcomes were compared between the success and failure groups and significant improvements were observed. In measurements at final follow-up, it the angle was 133.4° in the success group and 123.4° in the failure group. CONCLUSION: The clinical and radiographic results of the salvage treatment for the failed fixation of intertrochanteric fracture were satisfactory in our study. Restoration of femoral neck-shaft angle of failed intertrochanteric fracture is key factors for obtaining successful results.


Asunto(s)
Fémur/patología , Fijación Interna de Fracturas/métodos , Fracturas de Cadera/cirugía , Terapia Recuperativa/métodos , Adulto , Anciano , Anciano de 80 o más Años , Clavos Ortopédicos , Tornillos Óseos , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura , Fracturas de Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Estudios Retrospectivos , Terapia Recuperativa/efectos adversos , Insuficiencia del Tratamiento , Adulto Joven
14.
J Arthroplasty ; 35(3): 805-810, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31690522

RESUMEN

BACKGROUND: Polyethylene wear and subsequent periprosthetic osteolysis remain a major concern of total hip arthroplasty (THA) failure in young, active patients with osteonecrosis of the femoral head (ONFH). The literature is lacking regarding the long-term performance of highly cross-linked polyethylene (HXLPE) in these patients. The purpose of this study is to evaluate long-term results for cementless THA using metal-on-HXLPE bearing couplings in patients younger than 50 years with ONFH. METHODS: We retrospectively evaluated the clinical and radiographic results of a consecutive series of 85 THAs (in 67 patients) performed with HXLPE liners (Durasul) in patients younger than 50 years who had ONFH. All procedures were performed at a single institution by a single surgeon using the same type of implants. The minimum duration of follow-up was 10 years (mean, 13.5 years; range, 10-17.3 years). Wear was measured using computer software. Osteolysis was evaluated with the use of radiography and computed tomography. RESULTS: The mean Harris hip score was 49.3 points (range, 26-68 points) before surgery, which improved to 93.6 points (range, 87-98 points) after surgery. Neither femoral nor acetabular components displayed mechanical loosening, and no components had been revised by the final follow-up evaluation. Radiographs and computed tomography scans did not demonstrate osteolysis. The mean liner wear was 0.037 mm/y (range, 0-0.099 mm/y). With the data available, univariate regression analysis did not demonstrate that age, sex, weight, activity level, underlying cause of osteonecrosis, liner thickness, or cup inclination had any influence on liner penetration. CONCLUSION: Although the long-term effects of HXLPE particles remain unknown, the implant survivorship rate and wear rate in our study are promising and support the continued use of metal-on-HXLPE bearing couplings in these high-risk patients because they do not produce any of the issues associated with hard-on-hard couplings. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteólisis , Osteonecrosis , Cabeza Femoral/cirugía , Estudios de Seguimiento , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Tiempo
15.
Injury ; 50(7): 1339-1346, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31151758

RESUMEN

INTRODUCTION: Despite the generally successful outcome of intertrochanteric fracture fixation, the treatment is challenging when fixation failure occurs. Some studies have reported a systemic treatment strategy for salvaging failed intertrochanteric fracture fixation. This prospective study with a retrospective review of data aimed to evaluate and validate the efficacy of an evidence-based protocol developed for the treatment of failed intertrochanteric fractures. PATIENTS AND METHODS: Between 1997 and 2016, 83 patients who could be followed up for more than 1 year after treatment were enrolled at an academic medical centre. An evidence-based protocol was established in July 2008 and was implemented prospectively. The treatment protocol was determined keeping in mind the condition of the femoral head, the deformation of the fracture site and the bone defect. Clinical results were evaluated, and fracture union and femoral neck-shaft angle were evaluated radiographically for patients in valgus osteotomy and re-fixation subgroups. RESULTS: The Pain score, leg length discrepancy, Koval score for ambulatory levels and modified Harris Hip Score showed statistically significant improvement after the implementation of the new protocol. The radiographic success rate was 73% (27 of 37 patients) in the pre-protocol group and 91% (42 of 46 patients) in the post-protocol group, which shows statistically significantly improvement. CONCLUSION: The new treatment strategy for failed intertrochanteric fracture fixation based on the condition of the femoral head, deformation of the fracture site and bone defect is successful based on clinical and radiographic results. Restoration of NSA of failed intertrochanteric fractures is a key factor for obtaining successful results.


Asunto(s)
Desviación Ósea/cirugía , Cabeza Femoral/patología , Fijación Interna de Fracturas/métodos , Fracturas no Consolidadas/cirugía , Adhesión a Directriz , Fracturas de Cadera/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Desviación Ósea/diagnóstico por imagen , Tornillos Óseos , Medicina Basada en la Evidencia , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura , Fracturas no Consolidadas/diagnóstico por imagen , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Osteotomía , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
16.
Arthroplasty ; 1(1): 16, 2019 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-35240767

RESUMEN

PURPOSE: Highly cross-linked polyethylene has been introduced to decrease osteolysis secondary to polyethylene wear debris generation. However, few long-term data on revision total hip arthroplasty (THA) using highly cross-linked polyethylene liners are available. The objective of this study was to determine long-term outcomes of a highly cross-linked polyethylene liner in revision THA. MATERIALS & METHODS: We evaluated 63 revision THAs performed in 63 patients using a highly cross-linked polyethylene liner between April 2000 and February 2005. Of these, nine died and four were lost to follow-up. Thus, the final study cohort consisted of 50 patients (50 hips), including 26 males and 24 females with a mean age of 53 years (range, 27-75 years). Mean follow-up was 11 years (range, 10-14 years). RESULTS: The mean Harris hip score improved from 44 points preoperatively to 85 points at the final follow-up. No radiographic evidence of osteolysis was found in any hip. The mean rate of polyethylene liner wear was 0.029 mm/year (range, 0.003 to 0.098 mm/year). A total of 5 hips (10%) required re-revision arthroplasty, including one cup loosening, one recurrent dislocation, and three deep infections. Kaplan-Meier survivorship with an end point of re-revision for any reason was 91.1% and for aseptic cup loosening was 97.9% at 11 years. CONCLUSION: At a minimum of 10 years, the highly cross-linked polyethylene liners showed excellent clinical performance and implant survivorship, and were not associated with osteolysis in our patients with revision THAs.

17.
Hip Pelvis ; 30(4): 202-209, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30534538

RESUMEN

Atypical femoral fractures differ from ordinary femoral diaphyseal or subtrochanteric fractures in several aspects. Although several authors have reported the results of surgical treatment for atypical femoral fractures, the rate of complications (e.g., delayed union, nonunion, fixation failure, and reoperation) is still high. Therefore, we reviewed principles of surgical treatment and describe useful methods for overcoming femoral bowing in these high-risk patients.

18.
Hip Pelvis ; 30(3): 156-161, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30202749

RESUMEN

PURPOSE: Although advances in technology have reduced the risk of ceramic implant fractures in total hip arthroplasty, these injuries do occur and their treatment remains challenging. There is a lack of studies reporting on the effectiveness of ceramic components in revision hip arthroplasty after ceramic bearing fracture. The aim of this study is to evaluate clinical and radiologic outcomes of revision surgery with ceramic-on-ceramic components after ceramic bearing fractures in young (i.e., under 60 years old) and active patients. MATERIALS AND METHODS: Eight patients who, from May 2004 to November 2011, underwent ceramic-on-ceramic revision surgery following a ceramic component fracture and had more than 6 years follow up were enrolled in this study. All eight patients were male with mean ages at first and revision surgeries of 39 years (range, 31-50 years) and 43.8 years (range, 33-60 years), respectively. There were 6 and 2 cases of ceramic liner and ceramic head fractures, respectively. The average time from the first operation to revision surgery was 54.3 months (range, 9-120 months), and the average follow up period was 9.7 years (range, 6-13.3 years). RESULTS: At the last follow up, all patients showed improvement in Harris hip score and pain relief and there were no cases of loosening or osteolysis. CONCLUSION: Revision total hip arthroplasty using ceramic-on-ceramic components after ceramic component fracture is a feasible and appropriate surgical option in young and active patients.

19.
Clin Orthop Surg ; 10(3): 299-306, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30174805

RESUMEN

BACKGROUND: Although satisfactory mid- to long-term results of rotational acetabular osteotomy for early osteoarthritis secondary to acetabular dysplasia have been reported, there is still controversy about the long-term effects of this surgery in more advanced osteoarthritis. The purpose of this study was to investigate the radiographic progression of osteoarthritic changes after rotational acetabular osteotomy in acetabular dysplasia according to the preoperative Tönnis grade and evaluate its effects after minimum 10-year follow-up. METHODS: We performed 71 consecutive rotational acetabular osteotomies in 64 patients with symptomatic acetabular dysplasia between November 1984 and April 2005. Of these, 46 hips (four hips with Tönnis grade 0, 30 with grade 1, and 12 with grade 2) whose clinical and radiographic findings were available after minimum 10-year follow-up were evaluated in this study. The mean age at the time of surgery was 39.0 years (range, 18 to 62 years) and the average follow-up duration was 17.3 years (range, 10.0 to 27.7 years). Clinical and radiographic evaluations were performed according to the preoperative Tönnis grade. RESULTS: The average Harris hip score improved from 71.8 (range, 58 to 89) to 85.1 (range, 62 to 98). The radiographic parameters also improved in all Tönnis grades after the index surgery. Although the improvement of radiographic parameters was not different between preoperative Tönnis grades, the incidence of osteoarthritic progression was significantly different between grades (zero in Tönnis grade 0, four in Tönnis grade 1, and 10 in Tönnis grade 2; p < 0.001). The mean age at the time of surgery was also significantly older in osteoarthritic progression patients (p < 0.002). Kaplan-Meier survivorship analysis, with radiographic progression of osteoarthritis as the endpoint, predicted a 10-year survival rate of 100% in Tönnis grade 0, 85.7% in Tönnis grade 1, and 14.3% in Tönnis grade 2 (p < 0.001). CONCLUSIONS: The outcome of rotational acetabular osteotomy in most hips with Tönnis grade 0 and 1 was satisfactory after an average of 17 years of follow-up. The incidence of osteoarthritic progression was higher in Tönnis grade 2 and older age. Our results support that early joint preserving procedure is essential in the case of symptomatic dysplastic hips.


Asunto(s)
Acetábulo/cirugía , Luxación de la Cadera/cirugía , Osteoartritis de la Cadera/epidemiología , Osteotomía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Acetábulo/diagnóstico por imagen , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/mortalidad , Osteotomía/métodos , Osteotomía/mortalidad , Complicaciones Posoperatorias/mortalidad , Resultado del Tratamiento , Adulto Joven
20.
Arch Orthop Trauma Surg ; 138(9): 1223-1234, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29774386

RESUMEN

INTRODUCTION: It is likely that posterior-wall involvement in association with two-column fractures plays a pivotal role in outcomes because of the potential for hip instability if it is not anatomically reduced and fixed. Uncertainty remains about how this fracture is best treated, especially regarding how posterior-wall involvement may affect functional results. MATERIALS AND METHODS: To better understand the role that posterior-wall involvement may play in determining functional results, we compared data for outcomes for patients with posterior-wall involvement and for those without in a consecutive series of two-column fractures. Between 2000 and 2013, 42 patients who underwent surgical treatment for two-column acetabular fractures were evaluated after a minimum follow-up period of 1 year. Data were prospectively collected and retrospectively evaluated. Of the 42 patients, 25 had only a two-column fracture (group 1) and 17 had a two-column fracture with posterior-wall involvement (group 2). RESULTS: There were no differences between groups in terms of reduction accuracy, radiographic results, clinical results, or complication rates. All hips in patients with internal fixation for the associated posterior-wall fracture had anatomical reduction. At the latest follow-up evaluation, three patients from group 1 (without posterior-wall involvement) and three patients from group 2 (with posterior-wall involvement) had undergone total hip arthroplasty. CONCLUSION: These results suggest that a posterior-wall fracture in a two-column fracture does not compromise functional outcomes when the treatment algorithm discussed here is followed.


Asunto(s)
Acetábulo/lesiones , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Acetábulo/cirugía , Adolescente , Adulto , Anciano , Placas Óseas/efectos adversos , Tornillos Óseos/efectos adversos , Femenino , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...