Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Arthroplast Today ; 28: 101458, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39100413

RESUMEN

Background: Stem anteversion plays a crucial role in mitigating postoperative complications in total hip arthroplasty (THA). The application of the combined-anteversion theory in THA necessitates the intraoperative measurement of the stem anteversion angle (SAA). However, estimating SAA intraoperatively poses challenges for surgeons lacking a computer-assisted navigation system. In this study, we assessed the precision of intraoperative SAA measurements using a recently developed device, comparing them with 3-dimensional measurements obtained from postoperative computed tomography. Methods: We examined 127 hips in 127 patients who underwent unilateral THA at our institution. Employing our newly constructed device, attachable to rasping broach handles, we measured the SAA intraoperatively. This process involved incorporating the correction angle derived from the preoperative epicondylar view. We then compared the postoperative SAA with the intraoperative measurements, both with and without the correction angle, to ascertain the device's utility. Results: The device yielded an intraoperative SAA measurement of 17.93 ± 7.53°. In contrast, the true SAA measured on postoperative computed tomography was 26.40 ± 9.73°. The discrepancy between intraoperative and true SAA was 8.94 ± 5.44° (without the correction angle) and 4.93 ± 3.85° (with the correction angle). Accuracy within a discrepancy of <5° was achieved in 77 cases (60.6%), and <10° was achieved in 113 cases (89.0%). The accuracy remained consistent regardless of the stem-placement angle (varus/valgus, or flexion/extension) or the presence of ipsilateral knee osteoarthritis. Conclusions: The SAA-measuring device, attachable to various rasping handles, proves useful for straightforward, cost-effective, and noninvasive intraoperative SAA measurement during THA.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39105837

RESUMEN

BACKGROUND: Perioperative bleeding in total hip arthroplasty (THA) can lead to various problems, so effective management of blood loss is needed. This prospective, single-blind, randomized controlled trial aimed to compare the efficacy of topical administration of SURGICEL® (a hemostatic agent of oxidized regenerated cellulose) powder (SP) and tranexamic acid (TXA) in controlling perioperative bleeding during THA. MATERIALS AND METHODS: In total, 114 patients undergoing THA for osteoarthritis were randomized to either group S (THA with SP) or group T (THA with TXA). Data including patient demographics, laboratory data (C-reactive protein [CRP], hemoglobin, and hematocrit), operative time, and intraoperative blood loss were analyzed. Clinical outcomes were assessed using WOMAC, JOA, FJS scores, and visual analog scale (VAS) scores. Primary outcomes were estimated total and postoperative blood loss, while secondary outcomes included hematological test results and various clinical scores. RESULTS: 57 patients were allocated to each group, with 55 in group S and 56 in group T were finally included in the analysis. There was no significant difference (p = 0.141) in estimated total blood loss between group S (788.2 ± 350.1 ml) and group T (714.1 ± 318.4 ml). Hemoglobin and hematocrit levels and WOMAC, and FJS scores were not significantly different between the two groups at any time point. CRP levels were significantly different on postoperative days 4 and 7, and JOA score was significantly different on preoperative and postoperative period. However, the differences in CRP and JOA score values themselves were relatively small and not clinically different. CONCLUSIONS: Topical administration of SP is as effective as TXA in reducing perioperative bleeding in patients undergoing THA. Additionally, no significant difference was observed in early postoperative clinical outcomes between SP and TXA. LEVEL OF EVIDENCE: Therapeutic Level I. TRIAL REGISTRATION: The University Hospital Medical Information Network (UMIN) registration number UMIN000047607.

3.
Arthroplast Today ; 27: 101433, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38946925

RESUMEN

Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty. Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems. Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years. Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics.

4.
J Clin Med ; 13(11)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38893007

RESUMEN

Background/Objectives: A highly porous titanium cup with a three-dimensional metal interface was recently introduced to improve biological fixation and survival. However, radiography has revealed concerns regarding these cups, despite their excellent short- and mid-term clinical outcomes. This study compared the clinical and radiographic results of a highly porous titanium cup with those of a hydroxyapatite-coated porous titanium cup after primary total hip arthroplasty (THA). Methods: Fifty-one primary THAs were investigated. A highly porous titanium cup was used in 17 hips, and a hydroxyapatite-coated porous titanium cup was used in 34 hips. No significant differences in preoperative patient demographic characteristics were observed between the two groups. The 2-year postoperative clinical and radiographic results were compared. Results: Radiolucent lines were observed in 13 (76%) of 17 hips with highly porous titanium cups and in none (0%) of 34 hips with hydroxyapatite-coated porous titanium cups (p < 0.001). In the highly porous titanium cup group, radiolucent lines were observed in five hips (29%) in one zone, two hips (11%) in two zones, and six hips (35%) in three zones. No cup loosening was observed in either group. Conclusions: Radiolucent lines were significantly more frequent in highly porous titanium cups. This study suggests that, compared to the three-dimensional structure of porous titanium, the hydroxyapatite coating of porous titanium had a greater influence on bone ingrowth in the short term. The meaning of these findings in the long-term is unclear yet.

5.
Bone Joint J ; 106-B(6): 548-554, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38821498

RESUMEN

Aims: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.


Asunto(s)
Absorciometría de Fotón , Artroplastia de Reemplazo de Cadera , Densidad Ósea , Materiales Biocompatibles Revestidos , Hueso Cortical , Durapatita , Fémur , Prótesis de Cadera , Diseño de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Fémur/cirugía , Hueso Cortical/cirugía
6.
Arch Orthop Trauma Surg ; 144(6): 2865-2872, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38753013

RESUMEN

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.


Asunto(s)
Acelerometría , Acetábulo , Artroplastia de Reemplazo de Cadera , Sistemas de Navegación Quirúrgica , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Estudios Retrospectivos , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Masculino , Femenino , Anciano , Persona de Mediana Edad , Acelerometría/métodos , Acelerometría/instrumentación , Posicionamiento del Paciente/métodos , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Prótesis de Cadera , Tomografía Computarizada por Rayos X/métodos
7.
Adv Orthop ; 2024: 6645361, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38715703

RESUMEN

Objective: The patient's knee implant performance (PKIP) is a patient-reported outcome measure, developed in the USA in English that evaluates knee functional performance before and after primary total knee arthroplasty (TKA). The PKIP assesses the level of satisfaction, confidence, and stability, while performing various activities, as well as the need for changing ways of doing activities. It comprises 24 items. The objective of this study was to present the methodology of the linguistic validation of the PKIP. Methods: The Japanese version of the PKIP was developed using a standard linguistic validation (LV) process. The LV involved the following steps: (1) conceptual analysis of the original version; (2) translation into Japanese using a dual forward/backward translation process; (3) review by an orthopaedics surgeon; (4) test on five respondents; and (5) proofreading. Results: The translation itself did not reveal major translatability issues, either cultural, semantic, or syntactic. Most of the activities listed (e.g., going up stairs, getting in/out of a car, and walking up a hill/ramp/incline) were easily translated. Only one activity was culturally sensitive and raised some discussion, i.e., "sitting down on a toilet," since the style of Japanese toilets is different from the western style. Overall, the respondents well understood the questionnaire. However, the expression "how your knee is working with your body" used in the opening sentence was an issue for both the clinician and the respondents. A compromise was found by using a Japanese equivalent of "how your knee functions with your legs." Conclusion: The rigorous translation process, which involved the collaboration of a minimum of thirteen people (sponsor, four translators, two coordinators (one in Japan and one in Europe), one clinician, and five respondents) enabled the production of a Japanese version of the PKIP conceptually equivalent to the USA English original.

8.
Eur J Orthop Surg Traumatol ; 34(4): 2041-2047, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38517525

RESUMEN

PURPOSE: This study aimed to compare bone mineral density (BMD) changes around the femoral component after total hip arthroplasty (THA) in a fully hydroxyapatite-coated stem (CORAIL) and in a tapered-wedge stem (Taperloc complete) and identify predictors of BMD changes. METHODS: This retrospective study compared 43 hips in the CORAIL group and 40 hips in the Taperloc group. The relative changes in BMD at 2 years after THA measured using dual-energy X-ray absorptiometry and the three-dimensional quantified contact states of the stem with the femoral cortical bone were assessed. Predictors of the relative change in the BMD around the proximal part of the stem were examined using multiple regression analysis. RESULTS: The decrease in BMD in Gruen zone 7 was significantly less in the CORAIL group than in the Taperloc group (P = 0.02). In the CORAIL group, the contact area in any zone was not a significant predictor of the relative changes in BMD. The contact area between the Taperloc stem and the femoral cortical bone in zones 2 and 6 was a positive predictor of the relative changes in BMD in zones 1 (P = 0.02 and P = 0.04, respectively) and 2 (P = 0.008 and P = 0.004, respectively). CONCLUSION: The CORAIL stem suppressed the postoperative BMD loss around the stem, irrespective of the contact state. The Taperloc complete stem required contact with the proximal femoral metaphysis to suppress the postoperative BMD loss around the stem.


Asunto(s)
Absorciometría de Fotón , Artroplastia de Reemplazo de Cadera , Densidad Ósea , Remodelación Ósea , Durapatita , Fémur , Prótesis de Cadera , Diseño de Prótesis , Humanos , Masculino , Femenino , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Remodelación Ósea/fisiología , Persona de Mediana Edad , Anciano , Fémur/cirugía , Fémur/diagnóstico por imagen , Materiales Biocompatibles Revestidos
9.
J Arthroplasty ; 39(8): 2082-2087, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38360279

RESUMEN

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Densidad Ósea , Durapatita , Cuello Femoral , Prótesis de Cadera , Diseño de Prótesis , Humanos , Masculino , Femenino , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/instrumentación , Persona de Mediana Edad , Anciano , Cuello Femoral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Materiales Biocompatibles Revestidos
10.
Knee ; 46: 108-116, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38071923

RESUMEN

BACKGROUND: One of the remaining issues in total knee arthroplasty (TKA) is achieving sufficient rotational arc during deep flexion range of the knee for specific postures such as the 'seiza' or cross-legged sitting. This study aimed to evaluate whether there was a change in the actual in vivo rotational arc during deep flexion range before and after a design change of polyethylene (PE) inserts. METHODS: In 50 posterior-stabilised TKA cases, knee kinematics, including rotational movement, were measured intraoperatively using an image-free navigation system to compare a newly designed PE insert with reduced the posterior lip with a conventional PE insert. Femoral-tibial rotational angles at 30°, 45°, 60°, 90°, 120°, and 130° knee flexion were evaluated. Varus/valgus instability, knee range of motion, and femoral rollback were also measured. Obtained parameters were compared between new and conventional PE inserts. The independent factors associated with rotational arc during deep flexion range (120° and 130° knee flexion) were analysed using multivariate analysis. RESULTS: The newly designed PE insert demonstrated a significant increase in the rotational arc at 120° (22.9 ± 8.7° vs. 30.1 ± 11.9°, P < 0.001) and 130° (24.3 ± 9.5° vs. 32.5 ± 12.4°, P < 0.001) knee flexion compared with that with the conventionally designed posterior-stabilised insert. Multivariate analysis demonstrated that using the newly designed PE insert was an independent predictor of improved rotational arc during deep flexion range: regression coefficient was 11.2 (95% confidence interval 7.1-15.3, P < 0.001). CONCLUSION: The design change, which reduced the posterior lip of the PE insert, contributed to improved rotational arc in 120° and 130° deep flexion ranges.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Polietileno , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Rango del Movimiento Articular , Fenómenos Biomecánicos
11.
Hip Int ; 34(1): 57-65, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37293785

RESUMEN

AIM: This study aimed to assess the relationship between the three-dimensional (3D) alignment of short tapered-wedge cementless stems and bone mineral density (BMD) changes in patients followed up for 5 years after total hip arthroplasty (THA). METHODS: We retrospectively analysed the hips of 52 patients who underwent THA using short tapered-wedge cementless stems at our institution from 2013 to 2016 with complete 5-year follow-up data. We evaluated the relationship between stem alignment, measured using a 3D-templating software, and BMD changes in the 7 Gruen zones. RESULTS: After 1 year, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD in zones 3 and 4 were noted. After 5 years, significant negative correlations between varus insertion and a decrease in BMD in zone 7 and between flexed insertion and decreases in BMD zones 2, 3, and 4 were observed. With increased amounts of varus/flexion stem alignment, the amount of BMD loss decreased. There was no correlation between anteverted stem insertion and changes in BMD levels. CONCLUSIONS: Our data showed that stem alignment affects BMD based on 5-year follow-up data after surgery. Careful observation is necessary, especially when using short tapered-wedge cementless stems, as stem alignment may affect changes in BMD levels more than 5 years after surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Densidad Ósea , Estudios Retrospectivos , Diseño de Prótesis , Fémur/cirugía
12.
J Shoulder Elbow Surg ; 33(1): 181-191, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37598837

RESUMEN

BACKGROUND: Dislocation is a major complication of reverse total shoulder arthroplasty (RSA). The humeral liner may be changed to a constrained type when stability does not improve by increasing glenosphere size or lateralization with implants, and patients, particularly women with obesity, have risks of periprosthetic instability that may be secondary to hinge adduction on the thorax, but there are few reports on its impact on the range of motion (ROM). This study aimed to determine the influence of humeral liner constraint on impingement-free ROM and impingement type using an RSA computer simulation model. METHODS: A virtual simulation model was created using 3D measurement software for conducting a simulation study. This study included 25 patients with rotator cuff tears and rotator cuff tear arthropathy. Impingement-free ROM and impingement patterns were measured during flexion, extension, abduction, adduction, external rotation, and internal rotation. Twenty-five cases with a total of 4 patterns of 2 multiplied by 2, making a total of 100 simulations: glenosphere (38 mm normal type vs. lateralized type) and humeral liner constraint (normal type vs. constrained type). There were 4 combinations: normal glenosphere and normal humeral liner, normal glenosphere and constrained humeral liner, lateralized glenosphere and normal humeral liner, and lateralized glenosphere and constrained humeral liner. RESULTS: Significant differences were found in all impingement-free ROM in 1-way analysis of variance (abduction: P = .01, adduction: P < .01, flexion: P = .01, extension: P = .02, external rotation: P < .01, and internal rotation: P < .01). Tukey's post hoc tests showed that the impingement-free ROM was reduced during abduction, external rotation, and internal rotation with the combination of the normal glenosphere and constrained humeral liner compared with the other combinations, and improved by glenoid lateralization compared with the combination of the lateralized glenosphere and constrained humeral liner. In the impingement pattern, the Pearson χ2 test showed significantly greater proportion of impingement of the humeral liner into the superior part of the glenoid neck in abduction occurring in the combination of the normal glenosphere and constrained humeral liner group compared with the other groups (P < .01). Bonferroni post hoc tests revealed that the combination of the normal glenosphere and constrained humeral liner was significantly different from that of the lateralized glenosphere and constrained humeral liner (P < .01). Using constrained liners resulted in early impingement on the superior part of the glenoid neck in the normal glenosphere, whereas glenoid lateralization increased impingement-free ROM. CONCLUSION: This RSA computer simulation model demonstrated that constrained humeral liners led to decreased impingement-free ROM. However, using the lateralized glenosphere improved abduction ROM.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Femenino , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Simulación por Computador , Diseño de Prótesis , Húmero/cirugía , Rango del Movimiento Articular
13.
Prog Rehabil Med ; 8: 20230027, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37705509

RESUMEN

Objectives: Patients with severe coronavirus disease 2019 (COVID-19) who develop pneumonia face the risk of ventilatory muscle disuse in the acute phase, which can result in persistent respiratory impairments in the subacute phase. Although rehabilitation during the acute phase is considered effective, there are limited reports on this topic. Therefore, this study aimed to investigate the effectiveness of acute-phase rehabilitation in patients with severe COVID-19. Methods: The study included 57 patients (45 men and 12 women; mean age: 63.2±12.1 years) admitted between April and June 2021, all of whom required intubation for respiratory management. Among them, 34 patients underwent acute-phase rehabilitation interventions based on the early goal-directed mobilization protocol. The primary objectives were to assess the occurrence of medical accidents related to acute-phase rehabilitation and evaluate their impact on survival and mobility upon hospital discharge. Statistical techniques and machine learning algorithms were employed for data analysis. Results: Remarkably, no medical accidents occurred during the acute-phase rehabilitation among the patients. Furthermore, our findings indicated that acute-phase rehabilitation did not influence survival outcomes. However, it did have a positive impact on the mobility of patients upon hospital discharge. Conclusions: Acute-phase rehabilitation can be safely administered to patients with severe COVID-19 by following an early goal-directed mobilization protocol. This approach may also contribute to improved activities of daily living after discharge.

14.
Arch Orthop Trauma Surg ; 143(11): 6781-6790, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37418005

RESUMEN

INTRODUCTION: It is preferable to reduce postoperative excessive rotational mismatch between the femur and tibia that causes poor clinical results following total knee arthroplasty (TKA). The aim of this study is to compare postoperative rotational mismatches and clinical outcomes with mobile- and fixed-bearing prostheses. MATERIALS AND METHODS: This study classified 190 TKAs into two groups equally by propensity score matching: mobile-bearing group (n = 95) and fixed-bearing group (n = 95). Computed tomography images of the whole leg were taken at 2 weeks postoperatively. The component alignments, rotational mismatches between the femur and tibia, and rotations among components were measured three-dimensionally. The knee range of motion, New Knee Society Score (KSS) subjective sores, and Forgotten Joint Score (FJS-12) were assessed at the final follow-up. RESULTS: Rotational mismatch between the femur and tibia was significantly less in the mobile- (- 0.8° ± 7.3°) than in the fixed-bearing (3.3° ± 8.5°, p < 0.001) group. New KSS functional activity score was significantly poorer in patients with excessive rotational mismatch (61.3 ± 21.4) than in those without it (49.5 ± 20.6, p = 0.02). Comparing mobile-bearing prosthesis, the use of fixed-bearing prosthesis was a risk factor for postoperative excessive rotational mismatch (odds ratio: 2.32, p = 0.03). CONCLUSION: When compared to a fixed-bearing prosthesis, TKA using a mobile-bearing prosthesis could suppress the postoperative rotational mismatch between the femur and tibia that causes poor subjective functional activity score. However, since this study was conducted for PS-TKA, the results might not be applicable to other models.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/cirugía , Diseño de Prótesis , Rango del Movimiento Articular , Medición de Resultados Informados por el Paciente
15.
Arthroplasty ; 5(1): 27, 2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37202793

RESUMEN

BACKGROUND: The newly-designed alumina ceramic medial pivot total knee prosthesis was introduced to reduce polyethylene wear and better fit the anatomical morphology of the Asian population. This study aimed to clarify the long-term clinical results of alumina medial pivot total knee arthroplasty over a minimum follow-up period of 10 years. METHODS: The data of 135 consecutive patients who underwent primary alumina medial pivot total knee arthroplasty were analyzed in this retrospective cohort study. Patients were examined over a minimum 10-year follow-up period. The knee range of motion, Knee Society Score (KSS) knee score, Knee Society Score function score, and radiological parameters were assessed. The survival rate was also evaluated by using reoperation and revision as endpoints. RESULTS: The mean follow-up period lasted 11.8 ± 1.4 years. Patients who were not followed accounted for 7.4% of the total cohort. Knee and function scores of KSS improved significantly following total knee arthroplasty (P < 0.001). In 27 individuals (28.1%), a radiolucent line was observed. Aseptic loosening occurred in three cases (3.1%). The survival rates for reoperation and revision were 94.8% and 95.8% 10 years after the operation, respectively. CONCLUSIONS: During a minimum 10-year follow-up period, the present model of alumina medial pivot total knee arthroplasty showed good clinical outcomes and survival rates.

16.
Arch Orthop Trauma Surg ; 143(10): 6345-6351, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37103606

RESUMEN

INTRODUCTION: Previous reports using cadaveric knees and musculoskeletal computer simulation have shown that kinematically aligned (KA) total knee arthroplasty (TKA) provides more natural and physiological tibiofemoral kinematic patterns than mechanically aligned (MA) TKA. These reports suggested that the modification of joint line obliquity improve the knee kinematics. This study aimed to determine whether joint line obliquity change the intraoperative tibiofemoral kinematics in TKA candidates with knee osteoarthritis. METHODS: Thirty consecutive knees with varus osteoarthritis that underwent TKA using a navigation system were evaluated. Two types of trial components were prepared: (1) MA TKA model: component trial in which articulating surface was parallel to the bone cut surface (2) KA TKA model: the femoral component trial, which mimicked the KA TKA method of Dossett et al. was designed 3° valgus and 3° internal rotation to the femoral bone cut surface, and the tibial component trial was designed 3° varus to the tibial bone cut surface. These two trials were set on the same knees during the operation, and the tibiofemoral rotational kinematics and varus-valgus laxity were measured from 0° to 120° of knee flexion using a navigation system. RESULTS: The joint gap was 20 ± 2 mm and 3° ± 1° varus in extension and 20 ± 2 mm and 3° ± 1°varus in flexion. The differences in femoral component rotation between KA TKA and MA TKA were not statistically significant for any knee flexion angle. The differences in varus-valgus laxity between KA TKA and MA TKA were also not statistically significant for any knee flexion angle. CONCLUSION: Although the degree of joint line obliquity varies widely in various KA TKA methods, this study, which mimicked the method of Dossett et al. showed that the modification of joint line obliquity did not change the tibiofemoral kinematics and stability of the knee joint in TKA candidates with knee osteoarthritis.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Fenómenos Biomecánicos , Simulación por Computador , Articulación de la Rodilla/cirugía , Tibia/cirugía , Rango del Movimiento Articular/fisiología
17.
J Bone Joint Surg Am ; 105(5): 345-353, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36856692

RESUMEN

BACKGROUND: Perioperative essential amino acid (EAA) supplementation suppresses lower-limb muscle atrophy and promotes functional improvement in the first 4 weeks after total knee arthroplasty (TKA). However, its effect on the recovery of muscle volume and strength in the intermediate term is unclear. The aim of this study was to evaluate the effect of perioperative EAA supplementation on the recovery of lower-limb muscle volume and strength in the 2 years after TKA. METHODS: Sixty patients who underwent unilateral TKA for primary knee osteoarthritis were included in this double-blinded randomized controlled trial. After excluding dropouts, 26 patients assigned to the EAA group (9 g/day) and 26 assigned to the placebo group (powdered lactose, 9 g/day) were available for analysis. Patients received EAA supplementation or a placebo from 1 week prior to surgery to 2 weeks after it. The rectus femoris muscle area was measured using ultrasonography and quadriceps muscle strength was measured isometrically with a handheld dynamometer, preoperatively and periodically up to 2 years postoperatively. Knee pain, knee range of motion, functional mobility, and Knee Society Score 2011 subjective scores were measured at each time point. Perioperative management, except for supplementation, was identical in the 2 groups. RESULTS: Taking the baseline as 100%, the mean values in the EAA and placebo groups were 134% ± 31% and 114% ± 27%, respectively, for the rectus femoris muscle area and 159% ± 54% and 125% ± 40% for the quadriceps muscle strength, respectively, at 2 years after surgery. The differences were significant (p < 0.05). Clinical outcomes were not significantly different between the 2 groups. CONCLUSIONS: Perioperative EAA supplementation contributes to the recovery of rectus femoris muscle volume and quadriceps muscle strength in the 2 years after TKA. The EAA supplementation did not impact clinical outcomes. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Músculo Cuádriceps , Humanos , Extremidad Inferior , Aminoácidos Esenciales , Suplementos Dietéticos
18.
SICOT J ; 9: 2, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36648275

RESUMEN

PURPOSE: The relationship between spinopelvic mobility and dislocation in total hip arthroplasty (THA) has recently attracted attention. This study aimed to investigate the differences in sacral slope (SS) between two types of upright seated positions and to determine which seated position was appropriate for assessing spinopelvic mobility (change in SS from standing to sitting) before THA. MATERIALS AND METHODS: This prospective cohort study included 75 hips from 75 patients who had undergone primary THA. Each patient underwent preoperative lateral spinopelvic radiography in standing (st) and two seated positions: relaxed (rs) and straight (ss). The change in SS between each position (Δ) was measured. RESULTS: Differences in all spinopelvic sagittal alignment parameters between the two seated positions were statistically significant (p < 0.001). The range, median, and mean values of ΔSSss-rs were -2.0° to 26.5°, 6.8°, and 8.3°, respectively. ΔSSss-rs was significantly correlated with SS, LLA, and PFA in the relaxed seated position (r = -0.52, -0.39, and 0.37; p < 0.001, p < 0.001, and p = 0.001, respectively), but was not correlated to these parameters in the straight seated position. Of the 52 patients with normal spinopelvic mobility in the relaxed seated position (ΔSSst-rs > 10°), 24 (46%) patients were misrepresented as having a stiff spine in the straight seated position (ΔSSst-ss < 10°). CONCLUSION: The change in SS from the straight to the relaxed seated position widely varied in patients before THA. The spinopelvic radiograph in the relaxed seated position is appropriate when evaluating spinopelvic mobility for preoperative planning.

19.
Arch Orthop Trauma Surg ; 143(7): 4465-4472, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36261646

RESUMEN

INTRODUCTION: It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS: Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS: The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (ß = 0.41, p < 0.01) and stem coronal alignment (ß = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION: The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Durapatita , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/métodos , Tomografía Computarizada por Rayos X/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/cirugía , Diseño de Prótesis
20.
Arch Orthop Trauma Surg ; 143(7): 4473-4480, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36322198

RESUMEN

INTRODUCTION: No studies have compared the accuracy of acetabular cup placement in total hip arthroplasty (THA) in the supine and lateral decubitus positions using the same portable navigation system. Thus, this study aimed to compare the accuracy of acetabular cup placement using a new accelerometer-based portable navigation system combined with an infrared stereo camera and inertial measurement unit between the supine and lateral decubitus positions. MATERIALS AND METHODS: This retrospective study compared 45 THAs performed in the supine position (supine group) and 44 THAs performed in the lateral decubitus position (lateral group) using the same portable navigation system. The primary outcome was the absolute errors of cup placement angles, defined as the absolute values of the differences between cup radiographic inclination and anteversion angles displayed on the navigation system and those measured on postoperative computed tomography images. RESULTS: No significant difference in the median absolute error of the cup inclination angle (supine group 1.7° [interquartile range 0.8°-3.1°] vs. lateral group 2.1° [interquartile range 1.0°-3.7°]; p = 0.07) was found between the two groups. Similarly, no significant difference in the median absolute error of the anteversion angle (supine group 1.9° [interquartile range 0.8°-3.4°] vs. lateral group 2.1° [interquartile range 0.9°-3.1°]; p = 0.42) was found. CONCLUSION: This new accelerometer-based portable navigation system may provide high accuracy of the cup placement in THA in the lateral decubitus and supine positions.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirugía Asistida por Computador , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Posición Supina , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Acelerometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA