Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38727556

RESUMEN

Introduction: Hiatal hernia (HH) is a common disorder of the upper gastrointestinal (UGI) tract that general surgeons encounter. Giant paraesophageal is a subtype of HH in which more than 30% of the stomach is located in the chest. It can cause symptoms such as dysphagia, UGI bleeding, gastroesophageal reflux disease, and vomiting. As the life expectancy of the general population increases, the incidence of giant HH increases and can cause morbidity, including recurrent admissions and prolonged length of hospitalization. In this article, we describe a cohort of nonagenarian patients with HH who were admitted to our institution and were treated either surgically or medically. Methods: We retrospectively reviewed our prospectively maintained database of all nonagenarians who were admitted to our center between 2018 and 2022 with the diagnosis of HH. We compared the demographic data, clinical data, and outcomes between patients undergoing operative and nonoperative management. Results: Twenty patients of age over 90 years were hospitalized with HH-related symptoms. Six underwent surgery, whereas 14 received medical management. Surgical patients had fewer overall hospitalization days, shorter length of stay, and less blood product requirements. Notably two cases of in-hospital mortality occurred in the nonoperative group, whereas none occurred in the operative group. All surgical procedures were performed laparoscopically, with two minor perioperative complications. Conclusion: In selected nonagenarian patients, laparoscopic HH repair is safe and should be considered favorably. It can reduce hospitalization time and can mitigate morbidity.

2.
J Robot Surg ; 18(1): 71, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38340240

RESUMEN

Surgeons performing robotic-assisted laparoscopic surgery experience physical stress and overuse of shoulder muscles due to sub-optimal arm support during surgery. The objective is to present a novel design and prototype of a dynamic arm support for robotic laparoscopic surgery to evaluate its ergonomics and performance on the AdLap-VR simulation training device. The prototype was designed using the mechanical engineering design process: Technical requirements, concept creation, concept selection, 3D-design and built of the prototype. A crossover study was performed on a marble sorting task on the AdLap-VR. The first group performed four trials without the arm support, followed by four trials with the arm support, and the other group executed the sequence vice versa. The performance parameters used were time to complete (s), path length (mm), and the number of collisions. Afterward, the participants filled out a questionnaire on the ergonomic experience regarding both situations. 20 students executed 160 performed trials on the AdLap-VR Significant decreases in the subjective comfort parameters mental demand, physical demand, effort and frustration were observed as a result of introducing the novel arm support. Significant decreases in the objective performance parameters path length and the number of collisions were also observed during the tests. The newly developed dynamic arm support was found to improve comfort and enhance performance through increased stability on the robotic surgery skills simulator AdLap-VR.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Cruzados , Brazo/cirugía , Competencia Clínica
3.
Surg Endosc ; 38(3): 1180-1190, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38082007

RESUMEN

BACKGROUND: Achalasia is a rare disorder of the esophagus characterized by motor dysfunction in the esophagus and relaxation failure of the lower esophageal sphincter (LES). Currently, surgical myotomy procedures are considered the standard of care. Robotic Heller's myotomy (RHM) with fundoplication has been gaining popularity due to documented advantages in the precision of myotomy as well as avoiding the potential reflux following per-oral endoscopic myotomy (POEM). To the best of our knowledge, RHM has thus far has been performed exclusively by the da Vinci surgical system. The new Hugo RAS™ system offers a unique modular design and an open console which offers better maneuverability and docking options. In this study, we present the first worldwide series of patients undergoing RHM using the new Hugo RAS™ platform. Our objective is to propose optimal operating configuration and setup to fully harness the advantages of the unique modular design of this system. METHODS: Ten consecutive achalasia patients underwent Robotic Heller's myotomy (RHM) with the Hugo RAS™ system. We prospectively collected patient data, including demographics, comorbidities, ASA class, Eckardt scores, pre-operative manometric data, and EndoFlip parameters. Additionally, we recorded the docking and total operative times. RESULTS: Between December 2022 and August 2023, 10 patients underwent RHM with the Hugo™ RAS system. Patients had a median age of 42.5 years, 60% were female, and mean BMI was 23.2. Fifty percent had achalasia type 2 and 50% type 1. The median pre-operative integrated relaxation pressure (IRP) was 24.9. Median docking time was 10 min and overall operative time was 129.5 min. All patients, except one with acute coronary syndrome, had an uneventful peri-operative course and were discharged on post-operative day 2. CONCLUSION: The Hugo™ RAS system is well designed for robotic Heller myotomy. The operative and clinical results are similar to the currently used robotic system; however, the modular design of the system has some differences. These translate to better docking angles and maneuverability as well as console surgeon's ergonomics. Further experience is needed to explore the advantages of the system's modular design and function.


Asunto(s)
Acalasia del Esófago , Miotomía de Heller , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Humanos , Femenino , Adulto , Masculino , Acalasia del Esófago/cirugía , Resultado del Tratamiento , Laparoscopía/métodos , Esfínter Esofágico Inferior/cirugía
4.
Surg Endosc ; 38(2): 488-498, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38148401

RESUMEN

BACKGROUND: Minimally invasive total gastrectomy (MITG) is a mainstay for curative treatment of patients with gastric cancer. To define and standardize optimal surgical techniques and further improve clinical outcomes through the enhanced MITG surgical quality, there must be consensus on the key technical steps of lymphadenectomy and anastomosis creation, which is currently lacking. This study aimed to determine an expert consensus from an international panel regarding the technical aspects of the performance of MITG for oncological indications using the Delphi method. METHODS: A 100-point scoping survey was created based on the deconstruction of MITG into its key technical steps through local and international expert opinion and literature evidence. An international expert panel comprising upper gastrointestinal and general surgeons participated in multiple rounds of a Delphi consensus. The panelists voted on the issues concerning importance, difficulty, or agreement using an online questionnaire. A priori consensus standard was set at > 80% for agreement to a statement. Internal consistency and reliability were evaluated using Cronbach's α. RESULTS: Thirty expert upper gastrointestinal and general surgeons participated in three online Delphi rounds, generating a final consensus of 41 statements regarding MITG for gastric cancer. The consensus was gained from 22, 12, and 7 questions from Delphi rounds 1, 2, and 3, which were rephrased into the 41 statetments respectively. For lymphadenectomy and aspects of anastomosis creation, Cronbach's α for round 1 was 0.896 and 0.886, and for round 2 was 0.848 and 0.779, regarding difficulty or importance. CONCLUSIONS: The Delphi consensus defined 41 steps as crucial for performing a high-quality MITG for oncological indications based on the standards of an international panel. The results of this consensus provide a platform for creating and validating surgical quality assessment tools designed to improve clinical outcomes and standardize surgical quality in MITG.


Asunto(s)
Neoplasias Gástricas , Humanos , Técnica Delphi , Consenso , Neoplasias Gástricas/cirugía , Reproducibilidad de los Resultados , Escisión del Ganglio Linfático , Anastomosis Quirúrgica , Gastrectomía
5.
Surg Endosc ; 37(11): 8552-8561, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37794124

RESUMEN

BACKGROUND: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator that are used during surgery influence gas leakage. Therefore, this study compares particle escape from a valveless (Conmed AirSeal iFS), and a conventional (Karl Storz Endoflator) system. MATERIALS AND METHODS: Using an in vitro model, a conventional and a valveless trocar system were compared. A protocol that simulated various surgical phases was defined to assess the surgical conditions and particle leakage. Insufflation pressures and instrument diameters were varied as these are known to affect gas leakage. RESULTS: The conventional trocar leaked during two distinct phases. Removal of the obturator caused a sudden release of particles. During instrument insertion, an average of 211 (IQR 111) particles per second escaped when using the 5 mm diameter instrument. With the 10 mm instrument, 50 (IQR 13) particles per second were measured. With the conventional trocar, a higher abdominal pressure increased particle leakage. The valveless trocar demonstrated a continuously high particle release during all phases. After the obturator was removed, particle escape increased sharply. Particle escape decreased to 1276 (IQR 580) particles per second for the 5 mm instrument insertion, and 1084 (IQR 630) particles per second for 10 mm instrument insertion. With the valveless trocar system, a higher insufflation pressure lowered particle escape. CONCLUSIONS: This study shows that a valveless trocar system releases more particles into the operating room environment than a conventional trocar. During instrument insertion, the leakage through the valveless system is 6 to 20 times higher than the conventional system. With a valveless trocar, leakage decreases with increasing pressure. With both trocar types leakage depends on instrument diameter.


Asunto(s)
Cavidad Abdominal , Insuflación , Laparoscopía , Humanos , Laparoscopía/métodos , Humo/efectos adversos , Instrumentos Quirúrgicos , Insuflación/métodos
6.
Minim Invasive Ther Allied Technol ; 32(6): 300-306, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37603037

RESUMEN

INTRODUCTION: Robotic-assisted surgery has been a part of surgical procedures for more than two decades. Recently new robotic platforms with a different design entered the market. The modular design with independent arms enables increased flexibility of arm docking to increase the range of motion and instrument maneuverability. We herein present the first case series of robotic inguinal hernia repair using the Hugo RAS system (Medtronic, Minneapolis, MN, USA). MATERIAL AND METHODS: Thirteen inguinal hernia repairs were performed on ten patients. A description of the Hugo RAS system as well as the new concept of modular design is presented along with the description of the operation setup. RESULTS: Mean docking time was 9.5 min and mean console time was 50.3 min and 74.7 min for unilateral and bilateral inguinal hernia repair, respectively. No intraoperative or postoperative complications occurred. There was one conversion to laparoscopic surgery due to a technical issue with the robot. Conclusions: The modular design of independent arms seems to enhance maneuverability of the instruments and contribute to fewer arm collisions. Further clinical data and experience with this new surgical system are necessary to understand if this new design has advantages over the standard robotic platforms.


Asunto(s)
Hernia Inguinal , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Hernia Inguinal/cirugía , Laparoscopía/métodos , Complicaciones Posoperatorias , Herniorrafia/métodos , Estudios Retrospectivos
7.
J Gastrointest Surg ; 27(11): 2279-2286, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37620664

RESUMEN

BACKGROUND: Gastroesophageal reflux disease (GERD) is a common condition, resulting from the loss of the anti-reflux barrier. Laparoscopic fundoplication is the surgical procedure of choice for treatment of GERD; however, there remains a debate on the exact mechanism through which it prevents reflux. OBJECTIVES: Our aim was to understand the relationship between reflux, fundoplication, and the angle of His on an experimental model. METHODS: The study was conducted on four groups of fresh explanted swine stomachs: control group, myotomy, myotomy with Nissen fundoplication, and myotomy with Toupet fundoplication. The stomachs were placed in a specially designated container on an inclinable platform which would increase the hydrostatic pressure on the esophago-gastric junction. Measurements of the angle of His using fluoroscopy and the esophago-gastric orifice area using endoscopy were performed, and the occurrence of reflux was documented. RESULTS: Each group of the study contained nine swine stomachs. In the control and myotomy groups, the angle became wider as the incline level increased the pressure and was significantly different between the groups (p < .001). Both groups demonstrated an increase in the orifice area as the incline level increased the pressure. There was a significant correlation between the angle of His and the area of the esophago-gastric orifice (p < .001). In the control group, the reflux began at the 0°. In the myotomy group, it began at the + 15° incline (less pressure). Reflux rarely occurred in the Nissen and Toupet groups, with the breaking point being mostly defined as "beyond - 30°". A significant difference was noted in the occurrence of reflux between fundoplication and the non-fundoplication groups (p < 0.001), while there was no significant difference between the Toupet and Nissen groups (p = 0.134). Analysis showed a significant independent correlation between both the angle of His and the orifice area with the presence of reflux (p = .002 and p = .024 respectively). CONCLUSIONS: In this study, we developed an experimental model to enable careful evaluation of the elements of the anti-reflux mechanism, of which, the angle of His has a measurable element. We demonstrated that as the angle of His becomes wider the esophago-gastric orifice area becomes larger. Additionally, a wider angle of His and a larger esophago-gastric orifice area were correlated independently with more reflux. This suggests that the fundoplication creates an acute angle of His which is correlated with a smaller area of the esophago-gastric orifice and eventually with a lower incidence of reflux.


Asunto(s)
Reflujo Gastroesofágico , Laparoscopía , Humanos , Resultado del Tratamiento , Laparoscopía/métodos , Reflujo Gastroesofágico/prevención & control , Reflujo Gastroesofágico/cirugía , Fundoplicación/métodos
8.
Nat Biomed Eng ; 7(11): 1493-1513, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37550423

RESUMEN

The study of cardiac physiology is hindered by physiological differences between humans and small-animal models. Here we report the generation of multi-chambered self-paced vascularized human cardiac organoids formed under anisotropic stress and their applicability to the study of cardiac arrhythmia. Sensors embedded in the cardiac organoids enabled the simultaneous measurement of oxygen uptake, extracellular field potentials and cardiac contraction at resolutions higher than 10 Hz. This microphysiological system revealed 1 Hz cardiac respiratory cycles that are coupled to the electrical rather than the mechanical activity of cardiomyocytes. This electro-mitochondrial coupling was driven by mitochondrial calcium oscillations driving respiration cycles. Pharmaceutical or genetic inhibition of this coupling results in arrhythmogenic behaviour. We show that the chemotherapeutic mitoxantrone induces arrhythmia through disruption of this pathway, a process that can be partially reversed by the co-administration of metformin. Our microphysiological cardiac systems may further facilitate the study of the mitochondrial dynamics of cardiac rhythms and advance our understanding of human cardiac physiology.


Asunto(s)
Fenómenos Bioquímicos , Miocitos Cardíacos , Animales , Humanos , Miocitos Cardíacos/metabolismo , Arritmias Cardíacas , Contracción Miocárdica/fisiología , Organoides
9.
Nutrients ; 15(15)2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37571418

RESUMEN

Bariatric surgery (BS) can have negative effects on bone health. Bone microarchitecture quality evaluation using the trabecular bone score (TBS) has not been described in patients after sleeve gastrectomy (SG). To test the hypothesis that the TBS is clinically useful for this population, we evaluated changes in bone mineral density (BMD) and the TBS in a longitudinal cohort study following SG. The measurements before surgery and after 12 and 24 postoperative months were as follows: weight, height, BMI, waist circumference (WC), BMD and TBS. The results at baseline showed the following: a mean BMI of 43 ± 0.56, TBS of 1.25 ± 0.02, lumbar spine BMD T-score of -0.4 ± 0.93, TBS T-score of -2.30 ± 0.21, significantly lower than BMD-T-score, and associated with a BMD-T-TBS-T gap (T-gap) of -2.05 ± 1.26 (-0.24 ± 0.13). One year after surgery, the TBS had significantly improved (+12.12% ± 1.5), leading to a T-gap of -0.296 ± 0.14, which remained stable at 2 years post-surgery. A correlation analysis revealed a significant negative correlation between the T-gap and WC (r = -0.43 p = 0.004). Our interpretation is that abdominal fat may interfere with image acquisition via increased tissue thickness, leading to a false low TBS at baseline. In conclusion, TBS should be interpreted with caution in patients with obesity and elevated WC. Additionally, we show that after SG, the LS microarchitecture measured using the TBS is partially degraded in up to 25% of patients. Further studies are warranted to assess hip bone microarchitecture changes after bariatric surgery.


Asunto(s)
Densidad Ósea , Hueso Esponjoso , Humanos , Hueso Esponjoso/diagnóstico por imagen , Absorciometría de Fotón/métodos , Estudios Longitudinales , Estudios de Seguimiento , Vértebras Lumbares/diagnóstico por imagen
10.
Surg Endosc ; 37(9): 7325-7335, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37442835

RESUMEN

BACKGROUND: During laparoscopic surgery, CO2 insufflation gas could leak from the intra-abdominal cavity into the operating theater. Medical staff could therefore be exposed to hazardous substances present in leaked gas. Although previous studies have shown that leakage through trocars is a contributing factor, trocar performance over longer periods remains unclear. This study investigates the influence of prolonged instrument manipulation on gas leakage through trocars. METHODS: Twenty-five trocars with diameters ranging from 10 to 15 mm were included in the study. An experimental model was developed to facilitate instrument manipulation in a trocar under loading. The trocar was mounted to a custom airtight container insufflated with CO2 to a pressure of 15 mmHg, similar to clinical practice. A linear stage was used for prolonged instrument manipulation. At the same time, a fixed load was applied radially to the trocar cannula to mimic the reaction force of the abdominal wall. Gas leakage was measured before, after, and during instrument manipulation. RESULTS: After instrument manipulation, leakage rates per trocar varied between 0.0 and 5.58 L/min. No large differences were found between leakage rates before and after prolonged manipulation in static and dynamic measurements. However, the prolonged instrument manipulation did cause visible damage to two trocars and revealed unintended leakage pathways in others that can be related to production flaws. CONCLUSION: Prolonged instrument manipulation did not increase gas leakage rates through trocars, despite damage to some individual trocars. Nevertheless, gas leakage through trocars occurs and is caused by different trocar-specific mechanisms and design issues.


Asunto(s)
Cavidad Abdominal , Pared Abdominal , Laparoscopía , Humanos , Dióxido de Carbono , Pared Abdominal/cirugía , Instrumentos Quirúrgicos
11.
Indian J Gastroenterol ; 42(3): 431-435, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37115479

RESUMEN

Hypercontractile esophagus with concomitant esophagogastric junction outflow obstruction (EGJOO) is a rare entity that is characterized by both esophageal hypercontractility and lack of relaxation of the EGJ. The clinical characteristics of these patients are not well-described and there is no strict recommendation regarding the treatment of this condition. We report four cases of patients with hypercontractile esophagus and concomitant to EGJOO. All patients underwent upper gastrointestinal (GI) endoscopy, high-resolution esophageal manometry (HRM) and barium swallow and met the criteria of Chicago Classification for both EGJOO and hypercontractile esophagus. Patients were followed up to four years from diagnosis and clinical symptoms were recorded. Four patients, who underwent evaluation for dysphagia, were found to have both EGJOO and hypercontractile esophagus on HRM. Two of them had mild symptoms and did not undergo treatment with no progression of symptoms on follow-up. Of the two patients who underwent treatment, one had botulinum toxin injection to the EGJ via upper GI endoscopy and one underwent per-oral endoscopic myotomy. Symptoms in both patients improved. Patients with concomitant hypercontractile esophagus and EGJOO present with varying degrees of symptoms and the treatment approach should be personalized according to the degree of symptoms and general clinical condition.


Asunto(s)
Trastornos de Deglución , Trastornos de la Motilidad Esofágica , Enfermedades Musculares , Gastropatías , Humanos , Unión Esofagogástrica , Trastornos de la Motilidad Esofágica/complicaciones , Trastornos de la Motilidad Esofágica/diagnóstico , Trastornos de la Motilidad Esofágica/terapia , Manometría , Enfermedades Musculares/complicaciones
12.
J Gastrointest Surg ; 27(5): 878-886, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36720757

RESUMEN

BACKGROUND: Peroral endoscopic myotomy (POEM) is rapidly becoming the procedure of choice for treating esophageal achalasia. In most centers, contrast-enhanced swallow studies (CESS) are routinely performed postoperatively to confirm mucosal integrity. The aim of this study was to determine the necessity of performing these studies routinely after POEM. METHODS: A retrospective review of a prospectively maintained database of patients who underwent POEM between December 2012 and November 2020 was performed. All patients underwent a CESS on the first postoperative day. Medical records including vital signs, complete blood count, and POD-1 CESS were evaluated. RESULTS: One hundred thirty-four consecutive patients were included in the study. Sixty-nine (51.49%) CESS showed abnormal findings; while most findings did not change the postoperative course, five (7.2%) demonstrated tunnel leaks, which did alter the overall management. Screening patients for fever, tachycardia, or leukocytosis on POD-1 had a 100% sensitivity and a 62% specificity for finding a clinically significant complication on CESS. CONCLUSIONS: The study findings suggest that performing routine contrast-enhanced swallow studies on all patients is not necessary following POEM, as leaks can be screened for by clinical or laboratory abnormalities. Herein, we propose an algorithm based on objective measurable findings for the selection of patients who should undergo CESS.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Acalasia del Esófago , Humanos , Acalasia del Esófago/cirugía , Esfínter Esofágico Inferior/cirugía , Esofagoscopía , Cirugía Endoscópica por Orificios Naturales/métodos , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
13.
Sci Rep ; 12(1): 17132, 2022 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-36224357

RESUMEN

Penetrating abdominal injury is a major cause of death in trauma. Sodium alginate hydrogel, a hemostatic agent, offers a platform for targeting both mechanical and biological injuries. The current study assessed the effect of Very Low Viscosity (high) G (VLVG) alginate following abdominal trauma in a swine model of penetrating abdominal injury. Seven anesthetized pigs were instrumented with invasive monitoring catheters and abdominal trauma was introduced by laparoscopic hepatectomy. Ten minutes after the induction of hypovolemic shock, three animals were intra-abdominally administered with VLVG alginate (study group) and four animals with saline (control group). During 8 h of continuous monitoring, various hemodynamic and biochemical variables were measured and liver biopsies for histological evaluation were taken. Hemodynamically, VLVG alginate-treated animals were more stable than controls, as reflected by their lower heart rate and higher blood pressure (p < 0.05 for both). They also had lower levels of liver enzymes and lactate, and less histopathological damage. We show that VLVG alginate might be a promising new agent for reducing penetrating intra-abdominal injury, with hemostatic and biocompatibility efficiency, and tissue preserving properties. Future effort of integrating it with a dispersal device may turn it into a valuable pre-hospital emergency tool to improve survival of trauma casualties.


Asunto(s)
Traumatismos Abdominales , Hemostáticos , Heridas Penetrantes , Traumatismos Abdominales/tratamiento farmacológico , Traumatismos Abdominales/cirugía , Alginatos , Animales , Estudios de Factibilidad , Hemostáticos/farmacología , Hemostáticos/uso terapéutico , Hidrogeles , Lactatos , Porcinos , Heridas Penetrantes/tratamiento farmacológico
14.
Minim Invasive Ther Allied Technol ; 31(7): 1086-1095, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36148547

RESUMEN

INTRODUCTION: In non-resectable tumors, chemotherapy is crucial to improve patient survival. However, it is often accompanied by considerable side effects. Targeted delivery of chemotherapy by coupling with iron oxide superparamagnetic nanoparticles (IONP) could potentially increase efficacy while decreasing adverse systemic side effects. We aimed to evaluate the feasibility of targeting nontoxic, biodegradable-IONP into tumors in-vivo by applying an external magnetic field. MATERIAL AND METHODS: Subcutaneous colon carcinoma tumors were induced in 35 mice. IONP was injected systemically, followed by suturing of a magnet on top of the tumors for 2-24 h. Tumors and livers were excised and stained for iron to explore IONP localization. RESULTS: Iron staining was evident in 43% and 20% of tumors exposed to magnets for 4 h or 24 h, respectively. No iron was present following 2 h exposure, nor in the control group; however, iron stain in the livers indicates most of the IONP were cleared by the liver 24 h later. CONCLUSION: We demonstrated the targeting feasibility of IONP to tumor tissue by an external magnetic field. Our data shows successful targeting; however, with low efficacy following systemic injection of the IONP. As such, a paradigm shift is strongly recommended from systemic to locoregional IONP injection to increase targeting efficacy.


Asunto(s)
Nanopartículas de Magnetita , Neoplasias , Animales , Estudios de Factibilidad , Compuestos Férricos/uso terapéutico , Magnetismo , Ratones , Modelos Animales
15.
Work ; 71(3): 779-785, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35253672

RESUMEN

BACKGROUND: Minimally invasive surgery (MIS) has many advantages for patients, however, it places surgeons at risk for Work-related musculoskeletal disorders (WMSD). Recently, the importance of prevention of such injuries and improvement of the ergonomics of the operating room is increasing. OBJECTIVES: To assess the prevalence of WMSD among minimally invasive surgeons in Israel, discuss the contributing factors and the overall awareness for ergonomic training. In addition, a review of the literature on the topic was conducted. METHODS: An online questionnaire was sent to the members of the Israeli Society of Endoscopic Surgery. The results were analyzed and summarized. For literature review, PubMed was used to search for English-language publications related to the issue. RESULTS: Of 83 respondents, the majority (77%) have considerable experience in MIS (more than 10 years). The prevalence of WMSD was 12% before beginning the practice of laparoscopy compared to 78% after 15-20 years of practice. Injury sites included back pain, neck and upper extremity (shoulder pain, tennis elbow and carpal tunnel syndrome) in 41%, 25% and 34% respectively. More than two thirds of responders unaware of possible ergonomic solutions and didn't consider adopting any appropriate preventive measures. CONCLUSIONS: The incidence of WMSD among MIS surgeons is high and underestimated. There is a desperate need to prevent such morbidity among surgeons by increasing awareness and providing the means to improve their work environment. Surgeons should adhere to ergonomic recommendations for positioning of monitors, table height, posture, foot pedal placement and laparoscopic devices use.


Asunto(s)
Enfermedades Musculoesqueléticas , Enfermedades Profesionales , Cirujanos , Ergonomía/métodos , Humanos , Israel/epidemiología , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Enfermedades Musculoesqueléticas/epidemiología , Enfermedades Musculoesqueléticas/etiología , Enfermedades Musculoesqueléticas/prevención & control , Enfermedades Profesionales/epidemiología , Enfermedades Profesionales/etiología , Enfermedades Profesionales/prevención & control , Encuestas y Cuestionarios
16.
Minim Invasive Ther Allied Technol ; 31(4): 487-495, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33241969

RESUMEN

In the era of the novel coronavirus (COVID-19) pandemic, we critically appraised the literature by means of a systematic review on surgical education and propose an educational curriculum with the aid of available technologies. We performed a literature search on 10 May 2020 of Medline/PubMed, Embase, Google Scholar and major journals with specific COVID-19 sections. Articles eligible for inclusion contained the topic of education in surgery in the context of COVID-19. Specific questions we aimed to answer were: Is there any difference in surgical education from pre-COVID-19 to now? How does technology assist us in teaching? Can we better harness technology to augment resident training? Two-hundred and twenty-six articles were identified, 21 relevant for our aim: 14 case studies, three survey analyses, three reviews and one commentary. The collapse of the traditional educational system due to social distancing caused a fragmentation of knowledge, a reduced acquisition of skills and a decreased employment of surgical trainees. These problems can be partially overcome by using new technologies and arranging 2-weeks rotation shifts, alternating clinical activities with learning. While medical care will remain largely based on the interaction with patients, students' adaptability to innovation will be a characteristic of post-COVID classes.


Asunto(s)
COVID-19 , Curriculum , Humanos , Aprendizaje , Pandemias/prevención & control , SARS-CoV-2
17.
Surg Endosc ; 36(6): 4542-4551, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34731302

RESUMEN

BACKGROUND: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. METHODS: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. RESULTS: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. CONCLUSIONS: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.


Asunto(s)
Dióxido de Carbono , Laparoscopía , Falla de Equipo , Humanos , Laparoscopía/métodos , Instrumentos Quirúrgicos/efectos adversos
18.
Surg Endosc ; 36(5): 3340-3346, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34363113

RESUMEN

INTRODUCTION: The protection of intellectual property (IP) is one of the fundamental elements in the process of medical device development. The significance of IP, however, is not well understood among clinicians and researchers. The purpose of this study was to evaluate the current status of IP awareness and IP-related behaviors among EAES members. METHODS: A web-based survey was conducted via questionnaires sent to EAES members. Data collected included participant demographics, level of understanding the need, new ideas and solutions, basic IP knowledge, e.g., employees' inventions and public disclosure, behaviors before and after idea disclosures. RESULTS: One hundred and seventy-nine completed forms were obtained through an email campaign conducted twice in 2019 (response rate = 4.8%). There was a dominancy in male, formally-trained gastrointestinal surgeons, working at teaching hospitals in European countries. Of the respondents, 71% demonstrated a high level of understanding the needs (frustration with current medical devices), with 66% developing specific solutions by themselves. Active discussion with others was done by 53%. Twenty-one percent of respondents presented their ideas at medical congresses, and 12% published in scientific journals. Only 20% took specific precautions or appropriate actions to protect their IPs before these disclosures. CONCLUSIONS: The current level of awareness of IP and IP-related issues is relatively low among EAES members. A structured IP training program to gain basic IP knowledge and skill should be considered a necessity for clinicians. These skills would serve to prevent the loss of legitimate IP rights and avoid failure in the clinical implementation of innovative devices for the benefit of patients.


Asunto(s)
Propiedad Intelectual , Cirujanos , Europa (Continente) , Humanos , Masculino , Publicaciones , Encuestas y Cuestionarios
19.
Minim Invasive Ther Allied Technol ; 31(4): 567-572, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33459096

RESUMEN

OBJECTIVE: Easy and safe methods of fascia closure are needed in order to reduce the risk for trocar site hernias without affecting procedure time significantly. Here we present a method for port site closure using heat induced collagen denaturation. MATERIAL AND METHODS: Controlled heat-induced collagen denaturation was applied to laparoscopic trocar sites in living porcine animal models. These were compared to control trocar sites which were left open. Port sites were evaluated visually at days 14 and 28 after the procedure, and both visually and pathologically at post-procedural day 42. RESULTS: A total of 12 port sites were evaluated in three pigs. No incisional hernias were noted at any of the trocar sites in both groups. Histological evaluation revealed that one of the six control ports appeared to have a complete transfascial defect, whereas none of the study group trocars showed this finding. Furthermore, the study port sites showed a more robust scarring pattern. CONCLUSIONS: Heat-induced collagen denaturation in this preliminary study was found to be safe and allowed better scarring of the healing port sites. We believe that this technology may offer a safe and efficient closure of laparoscopic trocar sites. More studies are needed to further evaluate the true effectiveness of this technology.


Asunto(s)
Laparoscopía , Animales , Cicatriz , Hernia , Laparoscopios , Laparoscopía/efectos adversos , Laparoscopía/métodos , Instrumentos Quirúrgicos , Porcinos
20.
Minim Invasive Ther Allied Technol ; 31(4): 635-641, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33529074

RESUMEN

BACKGROUND: Complete or partial fundoplication remains controversial for the surgical treatment of GERD. While partial fundoplication is considered less effective, it is associated with less post-operative dysphagia and gas bloating compared with complete fundoplication. AIM: To compare the mechanical efficiency of the three different types of fundoplication. MATERIAL AND METHOD: Two studies of the LES were performed on explanted stomachs: distensibility and failure point. Measurements were taken before and after fundoplication. RESULTS: There was no difference in distensibility between Nissen and Toupet fundoplication, however, the EGJ was more distensible following Dor fundoplication. According to failure point measurements, Nissen fundoplication was significantly more effective than Toupet, Toupet was significantly more effective than Dor (p = .016, p = .017, respectively). CONCLUSIONS: There were significant differences in distensibility between Dor and both Nissen and Toupet, however no statistical difference between Toupet and Nissen. There was a significant difference in effectiveness between all three types of fundoplication according to the failure point. These laboratory findings demonstrate that the mechanical orientation of Nissen and Toupet have similar functionality suggesting that Toupet is as good as Nissen. While in clinical studies Toupet has fewer post-operative complications these findings support the proponents of Toupet for GERD. Abbreviation: GERD: Gastroesophageal reflux disease.


Asunto(s)
Fundoplicación , Reflujo Gastroesofágico , Fundoplicación/efectos adversos , Fundoplicación/métodos , Reflujo Gastroesofágico/cirugía , Humanos , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...