Am J Surg ; 228: 83-87, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37620215

RESUMEN

BACKGROUND: We evaluated the outcomes of a robotic pancreaticoduodenectomy (RPD) program implemented at a community tertiary care hospital. METHODS: A retrospective review of 65 RPD cases compared surgical outcomes and performance to benchmark data. RESULTS: Postoperative complications occurred in 31% (20) of patients vs. ≤73% (variance -42), with grade IV complications in 3% (2) vs. ≤5% (variance -2). Postoperative pancreatic fistula type B frequency was 12% (8) vs. ≤15% (variance -3). One 90-day mortality occurred (1.5% vs. 1.6%). Failure to rescue rate was 7% vs. ≤9% (variance -2), and R1 resection rate was 2% vs. ≤39% (variance -37). There was a downward trend of operative time (rho â€‹= â€‹-0.600, P â€‹< â€‹0.001), with a learning curve of 27 cases. Median hospital length of stay was 6 days vs. ≤15 days (variance -9). CONCLUSION: Our comprehensive RPD training program resulted in improved operative performance and outcomes commensurate with benchmark thresholds.


Asunto(s)
Laparoscopía , Neoplasias Pancreáticas , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Pancreaticoduodenectomía/métodos , Procedimientos Quirúrgicos Robotizados/educación , Centros de Atención Terciaria , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Curriculum , Neoplasias Pancreáticas/cirugía , Laparoscopía/métodos