Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 27(17): 24747-24764, 2019 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-31510359

RESUMEN

Large-scale optical switch networks employ wavelength division multiplexing to expand and facilitate multiple input and outputs. Such networks can be implemented with the Mach-Zehnder interferometer (MZI) as the building block. A fully-loaded MZI switch, meaning one with two optical signals at its two inputs and one that is capable of simultaneously switching those inputs to its two outputs, reduces the number building blocks within the network, and as a result makes them more power and area efficient. However, for practical operation, such MZI switches need to be automatically controlled for overcoming fabrication and thermal variations. We present an interference-based monitoring method that enables automatically switching, tuning, and stabilizing of a fully-loaded 2×2 MZI optical switch and demonstrate a prototype on an SOI platform. Using the proposed device and off-the-shelf electronics, we demonstrate automatic tuning and stabilization of an MZI switch with 12.5 Gb/s and 25 Gb/s data rates and channel spacing as small as 1 nm.

2.
Artículo en Inglés | MEDLINE | ID: mdl-22255669

RESUMEN

In this paper, we present a new seizure detection algorithm and the associated CMOS circuitry implementation. The proposed low-power seizure detector is a good candidate for an implantable epilepsy prosthesis. The device is designed for patient-specific seizure detection with a one variable parameter. The parameter value is extracted from a single seizure that is subsequently excluded from the validation phase. A two-path system is also proposed to minimize the detection delay. The algorithm is first validated using MATLAB® tools and then implemented and validated using circuits designed in a standard 0.18-µm CMOS process with a total power dissipation of 7.08 µW. A total of 13 seizures from two drug-resistant epileptic patients are assessed using the proposed algorithm and resulted in 100% sensitivity and a mean detection delay of 9.7 s after electrical onset.


Asunto(s)
Algoritmos , Diagnóstico por Computador/instrumentación , Electroencefalografía/instrumentación , Convulsiones/diagnóstico , Procesamiento de Señales Asistido por Computador/instrumentación , Transistores Electrónicos , Adulto , Suministros de Energía Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
3.
IEEE Trans Biomed Circuits Syst ; 5(1): 48-63, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23850978

RESUMEN

Resonance-based wireless power delivery is an efficient technique to transfer power over a relatively long distance. This technique typically uses four coils as opposed to two coils used in conventional inductive links. In the four-coil system, the adverse effects of a low coupling coefficient between primary and secondary coils are compensated by using high-quality (Q) factor coils, and the efficiency of the system is improved. Unlike its two-coil counterpart, the efficiency profile of the power transfer is not a monotonically decreasing function of the operating distance and is less sensitive to changes in the distance between the primary and secondary coils. A four-coil energy transfer system can be optimized to provide maximum efficiency at a given operating distance. We have analyzed the four-coil energy transfer systems and outlined the effect of design parameters on power-transfer efficiency. Design steps to obtain the efficient power-transfer system are presented and a design example is provided. A proof-of-concept prototype system is implemented and confirms the validity of the proposed analysis and design techniques. In the prototype system, for a power-link frequency of 700 kHz and a coil distance range of 10 to 20 mm, using a 22-mm diameter implantable coil resonance-based system shows a power-transfer efficiency of more than 80% with an enhanced operating range compared to ~40% efficiency achieved by a conventional two-coil system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA