Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
3.
Ann Surg Oncol ; 31(7): 4189-4196, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38652200

RESUMEN

BACKGROUND: Radio-guided surgery (RGS) holds promise for improving surgical outcomes in neuroendocrine tumors (NETs). Previous studies showed low specificity (SP) using γ-probes to detect radiation emitted by radio-labeled somatostatin analogs. OBJECTIVE: We aimed to assess the sensitivity (SE) and SP of the intraoperative RGS approach using a ß-probe with a per-lesion analysis, while assessing safety and feasibility as secondary objectives. METHODS: This prospective, single-arm, single-center, phase II trial (NCT05448157) enrolled 20 patients diagnosed with small intestine NETs (SI-NETs) with positive lesions detected at 68Ga-DOTA-TOC positron emission tomography/computed tomography (PET/CT). Patients received an intravenous injection of 1.1 MBq/Kg of 68Ga-DOTA-TOC 10 min prior to surgery. In vivo measurements were conducted using a ß-probe. Receiver operating characteristic (ROC) analysis was performed, with the tumor-to-background ratio (TBR) as the independent variable and pathology result (cancer vs. non-cancer) as the dependent variable. The area under the curve (AUC), optimal TBR, and absorbed dose for the surgery staff were reported. RESULTS: The intraoperative RGS approach was feasible in all cases without adverse effects. Of 134 specimens, the AUC was 0.928, with a TBR cut-off of 1.35 yielding 89.3% SE and 86.4% SP. The median absorbed dose for the surgery staff was 30 µSv (range 12-41 µSv). CONCLUSION: This study reports optimal accuracy in detecting lesions of SI-NETs using the intraoperative RGS approach with a novel ß-probe. The method was found to be safe, feasible, and easily reproducible in daily clinical practice, with minimal radiation exposure for the staff. RGS might potentially improve radical resection rates in SI-NETs. CLINICAL TRIALS REGISTRATION: 68Ga-DOTATOC Radio-Guided Surgery with ß-Probe in GEP-NET (RGS GEP-NET) [NCT0544815; https://classic. CLINICALTRIALS: gov/ct2/show/NCT05448157 ].


Asunto(s)
Neoplasias Intestinales , Intestino Delgado , Tumores Neuroendocrinos , Octreótido , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Cirugía Asistida por Computador , Humanos , Tumores Neuroendocrinos/cirugía , Tumores Neuroendocrinos/patología , Tumores Neuroendocrinos/diagnóstico por imagen , Femenino , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Neoplasias Intestinales/cirugía , Neoplasias Intestinales/patología , Neoplasias Intestinales/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Intestino Delgado/patología , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/cirugía , Octreótido/análogos & derivados , Adulto , Cirugía Asistida por Computador/métodos , Compuestos Organometálicos , Somatostatina/análogos & derivados , Estudios de Seguimiento , Pronóstico , Partículas beta/uso terapéutico , Estudios de Factibilidad
4.
Artículo en Inglés | MEDLINE | ID: mdl-38376805

RESUMEN

PURPOSE: In radioguided surgery (RGS), radiopharmaceuticals are used to generate preoperative roadmaps (e.g., PET/CT) and to facilitate intraoperative tracing of tracer avid lesions. Within RGS, there is a push toward the use of receptor-targeted radiopharmaceuticals, a trend that also has to align with the surgical move toward minimal invasive robotic surgery. Building on our initial ex vivo evaluation, this study investigates the clinical translation of a DROP-IN ß probe in robotic PSMA-guided prostate cancer surgery. METHODS: A clinical-grade DROP-IN ß probe was developed to support the detection of PET radioisotopes (e.g., 68 Ga). The prototype was evaluated in 7 primary prostate cancer patients, having at least 1 lymph node metastases visible on PSMA-PET. Patients were scheduled for radical prostatectomy combined with extended pelvic lymph node dissection. At the beginning of surgery, patients were injected with 1.1 MBq/kg of [68Ga]Ga-PSMA. The ß probe was used to trace PSMA-expressing lymph nodes in vivo. To support intraoperative decision-making, a statistical software algorithm was defined and optimized on this dataset to help the surgeon discriminate between probe signals coming from tumors and healthy tissue. RESULTS: The DROP-IN ß probe helped provide the surgeon with autonomous and highly maneuverable tracer detection. A total of 66 samples (i.e., lymph node specimens) were analyzed in vivo, of which 31 (47%) were found to be malignant. After optimization of the signal cutoff algorithm, we found a probe detection rate of 78% of the PSMA-PET-positive samples, a sensitivity of 76%, and a specificity of 93%, as compared to pathologic evaluation. CONCLUSION: This study shows the first-in-human use of a DROP-IN ß probe, supporting the integration of ß radio guidance and robotic surgery. The achieved competitive sensitivity and specificity help open the world of robotic RGS to a whole new range of radiopharmaceuticals.

5.
Phys Med ; 113: 102658, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37603908

RESUMEN

PURPOSE: Radioguided surgery (RGS) is a technique that helps the surgeon to achieve a tumour resection as complete as possible, by means of the intraoperative detection of particles emitted by a radiotracer that bounds to tumoural cells. This study aimed to investigate the applicability of ß-RGS for tumour resection and margin assessment in cervical cancer patients preoperatively injected with [18F]FDG, by means of Monte Carlo simulations. METHODS: Patients were retrospectively included if they had a recurrent or persistent cervical cancer, underwent preoperative PET/CT to exclude distant metastases and received radical surgery. All PET/CT images were analysed extracting tumour SUVmax, background SUVmean and tumour-to-non-tumour ratio. These values were used to obtain the expected count rate in a realistic surgical scenario by means of a Monte Carlo simulation of the ß probe, assuming the injection of 2 MBq/kg of [18F]FDG 60 min before surgery. RESULTS: Thirty-eight patients were included. A measuring time of ∼2-3 s is expected to be sufficient for discriminating the tumour from background in a given lesion, being this the time the probe has to be over the sample in order to be able to discriminate tumour from healthy tissue with a sensitivity of ∼99% and a specificity of at least 95%. CONCLUSION: This study presents the first step towards a possible application of our ß-RGS technique in cervical cancer. Results suggest that this approach to ß-RGS could help surgeons distinguish tumour margins from surrounding healthy tissue, even in a setting of high radiotracer background activity.


Asunto(s)
Cirugía Asistida por Computador , Neoplasias del Cuello Uterino , Humanos , Femenino , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/cirugía , Estudios de Factibilidad , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos
6.
Med Phys ; 49(1): 23-40, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34813083

RESUMEN

PURPOSE: In-beam positron emission tomography (PET) is one of the modalities that can be used for in vivo noninvasive treatment monitoring in proton therapy. Although PET monitoring has been frequently applied for this purpose, there is still no straightforward method to translate the information obtained from the PET images into easy-to-interpret information for clinical personnel. The purpose of this work is to propose a statistical method for analyzing in-beam PET monitoring images that can be used to locate, quantify, and visualize regions with possible morphological changes occurring over the course of treatment. METHODS: We selected a patient treated for squamous cell carcinoma (SCC) with proton therapy, to perform multiple Monte Carlo (MC) simulations of the expected PET signal at the start of treatment, and to study how the PET signal may change along the treatment course due to morphological changes. We performed voxel-wise two-tailed statistical tests of the simulated PET images, resembling the voxel-based morphometry (VBM) method commonly used in neuroimaging data analysis, to locate regions with significant morphological changes and to quantify the change. RESULTS: The VBM resembling method has been successfully applied to the simulated in-beam PET images, despite the fact that such images suffer from image artifacts and limited statistics. Three dimensional probability maps were obtained, that allowed to identify interfractional morphological changes and to visualize them superimposed on the computed tomography (CT) scan. In particular, the characteristic color patterns resulting from the two-tailed statistical tests lend themselves to trigger alarms in case of morphological changes along the course of treatment. CONCLUSIONS: The statistical method presented in this work is a promising method to apply to PET monitoring data to reveal interfractional morphological changes in patients, occurring over the course of treatment. Based on simulated in-beam PET treatment monitoring images, we showed that with our method it was possible to correctly identify the regions that changed. Moreover we could quantify the changes, and visualize them superimposed on the CT scan. The proposed method can possibly help clinical personnel in the replanning procedure in adaptive proton therapy treatments.


Asunto(s)
Terapia de Protones , Humanos , Método de Montecarlo , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X
7.
Med Phys ; 48(12): 8117-8126, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34704618

RESUMEN

PURPOSE: A high level of personalization in Molecular Radiotherapy (MRT) could bring advantages in terms of treatment effectiveness and toxicity reduction. Individual organ-level dosimetry is crucial to describe the radiopharmaceutical biodistribution expressed by the patient, to estimate absorbed doses to normal organs and target tissue(s). This paper presents a proof-of-concept Monte Carlo simulation study of "WIDMApp" (Wearable Individual Dose Monitoring Apparatus), a multi-channel radiation detector and data processing system for in vivo patient measurement and collection of radiopharmaceutical biokinetic data (i.e., time-activity data). Potentially, such a system can increase the amount of such data that can be collected while reducing the need to derive it via nuclear medicine imaging. METHODS: a male anthropomorphic MIRD phantom was used to simulate photons (i.e., gamma-rays) propagation in a patient undergoing a 131 I thyroid treatment. The administered activity was set to the amount usually administered for the treatment of differentiated carcinoma while its initial distribution in different organs was assigned following the ICRP indications for the 131 I biokinetics. Using this information, the simulation computes the Time-dependent Counts Curves (TCCs) that would have been measured by seven WIDMApp-like sensors placed and oriented to face each one of five emitting organs plus two thyroid lobes. A deconvolution algorithm was then applied on this simulated data set to reconstruct the Time-Activity Curve (TAC) of each organ. Deviations of the reconstructed TACs parameters from values used to generate them were studied as a function of the deconvolution algorithm initialization parameters and assuming non-Poisson fluctuation of the TCCs data points. RESULTS: This study demonstrates that it is possible, at least in the simple simulated scenario, to reconstruct the organ cumulated activity by measuring the time dependence of counts recorded by several detectors placed at selected positions on the patient's body. The ability to perform in vivo sampling more frequently than conventional biokinetic studies increases the number of time points and therefore the accuracy in TAC estimates. In this study, an accuracy on cumulated activity of 5% is obtained even with a 20% error on the TCC data points and a 50% error on the initial guess on the parameters of the deconvolution algorithm. CONCLUSIONS: the WIDMApp approach could provide an effective tool to characterize more accurately the radiopharmaceutical biokinetics in MRT patients, reducing the need of resources of nuclear medicine departments, such as technologist and scanner time, to perform individualized biokinetics studies. The relatively simple hardware for the approach proposed would allow its application to large numbers of patients. The results obtained justify development of an actual prototype system to characterize this technique under realistic conditions.


Asunto(s)
Radiofármacos , Dispositivos Electrónicos Vestibles , Humanos , Masculino , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría , Distribución Tisular
8.
Front Oncol ; 11: 601784, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34178614

RESUMEN

Particle therapy in which deep seated tumours are treated using 12C ions (Carbon Ions RadioTherapy or CIRT) exploits the high conformity in the dose release, the high relative biological effectiveness and low oxygen enhancement ratio of such projectiles. The advantages of CIRT are driving a rapid increase in the number of centres that are trying to implement such technique. To fully profit from the ballistic precision achievable in delivering the dose to the target volume an online range verification system would be needed, but currently missing. The 12C ions beams range could only be monitored by looking at the secondary radiation emitted by the primary beam interaction with the patient tissues and no technical solution capable of the needed precision has been adopted in the clinical centres yet. The detection of charged secondary fragments, mainly protons, emitted by the patient is a promising approach, and is currently being explored in clinical trials at CNAO. Charged particles are easy to detect and can be back-tracked to the emission point with high efficiency in an almost background-free environment. These fragments are the product of projectiles fragmentation, and are hence mainly produced along the beam path inside the patient. This experimental signature can be used to monitor the beam position in the plane orthogonal to its flight direction, providing an online feedback to the beam transverse position monitor chambers used in the clinical centres. This information could be used to cross-check, validate and calibrate, whenever needed, the information provided by the ion chambers already implemented in most clinical centres as beam control detectors. In this paper we study the feasibility of such strategy in the clinical routine, analysing the data collected during the clinical trial performed at the CNAO facility on patients treated using 12C ions and monitored using the Dose Profiler (DP) detector developed within the INSIDE project. On the basis of the data collected monitoring three patients, the technique potential and limitations will be discussed.

9.
Cancer Biother Radiopharm ; 36(5): 397-406, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33601932

RESUMEN

Background: In neuroendocrine tumor (NET), complete surgery could better the prognosis. Radioguided surgery (RGS) with ß--radioisotopes is a novel approach focused on developing a new probe that, detecting electrons and operating with low background, provides a clearer delineation of the lesions with low radiation exposition for surgeons. As a first step to validate this procedure, ex vivo specimens of tumors expressing somatostatin receptors, as small intestine neuroendocrine tumor (SI-NET), were tested. Materials and Methods: SI-NET presents a high uptake of a beta-emitting radiotracer, 90Y-DOTATOC. Five SI-NET patients were enrolled after performing a 68Ga-DOTATOC positron emission tomography/computed tomography (CT) and a CT enterography; 24 h before surgery, they received 5 mCi of 90Y-DOTATOC. Results: Surgery was performed as routine. Tumors and surrounding tissue were sectioned in different samples and examined ex vivo with the beta-detecting probe. All the tumor samples showed high counts of radioactivity that was up to a factor of 18 times higher than the corresponding cutoff value, with a sensitivity of 96% and a specificity of 100%. Conclusions: These first ex vivo RGS tests showed that this probe can discriminate very effectively between tumor and healthy tissues by the administration of low activities of 90Y-DOTATOC, allowing more precise surgery.


Asunto(s)
Neoplasias Intestinales/cirugía , Tumores Neuroendocrinos/cirugía , Octreótido/análogos & derivados , Anciano , Partículas beta , Femenino , Humanos , Neoplasias Intestinales/diagnóstico por imagen , Neoplasias Intestinales/patología , Intestino Delgado , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Compuestos Organometálicos , Proyectos Piloto , Tomografía Computarizada por Tomografía de Emisión de Positrones , Receptores de Somatostatina , Sensibilidad y Especificidad , Radioisótopos de Itrio
10.
Front Oncol ; 11: 777852, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35024354

RESUMEN

Different therapies are adopted for the treatment of deep seated tumours in combination or as an alternative to surgical removal or chemotherapy: radiotherapy with photons (RT), particle therapy (PT) with protons or even heavier ions like 12C, are now available in clinical centres. In addition to these irradiation modalities, the use of Very High Energy Electron (VHEE) beams (100-200 MeV) has been suggested in the past, but the diffusion of that technique was delayed due to the needed space and budget, with respect to standard photon devices. These disadvantages were not paired by an increased therapeutic efficacy, at least when comparing to proton or carbon ion beams. In this contribution we investigate how recent developments in electron beam therapy could reshape the treatments of deep seated tumours. In this respect we carefully explored the application of VHEE beams to the prostate cancer, a well-known and studied example of deep seated tumour currently treated with high efficacy both using RT and PT. The VHEE Treatment Planning System was obtained by means of an accurate Monte Carlo (MC) simulation of the electrons interactions with the patient body. A simple model of the FLASH effect (healthy tissues sparing at ultra-high dose rates), has been introduced and the results have been compared with conventional RT. The study demonstrates that VHEE beams, even in absence of a significant FLASH effect and with a reduced energy range (70-130 MeV) with respect to implementations already explored in literature, could be a good alternative to standard RT, even in the framework of technological developments that are nowadays affordable.

11.
EJNMMI Res ; 10(1): 92, 2020 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32761408

RESUMEN

BACKGROUND: Recently, a flexible DROP-IN gamma-probe was introduced for robot-assisted radioguided surgery, using traditional low-energy SPECT-isotopes. In parallel, a novel approach to achieve sensitive radioguidance using beta-emitting PET isotopes has been proposed. Integration of these two concepts would allow to exploit the use of PET tracers during robot-assisted tumor-receptor-targeted. In this study, we have engineered and validated the performance of a novel DROP-IN beta particle (DROP-INß) detector. METHODS: Seven prostate cancer patients with PSMA-PET positive tumors received an additional intraoperative injection of ~ 70 MBq 68Ga-PSMA-11, followed by robot-assisted prostatectomy and extended pelvic lymph node dissection. The surgical specimens from these procedures were used to validate the performance of our DROP-INß probe prototype, which merged a scintillating detector with a housing optimized for a 12-mm trocar and prograsp instruments. RESULTS: After optimization of the detector and probe housing via Monte Carlo simulations, the resulting DROP-INß probe prototype was tested in a robotic setting. In the ex vivo setting, the probe-positioned by the robot-was able to identify 68Ga-PSMA-11 containing hot-spots in the surgical specimens: signal-to-background (S/B) was > 5 when pathology confirmed that the tumor was located < 1 mm below the specimen surface. 68Ga-PSMA-11 containing (and PET positive) lymph nodes, as found in two patients, were also confirmed with the DROP-INß probe (S/B > 3). The rotational freedom of the DROP-IN design and the ability to manipulate the probe with the prograsp tool allowed the surgeon to perform autonomous beta-tracing. CONCLUSIONS: This study demonstrates the feasibility of beta-radioguided surgery in a robotic context by means of a DROP-INß detector. When translated to an in vivo setting in the future, this technique could provide a valuable tool in detecting tumor remnants on the prostate surface and in confirmation of PSMA-PET positive lymph nodes.

12.
Sci Rep ; 10(1): 4015, 2020 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-32132632

RESUMEN

The possibility to use ß- decaying isotopes for radioguided surgery (RGS) has been recently proposed, and first promising tests on ex-vivo samples of Meningioma and intestinal Neuroendocrine Tumor (NET) have been published. This paper reports a study of the uptake of 68Ga-DOTATOC in pancreatic NETs (pNETs) in order to assess the feasibility of a new RGS approach using 90Y-DOTATOC. Tumor and healthy pancreas uptakes were estimated from 68Ga-DOTATOC PET/CT scans of 30 patients with pNETs. From the obtained SUVs (Standardised Uptake Value) and TNRs (Tumor Non tumor Ratio), an analysis algorithm relying on a Monte Carlo simulation of the detector has been applied to evaluate the performances of the proposed technique. Almost all considered patients resulted to be compatible with the application of ß--RGS assuming to administer 1.5 MBq/kg of activity of 90Y-DOTATOC 24 h before surgery, and a sampling time of few seconds. In just 2 cases the technique would have required a mildly increased amount of activity or of sampling time. Despite a high physiological uptake of 68Ga-DOTATOC in the healthy pancreas, the proposed RGS technique promises to be effective. This approach allows RGS to find application also in pancreatic diseases, where traditional techniques are not viable.


Asunto(s)
Algoritmos , Neoplasias Intestinales , Tumores Neuroendocrinos , Neoplasias Pancreáticas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias Gástricas , Cirugía Asistida por Computador , Anciano , Partículas beta , Femenino , Humanos , Neoplasias Intestinales/diagnóstico por imagen , Neoplasias Intestinales/terapia , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/terapia , Octreótido/administración & dosificación , Octreótido/análogos & derivados , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/terapia , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/terapia
13.
Sci Rep ; 8(1): 16171, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30385885

RESUMEN

Radio Guided Surgery is a technique helping the surgeon in the resection of tumors: a radiolabeled tracer is administered to the patient before surgery and then the surgeon evaluates the completeness of the resection with a handheld detector sensitive to emitted radiation. Established methods rely on γ emitting tracers coupled with γ detecting probes. The efficacy of this technique is however hindered by the high penetration of γ radiation, limiting its applicability to low background conditions. To overtake such limitations, a novel approach to RGS has been proposed, relying on ß- emitting isotopes together with a dedicated ß probe. This technique has been proved to be effective in first ex-vivo trials. We discuss in this paper the possibility to extend its application cases to 68Ga, a ß+ emitting isotope widely used today in nuclear medicine. To this aim, a retrospective study on 45 prostatic cancer patients was performed, analysing their 68Ga-PSMA PET images to asses if the molecule uptake is enough to apply this technique. Despite the expected variability both in terms of SUV (median 4.1, IQR 3.0-6.1) and TNR (median 9.4, IQR 5.2-14.6), the majority of cases have been found to be compatible with ß-RGS with reasonable injected activity and probing time (5 s).


Asunto(s)
Partículas beta/uso terapéutico , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Cirugía Asistida por Computador , Ácido Edético/administración & dosificación , Ácido Edético/análogos & derivados , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Oligopéptidos/administración & dosificación , Tomografía de Emisión de Positrones , Neoplasias de la Próstata/patología , Radiofármacos/administración & dosificación
14.
Phys Med ; 43: 127-133, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29195555

RESUMEN

PURPOSE: Beta-particle radioguided tumor resection may potentially overcome the limitations of conventional gamma-ray guided surgery by eliminating, or at least minimizing, the confounding effect of counts contributed by activity in adjacent normal tissues. The current study evaluates the clinical feasibility of this approach for a variety of radionuclides. Nowadays, the only ß- radioisotope suited to radioguided surgery is 90Y. Here, we study the ß- probe prototype capability to different radionuclides chosen among those used in nuclear medicine. METHODS: The counting efficiency of our probe prototype was evaluated for sources of electrons and photons of different energies. Such measurements were used to benchmark the Monte Carlo (MC) simulation of the probe behavior, especially the parameters related to the simulation of the optical photon propagation in the scintillation crystal. Then, the MC simulation was used to derive the signal and the background we would measure from a small tumor embedded in the patient body if one of the selected radionuclides is used. RESULTS: Based on the criterion of detectability of a 0.1 ml tumor for a counting interval of 1 s and an administered activity of 3 MBq/kg, the current probe yields a detectable signal over a wide range of Standard Uptake Values (SUVs) and tumor-to-non-tumor activity-concentration ratios (TNRs) for 31Si, 32P, 97Zr, and 188Re. Although efficient counting of 83Br, 133I, and 153Sm proved somewhat more problematic, the foregoing criterion can be satisfied for these isotopes as well for sufficiently high SUVs and TNRs.


Asunto(s)
Partículas beta , Cirugía General/métodos , Estudios de Factibilidad , Neoplasias/cirugía , Medicina Nuclear , Radioisótopos , Radiometría
15.
Phys Med Biol ; 2017 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-28885189

RESUMEN

In this paper we report the re-analysis of the data published in (Piersanti et al. 2014) documenting the charged secondary particles production induced by the interaction of a 220 MeV/u 12C ion beam impinging on a polymethyl methacrylate (PMMA) target, measured in 2012 at the GSI facility in Darmstadt (Germany). This re-analysis takes into account the inhomogeneous light response of the LYSO crystal in the experimental setup measured in a subsequent experiment (2014) performed in the Heidelberg Ion- Beam Therapy Center. A better description of the detector and re-calculation of the geometrical efficiencies have been implemented as well, based on an improved approach that accounts also for the energy dependence of the emission spectrum. The new analysis has small effect on the total secondary charged flux, but has an impact on the production yield and emission velocity distributions of the different particle species (protons, deuterons and tritons) at different angles with respect to the beam direction (60° and 90°). All these observables indeed depend on the particle identification algorithms and hence on the LYSO detector energy response. The results of the data re-analysis presented here are intended to supersede and replace the results published in (Piersanti et al. 2014).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...