Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Rev Sci Instrum ; 92(6): 063301, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243550

RESUMEN

A dosimetric calibration of three types of radiochromic films (GafChromicTM HD-V2, MD-V3, and EBT3) was carried out for absorbed doses (D) ranging up to 100 kGy using a 130 TBq Co60 γ-ray source. The optical densities (ODs) of the irradiated films were acquired with the transmission-mode flatbed film scanner EPSON GT-X980. The calibration data were cross-checked using the 20-MeV proton beam from the azimuthally varying field cyclotron at the Research Center for Nuclear Physics in Osaka University. These experimental results not only present the measurable dose ranges of the films depending on the readout wavelength, but also show consistency with our hypothesis that the OD response curve [log(OD)-log(D) curve] is determined by the volumetric average of the absorption dose and does not strongly depend on the type of radiation for the excitation.

3.
Sci Rep ; 10(1): 20157, 2020 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-33214592

RESUMEN

The scientific and technical advances continue to support novel discoveries by allowing scientists to acquire new insights into the structure and properties of matter using new tools and sources. Notably, neutrons are among the most valuable sources in providing such a capability. At the Institute of Laser Engineering, Osaka, the first steps are taken towards the development of a table-top laser-driven neutron source, capable of producing a wide range of energies with high brightness and temporal resolution. By employing a pure hydrogen moderator, maintained at cryogenic temperature, a cold neutron ([Formula: see text]) flux of [Formula: see text]/pulse was measured at the proximity of the moderator exit surface. The beam duration of hundreds of ns to tens of [Formula: see text] is evaluated for neutron energies ranging from 100s keV down to meV via Monte-Carlo techniques. Presently, with the upcoming J-EPoCH high repetition rate laser at Osaka University, a cold neutron flux in orders of [Formula: see text] is expected to be delivered at the moderator in a compact beamline.

4.
Rev Sci Instrum ; 89(10): 10I114, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399813

RESUMEN

A design of multichannel gated photomultiplier tube (PMT) is presented for the 960-channel neutron time-of-flight detector at the Institute of Laser Engineering of Osaka University. This is important for the fusion science and the nuclear photonics where intense hard X-rays are generated from the interaction of ultra-short laser pulse of petawatt power density with matter. The hard X-rays often overload PMTs and cause signal-induced background noises called afterpulses, making the detection of subsequent neutrons impossible. For this reason, the PMTs are coupled with an electrical time-gating (ETG) system to avoid overloading. The ETG system disables the PMT by modulating the dynode potential during the primary X-ray flash. An after-pulsing suppression technique is demonstrated by applying a reverse bias voltage between the photocathode and the first dynode. The presented multichannel scheme provides a gate response time of 80 ns, a signal cutoff ratio of 2.5 × 102, and requires reasonably low power consumption.

5.
Phys Rev Lett ; 120(20): 204801, 2018 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-29864368

RESUMEN

A dual ion species plasma expansion scheme from a novel target structure is introduced, in which a nanometer-thick layer of pure deuterium exists as a buffer species at the target-vacuum interface of a hydrogen plasma. Modeling shows that by controlling the deuterium layer thickness, a composite H^{+}/D^{+} ion beam can be produced by target normal sheath acceleration (TNSA), with an adjustable ratio of ion densities, as high energy proton acceleration is suppressed by the acceleration of a spectrally peaked deuteron beam. Particle in cell modeling shows that a (4.3±0.7) MeV per nucleon deuteron beam is accelerated, in a directional cone of half angle 9°. Experimentally, this was investigated using state of the art cryogenic targetry and a spectrally peaked deuteron beam of (3.4±0.7) MeV per nucleon was measured in a cone of half angle 7°-9°, while maintaining a significant TNSA proton component.

6.
Nat Commun ; 9(1): 724, 2018 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-29463872

RESUMEN

The range of potential applications of compact laser-plasma ion sources motivates the development of new acceleration schemes to increase achievable ion energies and conversion efficiencies. Whilst the evolving nature of laser-plasma interactions can limit the effectiveness of individual acceleration mechanisms, it can also enable the development of hybrid schemes, allowing additional degrees of control on the properties of the resulting ion beam. Here we report on an experimental demonstration of efficient proton acceleration to energies exceeding 94 MeV via a hybrid scheme of radiation pressure-sheath acceleration in an ultrathin foil irradiated by a linearly polarised laser pulse. This occurs via a double-peaked electrostatic field structure, which, at an optimum foil thickness, is significantly enhanced by relativistic transparency and an associated jet of super-thermal electrons. The range of parameters over which this hybrid scenario occurs is discussed and implications for ion acceleration driven by next-generation, multi-petawatt laser facilities are explored.

7.
Rev Sci Instrum ; 86(7): 073308, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26233373

RESUMEN

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.


Asunto(s)
Calibración , Rayos Láser , Neutrones , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...