Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
ACS Appl Bio Mater ; 7(5): 2966-2981, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38652577

RESUMEN

This study presents a facile fabrication of 58S bioactive glass (BG)-polymer composite coatings on a 316L stainless steel (SS) substrate using the electrophoretic deposition technique. The suspension characteristics and deposition kinetics of BG, along with three different polymers, namely ethylcellulose (EC), poly(acrylic acid) (PAA), and polyvinylpyrrolidone (PVP), have been utilized to fabricate the coatings. Among all coatings, 58S BG and EC polymers are selected as the final composite coating (EC6) owing to their homogeneity and good adhesion. EC6 coating exhibits a thickness of ∼18 µm and an average roughness of ∼2.5 µm. Herein, EC6 demonstrates better hydroxyapatite formation compared to PAA and PVP coatings in simulated body fluid-based mineralization studies for a period of 28 days. Corrosion studies of EC6 in phosphate-buffered saline further confirm the higher corrosion resistance properties after 14 days. In vitro cytocompatibility studies using human placental mesenchymal stem cells demonstrate an increase in cellular viability, attachment, and higher proliferation compared to the bare SS substrate. EC6 coatings promote osteogenic differentiation, which is confirmed via the upregulation of the OPN and OCN genes. Moreover, the EC6 sample exhibits improved antibacterial properties against Escherichia coli and Staphylococcus aureus compared to the uncoated ones. The findings of this work emphasize the potential of electrophoretically fabricated BG-EC composite coatings on SS substrates for orthopedic applications.


Asunto(s)
Materiales Biocompatibles Revestidos , Vidrio , Ensayo de Materiales , Polímeros , Acero Inoxidable , Acero Inoxidable/química , Humanos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Vidrio/química , Polímeros/química , Polímeros/farmacología , Corrosión , Tamaño de la Partícula , Propiedades de Superficie , Antibacterianos/farmacología , Antibacterianos/química , Escherichia coli/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Electroforesis , Supervivencia Celular/efectos de los fármacos , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/citología , Pruebas de Sensibilidad Microbiana , Proliferación Celular/efectos de los fármacos
2.
Small ; 20(5): e2305300, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37735143

RESUMEN

Caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), coronavirus disease 2019 (COVID-19) has shown extensive lung manifestations in vulnerable individuals, putting lung imaging and monitoring at the forefront of early detection and treatment. Magnetic particle imaging (MPI) is an imaging modality, which can bring excellent contrast, sensitivity, and signal-to-noise ratios to lung imaging for the development of new theranostic approaches for respiratory diseases. Advances in MPI tracers would offer additional improvements and increase the potential for clinical translation of MPI. Here, a high-performance nanotracer based on shape anisotropy of magnetic nanoparticles is developed and its use in MPI imaging of the lung is demonstrated. Shape anisotropy proves to be a critical parameter for increasing signal intensity and resolution and exceeding those properties of conventional spherical nanoparticles. The 0D nanoparticles exhibit a 2-fold increase, while the 1D nanorods have a > 5-fold increase in signal intensity when compared to VivoTrax. Newly designed 1D nanorods displayed high signal intensities and excellent resolution in lung images. A spatiotemporal lung imaging study in mice revealed that this tracer offers new opportunities for monitoring disease and guiding intervention.


Asunto(s)
Nanopartículas de Magnetita , Nanopartículas , Ratones , Animales , Anisotropía , Diagnóstico por Imagen/métodos , Magnetismo , Fenómenos Magnéticos , Imagen por Resonancia Magnética
3.
Small ; : e2307350, 2023 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-38072806

RESUMEN

Hydrogen (H2 ), the most abundant element in the universe, has the potential to address the challenges of energy security and climate change. However, due to the lack of a safe and efficient method for storing and delivering hydrogen, its practical application is still in its infancy stages. To overcome this challenge, a promising solution is demonstrated in the form of on-demand production of H2 using nano-Silicon (Si) powders. The method offers instantaneous production of H2 , yielding a volume of 1.3 L per gram of Si at room temperature. Moreover, the H2 production yield and the rate can be effectively controlled by adjusting the reaction pH value and temperatures. Additionally, liquid-phase transmission electron microscopy (LPTEM) is utilized in situ to demonstrate the entire reaction in real-time, wherein H2 bubble formation is observed and illustrated the gradual conversion of crystalline Si particles into amorphous oxides. Moreover, it is confirmed that the purity of the generated gas is 99.5% using gas chromatography mass spectrometry (GC-MS). These findings suggest a viable option for instant H2 production in portable fuel cells using Si cartridges or pellets.

4.
Int J Retina Vitreous ; 9(1): 30, 2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37120629

RESUMEN

PURPOSE: To measure the proportion of unexplained and all causes of visual loss following primary rhegmatogenous-retinal-detachment (RRD) repair, comparing gas tamponade (SF6, C2F6, C3F8), silicone oil (SO, 1000cs and 5000cs) and heavy silicone oil (Densiron). METHODS: Retrospective, continuous, comparative study from 01/1/2017-31/5/2021. All primary RRDs were included after successful removal of SO and Densiron. Primary failures were excluded. Visual loss was defined as reduction of ≥0.30 logMAR units. Multivariable binary-logistic and linear regression models to compare tamponade, and all cases of unexplained visual loss and logMAR gain were performed. Covariates included age, ocular co-morbidities, pre-op vision, macula-status, high-myopia, giant-retinal-tear (GRT), perfluorocarbon-use, combined buckle/PPV, PVR-C, retinectomy, tamponade agent and post-operative lens status. RESULTS: Of 1,012 primary RRDs, we found an incidence of unexplained visual loss in 15/1012 (1.5%, SF6:1/341[0.3%], C2F6:4/338[1.2%], C3F8:2/239[0.8%], Densiron:0/33[0.0%], SO-1000cs:5/43[11.6%] and SO-5000cs:3/18[16.7%]), and visual loss of all causes in 57/1012 (5.6%, SF6:13/341[3.8%], C2F6:14/338[4.1%], C3F8:15/239[6.3%], Densiron:2/33[6.1%], SO-1000cs:9/43[20.9%] and SO-5000cs:4/18[22.2%]). On multivariable binary-logistic regression, we report that macula-on RRD (Odds-Ratio[OR]5.7,95% Confidence-interval[CI]1.2-28.2, p=0.032), GRT (OR35.0,CI 2.0-617.3, p=0.015), combined buckle/PPV (OR37.7,CI 2.0-711.4, p=0.015), SO1000cs (OR86.6,CI 5.6-1,348.0), p=0.001) and 5000cs (OR37.2,CI 1.3-1,101.5, p=0.036) (Reference-tamponade:SF6) were associated with unexplained visual loss. Duration of oil tamponade was not linked to increase in unexplained visual loss (p=0.569). CONCLUSIONS: Correlation between SO in detachment repairs and unexplained visual loss has been established, however incidence with HSO has not been compared to other agents. This study demonstrates that although SO was linked with risk-adjusted increased unexplained visual loss relative to gas tamponade, no such association was found for Densiron, on multivariable analysis.

5.
Retin Cases Brief Rep ; 17(2): 152-153, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33534394

RESUMEN

PURPOSE: To report a new ?rescue" technique for the removal of a dropped heavy silicone oil (HSO) bubble, after failed aspiration with a short, 23-gauge cannula and suction pump. METHODS: If the HSO bubble is dropped during standard, 23-gauge, transconjunctival extraction with a suction pump, filtered air can be injected into the HSO bubble to make it rise. Extraction can then be resumed with the suction pump, resulting in complete removal of HSO. RESULTS: This technique has been used approximately ten times over the last 18 months with a 100% success rate and no complications. CONCLUSION: We present a safe, simple, and cost-effective ?rescue" method for the removal of a dropped HSO bubble using air. With the rise in popularity of HSO and the development of new heavy tamponades, safe and effective techniques for their removal are becoming increasingly important.


Asunto(s)
Desprendimiento de Retina , Humanos , Desprendimiento de Retina/cirugía , Vitrectomía/métodos , Aceites de Silicona
6.
Spektrum Augenheilkd ; 37(1): 1-8, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35645464

RESUMEN

Purpose: To review the sustained effect of COVID-19 on rhegmatogenous retinal detachment (RRD) baseline characteristics and outcomes. Methods: This was a retrospective consecutive case series at the Birmingham and Midlands Eye Centre including patients undergoing primary RRD repair between 23 March and 31 December 2017-2019 (Group 1) and 2020 (Group 2). The deciles of indices of multiple deprivation (IMD) were determined by postcode to group patients into least deprived (IMD1-5) and most deprived (IMD6-10). Results: In total we reviewed 1310 patients, 1003 in Group 1 and 307 in Group 2. Relative to 2017-2019, during the first lockdown, we observed (a) a reduction in the number of patients with RRD, (b) an increase in macula-off detachments, (c) an increase in RRD primary failure, and (d) that the least deprived had proportionately higher primary failure than the most deprived (p = 0.049) with a higher detachment rate than the pre-COVID-19 period (p = 0.010) and increased presentations of macula-off detachment. During the second lockdown, these differences were not observed. Conclusion: The previously observed findings of lower presentation rates of RRD during the beginning of the first lockdown and the decreased number of macula-on RRD were not sustained over a longer period of observation or found to recur after a second national lockdown. Patients from areas with the least socioeconomic deprivation seemed to be more negatively affected by the first lockdown, with later presentation and higher rates of re-detachments compared with the most deprived during the first lockdown. Our findings offer reassurance that patient behaviour and health services had adapted to the pandemic by the second national lockdown. Supplementary Information: The online version of this article (10.1007/s00717-022-00521-0) contains supplementary material, which is available to authorized users.

7.
Eye (Lond) ; 37(11): 2310-2315, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36513858

RESUMEN

BACKGROUND/AIM: To report 5-year real-world efficacy and safety data following the treatment of chronic diabetic macular oedema (DMO) with the intravitreal 0.19 mg fluocinolone acetonide implant(ILUVIEN). METHODS: Retrospective cohort study of 31 eyes treated with ILUVIEN for chronic DMO at a tertiary centre in Birmingham (UK). Best corrected visual acuity (BCVA) and central retinal thickness (CRT) were recorded at baseline, and then at 1-,2-,3-, and 5-years. Safety was assessed based on intraocular pressure (IOP) -lowering medication, surgery, and other complications. RESULTS: BCVA significantly improved 1-year post-ILUVIEN (+4.2 letters, p < 0.05) and gradually reverted to baseline levels over the 5-year period of follow-up (+0.2 letters at year-5). A significant and sustained CRT reduction was observed throughout the 5-years. The proportion of eyes on IOP-lowering medication increased from 16% at baseline, to 70% at 5-years (p < 0.001) with eyes on a mean of 1.3 medications. Laser trabeculoplasty (n = 2), cyclodiode laser (n = 1), and trabeculoplasty and trabeculotomy (n = 1, in the same eye; 3.2%) were required for uncontrolled IOP. Other complications included endophthalmitis (n = 1) and vitreous haemorrhage (n = 1). 58% of eyes required additional intravitreal injections, with a mean 29.2 months to first injection. We observed a 69% reduction in treatment burden following treatment with ILUVIEN implant. CONCLUSIONS: Our real-world results confirm the efficacy of the ILUVIEN implant over 5 years, with two-thirds of eyes having improved or stable visual acuity 5 years after ILUVIEN, and an overall sustained improvement in anatomical outcome. Although the rate of IOP-lowering medications use was higher than previously reported, the rate of incisional IOP-lowering surgery and other complications remained low and in keeping with rates reported in larger studies.


Asunto(s)
Diabetes Mellitus , Retinopatía Diabética , Edema Macular , Humanos , Fluocinolona Acetonida , Glucocorticoides/uso terapéutico , Edema Macular/tratamiento farmacológico , Edema Macular/etiología , Retinopatía Diabética/complicaciones , Retinopatía Diabética/tratamiento farmacológico , Estudios Retrospectivos , Resultado del Tratamiento , Inyecciones Intravítreas , Implantes de Medicamentos/uso terapéutico
8.
Diagnostics (Basel) ; 12(12)2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36553051

RESUMEN

Purpose-To evaluate the anatomical and functional outcomes of vitrectomy and epiretinal membrane (ERM) peeling in patients with uveitis. Secondarily, we evaluated the effect of internal limiting membrane (ILM) peeling on surgical outcomes, and of surgery on uveitis activity and, thus, therapeutic regime. Methods-Bicentre, retrospective, interventional case series of 29 eyes of 29 consecutive patients affected by uveitis and ERM, that had undergone pars plana vitrectomy with ERM peel between 2012 and 2020, with a minimum postoperative follow-up (FU) of six-months. Demographic data, best-corrected visual-acuity (BCVA), clinical findings, intraoperative and postoperative complications, and macular optical-coherence-tomography scans were reviewed. Results-The mean (standard deviation) duration of follow-up was 32 (22) months. At six-month FU, mean central-retinal-thickness (CRT) significantly improved (from 456 (99) to 353 (86) microns; p < 0.001), and mean BCVA improved from 0.73 (0.3) to 0.49 (0.36) logMAR (p < 0.001), with only one (3%) patient experiencing worsening of vision. The rate of concomitant cystoid macular edema decreased from 19 (66%) eyes at presentation to eight (28%) eyes at final-FU (p = 0.003). Comparing eyes in which ILM peeling was performed in addition to ERM peeling only, BCVA or CRT reduction were comparable. Only a minority of six (21%) eyes had a worsening in uveitis activity requiring additional medications, whereas most patients resumed the same treatment (52%) or received less treatment (28%) (p = 0.673). Conclusions-Vitrectomy with ERM peeling led to favourable anatomical and functional outcomes in patients with uveitis regardless of whether the ILM is peeled or not. As in most patients, no activation of the uveitis requiring additional medications was noted, we do not recommend changes in anti-inflammatory/immunosuppressive therapy postoperatively.

9.
Int J Retina Vitreous ; 8(1): 61, 2022 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-36057670

RESUMEN

PURPOSE: To measure the visual outcomes, proliferative vitreoretinopathy (PVR) and retinectomy rates following primary rhegmatogenous retinal detachment (RRD) repair, comparing silicone oil (SO) and heavy SO (Densiron). METHODS: Retrospective, continuous comparative study from January 2017 to May 2021 of all primary RRD. Multivariable linear (logMAR gain) and binary-logistic (PVR-C and retinectomy rate) regression models to compare tamponade were performed. Covariates included age, gender, ocular co-morbidities, high myopia, macula-status, giant-retinal-tear (GRT), pre-op vision, PVR-C, oil type, perfluorocarbon-use, combined scleral buckle/vitrectomy, combined phaco-vitrectomy, 360-degrees-endolaser and oil duration. Cases with trauma or less than six-month follow-up were excluded. RESULTS: A total of 259 primary RD were analysed. There were 179 SO patients and 80 Densiron patients that had six-month primary re-detachment in 18 (10.1%) and 8 (10.0%) respectively (p = 1.000). No difference in logMAR gain was detected between tamponade choice on multivariable linear regression. Subsequent glaucoma surgery was 5 (2.8%) and 4 (5.0%) for SO and Densiron patients respectively (p = 0.464). On multivariate binary-logistic regression we found no difference in development of PVR-C between oil tamponades. However, SO had significantly higher subsequent retinectomy rate compared to Densiron (odds ratio 15.3, 95% CI 1.9-125.5, p = 0.011). Duration of oil tamponade was not linked to differences in logMAR gain, PVR-C formation or increased retinectomy rate. CONCLUSIONS: We report no difference in primary anatomical success, number of further RRD surgeries, subsequent glaucoma surgery, visual outcomes, PVR-C between both tamponades on multivariable models. Densiron oil was found to be more retinectomy sparing relative to SO.

13.
BMJ Open Ophthalmol ; 7(1): e000859, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35141418

RESUMEN

OBJECTIVE: Retinal tears are the most common vitreoretinal (VR) emergency and retinopexy aims to reduce the risk of rhegmatogenous retinal detachment (RRD). Currently retinal laser is a required competence by the Royal College of Ophthalmologists for residents. We report 6-month detachment rate and repeat retinopexy rate of VR specialists compared with residents. METHODS AND ANALYSIS: A retrospective, consecutive study of 958 eyes undergoing primary laser retinopexy (slit lamp or indirect laser) from January 2017-2020 was divided into training level by operator: specialty training (ST) 2-3, ST4-5, ST6-7 and VR specialists. RESULTS: We report an overall 6-month RRD rate in 32/958 (3.3%) (ST2-3: 9/221 (4.1%), ST4-5: 15/373 (4.0%), ST6-7: 2/72 (2.8%) and VR specialists: 6/292 (2.1%)). We additionally report a repeat retinopexy rate of 189/958 (19.7%), (ST2-3: 44/221 (19.9%), ST4-5: 80/373 (21.4%), ST6-7: 16/72 (22.8%) and VR specialists: 49/292 (16.8%)]). Multivariable Cox survival regression analysis showed significant risk factors for developing RRD include male gender (p=0.018), high myopia (≤-6.00 Dioptres, p=0.004), ST2-3 (p=0.022) and ST4-5 (p=0.040) (relative to VR specialists) and by ST6-7, no significance was found (p=0.151). Significantly higher repeat retinopexy rates were associated with horseshoe tears (relative to round holes, p<0.001) and high myopia (p=0.026) with no difference between different training levels. CONCLUSION: There was a decreasing trend in RRD rate following primary retinopexy with increase in training. Although junior residents had a higher RRD rate than VR specialists, it was still favourable relative to other large case series. While there was no difference in subsequent laser retinopexy rate between training levels, the retreatment rate was associated with the type of tear and high myopia.


Asunto(s)
Miopía , Desprendimiento de Retina , Humanos , Proteína 1 Similar al Receptor de Interleucina-1 , Rayos Láser , Masculino , Miopía/complicaciones , Desprendimiento de Retina/epidemiología , Estudios Retrospectivos
14.
Eur J Ophthalmol ; 32(1): 534-538, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33573420

RESUMEN

PURPOSE: To review the effect of COVID-19 on rhegmatogenous retinal detachment (RRD) rate following primary retinopexy. METHODS: Retrospective consecutive case series of 183 patients attending Birmingham and Midlands Eye Centre undergoing primary retinopexy (cryotherapy and laser) between March 23rd to June 30th in 2019 (Group 1) and 2020 (Group 2). RESULTS: In total we reviewed 183 retinopexies, 122 in Group 1 and 61 in Group 2, a reduction of 50%. In Group 2 compared to Group 1, we showed a significant difference in characteristics of patients having primary retinopexy with an increase in proportion of male patients from 50 (41.0%) to 39 (63.9%) (p = 0.005), increase in high myopes from 1 (0.8%) to 4 (6.6%) (p = 0.043), more slit lamp laser retinopexy from 83 (68.0%) to 52 (85.2%) (p = 0.013) and less cryopexy from 21 (17.2%) to 2 (3.3%) (p = 0.008). In Group 2, primary retinopexy resulted in significantly more 3-month RRD rate 1 (0.8%) to 5 (8.2%) (p = 0.016). There were no changes in number of patients requiring further retinopexy (p = 1.000). CONCLUSION: This study demonstrates a reduction of primary retinopexy, an increased risk for RRD following primary retinopexy and a significant shift in type of primary retinopexy performed, demographics, operator and change in characteristics of type of retinal break observed during this pandemic. This study contributes to the growing literature of the secondary effects of the COVID-19 pandemic on other aspects of healthcare that is not just limited to the virus itself.


Asunto(s)
COVID-19 , Desprendimiento de Retina , Servicio de Urgencia en Hospital , Hospitales , Humanos , Masculino , Pandemias , Desprendimiento de Retina/cirugía , Estudios Retrospectivos , SARS-CoV-2 , Agudeza Visual , Vitrectomía
15.
Eye (Lond) ; 36(5): 1080-1085, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34035492

RESUMEN

PURPOSE: Retinopexy is the most common vitreo-retinal procedure performed in the eye emergency department and significantly reduces the risk of a rhegmatogenous retinal detachment (RRD). There are various indications for retinopexy, with the most common being horseshoe-tears (HST). Multiple treatment techniques exist, ranging from slit-lamp laser-retinopexy, indirect laser-retinopexy or cryopexy. We report on our primary retinopexy 6-month RRD rate, repeat retinopexy rate and compare outcomes of different indications and treatment modalities. METHODS: Retrospective consecutive case series of 1157 patients attending Birmingham and Midlands Eye Centre, UK between January 2017 and 2020. RESULTS: The RRD rate at 6 months was 3.9%, with 19.1% requiring subsequent retinopexies. Multivariate Cox survival regression analysis showed that significant risk factors for RRD following primary retinopexy included male gender (p = 0.012), high myopia (≤ - 6.00D, p = 0.004), HST (compared to round holes, p = 0.026) and primary cryopexy (compared to slit-lamp laser, p = 0.014). HST was the most common indication for retinopexy (812 [70.2%]) in which 118 (14.5%) had multiple tears. Slit-lamp laser was used in 883 (76.3%) of cases. The rate for subsequent epiretinal membrane peel surgery was 3 (0.3%) and was higher in eyes that required multiple retinopexy procedures (p = 0.035). CONCLUSION: With our large cohort of patients over three years, we provide additional evidence on the RRD and subsequent retinopexy rate after primary retinopexy. Further retinopexy is a common occurrence, particularly in high-risk retinal tears such as HST. Strict monitoring and prompt follow-up after retinopexy is important to prevent progression to RRD and should be of priority in the clinicians post-retinopexy management plan, particularly in those with associated risk factors.


Asunto(s)
Desprendimiento de Retina , Perforaciones de la Retina , Humanos , Masculino , Retina/cirugía , Desprendimiento de Retina/etiología , Perforaciones de la Retina/cirugía , Estudios Retrospectivos , Centros de Atención Terciaria
16.
Acta Ophthalmol ; 100(1): 96-102, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34114735

RESUMEN

PURPOSE: To investigate different baseline characteristics, clinical indications, repeat retinopexy rate, and 6-month detachment rate of primary laser retinopexy across different ethnicities. METHOD: Retrospective, single-centre, consecutive comparative study, looking at all patients who had primary laser retinopexy between January 2017 and 2020. Multivariate Cox survival [reporting hazard ratio (HR)] and binary logistic regression (reporting odds ratio) analyses were performed to investigate differences between ethnicities with age, gender, operator level (vitreoretinal or general ophthalmologist) and high myopia status (≤-6.0 Dioptres) as covariates. RESULTS: We report on 812 patients in three ethnicities: Black [69 (8.5%)], South Asian [SA, 156 (19.2%)] and White [587 (72.3%)] with overall 6-month detachment rate of 31 (3.8%). Rate for subsequent retinopexies was Black: 12 (17.4%), SA: 15 (9.6%) and White: 131 (22.3%), p = 0.002. Multivariate Cox survival regression analysis found no difference in detachment rate between ethnicities. South Asian (SA) had lower repeat retinopexy rate than White patients [HR, 0.40 (95% confidence interval [CI], 0.22-0.71, p = 0.002)]. Multivariate binary logistic regression found that Black and SA patients compared with White, have the following: (i) higher proportion of round holes relative to horseshoe tears [OR, 2.31 (95% CI, 1.19-4.49, p = 0.014) and OR, 2.06 (95% CI, 1.25-3.40), p = 0.004, respectively] and (ii) higher proportion of high myopia [OR, 2.99 (95% CI, 1.20-7.46, p = 0.019) and OR, 2.35 (95% CI, 1.11-4.96), p = 0.025, respectively]. Ethnic minorities were younger than White patients: SA [43, interquartile range (IQR), 28-61], Black (49, IQR, 35-57) and White (61, IQR, 54-67 years, p < 0.001) and had more indirect and 360 retinopexy compared with slit lamp (p < 0.001). CONCLUSION: We demonstrate a significant difference in baseline characteristics, retinal tear morphology and treatment course between the ethnic groups. Further studies are necessary to investigate the genetic and biological differences that may influence these variations and may help to allow for more targeted health care.


Asunto(s)
Etnicidad , Terapia por Láser/métodos , Miopía/complicaciones , Retina/cirugía , Desprendimiento de Retina/prevención & control , Centros de Atención Terciaria/estadística & datos numéricos , Agudeza Visual , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Retina/diagnóstico por imagen , Desprendimiento de Retina/etnología , Desprendimiento de Retina/etiología , Estudios Retrospectivos , Factores de Riesgo , Reino Unido/epidemiología
17.
Ophthalmologica ; 245(3): 239-248, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34818241

RESUMEN

PURPOSE: During bank holidays and weekends (BHWE), many primary macula-on retinal detachments (RD) across the United Kingdom are performed unsupervised out-of-hours by experienced vitreoretinal (VR) fellows. We aimed to determine whether first-year (F1) and second-year (F2) fellows could safely operate out-of-hours independently with remote supervision on primary macula-on RDs. METHODS: This is a retrospective consecutive series of 435 patients attending the Birmingham and Midlands Eye Centre from January 2017 to July 2020. We evaluated (i) 6-month re-detachment rate and (ii) visual outcomes of F1, F2, and consultants during office hours and BHWE as well as the effects of supervision versus non-supervision. RESULTS: For the re-detachment rate, no difference was found between surgeon grade (p = 0.821), whether supervised (p = 1.000), whether BHWE (p = 1.000), unsupervised BHWE and supervised mid-week (p = 0.757), and unsupervised F1 and F2 (p = 1.000), with non-significance maintained on multivariate regression. No difference was detected in the level of supervision (15.7%) between fellow grades during BHWE (p = 0.761) or mid-week (p = 0.295) or between surgeon grade and logMAR letters gained pre-postoperatively (p = 0.834). CONCLUSION: Safe VR services can be provided by experienced VR fellows during office hours, BHWE, supervised, or unsupervised, with similar primary success and visual outcomes to consultants in this patient subgroup. Initial intensive supervision and feedback and a gradual increase in independence is fundamental for VR fellows to gain confidence and become safe independent surgeons.


Asunto(s)
Atención Posterior , Mácula Lútea , Desprendimiento de Retina , Cirugía Vitreorretiniana , Humanos , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/cirugía , Estudios Retrospectivos , Agudeza Visual , Vitrectomía
18.
PLoS One ; 16(11): e0259714, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34752493

RESUMEN

PURPOSE: Socio-economic deprivation and ethnic variation have been frequently linked to poorer health outcomes. We collected a large series of primary macula-on rhegmatogenous retinal detachment (RRD) cases and analysed the effect of socio-economic deprivation and ethnicity on both six-month retinal re-detachment rate and visual outcomes. MATERIALS AND METHODS: Retrospective consecutive case series of 568 patients attending Birmingham and Midlands Eye Centre from January 2017-2020. Multiple Indices of Deprivation (IMD) deciles were used for deprivation status and split to two groups: IMD-A (Decile 1-5) and IMD-B (Decile 6-10). The two largest subgroups of ethnicities were compared, White and South Asians (SA). RESULTS: We report an overall retinal re-detachment rate of 8.5%. IMD-A re-detached significantly more than IMD-B (11.2% vs 6.0% respectively, p = 0.034). No statistical significance was found between White and SA re-detachment rate (9.1% and 5.6% respectively, p = 0.604). SA median age significantly lower at 49 years (IQR: 37-61) compared to White patients at 57 years (IQR: 50-65) (p = <0.001). IMD-A median age of 55 years (IQR: 46-64) was significantly lower to IMD-B median age of 58 years (IQR: 51-65) (p = 0.011). No differences in final visual outcomes were detected across all groups. CONCLUSION: We demonstrated an increased retinal re-detachment rate in our more deprived patients according to IMD and a younger cohort of SA compared to White ethnicity. Further prospective studies are required to demonstrate the link between socio-economic deprivation and surgical success.


Asunto(s)
Desprendimiento de Retina , Adulto , Coroides , Etnicidad , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...