Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 111(7): 077202, 2013 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-23992079

RESUMEN

We study the ternary clathrate Pr3Pd20Si6 in specific heat and ac susceptibility measurements on a high-quality single crystal, distinguishing antiferromagnetic and antiferroquadrupolar ordering, as well as a hitherto unknown magnetic low-temperature transition. The specific heat shows the direct involvement of nuclear spin degrees of freedom in the antiferromagnetic ordering, which is well supported by our calculation of the hyperfine level scheme without adjustable parameters. Pr3Pd20Si6 is, therefore, one of the rare materials where the nuclear moments are involved in the formation of the magnetic ground state.

2.
Ann Nucl Med ; 24(7): 507-14, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20549401

RESUMEN

OBJECTIVE: The aim of this study was to investigate the utility of gated PET/CT and CT attenuation correction (AC) for the quantitation of radioactivity. METHODS: An ellipse phantom containing six spheres, ranging from 10 to 37 mm in diameter, was filled with 36.7 kBq/mL of F-18. The respiratory motion was simulated by a motor-driven plastic platform to move the phantom with a displacement of 2 cm in the craniocaudal direction at a frequency of 15/min. With the phantom at rest, PET/CT data were acquired and used as a standard (nonmotion). With the phantom in motion, PET data were acquired in both the static and gated modes (sPET and gPET, respectively). Helical CT (HCT), slow CT (SCT), average CT (ACT), and four-dimensional CT (4DCT) were acquired and used to correct attenuation. On both PET and CT images, the maximum radioactivity, dimensions, and CT numbers were measured on the central slices. RESULTS: In nonmotion, recovery coefficients whose spheres were 22 mm or smaller gradually decreased. Regarding motion, the PET counts of the spheres in the static acquisition were lower than those acquired in nonmotion with either type of CTAC (sPET-HCT: -43.8%, sPET-SCT: -51.4%, sPET-ACT: -49.5%). Gated acquisition of PET significantly improved the PET counts (gPET-HCT: -30.1%) (p < 0.05), while additional gated acquisition of CT significantly improved them further (gPET-4DCT: -15.2%) (p < 0.01). The dimensions of sPET were overestimated, but those of gPET were close to the standard values. The SCT significantly overestimated the dimensions, and the water density area decreased (p < 0.01). The 4DCT images were similar to the HCT images. CONCLUSIONS: In respiratory motion, PET acquisition in the static mode underestimated the radioactivity and overestimated the dimensions. Neither SCT nor ACT improved these errors. Although PET acquisition in the gated mode improved the quantification of PET/CT images, the additional gated CT acquisition using 4DCT is required for further improvement.


Asunto(s)
Movimiento (Física) , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...