Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 200
Filtrar
1.
Heart Rhythm ; 21(6): 978-989, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38752904

RESUMEN

The field of electrophysiology (EP) has benefited from numerous seminal innovations and discoveries that have enabled clinicians to deliver therapies and interventions that save lives and promote quality of life. The rapid pace of innovation in EP may be hindered by several challenges including the aging population with increasing morbidity, the availability of multiple costly therapies that, in many instances, confer minor incremental benefit, the limitations of healthcare reimbursement, the lack of response to therapies by some patients, and the complications of the invasive procedures performed. To overcome these challenges and continue on a steadfast path of transformative innovation, the EP community must comprehensively explore how artificial intelligence (AI) can be applied to healthcare delivery, research, and education and consider all opportunities in which AI can catalyze innovation; create workflow, research, and education efficiencies; and improve patient outcomes at a lower cost. In this white paper, we define AI and discuss the potential of AI to revolutionize the EP field. We also address the requirements for implementing, maintaining, and enhancing quality when using AI and consider ethical, operational, and regulatory aspects of AI implementation. This manuscript will be followed by several perspective papers that will expand on some of these topics.


Asunto(s)
Inteligencia Artificial , Electrofisiología Cardíaca , Atención a la Salud , Humanos , Investigación Biomédica , Técnicas Electrofisiológicas Cardíacas/métodos
2.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
3.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38448797

RESUMEN

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Lesiones Cardíacas , Venas Pulmonares , Humanos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Lesiones Cardíacas/etiología , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
4.
Heart Rhythm ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38555971

RESUMEN

BACKGROUND: The healing response to cardiac implantable electronic device (CIED) implantation results in inflammation that can lead to fibrous pocket formation, which may disrupt pocket healing or complicate future interventions. OBJECTIVE: The purpose of this study was to assess CIED pocket healing with use of the second-generation TYRX absorbable antibacterial envelope (T2), the next-generation (NG) TYRX absorbable antibacterial envelope under development, and the CanGaroo® extracellular matrix envelope (ECM) compared to no envelope. METHODS: A total of 110 CIEDs were implanted in an ovine model, either with (T2, NG, or ECM) or without envelopes. Histopathologic and morphometric analyses were completed at several timepoints after implant (3 days, 7 days, 4 weeks, 12 weeks, 24 weeks). An independent pathologist completed a blinded histopathology assessment of the pockets. RESULTS: TYRX (T2/NG) pockets showed similar inflammatory and healing profiles to controls with more rapid provisional matrix formation compared to controls and ECM. ECM pockets exhibited increased acute (3 and 7 days) and chronic (24 weeks) inflammation. T2/NG had almost complete (T2) or complete (NG) absorption by week 12. ECM remained present at week 24 and was associated with significantly thicker capsules (ECM 0.80 ± 0.14 mm; NG 0.37 ± 0.10 mm; control 0.56 ± 0.17 mm). CONCLUSION: Compared to ECM, pockets with TYRX showed less inflammation, more rapid provisional matrix formation, faster absorption, and thinner capsules. TYRX pockets had low inflammation comparable to controls with accelerated provisional matrix deposition and tissue adhesion. The healing response to CIEDs used with TYRX fosters the formation of a well-healed pocket, which may bring patient benefit beyond its proven infection reduction.

5.
JACC Clin Electrophysiol ; 10(5): 916-926, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520434

RESUMEN

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (age 63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; 95% CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Prevención Primaria , Humanos , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Masculino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Persona de Mediana Edad , Anciano , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Estados Unidos/epidemiología , Estudios Retrospectivos
6.
Heart Rhythm ; 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38417598

RESUMEN

BACKGROUND: Loading of oral sotalol for atrial fibrillation requires 3 days, frequently in the hospital, to achieve steady state. The Food and Drug Administration approved loading with intravenous (IV) sotalol through model-informed development, without patient data. OBJECTIVE: We present results of the first multicenter evaluation of this recent labeling for IV sotalol. METHODS: The Prospective Evaluation Analysis and Kinetics of IV Sotalol (PEAKS) Registry was a multicenter observational registry of patients undergoing elective IV sotalol load for atrial arrhythmias. Outcomes, measured from hospital admission until first outpatient follow-up, included adverse arrhythmia events, efficacy, and length of stay. RESULTS: Of 167 consecutively enrolled patients, 23% were female; the median age was 68 (interquartile range, 61-74) years, and the median CHA2DS2-VASc score was 3 (interquartile range, 2-4). Overall, 99% were admitted for sotalol initiation (1% for dose escalation), with a target oral sotalol dose of either 80 mg twice daily (85 [51%]) or 120 mg twice daily (78 [47%]); 62 patients (37%) had an estimated creatinine clearance ≤90 mL/min. On presentation, 40% of patients were in sinus rhythm, whereas 26% underwent cardioversion before sotalol infusion. In 2 patients, sotalol infusion was stopped for bradycardia or hypotension. In 6 patients, sotalol was discontinued before discharge because of QTc prolongation (3), bradycardia (1), or recurrent atrial arrhythmia (2). The mean length of stay was 1.1 days, and 95% (n = 159) were discharged within 1 night. CONCLUSION: IV sotalol loading is safe and feasible for atrial arrhythmias, with low rates of adverse events, and yields shorter hospitalizations. More data are needed on the minimal duration required for monitoring in the hospital.

7.
Heart Rhythm ; 21(5): 530-537, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38350520

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. A blanking period (BP) of 3 months is used in clinical trials and practice. However, the optimal BP duration after PVI remains undefined. OBJECTIVE: The aim of this study was to objectively define, using continuous monitoring by an implantable loop recorder, the optimal BP duration after cryoballoon PVI. METHODS: We enrolled consecutive patients who had cryoballoon PVI and an implantable loop recorder. We determined the time of the last confirmed episode of AF within the blanking period. This was then correlated with AF recurrence in the first year after ablation. RESULTS: There were 210 patients (66 ± 9 years; 138 [66%] male; 116 [55%] paroxysmal AF; CHA2DS2-VASc score, 2.5 ± 1.6). We defined 4 distinct groups based on the last AF episode within the BP: no AF days 0-90 (n = 96 [46%]) and last AF 0-30 days (n = 46 [22%]), 31-60 days (n = 18 [9%]), and 61-90 days (n = 50 [24%]). After the 3-month BP, 101 (48%) patients had AF recurrence at 160 ± 86 days. Compared with patients with no AF in the BP, those with recurrent AF and AF burden >0% 30 days after ablation had a significantly greater AF recurrence during long-term follow-up (P = .001). CONCLUSION: Our data show that the approximately one-third of patients in whom AF occurs and who have a burden of >0% after the first month that follows PVI are at significantly higher risk of long-term recurrent AF. We therefore suggest that the blanking period be limited to a month after cryoballoon PVI.


Asunto(s)
Fibrilación Atrial , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Criocirugía/métodos , Anciano , Estudios de Seguimiento , Recurrencia , Resultado del Tratamiento , Electrocardiografía Ambulatoria/métodos , Factores de Tiempo , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios Retrospectivos , Electrocardiografía/métodos
8.
Cardiovasc Digit Health J ; 5(1): 1-7, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38390582

RESUMEN

Background: Remote monitoring (RM) of cardiac implantable electronic device (CIED) patients is now considered standard of care. However, a fundamental requirement of RM is continuous connectivity between the patient's implanted device and the CIED manufacturer's central server. This study examined the rate of RM disconnections in CIED recipients and the impact of short message service (SMS) to facilitate reconnections. Methods: Using a platform that collects RM data from CIED manufacturers, we retrospectively examined the disconnection and reconnection events in 6085 patients from 20 medical centers. Each medical center reported their usual practice regarding RM disconnections, which consisted of either an automatic SMS from the platform to patients who were disconnected for 2 weeks or the standard of care (SC) of a phone call to patients. Results: During a 1-year period, 43% of patients had at least 1 disconnection. Half of these patients experienced multiple disconnections. The use of SMS reduced the time to reconnection by 43% in comparison to SC. The median time to reconnect a disconnected patient was 11.0 [3.2, 29.0] days for SC vs 6.3 [1.3, 22.0] days for SMS (P < .0001). Furthermore, there was a high rate of reconnections within the first 48 hours of the SMS message, which was nearly double that in the SC arm. Conclusion: This study demonstrates the feasibility of an automatic system to deliver an SMS to patients with a disconnected CIED to facilitate early reconnection to RM.

9.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
10.
Am Heart J ; 269: 25-34, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38072334

RESUMEN

BACKGROUND: Objective data comparing the diagnostic performance of different ambulatory cardiac monitors (ACMs) are lacking. OBJECTIVES: To assess variation in monitoring strategy, clinical outcomes and healthcare utilization in patients undergoing ambulatory monitoring without a pre-existing arrhythmia diagnosis. METHODS: Using the full sample (100%) of Medicare claims data, we performed a retrospective cohort study of diagnostic-naïve patients who received first-time ACM in 2017 to 2018 and evaluated arrhythmia encounter diagnosis at 3-months, repeat ACM testing at 6 months, all-cause 90-day emergency department (ED) and inpatient utilization, and cost of different strategies: Holter; long-term continuous monitor (LTCM); non-continuous, event-based external ambulatory event monitor (AEM); and mobile cardiac telemetry (MCT). We secondarily performed a device-specific analysis by manufacturer, identified from unique claim modifier codes. RESULTS: ACMs were used in 287,789 patients (AEM = 10.3%; Holter = 53.8%; LTCM = 13.3%; MCT = 22.5%). Device-specific analysis showed that compared to Holter, AEM, MCT, or other LTCM manufacturers, a specific LTCM (ZioⓇ XT 14-day patch, iRhythm Technologies, San Francisco, CA) had the highest adjusted odds of diagnosis and lowest adjusted odds of ACM retesting. Findings were consistent for specific arrhythmia diagnoses of ventricular tachycardia, atrioventricular block, and paroxysmal atrial fibrillation. As a category, LTCM was associated with the lowest 1-year incremental health care expenditures (mean Δ$10,159), followed by Holter ($10,755), AEM ($11,462), and MCT ($12,532). CONCLUSIONS: There was large variation in diagnostic monitoring strategy. A specific LTCM was associated with the highest adjusted odds of a new arrhythmia diagnosis and lowest adjusted odds of repeat ACM testing. LTCM as a category had the lowest incremental acute care utilization. Different monitoring strategies may produce different results with respect to diagnosis and care.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Metacrilatos , Estados Unidos , Humanos , Anciano , Estudios Retrospectivos , Medicare , Fibrilación Atrial/diagnóstico , Gastos en Salud , Aceptación de la Atención de Salud
14.
J Arrhythm ; 39(3): 250-302, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37324757

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

15.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37211145

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Desfibriladores Implantables , Tecnología de Sensores Remotos , Humanos
16.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208301

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Monitoreo Fisiológico , Telemetría , Humanos
17.
Circ Arrhythm Electrophysiol ; 16(5): e011740, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36960716

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) infection has a high mortality. Previous investigations showed reduced postoperative infections using skin preparation with chlorhexidine, preoperative intravenous antibiotics, and a TYRX-a antibacterial envelope. The additional benefit of antibiotic pocket wash and postoperative antibiotics has not been systematically studied. METHODS: The ENVELOPE trial (A Randomized trial of Stand-Alone Use of the Antimicrobial Envelope in High-Risk Cardiac Device Patients) was a prospective, multicenter, randomized, controlled trial enrolling patients undergoing CIED procedures with ≥2 risk factors for infection. The control arm received standard chlorhexidine skin preparation, intravenous antibiotics, and the TYRX-a antibiotic envelope. The study arm received pocket wash (500 mL antibiotic solution) and postoperative antibiotics for 3 days along with the prophylactic control measures. The primary end point was CIED infection and system removal at 6 months. RESULTS: One thousand ten subjects (505 per arm) were enrolled and randomized. Patients were seen in person for a wound check with digital photo 2 weeks postimplant and at 3 and 6 months. CIED infection rate was low in both groups (1.0% control arm and 1.2% study arm, P=0.74). In the 11 subjects with infection and system removal, the time to study end point was 107±92 days with a PADIT (Prevention of Arrhythmia Device Infection Trial) score of 7.4 and a 64% 1-year mortality. Prior history of CIED infection independently predicted CIED system removal at 6 months in all subjects (odds ratio, 9.77, P=0.004). Of 11 infections requiring system removal, 5 were in the setting of pocket hematoma. CONCLUSIONS: The use of antibiotic pocket irrigation and postoperative oral antibiotics provides no additional benefit to the prophylactic measures of chlorhexidine skin preparation, preoperative intravenous antibiotics, and an antibiotic envelope in reducing CIED infection. Postoperative hematoma is a major risk factor for infection, driven by the use of antiplatelet and anticoagulant medications. The strongest predictor of CIED removal at 6 months, regardless of intervention, was prior CIED infection. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02809131.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Desfibriladores Implantables/efectos adversos , Estudios Prospectivos , Clorhexidina , Antibacterianos/uso terapéutico , Cardiopatías/complicaciones , Hematoma/etiología , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Marcapaso Artificial/efectos adversos
18.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922042

RESUMEN

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Vías Clínicas , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos
19.
Heart Rhythm ; 20(6): 833-841, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813092

RESUMEN

BACKGROUND: Rates of early mortality and complications after catheter ablation (CA) of atrial fibrillation (AF) vary across health care settings. OBJECTIVE: The purpose of this study was to identify the rate and predictors of early mortality (within 30 days) after CA in the inpatient and outpatient settings. METHODS: Using the Medicare Fee for Service database, we analyzed 122,289 patients who underwent CA for treatment of AF between 2016 and 2019 to define 30-day mortality in both inpatients and outpatients. Odds of adjusted mortality were assessed with several methods, including inverse probability of treatment weighting. RESULTS: Mean age was 71.9 ± 6.7 years, 44% were women, and mean CHA2DS2-VASc score was 3.2 ± 1.7. Overall, 82% underwent AF ablation as an outpatient. Mortality rate 30 days after CA was 0.6%, with inpatients accounting for 71.5% of deaths (P <.001). Early mortality rates were 0.2% for outpatient procedures and 2.4% for inpatient procedures. The prevalence of comorbidities was significantly higher in patients with early mortality. Patients with early mortality had significantly higher rates of postprocedural complications. After adjustment, inpatient ablation was significantly associated with early mortality (adjusted odds ratio [aOR] 3.81; 95% confidence interval [CI] 2.87-5.08; P <.001). Hospitals with high overall ablation volume had 31% lower odds of early mortality (highest vs lowest tertile: aOR 0.69; 95% CI 0.56-0.86; P <.001). CONCLUSION: AF ablation conducted in the inpatient setting is associated with a higher rate of early mortality compared with outpatient AF ablation. Comorbidities are associated with enhanced risk of early mortality. High overall ablation volume is associated with a lower risk of early mortality.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Femenino , Humanos , Masculino , Fibrilación Atrial/mortalidad , Ablación por Catéter/métodos , Pacientes Internos , Medicare , Pacientes Ambulatorios , Medición de Riesgo/métodos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36448428

RESUMEN

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Alta del Paciente , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Satisfacción del Paciente , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...