Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Huntingtons Dis ; 10(2): 293-301, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33814455

RESUMEN

BACKGROUND: Current Huntington's disease (HD) measures are limited to subjective, episodic assessments conducted in clinic. Smartphones can enable the collection of objective, real-world data but their use has not been extensively evaluated in HD. OBJECTIVE: Develop and evaluate a smartphone application to assess feasibility of use and key features of HD in clinic and at home. METHODS: We developed GEORGE®, an Android smartphone application for HD which assesses voice, chorea, balance, gait, and finger tapping speed. We then conducted an observational pilot study of individuals with manifest HD, prodromal HD, and without a movement disorder. In clinic, participants performed standard clinical assessments and a battery of active tasks in GEORGE. At home, participants were instructed to complete the activities thrice daily for one month. Sensor data were used to measure chorea, tap rate, and step count. Audio data was not analyzed. RESULTS: Twenty-three participants (8 manifest HD, 5 prodromal HD, 10 controls) enrolled, and all but one completed the study. On average, participants used the application 2.1 times daily. We observed a significant difference in chorea score (HD: 19.5; prodromal HD: 4.5, p = 0.007; controls: 4.3, p = 0.001) and tap rate (HD: 2.5 taps/s; prodromal HD: 8.9 taps/s, p = 0.001; controls: 8.1 taps/s, p = 0.001) between individuals with and without manifest HD. Tap rate correlated strongly with the traditional UHDRS finger tapping score (left hand: r = -0.82, p = 0.022; right hand: r = -0.79, p = 0.03). CONCLUSION: GEORGE is an acceptable and effective tool to differentiate individuals with and without manifest HD and measure key disease features. Refinement of the application's interface and activities will improve its usability and sensitivity and, ideally, make it useful for clinical care and research.


Asunto(s)
Enfermedad de Huntington/terapia , Aplicaciones Móviles , Monitoreo Ambulatorio/métodos , Teléfono Inteligente , Adulto , Anciano , Femenino , Análisis de la Marcha , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto
2.
Arthroplast Today ; 6(4): 850-855, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33088883

RESUMEN

BACKGROUND: Determining discharge disposition after total joint arthroplasty (TJA) has been a challenge. Advances in machine learning (ML) have produced computer models that learn by example to generate predictions on future events. We hypothesized a trained ML algorithm's diagnostic accuracy will be better than that of current predictive tools to predict discharge disposition after primary TJA. METHODS: This study was a retrospective cohort study from a single, tertiary referral center for primary TJA. We trained and validated an artificial neural network (ANN) based on 4368 distinct surgical encounters between 1/1/2013 and 6/28/2016. The ANN's ability to identify discharge disposition was then tested on 1452 distinct surgical encounters between 1/3/17 and 11/30/17. RESULTS: The area under the curve and accuracy achieved during model validation were 0.973 and 91.7%, respectively, with 25% of patients being discharged to skilled nursing facilities (SNFs). Within our testing data set, 6.7% of patients went to SNFs. The performance in the testing set included an area under the curve of 0.804, accuracy of 61.3%, sensitivity of 28.9%, and specificity of 93.8%. CONCLUSIONS: This is the first prediction tool using an electronic medical record-integrated ANN to predict discharge disposition after TJA based on locally generated data. Dramatically reduced numbers of patients discharged to SNFs due to implementation of a bundled payment model lead to poor recall in the testing model. This model serves as a proof of concept for developing an ML prediction tool using a relatively small data set and subsequent integration into the electronic medical record.

3.
Hand (N Y) ; 15(2): 185-193, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-30073845

RESUMEN

Background: Patient-Reported Outcomes Measurement Information System (PROMIS) can be used alongside preoperative patient characteristics to set postsurgery expectations. This study aimed to analyze whether preoperative scores can predict significant postoperative PROMIS score improvement. Methods: Patients undergoing hand and wrist surgery with initial and greater than 6-month follow-up PROMIS scores were assigned to derivation or validation cohorts, separating trauma and nontrauma conditions. Receiver operating characteristic curves were calculated for the derivation cohort to determine whether preoperative PROMIS scores could predict postoperative PROMIS score improvement utilizing minimal clinically important difference principles. Results: In the nontrauma sample, patients with baseline Physical Function (PF) scores below 31.0 and Pain Interference (PI) and Depression scores above 68.2 and 62.2, respectively, improved their postoperative PROMIS scores with 95%, 96%, and 94% specificity. Patients with baseline PF scores above 52.1 and PI and Depression scores below 49.5 and 39.5, respectively, did not substantially improve their postoperative PROMIS scores with 94%, 93%, and 96% sensitivity. In the trauma sample, patients with baseline PF scores below 34.8 and PI and Depression scores above 69.2 and 62.2, respectively, each improved their postoperative PROMIS scores with 95% specificity. Patients with baseline PF scores above 52.1 and PI and Depression scores below 46.6 and 44.0, respectively, did not substantially improve their postoperative scores with 95%, 94%, and 95% sensitivity. Conclusions: Preoperative PROMIS PF, PI, and Depression scores can predict postoperative PROMIS score improvement for a select group of patients, which may help in setting expectations. Future work can help determine the level of true clinical improvement these findings represent.


Asunto(s)
Mano , Medición de Resultados Informados por el Paciente , Estudios de Cohortes , Femenino , Mano/cirugía , Humanos , Masculino , Diferencia Mínima Clínicamente Importante , Periodo Posoperatorio
4.
Musculoskeletal Care ; 17(1): 120-125, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30615249

RESUMEN

OBJECTIVES: The Patient-Reported Outcomes Measurement Information System (PROMIS) is growing in popularity as healthcare shifts towards a value-based system. However, it remains unclear if PROMIS use improves the patient experience. The aim of the present study was to determine if PROMIS use as part of routine orthopaedic clinical care is associated with improved patient experience, as measured by the Clinician and Group Consumer Assessment of Healthcare Providers and Systems (CGCAHPS) survey. METHODS: All patient visits to an orthopaedic surgery clinic at a single academic medical centre between February 2015 and September 2016 were reviewed. Accounting for known patient factors that have an impact on clinic visit satisfaction, CGCAHPS scores were compared between patients who had PROMIS used as part of their routine care and those who had not had PROMIS used as part of their routine care. A p-value of <0.05 was considered significant. RESULTS: A total of 8,607 patient visits fitted our inclusion criteria. Of these, surgeons elected not to use PROMIS in 8,422 patient encounters, leaving 185 patient visits in which PROMIS was actively used. When PROMIS was used, patients were significantly more likely to feel that the provider had spent enough time with them, to recommend this provider office to another patient and to rate the provider significantly higher on a scale from 0 to 10. Although not significant, a trend was found between use of PROMIS and whether a patient felt that a provider explained health information in way that the patient understood. CONCLUSIONS: PROMIS use in an orthopaedic clinic visit can have a positive impact on the patient experience, which is currently part of a number of alternative payment models.


Asunto(s)
Instituciones de Atención Ambulatoria , Ortopedia , Medición de Resultados Informados por el Paciente , Satisfacción del Paciente , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mejoramiento de la Calidad
5.
Plast Reconstr Surg ; 136(2): 328-330, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26218380

RESUMEN

This pilot study investigated the feasibility of Google Glass to assist visualization of fluoroscopic images during percutaneous pinning of hand fractures. Cadavers were used to compare total time to pin each fracture and total number of radiographs per fracture from a mini C-arm. A FluoroScan monitor was used for radiographic visualization compared to projecting the images in the Google Glass display. All outcome measures significantly improved for proximal phalanx fractures (127 versus 86 seconds, p = 0.017; 5.3 versus 2.2 images, p = 0.003), and fewer images were obtained during fixation of metacarpal fractures using Google Glass compared with traditional techniques (6.4 versus 3.6, p < 0.001). Typical FluoroScan monitor placement may require the surgeon to alter focus away from the operative field, whereas Google Glass allows constant attention directed toward the operative field.


Asunto(s)
Traumatismos de los Dedos/cirugía , Fijación de Fractura/instrumentación , Fracturas Óseas/cirugía , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Cadáver , Estudios de Factibilidad , Femenino , Traumatismos de los Dedos/diagnóstico , Fluoroscopía/métodos , Fijación de Fractura/métodos , Fracturas Óseas/diagnóstico , Humanos , Masculino , Proyectos Piloto , Sensibilidad y Especificidad
6.
J Orthop Res ; 27(6): 833-40, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19051246

RESUMEN

Tendon injury frequently results in the formation of adhesions that reduce joint range of motion. To study the cellular, molecular, and biomechanical events involved in intrasynovial tendon healing and adhesion formation, we developed a murine flexor tendon healing model in which the flexor digitorum longus (FDL) tendon of C57BL/6 mice was transected and repaired using suture. This model was used to test the hypothesis that murine flexor tendons heal with differential expression of matrix metalloproteases (MMPs), resulting in the formation of scar tissue as well as the subsequent remodeling of scar and adhesions. Healing tendons were evaluated by histology, gene expression via real-time RT-PCR, and in situ hybridization, as well as biomechanical testing to assess the metatarsophalangeal (MTP) joint flexion range of motion (ROM) and the tensile failure properties. Tendons healed with a highly disorganized fibroblastic tissue response that was progressively remodeled through day 35 resulting in a more organized pattern of collagen fibers. Initial repair involved elevated levels of Mmp-9 at day 7, which is associated with catabolism of damaged collagen fibers. High levels of Col3 are consistent with scar tissue, and gradually transition to the expression of Col1. Scleraxis expression peaked at day 7, but the expression was limited to the original tendon adjacent to the injury site, and no expression was present in granulation tissue involved in the repair response. The MTP joint ROM with standardized force on the tendon was decreased on days 14 and 21 compared to day 0, indicating the presence of adhesions. Peak expressions of Mmp-2 and Mmp-14 were observed at day 21, associated with tendon remodeling. At day 28, two genes associated with neotendon formation, Smad8 and Gdf-5, were elevated and an improvement in MTP ROM occurred. Tensile strength of the tendon progressively increased, but by 63 days the repaired tendons had not reached the tensile strength of normal tendon. The murine model of primary tendon repair, described here, provides a novel mechanism to study the tendon healing process, and further enhances the understanding of this process at the molecular, cellular, and biomechanical level.


Asunto(s)
Metaloproteinasas de la Matriz/genética , Membrana Sinovial/lesiones , Membrana Sinovial/fisiología , Traumatismos de los Tendones/fisiopatología , Adherencias Tisulares/fisiopatología , Cicatrización de Heridas/fisiología , Animales , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/genética , Fenómenos Biomecánicos , Cicatriz/patología , Cicatriz/fisiopatología , Colágeno Tipo I/genética , Colágeno Tipo III/genética , Modelos Animales de Enfermedad , Femenino , Expresión Génica/fisiología , Metaloproteinasa 14 de la Matriz/genética , Metaloproteinasa 2 de la Matriz/genética , Metaloproteinasa 9 de la Matriz/genética , Ratones , Ratones Endogámicos C57BL , Membrana Sinovial/citología , Traumatismos de los Tendones/patología , Adherencias Tisulares/patología
7.
J Orthop Res ; 26(6): 824-33, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18186128

RESUMEN

Reconstruction of flexor tendons often results in adhesions that compromise joint flexion. Little is known about the factors involved in the formation of flexor tendon graft adhesions. In this study, we developed and characterized a novel mouse model of flexor digitorum longus (FDL) tendon reconstruction with live autografts or reconstituted freeze-dried allografts. Grafted tendons were evaluated at multiple time points up to 84 days post-reconstruction. To assess the flexion range of the metatarsophalangeal joint, we developed a quantitative outcome measure proportional to the resistance to tendon gliding due to adhesions, which we termed the Gliding Coefficient. At 14 days post-grafting, the Gliding Coefficient was 29- and 26-fold greater than normal FDL tendon for both autografts and allografts, respectively (p < 0.001), and subsequently doubled for 28-day autografts. Interestingly, there were no significant differences in maximum tensile force or stiffness between live autograft and freeze-dried allograft repairs over time. Histologically, autograft healing was characterized by extensive remodeling and exuberant scarring around both the ends and the body of the graft, whereas allograft scarring was abundant only near the graft-host junctions. Gene expression of GDF-5 and VEGF were significantly increased in 28-day autografts compared to allografts and to normal tendons. These results suggest that the biomechanical advantages for tendon reconstruction using live autografts over devitalized allografts are minimal. This mouse model can be useful in elucidating the molecular mechanisms in tendon repair and can aid in preliminary screening of molecular treatments of flexor tendon adhesions.


Asunto(s)
Tendón Calcáneo/fisiología , Tendón Calcáneo/trasplante , Procedimientos Ortopédicos/métodos , Procedimientos de Cirugía Plástica/métodos , Adherencias Tisulares/prevención & control , Tendón Calcáneo/patología , Actinas/genética , Animales , Fenómenos Biomecánicos , Proteínas Morfogenéticas Óseas/genética , Liofilización , Expresión Génica , Factor 5 de Diferenciación de Crecimiento , Articulación Metatarsofalángica/fisiología , Ratones , Ratones Endogámicos C57BL , Modelos Animales , Rango del Movimiento Articular , Adherencias Tisulares/patología , Adherencias Tisulares/fisiopatología , Factor de Crecimiento Transformador beta1/genética , Trasplante Autólogo , Trasplante Homólogo , Factor A de Crecimiento Endotelial Vascular/genética
8.
Mol Ther ; 16(3): 466-73, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18180771

RESUMEN

Tendon reconstruction using grafts often results in adhesions that limit joint flexion. These adhesions are precipitated by inflammation, fibrosis, and the paucity of tendon differentiation signals during healing. In order to study this problem, we developed a mouse model in which the flexor digitorum longus (FDL) tendon is reconstructed using a live autograft or a freeze-dried allograft, and identified growth and differentiation factor 5 (Gdf5) as a therapeutic target. In this study we have investigated the potential of rAAV-Gdf5 -loaded freeze-dried tendon allografts as "therapeutically endowed" tissue-engineering scaffolds to reduce adhesions. In reporter gene studies we have demonstrated that recombinant adeno-associated virus (rAAV)-loaded tendon allografts mediate efficient transduction of adjacent soft tissues, with expression peaking at 7 days. We have also demonstrated that the rAAV-Gdf5 vector significantly accelerates wound healing in an in vitro fibroblast scratch model and, when loaded onto freeze-dried FDL tendon allografts, improves the metatarsophalangeal (MTP) joint flexion to a significantly greater extent than the rAAV-lacZ controls do. Collectively, our data demonstrate the feasibility and efficacy of therapeutic tendon allograft processing as a novel paradigm in tissue engineering in order to address difficult clinical problems such as tendon adhesions.


Asunto(s)
Proteínas Morfogenéticas Óseas/fisiología , Artropatías/terapia , Tendones/trasplante , Ingeniería de Tejidos/métodos , Animales , Proteínas Morfogenéticas Óseas/genética , Dependovirus/genética , Liofilización , Terapia Genética/métodos , Vectores Genéticos/genética , Factor 5 de Diferenciación de Crecimiento , Inmunohistoquímica , Artropatías/genética , Cinética , Ratones , Ratones Endogámicos C57BL , Reacción en Cadena de la Polimerasa , Andamios del Tejido , Transducción Genética , Trasplante Homólogo , Cicatrización de Heridas/genética , Cicatrización de Heridas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...