Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Orthop Translat ; 48: 156-162, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39247790

RESUMEN

Background: The aim of this study was to assess the prevalence, microbiological spectrum, risk factors, and clinical outcomes of unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic and unclear revision-total-hip-/knee-arthroplasties (rTHA and rTKA) compared to culture-negative (CN) revisions. Methods: This study reviewed all International-consensus-meeting-2018 (ICM 2018) negative or inconclusive rTHA (n = 751) and rTKA (n = 679) performed at our institution from 2011 to 2020 with a minimum follow-up of two years. A Kaplan-Meier-analysis was performed to determine the septic and aseptic-free implant survival in cases with UPIC's and matched culture-negative cases. Patient demographics, risk factors, microbiological spectrum and clinical outcomes were evaluated. Results: There were significantly more UPIC cases in rTHA 196/751 (26.1 %) compared to rTKA 113/679 (16.6 %); (p < 0.001). UPICs in rTKA and rTHA have a lower septic and aseptic implant-free-survival compared to CN revisions. Patients with a history of nickel allergy have a higher risk of an UPIC in rTHA and rTKA (p < 0.001). Septic re-revisions after UPIC had a significantly (H: p = 0.004; K: p = 0.030) shorter time period to the primary/previous surgery (H: 84 (IQR:41-797); K: 115 (IQR:55-446)) compared to patients with aseptic re-revisions after UPIC (H:1248 (IQR:178-3534); K: 827 (IQR:361-1183)). Conclusion: UPICs have a higher rate of septic and aseptic failure than CN outcomes. UPICs are twice as common in rTHA compared to rTKA. Preoperative PJI workup reduces the UPIC rate. Nickel allergy is a risk factor for UPIC. Early revisions with UPICs after primary THA or TKA have a higher risk of septic failure. The translational potential of this article: This article provides new information on revision rates for UPIC and potential risk factors for UPIC and its treatment failure.

2.
J Arthroplasty ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39127312

RESUMEN

BACKGROUND: Ceramic femoral heads with titanium sleeves are commonly used in revision total hip arthroplasty (rTHA). Companies advise against combination with a retained femoral component from another manufacturer. However, no data are available. The aim of this study was to evaluate and compare the implant failure and revision rates of ceramic heads with a 12/14 titanium sleeve used on manufacturer-compatible versus noncompatible retained femoral components. METHODS: A retrospective single-center cohort analysis was performed using a prospectively maintained institutional arthroplasty registry. We identified 439 patients who received a titanium 12/14 ceramic head during rTHA between January 1, 2007, and December 31, 2022. There were 229 manufacturer-compatible and 210 manufacturer-noncompatible retained femoral stems, according to the company's official product compatibility list. Implant failure and rerevision rates were evaluated. RESULTS: After a median follow-up of 6.6 years (IQR (interquartile range): 4.5 to 9.3), there was no significant difference (P = 0.770) in the rerevision rate between the manufacturer-compatible group (17.0%) and the noncompatible group (18.1%). Revision-free survival after rTHA was 81.2% in the manufacturer-compatible group and 78.9% in the manufacturer-noncompatible group after 15 years (P = 0.653). Most rerevisions occurred in the first year after rTHA, with 29 of 229 (12.7%) in the manufacturer-compatible group and 24 of 210 (11.4%) in the manufacturer-noncompatible group (P = 0.705). We observed only one implant failure in the manufacturer-noncompatible group, but this was not related to a mismatch problem. CONCLUSIONS: Although legal uncertainties remain, this study showed no increased risk of implant failure or revision rates when a ceramic femoral head, with a 12/14 titanium sleeve, was used on a noncompatible femoral stem from a manufacturer.

3.
J Arthroplasty ; 39(10): 2575-2580, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39004387

RESUMEN

BACKGROUND: There is only sparse knowledge on the psychological burden of patients who have periprosthetic joint infections. The aim of our study was to assess the need for psychological support following total joint arthroplasty of the hip and knee. A special focus was set on patients who had aseptic and septic complications. METHODS: A total of 13,976 patients who underwent total hip (n = 6,926) or total knee arthroplasty (n = 7,050) between January 1, 2012 and December 31, 2019 at a single institution were retrospectively evaluated for the postoperative need for a psychological consultation. Data were collected on age, sex, type of surgery, and indications for revision procedures. The need for a psychological consultation was assessed during the daily postoperative visits, which were further coordinated by 2 institutional psychologists. RESULTS: The average age was 68 years (range, 12 to 100), and there were 63.5% women. The overall rate of psychological consultations was 1.7%. Patients who had a septic indication for revision surgery had an 18.7-fold higher rate of postoperative psychological consultations compared to patients following primary surgery and a 5.4-fold higher rate compared to patients who had an aseptic indication. In detail, this rate was 1.0% in the primary subgroup, compared to 7.7% following revision arthroplasty (P < .001). In the revision subgroup, the rate was 17.9% for septic and 3.3% for aseptic revision arthroplasty cases (P < .001). Postoperative psychological consultations were twice as frequent in women (2.1%) compared to men (1.0%), P < .001. CONCLUSIONS: The present study raises awareness of the markedly high psychological burden in revision arthroplasty cases, in the view of the high estimated number of unknown cases. There is a significant correlation between periprosthetic joint infectionsand the postoperative need for a psychological consultation, with women being at an even higher risk. Health care providers should aim at offering psychological support for patients who have a septic complication, with affected patients being at risk for psychological stress. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Femenino , Masculino , Infecciones Relacionadas con Prótesis/psicología , Anciano , Artroplastia de Reemplazo de Cadera/psicología , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/psicología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Anciano de 80 o más Años , Reoperación/psicología , Reoperación/estadística & datos numéricos , Adulto , Adolescente , Adulto Joven
4.
J Clin Med ; 13(14)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39064162

RESUMEN

Background/Objectives: scoliosis is a three-dimensional structural deformity characterized by lateral and rotational curvature of the spine. The current gold-standard method to assess scoliosis is the measurement of lateral curvature of the spine using the Cobb angle in coronal plane radiographs. The interrater variability for Cobb angle measurements reaches up to 10°. The purpose of this study was to describe and assess the performance of a fully automated method for measuring Cobb angles using a commercially available artificial intelligence (AI) model trained on over 17,000 images, and investigate its interrater/intrarater agreement with a reference standard. Methods: in total, 196 AP/PA full-spine radiographs were included in this study. A reference standard was established by four radiologists, defined as the median of their Cobb angle measurements. Independently, an AI-based software, IB Lab SQUIRREL (version 1.0), also performed Cobb angle measurements on the same radiographs. Results: after comparing the readers' Cobb angle end vertebrae selection to the AI's outputs, 194 curvatures were considered valid for performance assessment, displaying an accuracy of 88.58% in end vertebrae selection. The AI's performance showed very low absolute bias, with a mean difference and standard deviation of differences from the reference standard of 0.16° ± 0.35° in the Cobb angle measurements. The ICC comparing the reference standard and the AI's measurements was 0.97. Conclusions: the AI model demonstrated good results in the determination of end vertebrae and excellent results in automated Cobb angle measurements compared to radiologists and could serve as a reliable tool in clinical practice and research.

5.
Bone Joint Res ; 13(7): 353-361, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38981611

RESUMEN

Aims: This study aimed to evaluate the BioFire Joint Infection (JI) Panel in cases of hip and knee periprosthetic joint infection (PJI) where conventional microbiology is unclear, and to assess its role as a complementary intraoperative diagnostic tool. Methods: Five groups representing common microbiological scenarios in hip and knee revision arthroplasty were selected from our arthroplasty registry, prospectively maintained PJI databases, and biobank: 1) unexpected-negative cultures (UNCs), 2) unexpected-positive cultures (UPCs), 3) single-positive intraoperative cultures (SPCs), and 4) clearly septic and 5) aseptic cases. In total, 268 archived synovial fluid samples from 195 patients who underwent acute/chronic revision total hip or knee arthroplasty were included. Cases were classified according to the International Consensus Meeting 2018 criteria. JI panel evaluation of synovial fluid was performed, and the results were compared with cultures. Results: The JI panel detected microorganisms in 7/48 (14.5%) and 15/67 (22.4%) cases related to UNCs and SPCs, respectively, but not in cases of UPCs. The correlation between JI panel detection and infection classification criteria for early/late acute and chronic PJI was 46.6%, 73%, and 40%, respectively. Overall, the JI panel identified 12.6% additional microorganisms and three new species. The JI panel pathogen identification showed a sensitivity and specificity of 41.4% (95% confidence interval (CI) 33.7 to 49.5) and 91.1% (95% CI 84.7 to 94.9), respectively. In total, 19/195 (9.7%) could have been managed differently and more accurately upon JI panel evaluation. Conclusion: Despite its microbial limitation, JI panel demonstrated clinical usefulness by complementing the traditional methods based on multiple cultures, particularly in PJI with unclear microbiological results.

6.
Arch Orthop Trauma Surg ; 144(3): 1029-1038, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38091069

RESUMEN

INTRODUCTION: The assessment of the knee alignment on long leg radiographs (LLR) postoperative to corrective knee osteotomies (CKOs) is highly dependent on the reader's expertise. Artificial Intelligence (AI) algorithms may help automate and standardise this process. The study aimed to analyse the reliability of an AI-algorithm for the evaluation of LLRs following CKOs. MATERIALS AND METHODS: In this study, we analysed a validation cohort of 110 postoperative LLRs from 102 patients. All patients underwent CKO, including distal femoral (DFO), high tibial (HTO) and bilevel osteotomies. The agreement between manual measurements and the AI-algorithm was assessed for the mechanical axis deviation (MAD), hip knee ankle angle (HKA), anatomical-mechanical-axis-angle (AMA), joint line convergence angle (JLCA), mechanical lateral proximal femur angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibia angle (mMPTA) and mechanical lateral distal tibia angle (mLDTA), using the intra-class-correlation (ICC) coefficient between the readers, each reader and the AI and the mean of the manual reads and the AI-algorithm and Bland-Altman Plots between the manual reads and the AI software for the MAD, HKA, mLDFA and mMPTA. RESULTS: In the validation cohort, the AI software showed excellent agreement with the manual reads (ICC: 0.81-0.99). The agreement between the readers (Inter-rater) showed excellent correlations (ICC: 0.95-0. The mean difference in the DFO group for the MAD, HKA, mLDFA and mMPTA were 0.50 mm, - 0.12°, 0.55° and 0.15°. In the HTO group the mean difference for the MAD, HKA, mLDFA and mMPTA were 0.36 mm, - 0.17°, 0.57° and 0.08°, respectively. Reliable outputs were generated in 95.4% of the validation cohort. CONCLUSION:  he application of AI-algorithms for the assessment of lower limb alignment on LLRs following CKOs shows reliable and accurate results. LEVEL OF EVIDENCE: Diagnostic Level III.


Asunto(s)
Inteligencia Artificial , Osteoartritis de la Rodilla , Masculino , Humanos , Reproducibilidad de los Resultados , Pierna , Estudios Retrospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Extremidad Inferior , Tibia/diagnóstico por imagen , Tibia/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos
7.
J Arthroplasty ; 39(4): 1069-1074, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37866461

RESUMEN

BACKGROUND: Data regarding the diagnostic value of ultrasound (US)-determined fluid film and joint aspiration prior to revision total hip arthroplasty for suspected periprosthetic joint infections (PJIs) are limited. This study aimed to analyze the value of US-determined fluid film, characterized the preoperative and intraoperative microbiological spectrum and resistance patterns, and compared the concordance between preoperative synovial fluid and intraoperative culture results. METHODS: We analyzed 366 US examinations from 324 patients prior to revision total hip arthroplasty. Selected cases were grouped into clearly infected, noninfected, and inconclusive cohorts, according to the International Consensus Meeting 2018 Criteria. For US-determined fluid film <1 mm, no aspiration was performed based on our institutional protocol. Patients were grouped into no aspiration (144 of 366; [39.3%]), dry tap (21 of 366; [5.7%]), and a successful tap (201 of 366; [54.9%]). The microbiological spectrum and antibiograms were compared between preoperative and intraoperative results. RESULTS: The absence of US-determined fluid film showed no correlation with the presence of a hip PJI. Overall, 31.9% cases of the no-aspiration group had a PJI. In total, 13.5% discrepancies were found between successful taps and intraoperative cultures. The most prevalent microorganisms in preoperative synovial fluid were Staphylococcus epidermidis and Staphylococcus aureus (20.8%), while intraoperatively S. epidermidis (26.3%) and Cutibacterium acnes (14.5%) were leading. Additional microorganisms were identified in 32.5% of intraoperative cultures. There were no differences between resistance patterns of preoperative and intraoperative concordant microorganisms. CONCLUSIONS: Absence of US-determined fluid film cannot rule out the presence of a hip PJI. Combined microbiological results from hip US aspirations and subsequent surgical procedures are crucial to design an effective treatment for suspected hip PJI.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Prótesis de Cadera/microbiología , Sensibilidad y Especificidad , Líquido Sinovial , Staphylococcus aureus , Reoperación , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos
9.
Knee Surg Sports Traumatol Arthrosc ; 31(10): 4220-4230, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37286901

RESUMEN

PURPOSE: Osteoarthritis of the knee is commonly associated with malalignment of the lower limb. Recent classifications, as the Coronal Plane Alignment of the Knee (CPAK) and Functional Phenotype classification, describe the bony knee morphology in addition to the overall limb alignment. Data on distribution of these classifications is not sufficient in large populations. The aim of this study was to analyse the preoperative knee morphology with regard to the aforementioned classifications in long leg radiographs prior to total knee arthroplasty surgery using Artificial Intelligence. METHODS: The cohort comprised 8739 preoperative long leg radiographs of 7456 patients of all total knee arthroplasty surgeries between 2009 and 2021 from our institutional database. The automated measurements were performed with the validated Artificial Intelligence software LAMA (ImageBiopsy Lab, Vienna) and included standardized axes and angles [hip-knee-ankle angle (HKA), mechanical lateral distal femur angle (mLDFA), mechanical medial proximal tibia angle (mMPTA), mechanical axis deviation (MAD), anatomic mechanic axis deviation (AMA) and joint line convergence angle (JLCA)]. CPAK and functional phenotype classifications were performed and all measurements were analysed for gender, age, and body mass index (BMI) within these subgroups. RESULTS: Varus alignment was more common in men (m: 2008, 68.5%; f: 2953, 50.8%) while neutral (m: 578, 19.7%; f: 1357, 23.4%) and valgus (m: 345, 11.8%; f: 1498, 25.8%) alignment was more common in women. The most common morphotypes according to CPAK classification were CPAK Type I (2454; 28.1%), Type II (2383; 27.3%), and Type III (1830; 20.9%). An apex proximal joint line (CPAK Type VII, VIII and IX) was only found in 1.3% of all cases (n = 121). In men, CPAK Type I (1136; 38.8%) and CPAK Type II (799; 27.3%) were the most common types and women were spread more equally between CPAK Type I (1318; 22.7%), Type II (1584; 27.3%) and Type III (1494; 25.7%) (p < 0.001). The most common combination of femur and tibia types was NEUmLDFA0°,NEUmMPTA0° (m: 514, 17.5%; f: 1004, 17.3%), but men showed femoral varus more often. Patients with a higher BMI showed a significantly lower age at surgery (R2 = 0.09, p < 0.001). There were significant differences between men and women for all radiographic parameters (p < 0.001). CONCLUSION: Distribution in knee morphology with gender-specific differences highlights the wide range in osteoarthritic knees, characterized by CPAK and phenotype classification and may influence future surgical planning. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Femenino , Inteligencia Artificial , Estudios Retrospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Extremidad Inferior , Tibia/diagnóstico por imagen , Tibia/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Fenotipo
10.
Sci Rep ; 13(1): 8504, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-37231033

RESUMEN

Artificial-intelligence (AI) allows large-scale analyses of long-leg-radiographs (LLRs). We used this technology to derive an update for the classical regression formulae by Trotter and Gleser, which are frequently used to infer stature based on long-bone measurements. We analyzed calibrated, standing LLRs from 4200 participants taken between 2015 and 2020. Automated landmark placement was conducted using the AI-algorithm LAMA™ and the measurements were used to determine femoral, tibial and total leg-length. Linear regression equations were subsequently derived for stature estimation. The estimated regression equations have a shallower slope and larger intercept in males and females (Femur-male: slope = 2.08, intercept = 77.49; Femur-female: slope = 1.9, intercept = 79.81) compared to the formulae previously derived by Trotter and Gleser 1952 (Femur-male: slope = 2.38, intercept = 61.41; Femur-female: slope = 2.47, intercept = 54.13) and Trotter and Gleser 1958 (Femur-male: slope = 2.32, intercept = 65.53). All long-bone measurements showed a high correlation (r ≥ 0.76) with stature. The linear equations we derived tended to overestimate stature in short persons and underestimate stature in tall persons. The differences in slopes and intercepts from those published by Trotter and Gleser (1952, 1958) may result from an ongoing secular increase in stature. Our study illustrates that AI-algorithms are a promising new tool enabling large-scale measurements.


Asunto(s)
Inteligencia Artificial , Estatura , Humanos , Masculino , Femenino , Pierna , Tibia/diagnóstico por imagen , Tibia/anatomía & histología , Fémur/diagnóstico por imagen , Fémur/anatomía & histología , Antropología Forense
11.
Int Orthop ; 47(4): 945-953, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36799971

RESUMEN

PURPOSE: Despite advances of three-dimensional imaging pelvic radiographs remain the cornerstone in the evaluation of the hip joint. However, large inter- and intra-rater variabilities were reported due to subjective landmark setting. Artificial intelligence (AI)-powered software applications could improve the reproducibility of pelvic radiograph evaluation by providing standardized measurements. The aim of this study was to evaluate the reliability and agreement of a newly developed AI algorithm for the evaluation of pelvic radiographs. METHODS: Three-hundred pelvic radiographs from 280 patients with different degrees of acetabular coverage and osteoarthritis (Tönnis Grade 0 to 3) were evaluated. Reliability and agreement between manual measurements and the outputs of the AI software were assessed for the lateral-center-edge (LCE) angle, neck-shaft angle, sharp angle, acetabular index, as well as the femoral head extrusion index. RESULTS: The AI software provided reliable results in 94.3% (283/300). The ICC values ranged between 0.73 for the Acetabular Index to 0.80 for the LCE Angle. Agreement between readers and AI outputs, given by the standard error of measurement (SEM), was good for hips with normal coverage (LCE-SEM: 3.4°) and no osteoarthritis (LCE-SEM: 3.3°) and worse for hips with undercoverage (LCE-SEM: 5.2°) or severe osteoarthritis (LCE-SEM: 5.1°). CONCLUSION: AI-powered applications are a reliable alternative to manual evaluation of pelvic radiographs. While being accurate for patients with normal acetabular coverage and mild signs of osteoarthritis, it needs improvement in the evaluation of patients with hip dysplasia and severe osteoarthritis.


Asunto(s)
Pinzamiento Femoroacetabular , Osteoartritis , Humanos , Reproducibilidad de los Resultados , Inteligencia Artificial , Articulación de la Cadera/diagnóstico por imagen , Acetábulo , Programas Informáticos , Estudios Retrospectivos
12.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1462-1469, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36509937

RESUMEN

PURPOSE: Unexpected-positive-intraoperative-cultures (UPIC) are common in presumed aseptic revision-total-knee-arthroplasties (rTKA). However, the clinical significance is not entirely clear. In contrast, in some presumably septic rTKA, identification of an underlying pathogen was not possible, so-called unexpected-negative-intraoperative-cultures (UNIC). The purpose of this study was to evaluate the potential use of synovial alpha-defensin (AD) levels in these patients. METHODS: Synovial AD levels from 143 rTKAs were evaluated retrospectively from our prospectively maintained institutional periprostetic joint infection (PJI) biobank and database. The 2018-International Consensus Meeting (ICM) criteria was used to define the study groups. Samples from UPICs with a minimum of one positive intraoperative culture (ICM 2- ≥ 6) (n = 20) and UNIC's (ICM ≥ 6) (n = 14) were compared to 34 septic culture-positive samples (ICM ≥ 6) and 75 aseptic culture-negative (ICM 0-1). Moreover, AD-lateral-flow-assay (ADLF) and an enzyme-linked-immunosorbent-assay (ELISA) in detecting the presence of AD in native and centrifuged synovial fluid specimens was performed. Concentration of AD determined by ELISA and ADLF methods, as well as microbiological, and histopathological results, serum and synovial parameters along with demographic factors were analysed. RESULTS: AD was positive in 31/34 (91.2%) samples from the septic culture-positive group and in 14/14 (100%) samples in the UNIC group. All UPIC samples showed a negative AD result. Positive AD samples were highly associated with culture positive and histopathological results (p < 0.001). No high-virulent microorganisms (0/20) were present in the UPIC group, compared to infected-group (19/34; 55.9%). High virulent microorganisms showed a positive AD result in 89.5% (17/19) of the cases. Methicillin resistant Staphylococcus epidermis (MRSE) infections had significantly higher AD levels than with methicillin susceptible S. epidermdis (MSSE) (p = 0.003). ELISA and ADLF tests were positive with centrifuged (8/8) and native (8/8) synovial fluid. CONCLUSION: AD showed a solid diagnostic performance in infected and non-infected revisions, and it provided an additional value in the diagnosis of UPIC and UNIC associated to rTKAs. Pathogen virulence as well as antibiotic resistance pattern may have an effect on AD levels. Centrifugation of synovial fluid had no influence on ADLF results.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infección Hospitalaria , Staphylococcus aureus Resistente a Meticilina , Infecciones Relacionadas con Prótesis , alfa-Defensinas , Humanos , Sensibilidad y Especificidad , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Líquido Sinovial/química , Biomarcadores/análisis
13.
Spine J ; 22(12): 1934-1943, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35853535

RESUMEN

BACKGROUND CONTEXT: In severe cases of postoperative spinal implant infections (PSII) multiple revision surgeries may be needed. Little is known if changes in the microbiological spectrum and antibiotic resistance pattern occur between revision surgeries. PURPOSE: Analysis of the microbiological spectrum and antibiotic resistance pattern in patients with multiple revision surgeries for the treatment of PSII STUDY DESIGN: Retrospective database analysis. PATIENT SAMPLE: Between 01/2011 and 12/2018, 103 patients underwent 248 revision surgeries for the treatment of PSII. Twenty patients (19.4%) who underwent multiple revision surgeries for PSII were included in this study. OUTCOME MEASURES: Microbiological spectrum, antibiotic resistance pattern. METHODS: A retrospective analysis of a prospectively maintained single center spine infection database was performed with a minimum follow-up of 3 years. Overall, 20 patients (six male/14 female) underwent 82 revisions for PSII (median 3; range 2-12). There were 55 of 82 (67.1%) procedures with a positive microbiological result. Microbiological analysis was performed on tissue and implant sonication fluid. Changes in microbial spectrum and antibiotic resistance pattern between surgeries were evaluated using Chi-Square and Fisher's exact test. RESULTS: In total, 74 microorganisms (83.3% gram-positive; 10.8% gram-negative) were identified. The most common microorganisms were Staphylococcus epidermidis (18.9%) and Cutibacterium acnes (18.9%). All S. epidermidis identified were methicillin-resistant (MRSE). Overall, there were 15 of 55 (27.3%) polymicrobial infections. The microbiological spectrum changed in 57.1% (20/35) between the revision stages over the entire PSII period. In 42.9% (15/35) the microorganism persisted between the revision surgeries stages. Overall, changes of the antibiotic resistance pattern were seen in 17.4% (8/46) of the detected microorganisms, comparing index revision and all subsequent re-revisions. Moreover, higher resistance rates were found for moxifloxacin and for ciprofloxacin at first re-revision surgery compared with index PSII revision. Resistances against vancomycin increased from 4.5% (1/23) at index PSII revision to 7.7% (2/26) at first re-revision surgery. CONCLUSIONS: Changes of the microbiological spectrum and the resistance pattern can occur in patients with severe PSII who require multiple revision surgeries. It is important to consider these findings in the antimicrobial treatment of PSII. The microbiological analysis of intraoperative tissue samples should be performed at every revision procedure for PSII.


Asunto(s)
Infecciones Relacionadas con Prótesis , Humanos , Masculino , Femenino , Reoperación/efectos adversos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Columna Vertebral/cirugía , Farmacorresistencia Microbiana
14.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2538-2547, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35819465

RESUMEN

PURPOSE: The purpose of this study was to evaluate the reliability of a newly developed AI-algorithm for the evaluation of long leg radiographs (LLR) after total knee arthroplasties (TKA). METHODS: In the validation cohort 200 calibrated LLRs of eight different common unconstrained and constrained knee systems were analysed. Accuracy and reproducibility of the AI-algorithm were compared to manual reads regarding the hip-knee-ankle (HKA) as well as femoral (FCA) and tibial component (TCA) angles. In the evaluation cohort all institutional LLRs with TKAs in 2018 (n = 1312) were evaluated to assess the algorithms' ability of handling large data sets. Intraclass correlation (ICC) coefficient and mean absolute deviation (sMAD) were calculated to assess conformity between the AI software and manual reads. RESULTS: Validation cohort: The AI-software was reproducible on 96% and reliable on 92.1% of LLRs with an output and showed excellent reliability in all measured angles (ICC > 0.97) compared to manual measurements. Excellent results were found for primary unconstrained TKAs. In constrained TKAs landmark setting on the femoral and tibial component failed in 12.5% of LLRs (n = 9). Evaluation cohort: Mean measurements for all postoperative TKAs (n = 1240) were 0.2° varus ± 2.5° (HKA), 89.3° ± 1.9° (FCA), and 89.1° ± 1.6° (TCA). Mean measurements on preoperative revision TKAs (n = 74) were 1.6 varus ± 6.4° (HKA), 90.5° ± 3.1° (FCA), and 88.9° ± 4.1° (TCA). CONCLUSIONS: AI-powered applications are reliable for automated analysis of lower limb alignment on LLRs with TKAs. They are capable of handling large data sets and could, therefore, lead to more standardized and efficient postoperative quality controls. LEVEL OF EVIDENCE: Diagnostic Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Inteligencia Artificial , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Pierna , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Reproducibilidad de los Resultados , Estudios Retrospectivos
15.
Anthropol Anz ; 79(2): 229-243, 2022 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-34761798

RESUMEN

Hip dysplasia (DDH) as well as femoroacetabular impingement (FAI) are common causes of hip pain in young adults and lead to premature osteoarthritis (OA). However, not all patients with radiographic features of DDH or FAI develop symptoms and degenerative changes, which indicates that various factors play a role in the disease process. Here we use a diamond concept to illustrate anatomical factors that play a role in the pathomechanism of symptomatic DDH and FAI. This concept may help clinicians in the diagnosis of hip pain in young adults. For DDH, the following factors are included: (1) acetabular and (2) femoral morphology, (3) pelvic shape and geometry, (4) spinopelvic alignment and (5) soft tissue properties. For FAI, the following factors are included: (1) intraarticular acetabular and (2) intraarticular femoral morphology, (3) extraarticular pelvic and (4) extraarticular femoral morphology, (5) spinopelvic alignment and (6) soft tissue properties. Knowledge of these factors can help to identify an adequate treatment. Surgical treatment options include (1) extraarticular acetabular, (2) extraarticular femoral, (3) intraarticular acetabular and (4) intraarticular femoral procedures. Further research is warranted on the specific role and the interaction of the parameters presented in the diamond concept in the disease process of hip joint degeneration.


Asunto(s)
Pinzamiento Femoroacetabular , Luxación de la Cadera , Acetábulo/diagnóstico por imagen , Pinzamiento Femoroacetabular/diagnóstico por imagen , Fémur/diagnóstico por imagen , Humanos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA