Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arrhythm ; 40(2): 306-316, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586839

RESUMEN

Background: Catheter ablation (CA) for premature ventricular contractions (PVCs) restores cardiac and renal functions in patients with reduced left ventricular ejection fraction (LVEF); however, its effects on preserved EF remain unelucidated. Methods: The study cohort comprised 246 patients with a PVC burden of >10% on Holter electrocardiography. Using propensity matching, we compared the changes in B-type natriuretic peptide (BNP) levels and estimated glomerular filtration rate (eGFR) in patients who underwent CA or did not. Results: Postoperative BNP levels were decreased significantly in the CA group, regardless of the degree of LVEF, whereas there was no change in those of the non-CA group. Among patients who underwent CA, BNP levels decreased from 44.1 to 33.0 pg/mL in those with LVEF ≥50% (p = .002) and from 141.0 to 87.9 pg/mL in those with LVEF <50% (p < .001). Regarding eGFR, postoperative eGFR was significantly improved in the CA group of patients with LVEF ≥50% (from 71.4 to 74.7 mL/min/1.73 m2, p = .006), whereas it decreased in the non-CA group. A similar trend was observed in the group with a reduced LVEF. Adjusted for propensity score matching, there was a significant decrease in the BNP level and recovery of eGFR after CA in patients with LVEF >50%. Conclusions: This study showed that CA for frequent PVCs decreases BNP levels and increases eGFR even in patients with preserved LVEF.

2.
J Cardiovasc Electrophysiol ; 34(9): 1869-1877, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37529869

RESUMEN

BACKGROUND: Since the local impedance (LI) of the ablation catheter reflects tissue characteristics, the efficacy of higher power (HP) compared to lower power (LP) in LI-guided ablation may differ from other index-guided ablations. OBJECTIVE: This study aimed to assess the efficacy of HP ablation in LI-guided ablation of atrial fibrillation (AF). METHODS: A prospective observational study was conducted, enrolling patients undergoing de novo ablation for AF. Pulmonary vein isolation was performed using point-by-point ablation with a RHYTHMIA HDxTM Mapping System and an open-irrigated ablation catheter with mini-electrodes (IntellaNav MIFI OI). Ablation was stopped when the LI drop reached 30 ohms, three seconds after the LI plateaued, or when ablation time reached 30 s. To balance the baseline differences, a unique method was used in which the power was changed between HP (45 W to anterior wall/40 W to posterior wall) and LP (35 W/30 W) alternately for each adjacent point. RESULTS: A total of 551 ablations in 10 patients were analyzed (HP, n = 276; LP, n = 275). The maximum LI drop was significantly larger (HP: 28.3 ± 5.4 vs. LP: 24.8 ± 6.3 ohm), and the time to minimum LI was significantly shorter (HP: 15.0 ± 6.3 vs. LP: 19.3 ± 6.6 s) in the HP setting. The unipolar electrogram analysis of three patients revealed that the electrogram indicating transmural lesion formation was observed more frequently in the HP setting. CONCLUSION: In LI-guided ablation, the HP could achieve a larger LI drop and shorter time to minimum LI, which may result in more transmural lesion formation compared to a LP setting.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Impedancia Eléctrica , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrodos , Resultado del Tratamiento
3.
J Arrhythm ; 39(1): 10-17, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36733332

RESUMEN

Background: Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate whether the angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation. Methods: We retrospectively enrolled 93 consecutive patients (52.7% male, age 82.4 ± 9.4 years), who received Micra implantation from September 2017 to June 2020 at our institution. After deployment and before the pull and hold test, the angle of the visible tines to the body of the pacemaker was measured using the RAO view of the fluoroscopy image. The engagement of the tines was then confirmed with the pull and hold test. Results: A total of 326 tines were analyzed. The angle of the engaged tines was significantly lower than the non-engaged tines (9.2 degrees [4.0-14.0] vs. 16.6 degrees [14.2-18.8], p < .0001). All tines with angles <10 degrees were engaged. In higher angles, engagement could not be predicted. Conclusion: A low angle of the tines before the pull and hold test can predict engagement of the tines in Micra leadless pacemaker implantation. The tines which are already open after deployment may be presumed that they are engaged.

4.
Intern Med ; 62(2): 275-279, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-35705278

RESUMEN

We herein report a case of pulmonary veno-occlusive disease (PVOD) induced by allo-hematopoietic stem cell transplantation (HSCT) in a 48-year-old man who was diagnosed with acute myeloid leukemia. Five months after transplantation, he developed dyspnea and was diagnosed with pulmonary hypertension based on right heart catheterization. Although he received treatment with pulmonary vasodilators, diuretics, and corticosteroids, his pulmonary artery pressure did not decrease, and his pulmonary edema worsened. Based on the clinical course, hypoxemia, diffusion impairment, and computed tomography findings, the patient was diagnosed with HSCT-related PVOD. Critical attention should be paid to dyspnea after HSCT for the early diagnosis of PVOD.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Leucemia Mieloide Aguda , Enfermedad Veno-Oclusiva Pulmonar , Masculino , Humanos , Persona de Mediana Edad , Enfermedad Veno-Oclusiva Pulmonar/diagnóstico por imagen , Enfermedad Veno-Oclusiva Pulmonar/etiología , Enfermedad Veno-Oclusiva Pulmonar/terapia , Pulmón , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Disnea , Leucemia Mieloide Aguda/terapia
5.
J Am Heart Assoc ; 11(24): e025803, 2022 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-36515231

RESUMEN

Background The prognostic role of BNP (B-type natriuretic peptide) in patients with cardiac sarcoidosis without evident heart failure is unknown. Methods and Results This is a post hoc analysis of ILLUMINATE-CS (Illustration of the Management and Prognosis of Japanese Patients With Cardiac Sarcoidosis), a multicenter, retrospective, and observational study that evaluated the clinical characteristics and prognosis of cardiac sarcoidosis. We analyzed patients with cardiac sarcoidosis without evident heart failure at the time of diagnosis. The association between baseline BNP levels and prognosis was investigated. The primary end point was the combined end point of all-cause death, heart failure hospitalization, and fatal ventricular arrhythmia. In total, 238 patients (61.0±11.1 years, 37% men) were analyzed, and 61 primary end points were observed during a median follow-up period of 3.0 (interquartile range, 1.7-5.8) years. Patients with high BNP (BNP above the median value of BNP) were older and had a lower renal function and left ventricular ejection fraction than those with low BNP values. Kaplan-Meier curve analysis indicated that high BNP levels were significantly associated with a high incidence of primary end points (log-rank P=0.004), and this association was retained even in multivariable Cox regression (hazard ratio, 2.06 [95% CI, 1.19-3.55]; P=0.010). Log-transformed BNP as a continuous variable was associated with the primary end point (hazard ratio, 2.12 [95% CI, 1.31-3.43]; P=0.002). Conclusions High baseline BNP level was an independent predictor of future adverse events in patients with cardiac sarcoidosis without heart failure at the time of diagnosis. Registration URL: https://www.umin.ac.jp/english/; Unique Identifier: UMIN-CTR: UMIN000034974.


Asunto(s)
Insuficiencia Cardíaca , Miocarditis , Sarcoidosis , Femenino , Humanos , Masculino , Biomarcadores , Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico , Pronóstico , Estudios Retrospectivos , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico , Sarcoidosis/epidemiología , Volumen Sistólico , Función Ventricular Izquierda , Persona de Mediana Edad , Anciano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...