Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
Am J Cardiol ; 214: 47-54, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38215815

RESUMEN

Sodium-glucose cotransporter-2 inhibitors (SGLT2is) are widely used in cardiology and are effective in treating acute coronary syndrome (ACS). Their effects on unstable plaque in patients with ACS remains unclear. This study aimed to examine the effectiveness of SGLT2is in coronary plaque based on optical coherence tomography (OCT) images and the prognosis of ACS with type 2 diabetes mellitus. This retrospective study included 109 patients in the total cohort and 29 patients in the OCT cohort. Based on SGLT2i administration after ACS, the total cohort was categorized into non-SGLT2i (n = 69) and SGLT2i (n = 40) groups. The OCT cohort had 15 and 14 patients in the non-SGLT2i and SGLT2i groups, respectively. The OCT images of unstable plaque were analyzed in nonstented lesions during ACS catheterization and at the 6-month follow-up. The total cohort was assessed after 1 year for major adverse cardiovascular events, including all-cause mortality, revascularization, cerebrovascular disease, and heart failure hospitalization. SGLT2is improved unstable lesions with a significantly thicker fibrous cap (48 ± 15 µm vs 26 ± 24 µm, p = 0.005), reduced lipid arc (-29 ± 12° vs -18 ± 14°, p = 0.028), higher % decrease in total lipid arc (-35 ± 13% vs -19 ± 18%, p = 0.01), and lower major adverse cardiovascular event incidence (log-rank p = 0.023, hazard ratio 4.72 [1.08 to 20.63]) and revascularization rate (adjusted hazard ratio 6.77 [1.08 to 42.52]) than the non-SGLT2i group. In conclusion, SGLT2is can improve the markers of plaque stability and may improve the prognosis in patients with type 2 diabetes mellitus.


Asunto(s)
Síndrome Coronario Agudo , Diabetes Mellitus Tipo 2 , Placa Aterosclerótica , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/tratamiento farmacológico , Síndrome Coronario Agudo/epidemiología , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Estudios Retrospectivos , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/tratamiento farmacológico , Glucosa , Lípidos , Sodio
3.
Circ J ; 88(4): 462-471, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38030300

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS), but despite estimates of life expectancy after TAVI being essential in heart team discussion, these data are scarce. Therefore, the current study sought to assess long-term survival and its trends in relation to chronological age, surgical risk, and treatment period.Methods and Results: We included 2,414 consecutive patients who underwent TAVI for severe symptomatic AS between 2008 and 2021 at 2 international centers. For the analysis, long-term survival was evaluated according to age, surgical risk, and treatment period categorized into 3 groups, respectively. The longest follow-up was 13.5 years. Overall survival was 67.6% at 5 years and 26.9% at 10 years. Younger patients, lower surgical risk, and later treatment period showed better survival (log-rank P<0.001, respectively). In the multivariate analysis, age <75years, lower surgical risk, and later time period were significantly associated with better survival. The incidence of paravalvular leakage ≥moderate, red blood cell transfusion, and acute kidney injury were independently associated with increasing risk of 5-year death. CONCLUSIONS: In a real-world registry, survival was substantial following TAVI, especially in younger and lower surgical-risk patients, with improving outcomes over time. This should be considered in heart team discussions of life-long management for AS patients after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Sistema de Registros
4.
Am J Cardiol ; 213: 151-160, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38103766

RESUMEN

Preexisting right bundle branch block (RBBB) is the strongest predictor for permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI). However, the risk assessment for new PPI and effective procedural strategy for preventing new PPI in patients with preexisting RBBB are still unclear. This study stratified the new PPI risk after TAVI and investigated the impact of implantation strategy in a preexisting RBBB cohort. We analyzed 237 patients with preexisting RBBB who underwent TAVI. The primary endpoint was the incidence of new PPI. Multivariate analyses investigating predictors for new PPI were performed. The overall PPI rate was 33.3%. Significant baseline predictors for new PPI were combination of RBBB, left anterior or posterior fascicular block, and first-degree atrioventricular block (odds ratio [OR] 2.55, 95% confidence interval [CI] 1.09 to 5.04), high calcium volume of noncoronary cusp (OR 2.08, 95% CI 1.05 to 4.10), and membranous septum (MS) length <2 mm (OR 2.02, 95% CI 1.09 to 3.75) in the univariate analysis and MS length <2 mm (OR 2.25, 95% CI 1.06 to 4.82) in the multivariate analysis. On the multivariate analysis including procedural variables, predilatation (OR 2.41, 95% CI 1.01 to 5.83), self-expanding valves (Corevalve, Evolut R, and Evolut Pro/Pro+; Medtronic Inc., Minneapolis, Minnesota) or mechanical expanding valves (Lotus/Lotus Edge; Boston Scientifics, Marlborough, Massachusetts) (OR 3.00, 95% CI 1.31 to 6.91), and implantation depth > MS length (OR 4.27, 95% CI 1.81 to 10.08) were significantly associated with new PPI. The incidence of new PPI increased according to the number of baseline predictors (0: 20.9%, 1: 34.3%, and ≥2: 52.0%) and procedural predictors (0: 3.7%, 1: 20.9%, 2: 40.5%, and 3: 60.0%). New PPI risk in a preexisting RBBB subset could be stratified by baseline factors. Device selection and implantation strategy considering MS length could prevent new PPI even in these high-risk population.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Marcapaso Artificial/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Medición de Riesgo , Factores de Riesgo , Válvula Aórtica/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos
5.
J Arrhythm ; 39(6): 894-900, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38045461

RESUMEN

Background: Previous studies have revealed the risk factors for femoral pseudoaneurysms (FPA). Most data on FPA are based on coronary and peripheral interventions, with limited studies focusing on atrial fibrillation (AF) ablation. However, patient backgrounds, anticoagulation regimens, and vascular access methods differ. In addition, a standard for managing FPA after AF ablation remains elusive due to the difficult nature of achieving thrombosis in pseudoaneurysms. Methods: This single-center, retrospective, observational study included 2805 consecutive patients who underwent AF ablation between January 2016 and December 2021. All patients underwent femoral artery and vein punctures. Puncture sites were checked 1 day post-procedure. Results: A total of 23 FPA patients were identified during the study period. Multivariate logistic regression analysis showed that hypertension (odds ratio 4.66, 95% confidence interval: 1.38-15.71; p = .0032) and warfarin use (odds ratio 3.83, 95% confidence interval: 1.40-10.45; p = .021) were significantly associated with the occurrence of FPA. The compression success rate was low (22%). There were nine and six patients in the endovascular treatment (EVT) and ultrasound-guided thrombin injection (UGTI) groups, respectively. The success rates were 100% and 84% in the EVT and UGTI groups, respectively. The length of hospital stay after FPA treatment was 2.1 days in the EVT group and 1.3 days in the thrombin group. Conclusion: We must be careful about post-procedural FPA, especially for hypertension and warfarin-using patients. Treatment of pseudoaneurysms with anticoagulants is unlikely to achieve hemostasis, and an early switch to invasive treatments, such as EVT, should be considered.

6.
Am J Cardiol ; 207: 140-149, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37738784

RESUMEN

The optimal percent oversizing (%OS) using the SAPIEN3 Ultra (S3U) weighing the incidence of paravalvular regurgitation (PVR) ≥ mild against the risk of conduction disturbance (CD) is not known. This study sought to define an optimal extent of the annulus area %OS suitable for transcatheter aortic valve implantation with the S3U compared with the SAPIEN3 (S3). A total of 350 patients with the S3U were compared with 606 patients with the S3. Patients were categorized depending on the degree of %OS. PVR ≥ mild was observed in 8.9% of patients with the S3U and in 21.8% of those with the S3 (p <0.001). The S3U demonstrated a sustainably lower incidence of PVR ≥ mild than the S3 in any extent of %OS. There was an inverse proportional relation between the extent of %OS and frequency of PVR ≥ mild in the S3, whereas the S3U group provided little change. The incidences of PVR ≥ mild were steady >5%OS in the S3 (5% to 10%OS: 13.3%, and >10%OS: 12.1%) and >0%OS in the S3U (0% to 5%OS: 5.9%, 5% to 10%OS: 6.0%, and >10%OS: 6.1%). An increasing %OS was independently associated with the occurrence of CD (<0%OS: 9.8%, 0% to 5%OS: 13.1%, 5% to 10%OS: 16.6%, and >10%OS: 19.2%, p = 0.012). The incidence of PVR ≥ mild and/or CD was the lowest (10.1%) in the 0% to 5%OS in patients with the S3U. In conclusion, the HomoSAPIEN2 study suggests that the S3U tolerates a lesser degree of %OS for mitigating PVR ≥ mild than the S3. Minimal %OS, ranging from 0% to 5%, may be optimal for the S3U with balancing the risk of PVR and CD. Trial Identifier: UMIN000040413/URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000046115.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Am J Cardiol ; 203: 17-22, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37478637

RESUMEN

Membranous septum (MS) length, in conjunction with implantation depth (ID), is known as a determinant of conduction disturbance (CD) after transcatheter aortic valve implantation (TAVI). However, its impact might be dissimilar among valve types because each valve has a different platform. This study sought to investigate the different impacts of ID and MS length on the new-onset CD between ACURATE neo and SAPIEN 3. This study included patients without a previous permanent pacemaker implantation who underwent TAVI with ACURATE neo and SAPIEN 3 and divided them into 2 groups based on the ID according to MS length (deep and shallow implantation group). Deep implantation was defined as transcatheter heart valve implantation deeper than MS length. The primary endpoint was new-onset CD (new permanent pacemaker implantation or new-onset complete left bundle branch block). A total of 688 patients (deep implantation: n = 373, shallow implantation: n = 315) were identified as a study cohort. New-onset CD developed more frequently in the deep implantation group (16.6% vs 7.0%; p = 0.0001). Deep implantation was revealed as a predictor of new-onset CD. Moreover, deep implantation was significantly associated with new-onset CD after SAPIEN 3 implantation but not after ACURATE neo. Among patients with MS shorter than 2 mm, ACURATE neo was superior in terms of avoiding new-onset CD. In conclusion, the deep implantation was associated with new-onset CD after TAVI with SAPIEN 3 but not with ACURATE neo. These results may impact device selection in patients with a preexisting high risk of CD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Trastorno del Sistema de Conducción Cardíaco/complicaciones , Válvula Aórtica/cirugía , Diseño de Prótesis
8.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37489732

RESUMEN

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Sistema de Registros , Accidente Cerebrovascular/epidemiología
9.
CVIR Endovasc ; 6(1): 34, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37347446

RESUMEN

BACKGROUND: Although majority of cases with chronic total occlusion (CTO) in femoro-popliteal lesion were treated with antegrade approach only, some lesions require alternative approach due to its complexity. Bi-directional approach is useful on endovascular therapy (EVT) for CTO; however guidewire passage through the lesion is impossible in some challenging cases. The present case shows a successful re-entry technique utilizing two snare catheters from an antegrade and retrograde access site (double snare piecing technique). CASE PRESENTATION: A 79-year-old woman with right leg intermittent claudication (Rutherford category IV), who had undergone unsuccessful EVT for popliteal CTO, required another EVT for the worsening symptom. Following the failed conventional crossing technique (wire knuckle technique, intravascular-ultrasound-guided wiring, and controlled antegrade and retrograde subintimal tracking technique), two snare catheters were placed and the snare loops were pierced by a puncture needle percutaneously. After an 0.014 wire was inserted into the needle, the needle was withdrawn. The wire was pulled from the retrograde side and was externalized. Then, the antegrade snare catheter was pulled and externalized, to make the wire across the lesion. After that, a microcatheter was advanced along the externalized wire from the retrograde side and cross the lesion. The wire was replaced with a new wire, which completely created pull-through system. After the hemostasis by balloon inflation and lesion preparation, this procedure was completed with an endoluminal-covered stent and two inter-woven stents. The re-entry site was covered by the inter-woven stent. Her symptoms improved after the procedure, and the lesion has not developed restenosis at 2-years follow-up. CONCLUSIONS: This re-entry technique of puncturing two snare loops (double snare piercing technique) might be effective for achieving successful passage through challenging femoropopliteal CTO cases.

10.
JACC Cardiovasc Interv ; 16(10): 1192-1204, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225290

RESUMEN

BACKGROUND: Data regarding the impact of high transcatheter heart valve (THV) implantation on coronary access after transcatheter aortic valve replacement (TAVR) as assessed by postimplantation computed tomography (CT) are scarce. OBJECTIVES: The authors sought to assess the impact of high THV implantation on coronary access after TAVR. METHODS: We included 160 and 258 patients treated with Evolut R/PRO/PRO+ and SAPIEN 3 THVs, respectively. In the Evolut R/PRO/PRO+ group, the target implantation depth was 1 to 3 mm using the cusp overlap view with commissural alignment technique for the high implantation technique (HIT), whereas it was 3 to 5 mm using 3-cusp coplanar view for the conventional implantation technique (CIT). In the SAPIEN 3 group, the HIT employed the radiolucent line-guided implantation, whereas the central balloon marker-guided implantation was used for the CIT. Post-TAVR CT was performed to analyze coronary accessibility. RESULTS: HIT reduced the incidence of new conduction disturbances after TAVR for both THVs. In the Evolut R/PRO/PRO+ group, post-TAVR CT showed that the HIT group had a higher incidence of the interference of THV skirt (22.0% vs 9.1%; P = 0.03) and a lower incidence of the interference of THV commissural posts (26.0% vs 42.7%; P = 0.04) with access to 1 or both coronary ostia compared with the CIT group. These incidences were similar between the HIT and CIT groups in the SAPIEN 3 group (THV skirt: 0.9% vs 0.7%; P = 1.00; THV commissural tabs: 15.7% vs 15.3%; P = 0.93). In both THVs, CT-identified risk of sinus sequestration in TAVR-in-TAVR was significantly higher in the HIT group compared with the CIT group (Evolut R/PRO/PRO+ group: 64.0% vs 41.8%; P = 0.009; SAPIEN 3 group: 17.6% vs 5.3%; P = 0.002). CONCLUSIONS: High THV implantation substantially reduced conduction disturbances after TAVR. However, post-TAVR CT revealed that there is a risk for unfavorable future coronary access after TAVR and sinus sequestration in TAVR-in-TAVR. (Impact of High Implantation of Transcatheter Heart Valve during Transcatheter Aortic Valve Replacement on Future Coronary Access; UMIN000048336).


Asunto(s)
Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Tomografía Computarizada por Rayos X
12.
J Cardiol Cases ; 27(4): 196-198, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37012921

RESUMEN

Mucopolysaccharidoses (MPSs) are inherited metabolic diseases characterized by the deficiency of lysosomal enzymes and the accumulation of glycosaminoglycans in various organs, including the heart. In particular, aortic valve disease causes high morbidity and mortality rates, and sometimes requires surgical aortic valve replacement (SAVR) at a young age. Although transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) in surgical high-risk patients is a well-established treatment, there are few reports of TAVR in MPS and medium- and long-term outcomes are not known. We present a case of severe AS in a MPS patient with high risk for SAVR who was successfully treated with TAVR and has shown a fine medium-term result. A 40-year-old woman with MPS type I-HS (Hurler-Scheie syndrome) receiving enzyme replacement therapy as a systemic treatment had complained of syncope and worsening dyspnea, and she was diagnosed with severe AS. The patient had a history of temporary tracheotomy because of the difficulty of endotracheal intubation. Considering risk for general anesthesia, TAVR was performed under local anesthesia. She has improved symptoms for one-and-a-half years. TAVR for severe AS in MPS would be an alternative option for surgical high-risk patients and can demonstrate preferable medium-term outcomes combined with systemic therapies. Learning objective: Mucopolysaccharidoses (MPSs) are metabolic diseases affecting various organs. The MPS patients requiring surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) often have a high surgical risk. However, in MPS, transcatheter aortic valve replacement (TAVR) could be an alternative procedure to SAVR. We report a MPS patient treated with TAVR showing a preferable medium-term outcome. We suggest that TAVR for severe AS in MPS is an acceptable treatment option.

13.
Am J Cardiol ; 191: 14-22, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36623409

RESUMEN

The impact of mild paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) remains controversial. We evaluated the impact of mild PVR after TAVI on long-term clinical outcomes. We included patients who underwent TAVI for severe symptomatic aortic stenosis between December 2008 and June 2019 at 2 international centers and compared all-cause death between the group with mild PVR (group 1) and the group with none or trace PVR (group 2). PVR was categorized using a 3-class grading scheme, and patients with PVR ≧ moderate and those who were lost to follow-up were excluded. This retrospective analysis included 1,404 patients (mean age 81.7 ± 6.5 years, 58.0% women). Three hundred fifty eight patients (25.5%) were classified into group 1 and 1,046 patients (74.5%) into group 2. At baseline, group 1 was older and had a lower body mass index, worse co-morbidities, and more severe aortic stenosis. To account for these differences, propensity score matching was performed, resulting in 332 matched pairs. Within these matched groups, during a mean follow-up of 3.2 years, group 1 had a significantly lower survival rate at 5 years (group 1: 62.0% vs group 2: 68.0%, log-rank p = 0.029, hazard ratio: 1.41 [95% confidence interval: 1.04 to 1.91]). In the matched cohort, patients with mild PVR had a significant 1.4-fold increased risk of mortality at 5 years after TAVI compared with those with none or trace PVR. Further studies with more patients are needed to evaluate the impact of longer-term outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo
14.
Scand Cardiovasc J ; 57(1): 2161621, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-36587829

RESUMEN

Objectives. To compare long-term angina pectoris relief of successful versus failed percutaneous coronary intervention of chronic total occlusions (CTO PCI). Background. Previous studies demonstrate better short-term angina pectoris relief of CTO PCI than with optimal medical treatment (OMT), however, data on the long-term effects are lacking. Methods. 295 patients undergoing CTO PCI were analyzed retrospectively, with a follow-up evaluation of symptoms of angina pectoris and all-cause death one to four years after the intervention. The primary outcome was long-term relief of symptoms of angina pectoris. Secondary outcomes included a composite of major adverse cardiovascular events (MACE), including all-cause death, myocardial infarction, stroke, and later target vessel revascularization (TVR). At follow-up, patients were interviewed for symptoms of angina pectoris at 1, 6, 12, and 22 to 48 months after the intervention. Results. CTO PCI was successful in 225 (76%) patients and failed in 70 (24%) patients. Short-term (six months) relief of angina pectoris was observed in both groups, but only the successful CTO PCI group showed long-term relief. The Kaplan-Meier curves of all-cause death did not differ between the groups (p = .715). The final follow-up was a mean (range) of 37 (25 to 44) months after the intervention in the successful CTO PCI group, and 33 (28 to 48) months in the failed CTO PCI group. Conclusions. Successful CTO PCI is associated with better long-term relief of symptoms of angina pectoris compared to failed CTO PCI.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Vasos Coronarios , Estudios Retrospectivos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/terapia , Enfermedad Crónica , Resultado del Tratamiento , Factores de Riesgo
15.
J Cardiol ; 81(2): 138-143, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36057484

RESUMEN

BACKGROUND: Discordance between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) occurs in approximately 20 % of cases. However, no studies have reported the discordance in patients with severe aortic stenosis (AS). We aimed to evaluate the diagnostic discordance between FFR and iFR in patients with severe AS. METHODS: We examined 140 consecutive patients with severe AS (164 intermediate coronary artery stenosis vessels). FFR and iFR were calculated in four quadrants based on threshold FFR and iFR values of ≤0.8 and ≤0.89, respectively (Group 1: iFR >0.89, FFR >0.80; Group 2: iFR ≤0.89, FFR >0.80; Group 3: iFR >0.89, FFR ≤0.80; and Group 4: iFR ≤0.89, FFR ≤0.80). Concordant groups were Groups 1 and 4, and discordant groups were Groups 2 and 3. Positive and negative discordant groups were Groups 3 and 2, respectively. RESULTS: The median (Q1, Q3) FFR and iFR were 0.84 (0.76, 0.88) and 0.85 (0.76, 0.91), respectively. Discordance was observed in 48 vessels (29.3 %). In the discordant group, negative discordance (Group 2: iFR ≤0.89 and FFR >0.80) was predominant (45 cases, 93.6 %). Multivariate analysis showed that the left anterior descending artery [odds ratio (OR), 3.88; 95 % confidence interval (CI): 1.54-9.79, p = 0.004] and peak velocity ≥5.0 m/s (OR, 3.21; 95%CI: 1.36-7.57, p = 0.008) were independently associated with negative discordance (FFR >0.8 and iFR ≤0.89). CONCLUSIONS: In patients with severe AS, discordance between FFR and iFR was predominantly negative and observed in 29.3 % of vessels. The left anterior descending artery and peak velocity ≥5.0 m/s were independently associated with negative discordance.


Asunto(s)
Estenosis de la Válvula Aórtica , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Angiografía Coronaria , Estudios Retrospectivos , Cateterismo Cardíaco , Valor Predictivo de las Pruebas , Estenosis Coronaria/diagnóstico , Vasos Coronarios , Estenosis de la Válvula Aórtica/diagnóstico , Índice de Severidad de la Enfermedad
16.
Cardiovasc Revasc Med ; 47: 62-69, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36114124

RESUMEN

BACKGROUND: Comparisons of hemodynamic results between ACURATE Neo and ACURATE Neo 2, which have updated outer sealing skirts, are limited. This retrospective study aimed to demonstrate the differences in hemodynamic outcomes between the two transcatheter heart valves (THVs). METHODS: We included 449 patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with either ACURATE Neo2 (n = 100) or ACURATE Neo (n = 348) between January 2016 and November 2021. The primary endpoint was the incidence of moderate or severe paravalvular leakage (PVL). The mean aortic pressure gradient (APG), peak aortic velocity (AV), and early clinical outcomes were assessed as secondary outcomes. RESULTS: In the propensity-score matching comparison (94 pairs), there were no significant differences in the incidence of moderate or severe PVL (4.3 % in Neo2 group vs. 8.5 % in Neo group, p = 0.233), and peak AV and mean APG were significantly higher in Neo2 group (Peak AV: 2.1 ± 0.4 vs. 1.9 ± 0.5 m/s, p = 0.003; mean APG: 10.6 ± 4.8 vs. 9.0 ± 6.1 mmHg, p = 0.045). In the multivariate logistic regression analysis, the THV type (ACURATE Neo2) was not an independent predictor of moderate or severe PVL. CONCLUSION: The incidence of moderate or severe PVL did not significantly differ between TAVR with ACURATE Neo2 and ACURATE Neo; however, it was numerically lower in ACURATE Neo2. In contrast, the Neo2 group had a higher residual mean APG and peak AV. A larger study with long-term follow-up is warranted to assess the clinical relevance of these findings.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Hemodinámica
17.
J Invasive Cardiol ; 34(8): E627-E632, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35920732

RESUMEN

OBJECTIVES: Although a distal radial artery (DRA) approach has recently been used in patients undergoing cardiac catheterization, no studies have so far investigated the safety and feasibility of DRA in patients undergoing hemodialysis (HD). We aimed to investigate the incidence of conventional radial artery (CRA) occlusion and puncture site complications after DRA puncture in patients undergoing HD. METHODS: We retrospectively analyzed the data of 117 consecutive patients with HD who underwent coronary angiography or percutaneous coronary intervention via a DRA approach at our institution from September 2017 to December 2019. The primary endpoint was the incidence of CRA occlusion after DRA puncture, as assessed via vascular ultrasonography. Secondary endpoints included difficulty achieving hemostasis, DRA occlusion, aneurysm, arteriovenous shunt, and acute ischemia. RESULTS: The DRA puncture was successful in 106 patients (success rate: 90.5%). Because 21 patients lacked postprocedural vascular ultrasonography data, the primary endpoint was evaluated in 85 patients. CRA occlusion occurred in three patients (3.5%) following DRA puncture. DRA occlusion and aneurysm occurred in five patients (5.9%) and one patient (1.2%), respectively. CONCLUSIONS: Catheterization through DRA is feasible in patients undergoing HD, with a clinically acceptable incidence of CRA and complications.


Asunto(s)
Arteriopatías Oclusivas , Cateterismo Periférico , Intervención Coronaria Percutánea , Arteriopatías Oclusivas/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Periférico/efectos adversos , Angiografía Coronaria/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Arteria Radial , Diálisis Renal/efectos adversos , Estudios Retrospectivos
18.
Am J Cardiol ; 180: 116-123, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35933223

RESUMEN

Despite the development of device technology and operators' experience, access site vascular complications (VCs) remain one of the major concerns after transcatheter aortic valve implantation (TAVI). MANTA (Teleflex, Wayne, Pennsylvania) is a large-bore vascular closure device (VCD) with promising incidence of VC. Previously, we demonstrated that the ultrasound-guided MANTA (US-MANTA) technique further improved the outcomes compared with conventional MANTA (C-MANTA) without ultrasound guidance. The present study was established to prove the effectiveness of the technique in a larger population. In this study, we included 1,150 patients (335 patients with C-MANTA and 815 with US-MANTA) who received MANTA after TAVI from April 2017 to September 2021. The primary endpoint was MANTA-related VC. Overall VC, VCD failure, and bleeding complications were also assessed based on the Valve Academic Research Consortium 3 criteria. MANTA-related VC occurred in 12.5% in the C-MANTA group and 6.8% in the US-MANTA group (p = 0.001). VCD failure rate were 7.5% and 3.9%, respectively (p = 0.012). Valve Academic Research Consortium 3 major and minor VC were more frequent in C-MANTA group (major: 7.8% vs 4.4%, p = 0.023; minor: 8.1% vs 4.4%, p = 0.022). Multivariate analysis revealed US-MANTA as the negative predictor of MANTA-related VC (odds ratio 0.57, 95% confidence interval 0.36 to 0.89, p = 0.013). However, subgroup analysis showed the efficacy of the US-MANTA technique was limited to the patients without severely calcified puncture site (Pinteraction = 0.048). In conclusion, the US-MANTA technique was an effective strategy to reduce VC after transfemoral TAVI compared with C-MANTA.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Humanos , Resultado del Tratamiento , Ultrasonografía Intervencional
19.
Am J Cardiol ; 176: 96-104, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35643552

RESUMEN

Recent studies showed the favorable outcomes of transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve (BAV) stenosis. However, data on the relation between BAV morphology and optimal transcatheter heart valve (THV) selection are limited. This study sought to evaluate the determinants of device performance in patients with BAV who underwent TAVI. Consecutive patients with BAV who underwent TAVI with the SAPIEN 3 from multicenters were evaluated. Outcomes were the incidence and predictors of device failure. Device failure was defined as peak aortic velocity >3.0 m/s, mean pressure gradient >20 mm Hg, moderate or severe paravalvular leakage and/or procedure mortality. A total of 187 patients with BAV were identified, aged 77 years, and 38.0% were women. A total of 37 patients (19.8%) were treated with 23-mm valve, 58 (31.0%) with 26-mm valve, and 92 (49.2%) with 29-mm valve. Predischarge echocardiogram demonstrated 37 patients (19.8%) with device failure. BAV with excessive leaflet calcification plus calcified raphe (EC-BAV) (OR 16.7, 95% CI 1.99 to 39.6) and smaller THV (OR 4.41, 95% CI 1.43 to 13.6) were independently associated with increased risk of device failure. In addition, 4.0%, 5.1%, and 11.1% of device failures were observed in patients without EC-BAV who underwent TAVI with 23-, 26- and 29-mm THV (p = 0.47), respectively, and 91.7%, 31.6% and 23.2% in those with EC-BAV, respectively (p <0.001). In conclusion, EC-BAV morphology was the major determinant of a device failure after TAVI. Moreover, TAVI in patients with EC-BAV requiring small SAPIEN 3 could be challenging. Further data on device and treatment selection in patients with BAV are still warranted.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Falla de Equipo , Femenino , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
20.
JACC Case Rep ; 4(7): 443-448, 2022 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-35693895

RESUMEN

Superior vena cava laceration has been reported as a catastrophic complication that requires immediate surgical intervention during transvenous lead extraction. Hereby, we present 2 cases of pseudoaneurysm formation at the superior vena cava after transvenous lead extraction, which were successfully managed without invasive treatment. (Level of Difficulty: Advanced.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...