1.
Opt Express ; 32(7): 10801-10828, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38570945

RESUMEN

The phase problem is a well known ill-posed reconstruction problem of coherent lens-less microscopic imaging, where only the squared magnitude of a complex wavefront is measured by a detector while the phase information of the wave field is lost. To retrieve the lost information, common algorithms rely either on multiple data acquisitions under varying measurement conditions or on the application of strong constraints such as a spatial support. In X-ray near-field holography, however, these methods are rendered impractical in the setting of time sensitive in situ and operando measurements. In this paper, we will forego the spatial support constraint and propose a projected gradient descent (PGD) based reconstruction scheme in combination with proper preprocessing and regularization that significantly reduces artifacts for refractive reconstructions from only a single acquired hologram without a spatial support constraint. We demonstrate the feasibility and robustness of our approach on different data sets obtained at the nano imaging endstation of P05 at PETRA III (DESY, Hamburg) operated by Helmholtz-Zentrum Hereon.

2.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557882

RESUMEN

In magnetic particle imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter, and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer called an inductive coupling network are used. Our primary objectives are to achieve floating potentials to ensure patient safety while attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition for a symmetric transmit-receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed, and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and method-of-moment based simulations.

3.
Phys Med Biol ; 68(17)2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37609892

RESUMEN

Objective.Magnetic particle imaging (MPI) is capable of high temporal resolution measurements of the spatial distribution of magnetic nanoparticles and therefore well suited for perfusion imaging, which is an important tool in medical diagnosis. Perfusion imaging in MPI usually requires a fresh bolus of tracer material to capture the key signal dynamics. Here, we propose a method to decouple the imaging sequence from the injection of additional tracer material, without further increasing the administered iron dose in the body with each image.Approach.A bolus of physiological saline solution without any particles (negative contrast) diminishes the steady-state concentration of a long-circulating tracer during passage. This depression in the measured concentration contributes to the required contrast dynamics. The presence of a long-circulating tracer is therefore a prerequisite to obtain the negative contrast. As a quantitative tracer based imaging method, the signal is linear in the tracer concentration for any location that contains nanoparticles and zero in the surrounding tissue which does not provide any intrinsic signal. After tracer injection, the concentration over time (positive contrast) can be utilized to calculate dynamic diagnostic parameters like perfusion parameters in vessels and organs. Every acquired perfusion image thus requires a new bolus of tracer with a sufficiently large iron dose to be visible above the background.Main results.Perfusion parameters are calculated based on the time response of the proposed negative bolus and compared to a positive bolus. Results from phantom experiments show that normalized signals from positive and negative boli are concurrent and deviations of calculated perfusion maps are low.Significance.Our method opens up the possibility to increase the total monitoring time of a future patient by utilizing a positive-negative contrast sequence, while minimizing the iron dose per acquired image.


Asunto(s)
Medios de Contraste , Solución Salina , Humanos , Hierro , Imagen de Perfusión , Fenómenos Magnéticos
4.
IEEE Trans Med Imaging ; 40(12): 3568-3579, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34152980

RESUMEN

Background signals are a primary source of artifacts in magnetic particle imaging and limit the sensitivity of the method since background signals are often not precisely known and vary over time. The state-of-the art method for handling background signals uses one or several background calibration measurements with an empty scanner bore and subtracts a linear combination of these background measurements from the actual particle measurement. This approach yields satisfying results in case that the background measurements are taken in close proximity to the particle measurement and when the background signal drifts linearly. In this work, we propose a joint estimation of particle distribution and background signal based on a dictionary that is capable of representing typical background signals. Reconstruction is performed frame-by-frame with minimal assumptions on the temporal evolution of background signals. Thus, even non-linear temporal evolution of the latter can be captured. Using a singular-value decomposition, the dictionary is derived from a large number of background calibration scans that do not need to be recorded in close proximity to the particle measurement. The dictionary is sufficiently expressive and represented by its principle components. The proposed joint estimation of particle distribution and background signal is expressed as a linear Tikhonov-regularized least squares problem, which can be efficiently solved. In phantom experiments it is shown that the method strongly suppresses background artifacts and even allows to estimate and remove the direct feed-through of the excitation field.


Asunto(s)
Algoritmos , Artefactos , Análisis de los Mínimos Cuadrados , Fenómenos Magnéticos , Imagen por Resonancia Magnética , Fantasmas de Imagen
5.
Phys Med Biol ; 66(9)2021 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-33765669

RESUMEN

Magnetic particle imaging (MPI) is a tomographic imaging technique for determining the spatial distribution of superparamagnetic nanoparticles. Current MPI systems are capable of imaging iron masses over a wide dynamic range of more than four orders of magnitude. In theory, this range could be further increased using adaptive amplifiers, which prevent signal clipping. While this applies to a single sample, the dynamic range is severely limited if several samples with different concentrations or strongly inhomogeneous particle distributions are considered. One scenario that occurs quite frequently in pre-clinical applications is that a highly concentrated tracer bolus in the vascular system 'shadows' nearby organs with lower effective tracer concentrations. The root cause of the problem is the ill-posedness of the MPI imaging operator, which requires regularization for stable reconstruction. In this work, we introduce a simple two-step algorithm that increases the dynamic range by a factor of four. Furthermore, the algorithm enables spatially adaptive regularization, i.e. highly concentrated signals can be reconstructed with maximum spatial resolution, while low concentrated signals are strongly regularized to prevent noise amplification.


Asunto(s)
Algoritmos , Nanopartículas de Magnetita , Tomografía
6.
IEEE Trans Med Imaging ; 39(11): 3548-3558, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32746103

RESUMEN

Magnetic particle imaging is a tracer based imaging technique to determine the spatial distribution of superparamagnetic iron oxide nanoparticles with a high spatial and temporal resolution. Due to physiological constraints, the imaging volume is restricted in size and larger volumes are covered by shifting object and imaging volume relative to each other. This results in reduced temporal resolution, which can lead to motion artifacts when imaging dynamic tracer distributions. A common source of such dynamic distributions are cardiac and respiratory motion in in-vivo experiments, which are in good approximation periodic. We present a raw data processing technique that combines data snippets into virtual frames corresponding to a specific state of the dynamic motion. The technique is evaluated on the basis of measurement data obtained from a rotational phantom at two different rotational frequencies. These frequencies are determined from the raw data without reconstruction and without an additional navigator signal. The reconstructed images give reasonable representations of the rotational phantom frozen in several different states of motion while motion artifacts are suppressed.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador , Fenómenos Magnéticos , Imagen por Resonancia Magnética , Movimiento (Física) , Fantasmas de Imagen
7.
Cardiovasc Intervent Radiol ; 43(2): 322-330, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31529176

RESUMEN

PURPOSE: Magnetic particle imaging (MPI) is a novel tomographic radiation-free imaging technique that combines high spatial resolution and real-time capabilities, making it a promising tool to guide vascular interventions. Immediate availability of 3D image data is a major advantage over the presently used digital subtraction angiography (DSA), but new methods for real-time image analysis and visualization are also required to take full advantage of the MPI properties. This laboratory study illustrates respective techniques by means of three different patient-specific 3D vascular flow models. MATERIAL AND METHODS: The selected models corresponded to typical anatomical intervention sites. Routine patient cases and image data were selected, relevant vascular territories segmented, 3D models generated and then 3D-printed. Printed models were used to perform case-specific MPI imaging. The resulting MPI images, direct volume rendering (DVR)-based fast 3D visualization options, and their suitability to advance vascular interventions were evaluated and compared to conventional DSA. RESULTS: The experiments illustrated the feasibility and potential to enhance image interpretation during interventions by using MPI real-time volumetric imaging and problem-tailored DVR-based fast (approximately 30 frames/s) 3D visualization options. These options included automated viewpoint selection and cutaway views. The image enhancement potential is especially relevant for complex geometries (e.g., in the presence of superposed vessels). CONCLUSION: The unique features of the as-yet preclinical imaging modality MPI render it promising for guidance of vascular interventions. Advanced fast DVR could help to fulfill this promise by intuitive visualization of the 3D intervention scene in real time.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Nanopartículas de Magnetita , Radiología Intervencionista/métodos , Tomografía/métodos , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/cirugía , Estudios de Factibilidad , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/cirugía , Humanos , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/cirugía , Modelos Biológicos
8.
IEEE Trans Med Imaging ; 39(5): 1347-1358, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31647426

RESUMEN

The tomographic imaging method magnetic particle imaging (MPI) requires a multi-patch approach for capturing large field of views. This approach consists of a continuous or stepwise spatial shift of a small sub-volume of only few cubic centimeters size, which is scanned using one or multiple excitation fields in the kHz range. Under the assumption of ideal magnetic fields, the MPI system matrix is shift invariant and in turn a single matrix suffices for image reconstruction significantly reducing the calibration time and reconstruction effort. For large field imperfections, however, the method can lead to severe image artifacts. In the present work we generalize the efficient multi-patch reconstruction to work under non-ideal field conditions, where shift invariance holds only approximately for small shifts of the sub-volume. Patches are clustered based on a magnetic-field-based metric such that in each cluster the shift invariance holds in good approximation. The total number of clusters is the main parameter of our method and allows to trade off calibration time and image artifacts. The magnetic-field-based metric allows to perform the clustering without prior knowledge of the system matrices. The developed reconstruction algorithm is evaluated on a multi-patch measurement sequence with 15 patches, where efficient multi-patch reconstruction with a single calibration measurement leads to strong image artifacts. Analysis reveals that calibration measurements can be decreased from 15 to 11 with no visible image artifacts. A further reduction to 9 is possible with only slight degradation in image quality.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía , Algoritmos , Artefactos , Campos Magnéticos , Fantasmas de Imagen
9.
Phys Med Biol ; 64(7): 074001, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30870817

RESUMEN

Magnetic particle imaging (MPI) is an imaging modality that detects the response of a distribution of magnetic nanoparticle tracers to alternating magnetic fields. There has recently been exploration into multi-contrast MPI, in which the signal from different tracer materials or environments is separately reconstructed, resulting in multi-channel images that could enable temperature or viscosity quantification. In this work, we apply a multi-contrast reconstruction technique to discriminate between nanoparticle tracers of different core sizes. Three nanoparticle types with core diameters of 21.9 nm, 25.3 nm and 27.7 nm were each imaged at 21 different locations within the scanner field of view. Multi-channel images were reconstructed for each sample and location, with each channel corresponding to one of the three core sizes. For each image, signal weight vectors were calculated, which were then used to classify each image by core size. With a block averaging length of 10 000, the median signal-to-noise ratio was 40 or higher for all three sample types, and a correct prediction rate of 96.7% was achieved, indicating that core size can effectively be predicted using signal weight vector classification with close to 100% accuracy while retaining high MPI image quality. The discrimination of the core size was reliable even when multiple samples of different core sizes were placed in the measuring field.


Asunto(s)
Algoritmos , Medios de Contraste , Nanopartículas de Magnetita/química , Imagen Molecular/métodos , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador , Imagen Molecular/instrumentación
10.
Med Phys ; 46(3): 1371-1383, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30657597

RESUMEN

PURPOSE: Intravascular optical coherence tomography (IVOCT) is a catheter-based image modality allowing for high-resolution imaging of vessels. It is based on a fast sequential acquisition of A-scans with an axial spatial resolution in the range of 5-10 µm, that is, one order of magnitude higher than in conventional methods like intravascular ultrasound or computed tomography angiography. However, position and orientation of the catheter in patient coordinates cannot be obtained from the IVOCT measurements alone. Hence, the pose of the catheter needs to be established to correctly reconstruct the three-dimensional vessel shape. Magnetic particle imaging (MPI) is a three-dimensional tomographic, tracer-based, and radiation-free image modality providing high temporal resolution with unlimited penetration depth. Volumetric MPI images are angiographic and hence suitable to complement IVOCT as a comodality. We study simultaneous bimodal IVOCT MPI imaging with the goal of estimating the IVOCT pullback path based on the 3D MPI data. METHODS: We present a setup to study and evaluate simultaneous IVOCT and MPI image acquisition of differently shaped vessel phantoms. First, the influence of the MPI tracer concentration on the optical properties required for IVOCT is analyzed. Second, using a concentration allowing for simultaneous imaging, IVOCT and MPI image data are acquired sequentially and simultaneously. Third, the luminal centerline is established from the MPI image volumes and used to estimate the catheter pullback trajectory for IVOCT image reconstruction. The image volumes are compared to the known shape of the phantoms. RESULTS: We were able to identify a suitable MPI tracer concentration of 2.5 mmol/L with negligible influence on the IVOCT signal. The pullback trajectory estimated from MPI agrees well with the centerline of the phantoms. Its mean absolute error ranges from 0.27 to 0.28 mm and from 0.25 mm to 0.28 mm for sequential and simultaneous measurements, respectively. Likewise, reconstructing the shape of the vessel phantoms works well with mean absolute errors for the diameter ranging from 0.11 to 0.21 mm and from 0.06 to 0.14 mm for sequential and simultaneous measurements, respectively. CONCLUSIONS: Magnetic particle imaging can be used in combination with IVOCT to estimate the catheter trajectory and the vessel shape with high precision and without ionizing radiation.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Imagen Molecular/métodos , Fantasmas de Imagen , Tomografía de Coherencia Óptica/métodos , Animales , Ratones
11.
IEEE Trans Med Imaging ; 38(4): 932-944, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30334751

RESUMEN

Due to peripheral nerve stimulation, the magnetic particle imaging (MPI) method is limited in the maximum applicable excitation-field amplitude. This in turn leads to a limitation of the size of the covered field of view (FoV) to few millimeters. In order to still capture a larger FoV, MPI is capable to rapidly acquire volumes in a multi-patch fashion. To this end, the small excitation volume is shifted through space using the magnetic focus fields. Recently, it has been shown that the individual patches are preferably reconstructed in a joint fashion by solving a single linear system of equations taking the coupling between individual patches into account. While this improves the image quality, it is computationally and memory demanding since the size of the linear system increases in the best case quadratically with the number of patches. In this paper, we will develop a reconstruction algorithm for MPI multi-patch data exploiting the sparsity of the joint system matrix. A highly efficient implicit matrix format allows for rapid on-the-fly calculations of linear algebra operations involving the system matrix. Using this approach, the computational effort can be reduced to a linear dependence on the number of used patches. The algorithm is validated on 3-D multi-patch phantom data sets and shown to reconstruct large data sets with 15 patches in less than 22 s.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Nanopartículas de Magnetita/química , Tomografía/métodos , Algoritmos , Magnetismo , Fantasmas de Imagen
12.
J Med Imaging (Bellingham) ; 5(4): 046002, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30525063

RESUMEN

Magnetic particle imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI, the size of the field of view (FoV) scales with the strengths of the applied magnetic fields. In clinical applications, those strengths are limited by peripheral nerve stimulation, specific absorption rates, and the requirement to acquire images of high spatial resolution. Therefore, the size of the FoV is usually a few cubic centimeters. To bypass this limitation, additional focus fields and/or external object movements can be applied. The latter approach is investigated. An object is moved through the scanner bore one step at a time, whereas the MPI scanner continuously acquires data from its static FoV. Using a 3-D phantom and dynamic 3-D in vivo data, it is shown that the data from such a moving table experiment can be jointly reconstructed after reordering the data with respect to the stepwise object shifts and heart beat phases.