Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Prosthodont ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594949

RESUMEN

PURPOSE: To introduce a novel design for scan body accessory parts that are reusable, easy to attach and detach without permanent change of the scan body, and can be used with different inter-implant distances to enhance the accuracy of complete arch implant scans. MATERIALS AND METHODS: A maxillary polymethylmethacrylate (PMMA) model with a soft tissue replica was fabricated with four implant analogs located at tooth positions 17, 13, 22, and 27 with 18, 25, and 30 mm inter-implant distances. Four scan bodies (SBs) were attached to the implants. The model was scanned with a laboratory scanner to be used as a reference scan. A total of 40 scans were made with the same intraoral scanner and they were divided equally into two groups. Group A: Complete arch implant scans without scan body accessories (n = 20), and Group B: Complete arch implant scans with scan body accessories (n = 20). Intraoral scans were exported and superimposed on the reference scan using reverse engineering inspection software to be evaluated for 3D deviations, angular deviations, and linear deviations. Statistical analysis was performed with student t-test and analysis of variance (ANOVA) with repeated measures followed by post hoc adjusted Bonferroni test. The level of significance was set at P = 0.05. RESULTS: The scan body accessories decreased both the 3D and linear deviations, with a statistically significant difference at SB4 for the 3D deviation (P = 0.043) and the linear inter-implant discrepancies between SB1-SB2 and SB3-SB4 (P = 0.029 and < 0.001), respectively. However, there was no statistically significant difference in angular deviation between the study groups. Implant positions had significant differences within each group. CONCLUSIONS:  A significant improvement in the accuracy of the complete arch implant digital impression was achieved by using the scan body accessories, particularly in reducing the 3D and linear deviations at the most distant implant positions.

2.
Res Sq ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38558983

RESUMEN

African American (AA) kidney transplant recipients (KTRs) have poor outcomes, which may in-part be due to tacrolimus (TAC) sub-optimal immunosuppression. We previously determined the common genetic regulators of TAC pharmacokinetics in AAs which were CYP3A5 *3, *6, and *7. To identify low-frequency variants that impact TAC pharmacokinetics, we used extreme phenotype sampling and compared individuals with extreme high (n=58) and low (n=60) TAC troughs (N=515 AA KTRs). Targeted next generation sequencing was conducted in these two groups. Median TAC troughs in the high group were 7.7 ng/ml compared with 6.3 ng/ml in the low group, despite lower daily doses of 5 versus 12mg, respectively. Of 34,542 identified variants across 99 genes, 1,406 variants were suggestively associated with TAC troughs in univariate models (p-value <0.05), however none were significant after multiple testing correction. We suggest future studies investigate additional sources of TAC pharmacokinetic variability such as drug-drug-gene interactions and pharmacomicrobiome.

3.
Transplantation ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38361239

RESUMEN

The human microbiome is associated with human health and disease. Exogenous compounds, including pharmaceutical products, are also known to be affected by the microbiome, and this discovery has led to the field of pharmacomicobiomics. The microbiome can also alter drug pharmacokinetics and pharmacodynamics, possibly resulting in side effects, toxicities, and unanticipated disease response. Microbiome-mediated effects are referred to as drug-microbiome interactions (DMI). Rapid advances in the field of pharmacomicrobiomics have been driven by the availability of efficient bacterial genome sequencing methods and new computational and bioinformatics tools. The success of fecal microbiota transplantation for recurrent Clostridioides difficile has fueled enthusiasm and research in the field. This review focuses on the pharmacomicrobiome in transplantation. Alterations in the microbiome in transplant recipients are well documented, largely because of prophylactic antibiotic use, and the potential for DMI is high. There is evidence that the gut microbiome may alter the pharmacokinetic disposition of tacrolimus and result in microbiome-specific tacrolimus metabolites. The gut microbiome also impacts the enterohepatic recirculation of mycophenolate, resulting in substantial changes in pharmacokinetic disposition and systemic exposure. The mechanisms of these DMI and the specific bacteria or communities of bacteria are under investigation. There are little or no human DMI data for cyclosporine A, corticosteroids, and sirolimus. The available evidence in transplantation is limited and driven by small studies of heterogeneous designs. Larger clinical studies are needed, but the potential for future clinical application of the pharmacomicrobiome in avoiding poor outcomes is high.

4.
J Prosthodont ; 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38288528

RESUMEN

PURPOSE: Attempts have been made to decontaminate the implant surface by using diode lasers. However, the parameters that provide efficient decontamination without altering the topography or surface characteristics of titanium implants are still unclear. The aim of the present study was to evaluate the effect of altering the power of diode laser (940 nm) application on the hydrophilicity, surface topography, and chemical composition of sandblasted, large grit, acid-etched (SLA) treated titanium alloy implant surface. MATERIALS AND METHODS: Thirty-six SLA-treated titanium discs (Dentis Co., Ltd.) were used in this study. The hydrophilicity of all discs was measured by using a contact angle goniometer (190 CA; Rame-hart Co, Ltd). Discs were randomly divided into four groups (n = 9 each) based on the power of the diode laser used. Group I (control, no lasing group), group II: treated with 1 W power, group III: 2 W power, and group IV: 3 W power. The chemical composition of the SLA discs was evaluated by using energy dispersive x-ray spectroscopy (EDX) before laser application. Hydrophilicity was reevaluated after the application of laser irradiation. The surface topography of all discs was examined. Changes in the chemical composition of the titanium discs were investigated following the lasing procedure. Morphometric analysis of the surface area (µm2 ) of the indentations created following laser application was also evaluated. Data were collected and the Shapiro-Wilk test of normality was used. Comparisons between the four study groups were done by using the Kruskal-Wallis test, while that to evaluate the morphometric analysis of the surface area was done by using One-way ANOVA (P < 0.05). RESULTS: The average contact angle of the drop of distilled water to the SLA discs significantly decreased after laser treatment (P < 0.05). The largest contact angle was measured in the control group, followed by the 1 W group, and the 2 W group. The smallest angle was measured in the 3 W group. Considerable surface alterations such as melting and flattening were observed on examination of the surface topography of the 3 W group followed by the 2 W group. The least changes were observed in association with the 1 W group in comparison to the control group. The EDX analysis showed the appearance of peaks of the oxygen and carbon elements after the lasing procedure with the highest percentage in the 3 W group. The average of the surface area of the created indentations significantly increased with increasing the power of the diode laser used (P < 0.05). CONCLUSIONS: The application of diode laser (940 nm) with 2 W and 3 W powers significantly altered the hydrophilicity, the surface topography, and the chemical composition of titanium discs. Diode laser (940 nm) with 1 W power can be safely used on SLA titanium implant surfaces with no damaging effect on the surface topography or hydrophilicity.

5.
J Prosthodont ; 33(3): 301-304, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37422858

RESUMEN

Various techniques have been described for the rehabilitation of ocular defects with ocular prostheses to restore lost anatomical structures and correct cosmetic defects. This article describes a technique for optimizing the position of an iris disk over a custom-made ocular prosthesis, by using eyeglasses with customized graph paper pattern lenses. It presents a simplified method that will be useful for people with ocular defects in remote and distant service areas with limited resources.


Asunto(s)
Ojo Artificial , Iris , Humanos , Diseño de Prótesis , Iris/cirugía , Cara
6.
Nat Commun ; 14(1): 8279, 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38092762

RESUMEN

Electric mobility is fundamental to combat climate change and attaining the United Nations Sustainable Development Goals (SDG-11). However, electric mobility necessitates a seamless integration between power and transportation systems, as the resiliency of both systems is becoming far more interdependent. Here, we focus on disruption to Battery Electric Bus (BEB) transit system charging infrastructure and offer a resilient BEB transit system planning model. The proposed model optimizes the BEB system costs while ensuring the system's robustness against simultaneous charging station failures. In our case study, a single charging station failure would lead to up to 34.03% service reduction, and two simultaneous failures would reduce the service by up to 58.18%. Our proposed two-stage robust model addresses this issue with a relatively small added cost (3.26% and 8.12% higher than the base model). This cost enables uninterrupted BEB system operation during disruption, ensuring personal mobility, social interaction, and economic productivity.

7.
BMC Oral Health ; 23(1): 967, 2023 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-38053146

RESUMEN

BACKGROUND: In-vitro data from a clinically well-known lithium disilicate ceramic reference was used to assess the expected performance of resin-based materials in implant dentistry. The purpose of the study was to compare the bond strength and marginal adaptation of nano-ceramic hybrid composite crowns cemented to stock cement-retained abutments to lithium disilicate crowns. METHODS: Twenty abutment analogs were embedded into auto-polymerizing acrylic resin blocks. The blocks were divided into 2 groups according to the restorative crown material. The 2 groups were divided as follows: Resin nano-ceramic group and lithium disilicate group. Abutment analogs in both groups were scanned using a laboratory scanner, and the restorations were designed, manufactured, and cemented with resin cement over the corresponding group. All samples were tested for marginal adaptation and bond strength after storage for 24 hours at 37 °C in 100% humidity. Data were collected, tabulated, and statistically analysed using the appropriate tests. Normality was checked using Shapiro Wilk test and Q-Q plots. Data were normally distributed. Variables were presented using mean, 95% Confidence Interval (CI) and standard deviation in addition to median and Inter Quartile Range (IQR). Differences between groups regarding debonding forces was assessed using independent t test. Two Way ANOVA was performed to assess the effect of material and bonding on marginal gap. All tests were two tailed and p value was set at < 0.05. RESULTS: Marginal gap and debonding force values were significantly different according to the type of material used (P < .05). Resin nano-ceramic crowns presented lower marginal gap values before (20.80 ± 8.87 µm) and after (52.11 ± 22.92 µm) bonding than lithium disilicate crowns. The debonding force value for resin nano-ceramic crowns (284.30 ± 26.44 N) was significantly higher than that for lithium disilicate crowns (253.30 ± 33.26 N). Adhesive failure mode was detected in all the specimens in both groups. CONCLUSIONS: The type of material used for implant-supported cement-retained crowns had a statistically significant effect on marginal adaptation and bond strength. Resin nano-ceramic implant-supported cement-retained crowns had better marginal adaptation and higher bond strength than those manufactured using lithium disilicate.


Asunto(s)
Coronas , Cementos Dentales , Humanos , Cementos de Ionómero Vítreo , Materiales Dentales , Cerámica , Cementos de Resina , Diseño Asistido por Computadora , Ensayo de Materiales
8.
BMC Oral Health ; 23(1): 613, 2023 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-37649061

RESUMEN

BACKGROUND: Straight preparable abutments and titanium bases (ti-base) can be used to support single-unit screw-retained lithium disilicate implant-supported restorations. The choice between using both abutments depends on many factors. The purpose of this in vitro study was to compare the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to straight preparable abutments and ti-bases. METHODS: Twenty laboratory implant analogs (Straumann Bone Level; Straumann AG) were randomly divided into 2 groups (n = 10 each) according to the type of the abutment used. Preparable abutment group and ti-base group. Lithium disilicate crowns were used to restore the specimens. All specimens were subjected to thermocycling (from 5 to 55 °C for 2000 cycles) followed by cyclic loading (120 000 cycles). The vertical marginal gap between the abutment finish line and the most apical part of the crown was measured in (µm) by using a stereomicroscope after cementation and after thermocycling and cyclic loading. A spectrophotometer was used to evaluate the masking ability of the specimens after cementation. The load required to fracture the crowns was measured in Newtons (N) by using a universal testing machine after thermocycling and cyclic loading. The Shapiro-Wilk test of normality was used. The appropriate statistical test was used. RESULTS: Regarding the masking ability, the color difference (∆E) showed no statistically significant difference between the ti-base group (2.6 ± 0.2) and the preparable abutment group (2.6 ± 0.3) (P = .888). The average of the microgap values (µm) was greater in ti-basegroup after cementation (13.9 ± 9.2) than preparable group (7.63 ± 1.78) with no statistically significant difference between the 2 groups (P = .49). After cyclic loading and thermocycling, the average microgap values (µm) was significantly greater in the ti base group (21.3 ± 7.4) than in preparable group (13.3 ± 1.5) (P = .02). The load required to fracture the specimens was greater in the preparable group (1671.5 ± 143.8) than in the ti-base group (1550.2 ± 157.5) with no statistically significant difference between the 2 groups (P = .089). CONCLUSION: The abutments used in the present study did not compromise the masking ability of the screw-retained lithium disilicate implant supported crowns. Moreover, the crowns cemented to preparable abutments had better marginal adaptation and higher fracture resistance when compared to those cemented to ti-bases. CLINICAL IMPLICATIONS: Straight preparable abutments are considered as an alternative to the ti-bases when restoring single screw-retained lithium disilicate implant-supported crowns with comparable fracture resistance, marginal adaptation, and masking ability.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Tornillos Óseos , Coronas
9.
J Prosthet Dent ; 130(2): 252.e1-252.e8, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37468368

RESUMEN

STATEMENT OF PROBLEM: Digital scanning of different prosthodontic materials is commonplace in contemporary practice. However, the scannability of prosthodontic materials has not been thoroughly investigated. PURPOSE: The purpose of this in vitro study was to evaluate the scanning accuracy and measure the unscanned area in a preset time limit of commonly used framework materials. MATERIAL AND METHODS: A mandibular acrylic resin reference dental typodont with 3 teeth, with the central one prepared for a complete coverage crown, was digitized by using a desktop scanner. A complete coverage crown was generated in standard tessellation language (STL) format. Three groups were created from the digital design according to the crown material: milled polyetheretherketone (PEEK), milled airborne-particle abraded titanium, and milled polymethylmethacrylate (PMMA). They were scanned with the desktop scanner to be used as reference files for each group. The intraoral scanner Medit i700 was used to digitize each specimen 10 times (n=10). Using a nonmetrology grade software program, the deviations between the test STL file of the intraoral scanner and the reference STL file of the desktop scanner were assessed by using the RMS values. The unscanned surface area in a preset time limit of 6 seconds (scannability) was assessed. Groups were compared by using 1-way ANOVA followed by the Tukey post hoc test with Bonferroni correction when the results were significant. All tests were 2-tailed (α=0.05). RESULTS: Regarding deviation analysis, RMS discrepancies were computed, and significant differences in trueness were found (P<.001) among the 3 studied groups. The titanium group had the highest trueness followed by the PEEK and PMMA groups, which were statistically similar (P>.05). Precision differed significantly among the 3 studied groups (P<.001). PEEK was the most precisely scanned material followed by titanium, and the PMMA group had the least precision. Regarding scannability, there were overall significant differences (P<.001). Titanium was the most scannable, followed by PEEK and then PMMA. CONCLUSIONS: Airborne-particle abraded titanium had better trueness and scannability than PEEK and PMMA. However, PEEK was the most precisely scanned material.


Asunto(s)
Diseño Asistido por Computadora , Polimetil Metacrilato , Prostodoncia , Titanio , Técnica de Impresión Dental , Modelos Dentales , Imagenología Tridimensional
10.
BMC Oral Health ; 23(1): 458, 2023 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-37420233

RESUMEN

BACKGROUND: The aim of this study was to assess the impact of abutments with angled screw access channel on the retention of zirconia crowns. METHODS: Seven implant replicas were inserted in epoxy resin blocks. Fourteen zirconia crowns for central incisor tooth were digitally fabricated and cemented to titanium bases (Ti-bases) with resin cement. Titanium bases were categorized into 2 groups (n = 7). Control group (Group STA) included straight screw access channel abutments. Study group (Group ASC) included angled screw access channel abutments. Following aging (5 °C-55 °C, 60 s; 250,000 cycles, 100 N, 1.67 Hz), the pull-off forces (N) were recorded by using retention test (1 mm/min). Types of failure were defined as (Type 1; Adhesive failure when luting agent predominantly remained on the Ti-base surface (> 90%); Type 2; Cohesive failure when luting agent remained on both Ti-base and crown surfaces; and Type 3; Adhesive failure when luting agent predominantly remained on the crown (> 90%). Statistical analysis was conducted by using (IBM SPSS version 28). Normality was checked by using Shapiro Wilk test and Q-Q plots. Independent t-test was then used to analogize the groups. RESULTS: Mean ± standard deviation of retention force records ranged from 1731.57 (63.68) N (group STA) to 1032.29 (89.82) N (group ASC), and there was a statistically significant variation between the 2 groups (P < .05). Failure modes were Type 2 for group STA and Type 3 for group ASC. CONCLUSIONS: The retention of zirconia crowns to abutments with a straight screw access channel is significantly higher than abutments with angled screw access channel.


Asunto(s)
Cementos Dentales , Titanio , Humanos , Coronas , Tornillos Óseos , Ensayo de Materiales , Análisis del Estrés Dental
11.
Lupus ; 32(7): 842-854, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37161972

RESUMEN

Few studies tackled the long-term effect of pregnancy on lupus nephritis (LNs); thus, the study aimed to explore the long-term impact of pregnancy on renal outcomes in Egyptian patients with LN. Group I patients included females who had their first pregnancy after LN onset with ≥5 years elapsing after delivery; group II patients included females who had never got pregnant for ≥7 years after LN onset. Data were retrospectively collected at baseline (T0) and the last visit (Tlast). The study included 43 patients in group I and 39 patients in group II. The comparisons between the two groups regarding the characteristics at Tlast showed no significant difference regarding the serum creatinine, estimated glomerular filtration rate (eGFR), renal component of SLICC/ACR Damage Index (SDI) as well as the rate of renal flares, new-onset chronic kidney disease (CKD), progressed CKD and end-stage renal disease. Multivariate regression analysis revealed that systemic hypertension and renal flares were predictors of new-onset/progressed CKD (p = 0.019, OR [95% CI] = 4 [1.3-13]; and 0.022, 13.8 [1.5-128.8], respectively) while pregnancy was not (p = 0.363). Paired comparisons between T0 and Tlast characteristics within each group revealed significant increment of serum creatinine, renal SDI and CKD prevalence; as well as decrement of eGFR in group I (p = 0.004, <0.001, 0.001 and <0.001, respectively) and group II (p = 0.006, <0.001, 0.004 and 0.002, respectively). In conclusion, pregnancy, per se, does not affect the long-term renal outcome in LN patients; however, it is rather dependent on the existence of baseline renal damage and the development of renal flares.


Asunto(s)
Lupus Eritematoso Sistémico , Nefritis Lúpica , Insuficiencia Renal Crónica , Humanos , Femenino , Nefritis Lúpica/complicaciones , Nefritis Lúpica/epidemiología , Estudios de Casos y Controles , Estudios Retrospectivos , Creatinina , Egipto/epidemiología , Factores de Riesgo , Riñón/fisiología
12.
BMC Oral Health ; 23(1): 300, 2023 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-37198623

RESUMEN

BACKGROUND: Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments. METHODS: Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0-10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman's rank correlation coefficient. RESULTS: The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman's rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. CONCLUSIONS: Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.


Asunto(s)
Implantes Dentales , Humanos , Cementos Dentales , Cementos de Ionómero Vítreo , Coronas , Titanio , Análisis del Estrés Dental , Prótesis Dental de Soporte Implantado , Ensayo de Materiales
13.
J Prosthet Dent ; 129(5): 777.e1-777.e7, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37029006

RESUMEN

STATEMENT OF PROBLEM: The accuracy of different virtual cement gap parameters in designing a single crown in a computer-aided design (CAD) software program is still unclear. PURPOSE: The purpose of this in vitro study was to evaluate and compare the virtual cement gap settings of 3 different CAD software programs used to design a single crown restoration. MATERIAL AND METHODS: Three different CAD software programs (exocad, Dental System, and B4D) were evaluated for designing single crowns with similar virtual cement gap settings. Three experimental groups were created based on the CAD software program used (n=10). Three-dimensional analysis software program was used to assess the virtual cement gap in the CAD restoration. The Shapiro-Wilk test of normality was used. Comparisons were carried out by using 1-way ANOVA and the Scheffé post hoc test (α=.05). RESULTS: The Dental System software program had the lowest statistical mean error values at both tooth margin (4.6 µm) and axial wall (1.5 µm), followed by B4D then exocad. At the occlusal surface, the lowest statistical mean error value of 5 µm was achieved by the Dental System followed by exocad then B4D. CONCLUSIONS: Accuracy of the virtual cement gap parameter in single crown design varies based on the CAD software used. The highest accuracy was attained by the Dental System software program at all tooth surfaces, followed by B4D at the tooth margin and axial wall and by exocad at the occlusal surface.


Asunto(s)
Adaptación Marginal Dental , Diseño de Prótesis Dental , Coronas , Cementos Dentales , Cementos de Ionómero Vítreo , Diseño Asistido por Computadora
14.
J Prosthet Dent ; 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36966102

RESUMEN

STATEMENT OF PROBLEM: Providing a definitive restoration with an emergence profile matching that of the contralateral or extracted tooth should result in an esthetic peri-implant soft tissue contour. Whether a custom healing abutment improves the outcome of a bio-copied definitive restoration compared with a stock abutment is unclear. PURPOSE: The purpose of this 1-year randomized clinical trial was to evaluate the peri-implant soft and hard tissues related to bio-esthetic single implant-supported restorations having a contralateral tooth-matching restorative emergence profile after peri-implant soft tissue conditioning with either custom or stock healing abutment for patients indicated for immediate implant placement. MATERIAL AND METHODS: Twenty-four participants indicated for immediate implant placement in the maxillary esthetic zone received bio-esthetic single implant-supported restorations after peri-implant soft tissue conditioning with either a custom healing abutment (n=12) or a stock healing abutment (n=12). The pink and white esthetic score (PES-WES) was evaluated 6 and 12 months after implant placement. Peri-implant bone changes were measured with cone beam computed tomography (CBCT) scans at the same intervals. RESULTS: The PES-WES showed significant difference between the 2 groups at 6 and 12 months. The CBCT scans did not show significant difference between the 2 groups. CONCLUSIONS: The use of the bio-esthetic concept for immediate single implant placement achieved successful esthetic restorations after conditioning the peri-implant tissues using either custom or stock healing abutments. However, the use of custom healing abutments was associated with higher PES-WES values in comparison with the use of stock healing abutments.

15.
J Prosthet Dent ; 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36813587

RESUMEN

STATEMENT OF PROBLEM: Straight preparable abutments provide an alternative to titanium bases (Ti-bases) for single-unit screw-retained implant-supported restorations. However, the debonding force between crowns with a screw access channel cemented to preparable abutments and Ti-bases of different designs and surface treatments is unclear. PURPOSE: The purpose of this in vitro study was to compare the debonding force of screw-retained lithium disilicate implant-supported crowns cemented to straight preparable abutments and Ti-bases of different designs and surface treatments. MATERIAL AND METHODS: Forty laboratory implant analogs (Straumann Bone Level) were embedded into epoxy resin blocks that were randomly divided into 4 groups (n=10 each) according to the abutment type used: CEREC group, Variobase group, airborne-particle abraded Variobase group, and airborne-particle abraded straight preparable abutment group. All specimens were restored with lithium disilicate crowns and cemented with resin cement to the corresponding abutments. They were thermocycled (from 5 to 55 °C for 2000 cycles) followed by cyclic loading (120 000 cycles). The tensile forces required to debond the crowns from the corresponding abutments were measured (N) by using a universal testing machine. The Shapiro-Wilk test of normality was used. Comparison between the study groups was done with 1-way ANOVA (α=.05). RESULTS: Tensile debonding force values were significantly different according to the type of abutment used (P<.05). The highest retentive force value was recorded in the straight preparable abutment group (928.1 ±222.2 N) followed by the airborne-particle abraded Variobase group (852.6 ±164.6 N), and the CEREC group (498.8 ±136.6 N); the lowest value was reported in the Variobase group (158.6 ±85.2 N). CONCLUSIONS: The retention of screw-retained lithium disilicate implant-supported crowns cemented to airborne-particle abraded straight preparable abutments is significantly higher than to non-surface treated Ti-bases and similar to airborne-particle abraded ones. Abrading abutments with 50-mm Al2O3 significantly increased the debonding force of the lithium disilicate crowns.

16.
PLoS One ; 18(1): e0278468, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36662779

RESUMEN

Accessibility indicators are widely used in transportation, urban and healthcare planning, among many other applications. These measures are weighted sums of reachable opportunities from a given origin, conditional on the cost of movement, and are estimates of the potential for spatial interaction. Over time, various proposals have been forwarded to improve their interpretability: one of those methodological additions have been the introduction of competition. In this paper we focus on competition, but first demonstrate how a widely used measure of accessibility with congestion fails to properly match the opportunity-seeking population. We then propose an alternative formulation of accessibility with competition, a measure we call spatial availability. This measure relies on proportional allocation balancing factors (friction of distance and population competition) that are equivalent to imposing a single constraint on conventional gravity-based accessibility. In other words, the proportional allocation of opportunities results in a spatially available opportunities value which is assigned to each origin that, when all origin values are summed, equals the total number of opportunities in the region. We also demonstrate how Two-Stage Floating Catchment Area (2SFCA) methods are equivalent to spatial availability and can be reconceptualized as singly-constrained accessibility. To illustrate the application of spatial availability and compare it to other relevant measures, we use data from the 2016 Transportation Tomorrow Survey of the Greater Golden Horseshoe area in southern Ontario, Canada. Spatial availability is an important contribution since it clarifies the interpretation of accessibility with competition and paves the way for future applications in equity analysis (e.g., spatial mismatch, opportunity benchmarking, policy intervention scenario analysis).


Asunto(s)
Accesibilidad a los Servicios de Salud , Transportes , Áreas de Influencia de Salud , Fricción , Ontario
17.
J Prosthet Dent ; 2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36609083

RESUMEN

Digital recording of the maxillomandibular relationship by using intraoral scanning in completely edentulous patients for computer-aided design and computer-aided manufacture implant-supported prostheses can be challenging. This clinical report describes the fabrication of complete-arch, screw-retained implant-supported prostheses in a completely edentulous patient with a fully digital workflow.

18.
J Prosthet Dent ; 130(1): 59-67, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34756606

RESUMEN

STATEMENT OF PROBLEM: Anodic oxidation of titanium implant abutment collars has been used to mask their unesthetic grayish color. However, the effect of anodic oxidation on the health and appearance of peri-implant soft tissues is unclear. PURPOSE: The purpose of this split-mouth clinical study was to investigate the effect of anodized titanium on the health and esthetics of peri-implant soft tissues. MATERIAL AND METHODS: A total of 60 osseointegrated implants placed in 30 participants were included in the present study. Each participant received 2 randomly allocated abutments, one with a pink anodized collar and the other with an unanodized one to form 2 groups: unanodized group (control group) and anodized group (experimental group). All implants were restored with lithium disilicate restorations. Evaluations of the peri-implant soft tissues were performed at the time of definitive restoration insertion (baseline) and after 3, 6, 12, and 18 months: peri-implant probing depth, soft tissue recession, modified sulcus bleeding index, modified plaque index, and modified gingival index. The esthetics of peri-implant soft tissues were evaluated by using the modified pink esthetic score. The paired t test or Wilcoxon signed-rank test was used for comparing the 2 study groups at each point of time depending on the normality of the variables (α=.05). To compare each variable at different time points within each group separately, repeated measures ANOVA or Friedman tests were used according to the normality of the variables, followed by post hoc pairwise comparisons by using the Bonferroni adjusted significance (α=.05). RESULTS: Five peri-implant soft tissue indices were followed up throughout the study. No statistically significant differences were found among the mean values of the tested indices in the anodized and unanodized groups throughout the evaluation periods (P>.05). The collective mean values of the modified pink esthetic score also showed no statistically significant differences between the groups (P>.05). CONCLUSIONS: Based on this split-mouth clinical study, pink anodized titanium abutment collars do not produce a clinically significant effect on the health or esthetics of peri-implant soft tissues.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Diente , Humanos , Pilares Dentales , Estética Dental , Titanio
19.
J Prosthet Dent ; 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36369061

RESUMEN

Custom healing abutments are important in establishing optimal esthetics for prosthesis-driven, implant-supported restorations. This report demonstrates a technique for constructing a custom healing abutment with computer-aided design and computer-aided manufacturing to save chairside time and provide predictable results.

20.
Geriatrics (Basel) ; 7(1)2022 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-35200527

RESUMEN

The new coronavirus disease 2019 (COVID-19) could be associated with elevated inflammatory cytokine levels, suggesting the involvement of cytokine release syndrome. This syndrome is characterized by release of interleukin 6 correlated with COVID-19 severity and mortality. Targeting IL-6 with Tocilizumab treatment could be a potential therapeutic option for old patients. We report the case of an 88-year-old man with COVID-19 disease who presented at the admission with anemia, fever, oxygen desaturation (92%), and inflammatory syndrome (C-reactive protein (CRP) at 182.5 mg/L; reference range <5.0 mg/L). After remaining CRP level increase (206.6 mg/L), Tocilizumab administration led to rapid clinical outcome and resolution of his inflammatory syndrome. This case report represents a supplementary data confirming the efficacy and safety of Tocilizumab for COVID-19 in elderly patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...