Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Ophthalmol ; 2020: 8704219, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32318286

RESUMEN

PURPOSE: To evaluate the prevalence, possible risk factors, and clinical results of femtosecond laser implanted intrastromal corneal ring segment (ICRS) extrusion in keratoconic eyes. Patients and Methods. This is a retrospective observational study evaluating 333 eyes of 269 patients who were subjected to femtosecond laser-implanted Keraring ICRS in the Sohag Refractive Center, Sohag, Egypt, from January 2014 to January 2019. The study included eyes with channels created by a femtosecond laser (60 kHz IntraLase femtosecond system; Advanced Medical Optics, Santa Ana, California, USA) with implantation of Keraring intrastromal corneal ring segments (Mediphacos, Belo Horizonte, Brazil). Patient data and causes of Keraring extrusions were identified as being those rings that migrated or showed melting of the cornea with no other reason which required segment removal. RESULTS: Seven eyes were found to fit the criteria of ring extrusion (2.1%) out of the 333 eyes which had Keraring implantation. All extruded rings were from patients with keratoconus grade 3, with eccentric cones, and with femtosecond creation of the tunnel. Four eyes belonging to 3 patients (57.1%) had a history of vernal Keratoconjunctivitis, yet they did not show signs of activity at the time of implantation. They reported excessive rubbing just before they presented with conjunctival hyperemia and foreign body sensation. Five eyes (71.4%) showed chronic sun exposure. The mean minimal corneal thickness was 401.85 µm (range 384-420 µm), while the mean maximum keratometry was 61 D (range 55.18-68.96 D). Most of the extruded rings had large arcs. Six eyes had crosslinking (CXL) at the same session of the Keraring implantation. The simultaneous CXL treatment is considered as a possible significant risk factor for ring extrusion. CONCLUSION: ICRS is an effective reversible option for patients with keratoconus who are intolerant to hard contact lenses, yet the choice of cases and ring segments is mandatory for satisfactory results. Moreover, meticulous history taking and examination reduces the incidence of complications including extrusion.

2.
J Ophthalmol ; 2019: 2965872, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31275630

RESUMEN

PURPOSE: To examine the morphological changes in the meibomian glands of patients with keratoconus as well as to study the relationship between these changes in the morphology and several tear film parameters. METHODS: Examination of the meibomian gland (MG) of 300 keratoconus patients presenting to the center using infrared noncontact meibography system (Sirius, CSO, Italy) between January 2017-January 2019. 100 eyes of healthy individuals were also enrolled as a control group. Tear breakup time (TBUT) test and Schirmer test II were evaluated. Subjective symptoms were also assessed using Ocular Surface Disease Index (OSDI). RESULTS: Mean age of keratoconus patients was 19 ± 12 years and 21 ± 14 years in control group. Average TBUT was 4.9 ± 2.1 sec. and average Schirmer test was 5.3 ± 2.2 mm which was significantly lower than control group (p=0.05). Meibomian gland dropout in the lower eyelid of the keratoconus group was as follows: grade 0 (no loss of meibomian glands): 100 eyes; grade 1 (gland dropout area <1/3 of the total meibomian glands): 85 eyes; grade 2 (gland dropout area 1/3 to 2/3): 68 eyes; and grade 3 (gland dropout >2/3): 47 eyes. CONCLUSION: Keratoconus shows significant meibomian gland dropout and distortion that can be recorded by noncontact meibography. Sirius meibography is a simple, cost-effective method of evaluating meibomian gland dropout as a part of the routine refractive examination.

3.
J Ophthalmol ; 2019: 5640356, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31275631

RESUMEN

PURPOSE: To report the characteristics of anterior and posterior corneal high-order aberrations in patients with different refractive errors. SETTING: This study was conducted at Sohag Refractive Center, Sohag, Egypt. DESIGN: This is a retrospective observational study. METHODS: This study evaluated 750 patients (750 eyes) who were seeking refractive surgery. The eyes were stratified into five groups (150 eyes/group) based on refractive error: mild-to-moderate myopia, high myopia, hyperopia, simple myopic astigmatism, and simple hypermetropic astigmatism. All patients were subjected to comprehensive ophthalmological examination including corneal topography and corneal aberrometry using the Scheimpflug-Placido topography (Sirius, CSO, Italy). RESULTS: Coma aberration was statistically significant when compared in all five groups (P=0.01). It was highest in the hypermetropia group (0.26 ± 0.12 µm) but lower in the moderate myopia, high myopia, myopic astigmatism, and hypermetropic astigmatism groups. Spherical aberration was lowest in the hypermetropia group and significantly different from that in the other groups. Trefoil was statistically insignificant when all groups were compared (P=0.062) but was highest in the myopic astigmatism group (0.24 ± 0.25 µm). Total RMS peaked in the hypermetropia group (0.99 ± 0.70). CONCLUSIONS: In normal corneas and regular refractive errors, the cornea-induced high-order aberration was minimal, and all types of refractive errors were associated with certain types of high-order aberrations, with a significant increase in spherical aberration in the hypermetropia group.

4.
J Ophthalmol ; 2019: 9312929, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31143475

RESUMEN

PURPOSE: To study the relation between the serum 25-hydroxyl vitamin D (OH D) level and the occurrence of age-related cataract in a case-control study. PATIENTS AND METHODS: 325 cataract patients and 385 control individuals of both sexes were examined for the 25-OH D level using the chemiluminescent microparticle immunoassay (CMIA) technology. RESULTS: Mean 25-OH D level in cataract patients was 7.6 ± 5.5 ± 11.2 ng/mL and median was 5.6 (2.6-31.9), while in the control group, mean 25-OH D level was 18.5 ± 9.6 ng/mL and median was 17.8 (3.4-37.8) (p value < 0.001). There was a statistically significant difference among the different types of cataracts with the lowest level in nuclear cataract. CONCLUSION: 25-OH D levels in all enrolled individuals were below the reference levels with a severe deficiency in cataract patients. These results might highlight the role of deficiency of 25-OH D in age-related cataract patients.

5.
J Ophthalmol ; 2015: 794854, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26693347

RESUMEN

Purpose. To evaluate the effect of preoperative and postoperative keratometry on the refractive outcome after laser in situ keratomileusis (LASIK) for moderate and high myopia. Methods. Records of 812 eyes (420 patients) with myopia ≥-6 D who had LASIK at Sohag Laser Center, Egypt, from January 2010 to November 2013, were retrospectively analyzed. Main outcome measures were postoperative corrected distance visual acuity (CDVA), postoperative spherical equivalence, and postoperative Q factor. Results. LASIK was performed in 812 eyes (mean age 21.8 ± 5.2 years). Patients were grouped according to the degree of preoperative myopia into three groups: Group 1, -6 D to -7.9 D; Group 2, -8 to -9.9 D; and Group 3, -10 to -12 D. The refractive outcome among the different myopia groups was stratified by pre- and postoperative keratometry. A trend toward greater undercorrection was noted in eyes with preoperative keratometry <43.5 D compared with those with steeper keratometry >46 D in all myopia groups. The undercorrection was also noted in postoperative keratometry groups <35 D. Conclusions. Preoperative and postoperative keratometry appeared to influence the refractive outcome especially in high myopic eyes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...