2.
J Clin Oncol ; : JCO2301983, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657187

RESUMEN

PURPOSE: The anti-NECTIN4 antibody-drug conjugate enfortumab vedotin (EV) is approved for patients with metastatic urothelial cancer (mUC). However, durable benefit is only achieved in a small, yet uncharacterized patient subset. NECTIN4 is located on chromosome 1q23.3, and 1q23.3 gains represent frequent copy number variations (CNVs) in urothelial cancer. Here, we aimed to evaluate NECTIN4 amplifications as a genomic biomarker to predict EV response in patients with mUC. MATERIALS AND METHODS: We established a NECTIN4-specific fluorescence in situ hybridization (FISH) assay to assess the predictive value of NECTIN4 CNVs in a multicenter EV-treated mUC patient cohort (mUC-EV, n = 108). CNVs were correlated with membranous NECTIN4 protein expression, EV treatment responses, and outcomes. We also assessed the prognostic value of NECTIN4 CNVs measured in metastatic biopsies of non-EV-treated mUC (mUC-non-EV, n = 103). Furthermore, we queried The Cancer Genome Atlas (TCGA) data sets (10,712 patients across 32 cancer types) for NECTIN4 CNVs. RESULTS: NECTIN4 amplifications are frequent genomic events in muscle-invasive bladder cancer (TCGA bladder cancer data set: approximately 17%) and mUC (approximately 26% in our mUC cohorts). In mUC-EV, NECTIN4 amplification represents a stable genomic alteration during metastatic progression and associates with enhanced membranous NECTIN4 protein expression. Ninety-six percent (27 of 28) of patients with NECTIN4 amplifications demonstrated objective responses to EV compared with 32% (24 of 74) in the nonamplified subgroup (P < .001). In multivariable Cox analysis adjusted for age, sex, and Bellmunt risk factors, NECTIN4 amplifications led to a 92% risk reduction for death (hazard ratio, 0.08 [95% CI, 0.02 to 0.34]; P < .001). In the mUC-non-EV, NECTIN4 amplifications were not associated with outcomes. TCGA Pan-Cancer analysis demonstrated that NECTIN4 amplifications occur frequently in other cancers, for example, in 5%-10% of breast and lung cancers. CONCLUSION: NECTIN4 amplifications are genomic predictors of EV responses and long-term survival in patients with mUC.

3.
J Clin Med ; 13(4)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38398270

RESUMEN

(1) Background: External beam radiotherapy (EBRT) and concurrent chemotherapy, followed by brachytherapy (BT), offer a standard of care for patients with locally advanced cervical carcinoma. Conventionally, large safety margins are required to compensate for organ movement, potentially increasing toxicity. Lately, daily high-quality cone beam CT (CBCT)-guided adaptive radiotherapy, aided by artificial intelligence (AI), became clinically available. Thus, online treatment plans can be adapted to the current position of the tumor and the adjacent organs at risk (OAR), while the patient is lying on the treatment couch. We sought to evaluate the potential of this new technology, including a weekly shuttle-based 3T-MRI scan in various treatment positions for tumor evaluation and for decreasing treatment-related side effects. (2) Methods: This is a prospective one-armed phase-II trial consisting of 40 patients with cervical carcinoma (FIGO IB-IIIC1) with an age ≥ 18 years and a Karnofsky performance score ≥ 70%. EBRT (45-50.4 Gy in 25-28 fractions with 55.0-58.8 Gy simultaneous integrated boosts to lymph node metastases) will be accompanied by weekly shuttle-based MRIs. Concurrent platinum-based chemotherapy will be given, followed by 28 Gy of BT (four fractions). The primary endpoint will be the occurrence of overall early bowel and bladder toxicity CTCAE grade 2 or higher (CTCAE v5.0). Secondary outcomes include clinical feasibility, quality of life, and imaging-based response assessment.

4.
Geburtshilfe Frauenheilkd ; 83(8): 919-962, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37588260

RESUMEN

Summary The S3-guideline on endometrial cancer, first published in April 2018, was reviewed in its entirety between April 2020 and January 2022 and updated. The review was carried out at the request of German Cancer Aid as part of the Oncology Guidelines Program and the lead coordinators were the German Society for Gynecology and Obstetrics (DGGG), the Gynecology Oncology Working Group (AGO) of the German Cancer Society (DKG) and the German Cancer Aid (DKH). The guideline update was based on a systematic search and assessment of the literature published between 2016 and 2020. All statements, recommendations and background texts were reviewed and either confirmed or amended. New statements and recommendations were included where necessary. Aim The use of evidence-based risk-adapted therapies to treat women with endometrial cancer of low risk prevents unnecessarily radical surgery and avoids non-beneficial adjuvant radiation therapy and/or chemotherapy. For women with endometrial cancer and a high risk of recurrence, the guideline defines the optimum level of radical surgery and indicates whether chemotherapy and/or adjuvant radiation therapy is necessary. This should improve the survival rates and quality of life of these patients. The S3-guideline on endometrial cancer and the quality indicators based on the guideline aim to provide the basis for the work of certified gynecological cancer centers. Methods The guideline was first compiled in 2018 in accordance with the requirements for S3-level guidelines and was updated in 2022. The update included an adaptation of the source guidelines identified using the German Instrument for Methodological Guideline Appraisal (DELBI). The update also used evidence reviews which were created based on selected literature obtained from systematic searches in selected literature databases using the PICO process. The Clinical Guidelines Service Group was tasked with carrying out a systematic search and assessment of the literature. Their results were used by interdisciplinary working groups as a basis for developing suggestions for recommendations and statements which were then modified during structured online consensus conferences and/or additionally amended online using the DELPHI process to achieve a consensus. Recommendations Part 1 of this short version of the guideline provides recommendations on epidemiology, screening, diagnosis, and hereditary factors. The epidemiology of endometrial cancer and the risk factors for developing endometrial cancer are presented. The options for screening and the methods used to diagnose endometrial cancer are outlined. Recommendations are given for the prevention, diagnosis, and therapy of hereditary forms of endometrial cancer. The use of geriatric assessment is considered and existing structures of care are presented.

5.
Rofo ; 195(12): 1106-1121, 2023 12.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37467780

RESUMEN

BACKGROUND: Cystic (CE) and alveolar (AE) echinococcoses are zoonotic parasitoses that may pose diagnostic problems due to their relative rarity in Middle Europe. METHODS: Based on a recent literature search and the observation of casuistics from a national echinococcosis treatment center, epidemiological, radiological, and therapeutic fundamentals are presented and important differences between AE and CE are discussed. RESULTS AND CONCLUSION: AE and CE must be regarded as completely different diseases, which differ from each other in every significant aspect. This applies not only to the epidemiological background of the patients but also to the biology of the diseases and their respective imaging features. KEY POINTS: · AE and CE are very distinct from one another and must be considered separately.. · AE is endemic in Middle Europe and is known as malignant parasitosis due to its destructive growth form.. · CE is primarily seen in Middle Europe in individuals with migration background and has a rather benign character.. CITATION FORMAT: · Weber TF, Mokry T, Stojkovic M. Die Echinokokkosen - Einblicke aus Sicht der Radiologie. Fortschr Röntgenstr 2023; 195: 1106 - 1121.


Asunto(s)
Equinococosis , Humanos , Equinococosis/diagnóstico por imagen , Equinococosis/tratamiento farmacológico , Europa (Continente) , Radiólogos
7.
Rofo ; 194(7): 747-754, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35211927

RESUMEN

PURPOSE: In patients with malignant lymphoma, disease activity is recommended to be assessed by FDG-PET/CT and the Deauville five-point scale (5-PS). The purpose of this study was to explore the potential of iodine concentration measured in contrast-enhanced dual-layer spectral detector CT (SDCT) as an alternative surrogate parameter for lymphoma disease activity by investigating its correlation with maximum standardized uptake values (SUVmax) and 5-PS. MATERIALS AND METHODS: 25 patients were retrospectively analyzed. Contrast-enhanced SDCT and FDG-PET/CT were performed in the same treatment interval within at most 3 months. CT attenuation values (AV), absolute iodine concentrations (aIC), and normalized iodine concentrations (nIC) of lymphoma lesions were correlated with SUVmax using Spearman's rank correlation coefficient. The performance of aIC and nIC to detect lymphoma activity (defined as 5-PS > 3) was determined using ROC curves. RESULTS: 60 lesions were analyzed, and 31 lesions were considered active. AV, aIC, and nIC all correlated significantly with SUVmax. The strongest correlation (Spearman ρ = 0.71; p < 0.001) and highest area under the ROC curve (AUROC) for detecting lymphoma activity were observed for nIC normalized to inferior vena cava enhancement (AUROC = 0.866). The latter provided sensitivity, specificity, and diagnostic accuracy of 87 %, 75 %, and 80 %, respectively, at a threshold of 0.20. ROC analysis for AV (AUROC = 0.834) and aIC (AUROC = 0.853) yielded similar results. CONCLUSION: In malignant lymphomas, there is a significant correlation between metabolic activity as assessed by FDG-PET/CT and iodine concentration as assessed by SDCT. Iodine concentration shows promising diagnostic performance for detecting lymphoma activity and may represent a potential imaging biomarker. KEY POINTS: · Iodine concentration correlates significantly with SUVmax in lymphoma patients. · Iodine concentration may represent a potential imaging biomarker for detecting lymphoma activity. · Normalization of iodine concentration improves diagnostic performance of iodine concentration. CITATION FORMAT: · Gehling K, Mokry T, Do TD et al. Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity. Fortschr Röntgenstr 2022; 194: 747 - 754.


Asunto(s)
Yodo , Linfoma , Diagnóstico Diferencial , Fluorodesoxiglucosa F18 , Humanos , Linfoma/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Estudios Retrospectivos
8.
Radiologe ; 61(12): 1078-1089, 2021 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-34889973

RESUMEN

BACKGROUND: Plasma cell dyscrasias are a spectrum of diseases characterized by clonal plasma cell proliferation. Important entities within this group are monoclonal gammopathy of unknown significance, smoldering multiple myeloma, and symptomatic multiple myeloma. PURPOSE: The goal of this review is to illustrate plasma cell dyscrasia imaging findings of bone and bone marrow as seen on whole-body computed tomography (CT) and magnetic resonance imaging (MRI) and to discuss the relevance of imaging for management of patients with plasma cell dyscrasias. MATERIALS AND METHODS: Selective literature search with analysis of dedicated original research articles and reviews and discussion of clinical guidelines. RESULTS: Diagnostic classification of plasma cell dyscrasias is based on the SLiM-CRAB criteria. CT primarily represents imaging of mineralized bone to show osseous end organ damage by detecting osteodestruction. MRI is primarily used for bone marrow imaging to detect diffuse or focal bone marrow infiltration, even in the absence of bone destruction. Different patterns of bone marrow infiltration can be distinguished. Treatment response is associated with characteristic imaging signs of lesion regression. CONCLUSION: Imaging plays a prominent role in treatment stratification of patients with plasma cell dyscrasia at first diagnosis and during follow-up.


Asunto(s)
Mieloma Múltiple , Paraproteinemias , Huesos , Humanos , Imagen por Resonancia Magnética , Mieloma Múltiple/diagnóstico por imagen , Paraproteinemias/diagnóstico por imagen , Tomografía Computarizada por Rayos X
9.
Magn Reson Imaging ; 80: 50-57, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33905830

RESUMEN

PURPOSE: We aimed to investigate whether quantitative diffusivity variables of healthy ovaries vary during the menstrual cycle and to evaluate alterations in women using oral contraceptives (OC). METHODS: This prospective study (S-339/2016) included 30 healthy female volunteers, with (n = 15) and without (n = 15) intake of OC between 07/2017 and 09/2019. Participants underwent 3T diffusion-weighted MRI (b-values 0-2000 s/mm2) three times during a menstrual cycle (T1 = day 1-5; T2 = day 7-12; T3 = day 19-24). Both ovaries were manually three-dimensionally segmented on b = 1500 s/mm2; apparent diffusion coefficient (ADC) calculation and kurtosis fitting (Dapp, Kapp) were performed. Differences in ADC, Dapp and Kapp between time points and groups were compared using repeated measures ANOVA and t-test after Shapiro-Wilk and Brown-Forsythe test for normality and equal variance. RESULTS: In women with a natural menstrual cycle, ADC and kurtosis variables showed significant changes in ovaries with the dominant follicle between T1 vs T2 and T1 vs T3, whilst no differences were observed between T2 vs T3: ADC ± SD for T1 1.524 ± 0.160, T2 1.737 ± 0.160, and T3 1.747 ± 0.241 µm2/ms (p = 0.01 T2 vs T1; p = 1.0 T2 vs T3, p = 0.003 T3 vs T1); Dapp ± SD for T1 2.018 ± 0.140, T2 2.272 ± 0.189, and T3 2.230 ± 0.256 µm2/ms (p = 0.003 T2 vs T1, p = 1.0 T2 vs T3, p = 0.02 T3 vs T1); Kapp ± SD for T1 0.614 ± 0.0339, T2 0.546 ± 0.0637, and T3 0.529 ± 0.0567 (p < 0.001 T2 vs T1, p = 0.86 T2 vs T3, p < 0.001 T3 vs T1). No significant differences were found in the contralateral ovaries or in females taking OC. CONCLUSION: Physiological cycle-dependent changes in quantitative diffusivity variables of ovaries should be considered especially when interpreting radiomics analyses in reproductive women.


Asunto(s)
Anticonceptivos Orales , Ovario , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Ciclo Menstrual , Ovario/diagnóstico por imagen , Estudios Prospectivos
10.
BMC Med Imaging ; 21(1): 10, 2021 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-33430780

RESUMEN

BACKGROUND: Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP. METHODS: This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis. RESULTS: Overall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s). CONCLUSIONS: Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.


Asunto(s)
Conductos Biliares/diagnóstico por imagen , Pancreatocolangiografía por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Páncreas/diagnóstico por imagen , Adulto , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Respiración , Estudios Retrospectivos , Adulto Joven
11.
Artículo en Inglés | MEDLINE | ID: mdl-33087940

RESUMEN

BACKGROUND AND AIM: Assessment of appropriateness of CT pulmonary angiograms (CTPA) in patients with suspected pulmonary embolism (PE) is based on risk stratification algorithms such as simplified the Geneva Score (sGS) in combination with D-dimer blood tests. The aim of this study was to validate the diagnostic yield and appropriateness of CTPA examinations in accordance with 2014 European Society of Cardiology (ESC) guidelines. MATERIALS AND METHODS: Data from 155 outpatients who underwent CTPA for clinical suspicion of PE were gathered from the radiology information system (RIS) and the clinical information system (CIS). We assessed the presence of sGS items and D-dimer blood test results in RIS from CTPA request forms and from clinical documentation in CIS. RESULTS: Based on the RIS, there were 2.6% patients with high (sGS≥3) and 97.4% patients with low pre-test PE probability (sGS<3), and CTPA indication was formally comprehendible in 75.5% using sGS and D-dimer blood tests. Based on RIS and CIS data in combination, there were 41.3% patients with high and 58.7% patients with low pre-test PE probability, and CTPA indication was formally comprehendible in 88.4%. Using RIS and CIS in combination, PE probability was upgraded from low to high probability in 39.7% compared with RIS alone. In 12.9%, there was a lack of data in RIS for CTPA justification. CONCLUSION: There is a high diagnostic yield when applying current diagnostic guidelines to our data. There was however a notable discrepancy between the data transferred to the CTPA request forms from the full clinical documentation, therefore not readily available for clinical decision making.


Asunto(s)
Angiografía por Tomografía Computarizada , Embolia Pulmonar/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Embolia Pulmonar/sangre , Estudios Retrospectivos , Medición de Riesgo
12.
Insights Imaging ; 11(1): 106, 2020 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-32990824

RESUMEN

OBJECTIVES: Our aim was to develop a structured reporting concept (structured oncology report, SOR) for general follow-up assessment of cancer patients in clinical routine. Furthermore, we analysed the report quality of SOR compared to conventional reports (CR) as assessed by referring oncologists. METHODS: SOR was designed to provide standardised layout, tabulated tumour burden documentation and standardised conclusion using uniform terminology. A software application for reporting was programmed to ensure consistency of layout and vocabulary and to facilitate utilisation of SOR. Report quality was analysed for 25 SOR and 25 CR retrospectively by 6 medical oncologists using a 7-point scale (score 1 representing the best score) for 6 questionnaire items addressing different elements of report quality and overall satisfaction. A score of ≤ 3 was defined as a positive rating. RESULTS: In the first year after full implementation, 7471 imaging examinations were reported using SOR. The proportion of SOR in relation to all oncology reports increased from 49 to 95% within a few months. Report quality scores were better for SOR for each questionnaire item (p < 0.001 each). Averaged over all questionnaire item scores were 1.98 ± 1.22 for SOR and 3.05 ± 1.93 for CR (p < 0.001). The overall satisfaction score was 2.15 ± 1.32 for SOR and 3.39 ± 2.08 for CR (p < 0.001). The proportion of positive ratings was higher for SOR (89% versus 67%; p < 0.001). CONCLUSIONS: Department-wide structured reporting for follow-up imaging performed for assessment of anticancer treatment efficacy is feasible using a dedicated software application. Satisfaction of referring oncologist with report quality is superior for structured reports.

13.
Surg Oncol ; 35: 24-33, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32818879

RESUMEN

BACKGROUND AND OBJECTIVES: Recurrence is a frequent concern in curatively resected CRC liver metastases. Translational research suggests that regeneration upon hepatectomy may also alleviate metastatic recurrence; however, the significance in patients is unclear. We therefore sought to study the effect of liver regeneration on tumor recurrence in patients. METHODS: In this retrospective cohort study, we included 58 out of 186 potentially eligible patients from our prospectively maintained database of CRC liver metastasis patients between 2001 and 2012 with a median follow-up of 42 months who underwent a formal right or left hemihepatectomy. Liver regeneration in CT volumetry was correlated with recurrence of CRC liver metastases and overall survival. RESULTS: Liver regeneration increased up to 14 months to 21.0% for left and 122.6% for right hemihepatectomy, respectively, with comparable final volumes. Regeneration was independent of initial tumor stage, number of metastases, and preoperative chemotherapy. Patients with lower liver regeneration showed earlier recurrence of CRC liver metastases (p = 0.006). Overall survival did not differ in patients with weak versus strong liver regeneration. CONCLUSIONS: The extent of liver regeneration after major hepatectomy does not impede overall survival. Therefore, our data encourage aggressive therapeutical regimes for CRC liver metastases involving major hepatectomies as part of a curative approach.


Asunto(s)
Neoplasias Colorrectales/cirugía , Hepatectomía/mortalidad , Neoplasias Hepáticas/cirugía , Regeneración Hepática , Cuidados Posoperatorios , Neoplasias Colorrectales/patología , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia
14.
Radiology ; 296(2): 358-369, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32544033

RESUMEN

Background MRI with contrast material enhancement is the imaging modality of choice to evaluate sonographically indeterminate adnexal masses. The role of diffusion-weighted MRI, however, remains controversial. Purpose To evaluate the diagnostic performance of ultra-high-b-value diffusion kurtosis MRI in discriminating benign and malignant ovarian lesions. Materials and Methods This prospective cohort study evaluated consecutive women with sonographically indeterminate adnexal masses between November 2016 and December 2018. MRI at 3.0 T was performed, including diffusion-weighted MRI (b values of 0-2000 sec/mm2). Lesions were segmented on b of 1500 sec/mm2 by two readers in consensus and an additional independent reader by using full-lesion segmentations on a single transversal slice. Apparent diffusion coefficient (ADC) calculation and kurtosis fitting were performed. Differences in ADC, kurtosis-derived ADC (Dapp), and apparent kurtosis coefficient (Kapp) between malignant and benign lesions were assessed by using a logistic mixed model. Area under the receiver operating characteristic curve (AUC) for ADC, Dapp, and Kapp to discriminate malignant from benign lesions was calculated, as was specificity at a sensitivity level of 100%. Results from two independent reads were compared. Histopathologic analysis served as the reference standard. Results A total of 79 ovarian lesions in 58 women (mean age ± standard deviation, 48 years ± 14) were evaluated. Sixty-two (78%) lesions showed benign and 17 (22%) lesions showed malignant histologic findings. ADC and Dapp were lower and Kapp was higher in malignant lesions: median ADC, Dapp, and Kapp were 0.74 µm2/msec (range, 0.52-1.44 µm2/msec), 0.98 µm2/msec (range, 0.63-2.12 µm2/msec), and 1.01 (range, 0.69-1.30) for malignant lesions, and 1.13 µm2/msec (range, 0.35-2.63 µm2/msec), 1.45 µm2/msec (range, 0.44-3.34 µm2/msec), and 0.65 (range, 0.44-1.43) for benign lesions (P values of .01, .02, < .001, respectively). AUC for Kapp of 0.85 (95% confidence interval: 0.77, 0.94) was higher than was AUC from ADC of 0.78 (95% confidence interval: 0.67, 0.89; P = .047). Conclusion Diffusion-weighted MRI by using quantitative kurtosis variables is superior to apparent diffusion coefficient values in discriminating benign and malignant ovarian lesions and might be of future help in clinical practice, especially in patients with contraindication to contrast media application. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Ováricas/diagnóstico por imagen , Ovario/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Neoplasias Ováricas/clasificación , Neoplasias Ováricas/patología , Ovario/patología , Estudios Prospectivos , Sensibilidad y Especificidad
15.
Radiologe ; 60(5): 445-458, 2020 May.
Artículo en Alemán | MEDLINE | ID: mdl-32240326

RESUMEN

BACKROUND: Malignant lymphomas represent approximately 5% of all cancers. Imaging procedures play a crucial role concerning initial staging and assessment of the response to treatment. OBJECTIVE: This article gives an overview of the significance of imaging procedures in the treatment of patients with malignant lymphomas at various times during treatment. These include the initial assessment of the extent of the disease and staging during and after treatment under consideration of the current classification systems. MATERIAL AND METHODS: A selective literature search was carried out with analysis of dedicated original research articles and reviews as well as a discussion of the clinical guidelines. RESULTS: Computed tomography (CT) is the basic diagnostic tool in patients with malignant lymphomas. Particularly important is fluorodeoxyglucose (FDG) positron emission tomography (PET) CT, which enables a more accurate stage definition and a better assessment of the response to treatment in FDG-avid lymphoma subtypes. Using the FDG-PET/CT-based Deauville score persisting disease activity can be identified in residual masses and refractory disease can be distinguished from complete metabolic remission. The use of magnetic resonance imaging (MRI) with diffusion-weighted imaging can represent a future alternative but is, however, not yet sufficiently standardized and validated. CONCLUSION: The standardized analysis and reporting of purely morphological and metabolic imaging procedures is the backbone of treatment decisions in patients with malignant lymphomas.


Asunto(s)
Linfoma/diagnóstico por imagen , Linfoma/patología , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética/métodos , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos
18.
BMC Med Imaging ; 19(1): 20, 2019 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-30808320

RESUMEN

BACKGROUND: One of the major causes of perioperative mortality of patients undergoing major hepatic resections is post-hepatectomy liver failure (PHLF). For preoperative appraisal of the risk of PHLF it is important to accurately predict resectate volume and future liver remnant volume (FLRV). The objective of our study is to prospectively evaluate the accuracy of hemihepatectomy resectate volumes that are determined by computed tomography volumetry (CTV) when compared with intraoperatively measured volumes and weights as gold standard in patients undergoing hemihepatectomy. METHODS: Twenty four patients (13 women, 11 men) scheduled for hemihepatectomy due to histologically proven primary or secondary hepatic malignancies were included in our study. CTV was performed using a semi-automated module (S, hereinafter) (syngo.CT Liver Analysis VA30, Siemens Healthcare, Germany). Conversion factors between CT volumes on the one side and intraoperative volumes and weights on the other side were calculated using the method of least squares. Absolute and relative disagreements between CT volumes and intraoperative volumes were determined. RESULTS: A conversion factor of c = 0.906 most precisely predicted intraoperative volumes of exsanguinated hemihepatectomy specimens from CT volumes in all patients with mean absolute and relative disagreements between CT volumes and intraoperative volumes of 57 ml and 6.3%. The use of operation-specific conversion factors yielded even better results. CONCLUSIONS: CTV performed with S accurately predicts intraoperative volumes of hemihepatectomy specimens when applying conversion factors which compensate for exsanguination. This allows to precisely estimate the FLRV and thus minimize the risk of PHLF in patients undergoing major hepatic resections.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Hepatectomía/efectos adversos , Neoplasias Hepáticas/cirugía , Hígado/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hígado/cirugía , Fallo Hepático/etiología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Resultado del Tratamiento , Carga Tumoral
19.
Neurourol Urodyn ; 38(1): 369-378, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30387537

RESUMEN

AIMS: To develop MR-based measurement technique to evaluate the postoperative dimension and location of implanted magnetic resonance (MR)-visible meshes. METHODS: This technique development study reports findings of six patients (A-F) with cystoceles treated with anterior vaginal MR-visible Fe3 O4 -polypropylene implants. Implanted meshes were reconstructed from 3 months and/or 1 year postsurgical MR-images using 3D Slicer®. Measurements including mesh length, distance to the ischial spines, pudendal, and obturator neurovascular bundles and urethra were obtained using software Rhino® and a custom Matlab® program. The range of implanted mesh length and their placements were reported and compared with mesh design and implantation recommendations. With the anterior/posterior-mesh-segment-ratio mesh shrinkage localization was evaluated. RESULTS: Examinations were possible for patients A-D 3 months and for A, C, E, and F 1 year postsurgical. The mesh was at least 40% shorter in all patients 3 months and/or 1 year postoperatively. A, B showed shrinkage in the anterior segment, D, E in the posterior segment (Patients C, F not applicable due to intraoperative mesh trimming). Patient E presented pain in the area of mesh shrinkage. In Patient C posterior mesh fixations were placed in the iliococcygeal muscle rather than sacrospinous ligaments. Arm placement less than 20 mm from the pudendal neurovascular bundles was seen in all cases. The portion of the urethra having mesh underneath it ranged from 19% to 55%. CONCLUSIONS: MRI-based measurement techniques have been developed to quantify implanted mesh location and dimension. Mesh placement variations possibly correlating with postoperative complications can be illustrated.


Asunto(s)
Cistocele/cirugía , Imagenología Tridimensional , Diafragma Pélvico/cirugía , Prolapso de Órgano Pélvico/cirugía , Mallas Quirúrgicas , Anciano , Cistocele/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Diafragma Pélvico/diagnóstico por imagen , Prolapso de Órgano Pélvico/diagnóstico por imagen
20.
Medicine (Baltimore) ; 97(47): e13277, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30461635

RESUMEN

RATIONALE: We present a case of incidental venous contrast pooling and layering in a patient without sudden cardiac arrest or cardiogenic shock. PATIENT CONCERNS: The patient presented with only discrete symptoms and did not suffer fatal cessation of the cardiac pump function during or shortly after the scan. DIAGNOSIS: The patient showed stigmata of venous gravity-dependent pooling and layering of contrast medium, which has frequently been described as a sign of imminent cardiogenic shock and cardiac arrest. INTERVENTIONS: A cardiologic consultation including echocardiography was initiated. OUTCOMES: Echocardiography confirmed valvular heart disease and biventricular heart failure. A subsequent follow-up CT acquired 8 months after the incidental finding showed no signs of dependent contrast pooling. LESSONS: Pooling and layering of contrast medium can occur in patients not suffering acute fatal cessation of the cardiac pump function. Nonetheless, any signs of venous pooling observed in CT examinations, especially gravity-dependent layering of contrast medium, are indicative of severe heart dysfunction and should prompt immediate cardio-pulmonary monitoring and increased level of medical care.


Asunto(s)
Sistema Cardiovascular , Medios de Contraste/farmacología , Unión Esofagogástrica , Tomografía Computarizada Espiral/efectos adversos , Sistema Cardiovascular/diagnóstico por imagen , Sistema Cardiovascular/fisiopatología , Ecocardiografía/métodos , Unión Esofagogástrica/irrigación sanguínea , Unión Esofagogástrica/diagnóstico por imagen , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Flujo Sanguíneo Regional , Tomografía Computarizada Espiral/métodos
SELECCIÓN DE REFERENCIAS