Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Arch Pathol Lab Med ; 137(12): 1788-91, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24283860

RESUMEN

CONTEXT: It is recommended that hemoglobin (Hb) A1c (Hb A1c) not be used to assess average glycemia in patients who have altered red blood cell life span. OBJECTIVE: To investigate the frequency of reporting an Hb A1c value for Hb variant samples that do not include Hb A. DESIGN: Hb A1c samples (n = 500) were procured and screened for Hb variants that may affect Hb A1c interpretation (Hb SS, Hb SC, and Hb S-ß-thalassemia). Five of each of these samples were tested by ion-exchange high-performance liquid chromatography, immunoturbidimetric assay, second-generation immunoturbidimetric assay, and affinity chromatography. RESULTS: Eleven (2.2%) homozygous Hb SS, 6 (1.2%) Hb SC, and 5 (1.0%) Hb S-ß-thalassemia samples were identified out of the 500 samples tested. Three of 4 instruments investigated in this study are known to not be plagued by analytic interference from these Hb variants but disturbingly reported Hb A1c values in the absence of Hb A. CONCLUSIONS: The improved analytic specificity of Hb A1c platforms has by and large eliminated interferences from the most common heterozygous Hb variants. A consequence, however, is the potential for unintended reporting of Hb A1c results in the presence of homozygous and compound heterozygous Hb variants that lack Hb A and the inability to distinguish those samples not recommended to be used for patient care. The ability to identify samples harboring Hb variants that preclude the utility of Hb A1c may be beneficial in high prevalence populations.


Asunto(s)
Errores Diagnósticos , Hemoglobina Glucada/análisis , Hemoglobinas/clasificación , Hiperglucemia/sangre , Hiperglucemia/diagnóstico , Variación Genética/genética , Pruebas Hematológicas , Hemoglobinas/genética , Heterocigoto , Homocigoto , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
Clin Biochem ; 46(7-8): 656-64, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23353132

RESUMEN

OBJECTIVES: To develop and validate liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for the direct measurement of total and free testosterone in patient samples on two different analytical systems. DESIGN AND METHODS: An API 4000 and 5000 triple quadropoles were used and compared; the former is reported to be 3-5 times less sensitive, as was used to set the quantitation limits. Free testosterone was separated from the protein-bound fraction by equilibrium dialysis followed by derivatization. Either free or total testosterone, and a deuterated internal standard (d3-testosterone) were extracted by liquid-liquid extraction. The validation results were compared to two different clinical laboratories. RESULTS: The use of d2-testosterone was found to be unacceptable for our method. The total testosterone LC-MS/MS methods on both systems were linear over a wide concentration range of 1.5-2000ng/dL. Free testosterone was measured directly using equilibrium dialysis coupled LC-MS/MS and linear over the concentration range of 2.5-2500pg/mL. Good correlation (total testosterone, R(2)=0.96; free testosterone, R(2)=0.98) was observed between our LC-MS/MS systems and comparator laboratory. However, differences in absolute values for both free and total testosterone measurements were observed while a comparison to a second published LC-MS/MS method showed excellent correlation. Free and total testosterone measurements correlated well with clinical observations. CONCLUSIONS: To our knowledge, this is the first published validation of free and total testosterone methods across two analytical systems of different analytical sensitivities. A less sensitive system does not sacrifice analytical or clinical sensitivity to directly measure free and total testosterone in patient samples.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Testosterona/análisis , Deuterio , Humanos , Extracción Líquido-Líquido , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Testosterona/sangre
6.
Clin Chim Acta ; 420: 104-8, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23262370

RESUMEN

BACKGROUND: Chronic kidney disease often goes undetected due to the insensitivity of current methods to accurately assess glomerular filtration rate (GFR) in early stages of renal dysfunction. The clearance of exogenously introduced iothalamate, a commonly used radiopaque agent, is an alternative to inulin clearance for the assessment of renal function and its use in calculating GFR can serve as a screening tool for kidney transplant donors. METHODS: A method was developed to measure iothalamate in plasma and urine samples by HPLC combined with electrospray positive ionization tandem mass spectrometry (MS/MS). Iothalamate is isolated from plasma by methanol extraction and urine using a quick-spin filtration approach, then monitored by multiple reaction monitoring using the hydrogen adduct mass transitions. Iohexol was used as an internal standard. RESULTS: Iothalamate was measured within an analytical run time of 5 min, with a lower limit of quantification of 18.75 ng/ml. The intraassay and interassay variations of the plasma and urine iothalamate assays were both <9%. Recovery from plasma and urine samples ranged from 93.6% to 104.1%. GFR was calculated using the patient's urine flow rate and plasma and urine iothalamate values. Linear correlations tested by LC-MS/MS and an accepted capillary electrophoresis (CE) assay showed similar results (GFR, r=0.92, Sy/x=10.3). CONCLUSIONS: We developed and validated an LC-MS/MS method for quantitating iothalamate in plasma and urine to calculate GFR used for screening potential kidney donors in our hospital system. A less sensitive mass spectrometry system does not sacrifice analytical or clinical sensitivity for measuring GFR.


Asunto(s)
Análisis Químico de la Sangre , Cromatografía Liquida , Ácido Yotalámico/análisis , Pruebas de Función Renal , Espectrometría de Masas en Tándem , Obtención de Tejidos y Órganos , Humanos , Límite de Detección , Factores de Tiempo
7.
Arch Pathol Lab Med ; 136(11): 1423-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23106588

RESUMEN

CONTEXT: Laboratory medicine is an integral component of patient care. Approximately 60% to 70% of medical decisions are based on laboratory results. Physicians in specialties that order the tests are teaching medical students laboratory medicine and test use with minimal input from laboratory scientists who implement and maintain the quality control for those tests. OBJECTIVE: To develop, implement, and evaluate a 1.5-day medical student clinical laboratory experience for fourth-year medical students in their last month of training. DESIGN: The experience was devised and directed by laboratory scientists and included a panel discussion, laboratory tours, case studies that focused on the goals and objectives recently published by the Academy of Clinical Laboratory Physicians and Scientists, and medical-student presentations highlighting salient points of the experience. The same knowledge quiz was administered at the beginning and end of the experience and 84 students took both quizzes. RESULTS: A score of 7 or more was obtained by 16 students (19%) on the initial quiz, whereas 34 (40%) obtained the same score on the final quiz; the improvement was found to be statistically significant (P  =  .002; t  =  3.215), particularly in 3 out of the 10 questions administered. CONCLUSIONS: Although the assessment can only measure a small amount of knowledge recently acquired, the improvement observed by fourth-year medical students devoting a short period to learning laboratory medicine principles was encouraging. This medical student clinical laboratory experience format allowed teaching of a select group of laboratory medicine principles in 1.5 days to an entire medical school class.


Asunto(s)
Ciencia del Laboratorio Clínico/educación , Patología Clínica/educación , Curriculum , Educación de Pregrado en Medicina , Georgia , Humanos , Laboratorios de Hospital , Facultades de Medicina , Estudiantes de Medicina
9.
J Chromatogr B Analyt Technol Biomed Life Sci ; 893-894: 168-72, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22425273

RESUMEN

An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the direct measurement of argatroban in human plasma was developed and compared with the activity-based Hemoclot Thrombin Inhibitors assay. UPLC-MS/MS was performed using diclofenac as an internal standard. In summary, argatroban and diclofenac were extracted from 100 µL of plasma using a methanol precipitation protocol, and chromatographic separation was performed on an ACQUITY TQD mass spectrometer using a UPLC C18 BEH 1.7 µm column with a water and methanol gradient containing 0.1% formic acid. The detection and quantitation were performed using positive ion electrospray ionization and multiple reaction monitoring (MRM) mode. The UPLC-MS/MS method was linear over the concentration range of 0.003-3.0 µg/mL, with a lower limit of quantitation for argatroban of 0.003 µg/mL. The intra- and inter-assay imprecision was less than 12% at the plasma argatroban concentrations tested. Good correlation was demonstrated between the UPLC-MS/MS method and the indirect activity-based assay for determination of argatroban. However, increased plasma fibrinogen levels caused underestimation of argatroban levels using the indirect activity-based assay, whereas the UPLC-MS/MS method was unaffected. UPLC-MS/MS provides a relatively simple, sensitive, and rapid means of argatroban monitoring. It has successfully been applied to assess plasma argatroban concentrations in hospitalized patients and may provide a more accurate determination of argatroban concentrations than an activity-based assay in certain clinical conditions.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/métodos , Ácidos Pipecólicos/sangre , Espectrometría de Masas en Tándem/métodos , Arginina/análogos & derivados , Humanos , Modelos Lineales , Reproducibilidad de los Resultados , Sulfonamidas
10.
Thromb Haemost ; 106(6): 1215-23, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22071880

RESUMEN

Prothrombin complex concentrates (PCCs) and fresh-frozen plasma (FFP) have been clinically used for acute warfarin reversal. The recovery of prothrombin time (PT) or international normalised ratio (INR) is often reported as an endpoint, but haemostatic efficacies of PCCs and FFP may not be fully reflected in static clotting test in platelet-poor plasma. Using various in vitro assays, we compared the effects of two PCC preparations (3-factor PCC; Bebulin and 4-factor PCC; Beriplex) and FFP on warfarin reversal under static and flow conditions. First, we added an aliquot of either PCC (0.3 or 0.72 U/ml) or 20% FFP (v/v) to commercial warfarin plasma (INR 3.2, or 10.3), and then measured PT, factor II, factor VII, and thrombin generation. Subsequently, we collected whole blood samples from six consented warfarin-treated patients with mean INR 3.0 ± 0.5 (range 2.5-3.7), and compared clot formation under flow conditions at 280 s-1 before and after addition of either PCC preparation (0.3 and 0.6 U/ml) or 20% of FFP (v/v). PT/INR were restored by either PCC in plasma with INR 3.0, but they were more effectively corrected by 4-factor PCC than 3-factor PCC in plasma with INR 10.3. Effects of FFP were similar to 0.3 U/ml of PCCs in terms of PT, but FFP was less efficacious than PCCs in recovering thrombin generation or factor II levels. In flow experiments, the onset of thrombus formation was shortened by either PCC, but not by FFP, contrary to shortened PT values. For warfarin reversal 20% volume replacement with FFP is inferior to PCCs.


Asunto(s)
Factores de Coagulación Sanguínea/farmacología , Hemostáticos/farmacología , Plasma/metabolismo , Trombosis/tratamiento farmacológico , Warfarina/uso terapéutico , Lesión Pulmonar Aguda/etiología , Lesión Pulmonar Aguda/prevención & control , Adulto , Coagulación Sanguínea/efectos de los fármacos , Transfusión de Componentes Sanguíneos/efectos adversos , Velocidad del Flujo Sanguíneo , Sustitución de Medicamentos , Humanos , Relación Normalizada Internacional , Persona de Mediana Edad , Tiempo de Protrombina/métodos , Warfarina/farmacología
12.
PLoS One ; 6(4): e18272, 2011 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-21494670

RESUMEN

BACKGROUND: Xenotropic murine leukemia virus-related virus (XMRV) was recently discovered to be the first human gammaretrovirus that is associated with chronic fatigue syndrome and prostate cancer (PC). Although a mechanism for XMRV carcinogenesis is yet to be established, this virus belongs to the family of gammaretroviruses well known for their ability to induce cancer in the infected hosts. Since its original identification XMRV has been detected in several independent investigations; however, at this time significant controversy remains regarding reports of XMRV detection/prevalence in other cohorts and cell type/tissue distribution. The potential risk of human infection, coupled with the lack of knowledge about the basic biology of XMRV, warrants further research, including investigation of adaptive immune responses. To study immunogenicity in vivo, we vaccinated mice with a combination of recombinant vectors expressing codon-optimized sequences of XMRV gag and env genes and virus-like particles (VLP) that had the size and morphology of live infectious XMRV. RESULTS: Immunization elicited Env-specific binding and neutralizing antibodies (NAb) against XMRV in mice. The peak titers for ELISA-binding antibodies and NAb were 1:1024 and 1:464, respectively; however, high ELISA-binding and NAb titers were not sustained and persisted for less than three weeks after immunizations. CONCLUSIONS: Vaccine-induced XMRV Env antibody titers were transiently high, but their duration was short. The relatively rapid diminution in antibody levels may in part explain the differing prevalences reported for XMRV in various prostate cancer and chronic fatigue syndrome cohorts. The low level of immunogenicity observed in the present study may be characteristic of a natural XMRV infection in humans.


Asunto(s)
Anticuerpos Antivirales/inmunología , Formación de Anticuerpos/inmunología , Modelos Animales , Proteínas del Envoltorio Viral/inmunología , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/inmunología , Animales , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Especificidad de Anticuerpos/inmunología , Línea Celular , Vectores Genéticos/genética , Humanos , Sueros Inmunes/inmunología , Inmunización , Ratones , Pruebas de Neutralización , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/metabolismo , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/ultraestructura
13.
MLO Med Lab Obs ; 43(2): 8, 10, 12 passim; quiz 16-7, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21388025

RESUMEN

Diabetes is a devastating disease that accounts for more than $132 billion in healthcare costs annually in the U.S., and these costs are predicted to rise as high as $192 billion by the year 2020 (see recent statistics from AHRQ on page 12). For many people with diabetes, the life expectancy is shorter than that of age-matched non-diabetics. This fate is due to both the microvascular and macrovascular complications resulting from prolonged hyperglycemia. Current ADA guidelines for diagnosis include measures of plasma glucose and Alc, a glycated form of hemoglobin that has been used for many years as a marker of average glycemia. To see how Alc affects the overall number of people in the U.S. diagnosed with diabetes as a result of the test's greater practicality will be interesting. Significant progress has been made in diabetes research through the use of stem-cell technology, molecular DNA methods, and discoveries of novel insulin-controlling systems in the body. Several federally funded diabetes-research centers across the United States are currently continuing these efforts and, ultimately, hope for a cure for diabetes and its complications.


Asunto(s)
Diabetes Mellitus/diagnóstico , Guías de Práctica Clínica como Asunto , Animales , Investigación Biomédica , Diabetes Mellitus/epidemiología , Diabetes Mellitus/terapia , Modelos Animales de Enfermedad , Humanos
14.
MLO Med Lab Obs ; 43(3): 10-2, 16, 18; quiz 20, 22, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21446576

RESUMEN

In summary, the abundance of reported candidate-biomarker proteins in the scientific literature compared to the lack of those reaching clinical use indicates that the aforementioned pipeline bottleneck falls in either the verification or validation phases. To stress this point, Polanski and Anderson compiled a list of 1,261 proteins that have been cited in the literature as being differentially expressed in human cancers.¹ Of the 1,261 proteins, 22% are reported to be present in the blood and should be detectable given a sensitive enough assay. Interestingly, only 5% of these candidates have been thoroughly investigated as biomarkers (greater than 500 citations),¹ with 41 (~3%) actually being used in some clinical capacity. The reason behind so few biomarkers reaching the clinic can largely be explained by the inability of current technologies to consistently and quantitatively verify the presence of the candidates in patient samples and the failure, thus far, to identify biomarkers with high specificity for a particular disease.9 As noted above, none of the nine FDA-approved cancer biomarkers demonstrate the specificity required for diagnosis when used alone. Thus, the development of panels of proteins, such as the FDA-approved OVA1 test,57 may be crucial to achieve the specificity required for early cancer diagnosis, and is interesting to speculate that members of such panels are likely to have already been identified but not yet implemented.58


Asunto(s)
Biomarcadores , Neoplasias/diagnóstico , Biomarcadores/análisis , Detección Precoz del Cáncer , Educación Continua , Humanos , Estados Unidos
15.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(7-8): 553-6, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21300577

RESUMEN

A method for the determination of tranexamic acid (TXA) in human plasma and cerebral spinal fluid (CSF) was developed. Analyses were performed by ultra performance liquid chromatography with tandem mass spectrometry detection (UPLC-MS/MS) using ɛ-aminocaproic acid (ACA) as an internal standard. TXA and ACA were extracted from a 50 µL sample of plasma or CSF using a methanol protein crash protocol, and chromatographic separation was performed on an ACQUITY™ TQD mass spectrometer using a UPLC C18 BEH 1.7 µm column with a water and methanol gradient containing 0.1% formic acid. The detection and quantitation was performed by positive ion electrospray ionization using the multiple reaction monitoring (MRM) mode. The method was linear over the concentration range of 0.1-10.0 µg/mL, with lower limit of quantitation of 0.1 µg/mL for TXA. The intra- and inter-assay precision was less than 12% and 13% respectively at the plasma and CSF TXA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around-time. The method has been successfully applied to assess the plasma and CSF concentrations of tranexamic acid achieved with only one dosing regimen of tranexamic acid in patients undergoing cardiopulmonary bypass surgery (CPB).


Asunto(s)
Antifibrinolíticos/sangre , Antifibrinolíticos/líquido cefalorraquídeo , Puente Cardiopulmonar , Ácido Tranexámico/sangre , Ácido Tranexámico/líquido cefalorraquídeo , Antifibrinolíticos/farmacocinética , Cromatografía Líquida de Alta Presión , Hemoglobinas/análisis , Humanos , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Ácido Tranexámico/farmacocinética
16.
J Virol ; 85(9): 4547-57, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21325416

RESUMEN

Xenotropic murine leukemia-related virus (XMRV) was identified in association with human prostate cancer and chronic fatigue syndrome. To examine the infection potential, kinetics, and tissue distribution of XMRV in an animal model, we inoculated five macaques with XMRV intravenously. XMRV established a persistent, chronic disseminated infection, with low transient viremia and provirus in blood lymphocytes during acute infection. Although undetectable in blood after about a month, XMRV viremia was reactivated at 9 months, confirming the chronicity of the infection. Furthermore, XMRV Gag was detected in tissues throughout, with wide dissemination throughout the period of monitoring. Surprisingly, XMRV infection showed organ-specific cell tropism, infecting CD4 T cells in lymphoid organs including the gastrointestinal lamina propria, alveolar macrophages in lung, and epithelial/interstitial cells in other organs, including the reproductive tract. Of note, in spite of the intravenous inoculation, extensive XMRV replication was noted in prostate during acute but not chronic infection even though infected cells were still detectable by fluorescence in situ hybridization (FISH) in prostate at 5 and 9 months postinfection. Marked lymphocyte activation occurred immediately postinfection, but antigen-specific cellular responses were undetectable. Antibody responses were elicited and boosted upon reexposure, but titers decreased rapidly, suggesting low antigen stimulation over time. Our findings establish a nonhuman primate model to study XMRV replication/dissemination, transmission, pathogenesis, immune responses, and potential future therapies.


Asunto(s)
Anticuerpos Antivirales/sangre , Modelos Animales de Enfermedad , Macaca mulatta/virología , Enfermedades de los Primates/virología , Infecciones por Retroviridae/virología , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/inmunología , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/patogenicidad , Animales , Linfocitos T CD4-Positivos/virología , Enfermedad Crónica , Células Epiteliales/virología , Humanos , Linfocitos/virología , Macrófagos/virología , Masculino , Enfermedades de los Primates/inmunología , Enfermedades de los Primates/patología , Provirus/aislamiento & purificación , Infecciones por Retroviridae/inmunología , Infecciones por Retroviridae/patología , Tropismo Viral , Viremia , Activación Viral , Latencia del Virus
17.
Adv Virol ; 2011: 965689, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22312360

RESUMEN

Although XMRV dissemination in humans is a matter of debate, the prostate of select patients seem to harbor XMRV, which raises questions about its potential route of transmission. We established a model of infection in rhesus macaques inoculated with XMRV. In spite of the intravenous inoculation, all infected macaques exhibited readily detectable XMRV signal in the reproductive tract of all 4 males and 1 female during both acute and chronic infection stages. XMRV showed explosive growth in the acini of prostate during acute but not chronic infection. In seminal vesicles, epididymis, and testes, XMRV protein production was detected throughout infection in interstitial or epithelial cells. In the female monkey, epithelial cells in the cervix and vagina were also positive for XMRV gag. The ready detection of XMRV in the reproductive tract of male and female macaques infected intravenously suggests the potential for sexual transmission for XMRV.

18.
Nat Methods ; 8(1): 85-90, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21131969

RESUMEN

Major challenges of glycomics are to characterize a glycome and identify functional glycans as ligands for glycan-binding proteins (GBPs). To address these issues we developed a general strategy termed shotgun glycomics. We focus on glycosphingolipids (GSLs), a class of glycoconjugates that is challenging to study, recognized by toxins, antibodies and GBPs. We derivatized GSLs extracted from cells with a heterobifunctional fluorescent tag suitable for covalent immobilization. We separated fluorescent GSLs by multidimensional chromatography, quantified them and coupled them to glass slides to create GSL shotgun microarrays. Then we interrogated the microarrays with cholera toxin, antibodies and sera from individuals with Lyme disease to identify biologically relevant GSLs that we subsequently characterized by mass spectrometry. Shotgun glycomics incorporating GSLs and potentially glycoprotein-derived glycans is an approach for accessing the complex glycomes of animal cells and is a strategy for focusing structural analyses on functionally important glycans.


Asunto(s)
Glicómica/métodos , Glicoesfingolípidos/análisis , Glicoesfingolípidos/química , Análisis por Micromatrices/métodos , Animales , Línea Celular , Eritrocitos/química , Glicoesfingolípidos/sangre , Humanos , Enfermedad de Lyme/sangre , Estructura Molecular
19.
Thromb Res ; 127(2): 135-40, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21144556

RESUMEN

BACKGROUND: Increased levels of factor VIII occur as a response to vascular injury and/or inflammation, and may increase thrombotic risks. In contrast, factor VIII deficiency poses a major hemostatic challenge. The role of factor VIII in modulating hemostasis/thrombosis was investigated in plasma models of hypocoagulable and hypercoagulable state using thrombin generation (TG) assay. METHODS: TG was performed in undiluted/diluted control, FVIII-deficient, FVIII-deficient with low antithrombin (AT activity, ~59%), and factor XI-deficient plasma samples using relipidated tissue factor (TF, 2 pM) or dilute Actin as activators. The impact of elevated FVIII on TG was simulated by adding Humate-P (0 to 3 U/ml) to the above plasma samples. In fondaparinux (1 µg/ml) treated plasma with normal or lower AT activity effects of Humate-P vs. 60 nM of recombinant activated factor VII (rFVIIa) were also evaluated. RESULTS: Humate-P increased TG concentration dependently in undiluted and diluted control plasma with TF activation. With Actin activation, only the concentration dependent shortening of lag time, but no change in peak thrombin was observed. In FVIII-deficient, FVIII-deficient with low AT, and FXI-deficient samples, 3 U/ml of Humate-P increased TG, and decreased its onset with either activator. The reduced peak thrombin due to fondaparinux was reversed with Humate-P (3 U/ml) more than with rFVIIa. Elevated FVIII levels seem to favor intrinsic tenase formation and antagonize fondaparinux because anti-FIXa aptamer added to fondaparinux effectively attenuated TG. CONCLUSION: Elevated FVIII supports the propagation of TG via intrinsic tenase formation under low TF condition, factor XI deficiency or in the presence of fondaparinux.


Asunto(s)
Anticoagulantes/farmacología , Factor VIII/metabolismo , Deficiencia del Factor XI/sangre , Hemofilia A/sangre , Polisacáridos/farmacología , Trombina/biosíntesis , Factor VIII/farmacología , Factor VIIa/farmacología , Factor X/antagonistas & inhibidores , Fondaparinux , Humanos , Proteínas Recombinantes/farmacología , Tiempo de Coagulación de la Sangre Total , Factor de von Willebrand/metabolismo
20.
Biomark Med ; 4(6): 859-70, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21133707

RESUMEN

The advent of high-resolution mass spectrometers coupled with proteomic techniques has facilitated the discovery and characterization of novel viral proteins and the detection of virus-induced changes in the cellular proteome. These advances have enabled a more comprehensive characterization of viral interactions involved in infection and pathogenesis, and allowed the discovery of viral biomarkers. This article focuses on the role of mass spectrometry proteomic techniques to identify and characterize both prospective and verified viral biomarkers, and their implications on the diagnosis of disease.


Asunto(s)
Biomarcadores/análisis , Espectrometría de Masas/métodos , Proteómica/métodos , Virosis/diagnóstico , Biomarcadores/sangre , Biomarcadores/metabolismo , Biomarcadores/orina , Humanos , Virosis/sangre , Virosis/metabolismo , Virosis/orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA