Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Invest Ophthalmol Vis Sci ; 64(14): 23, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37975851

RESUMEN

Purpose: The purpose of this study was to describe the immunoarchitecture of normal extraocular muscles (EOMs) in terms of presence, distribution, and organization of various immune cells. Methods: We performed unilateral orbital exenterations in six fresh human cadavers from elderly patients, followed by dissection of the medial, lateral, superior and inferior rectus, superior and inferior oblique, and superior palpebral levator muscle in their entirety. We further cross sectioned each EOM in an anterior, central, and posterior third. After immunohistochemical staining for CD3, CD8, CD20, CD138, CD68, and podoplanin, quantitative analysis was performed. Results: We found all EOMs (rectus, oblique, and levator muscles) to harbor both T- and B-lymphocytes, with a B-lymphocyte dominance and an absence of plasma cells. The highest prevalence of immune cells was seen in the muscle bellies, with, on average, 488 ± 63 CD3+ T-lymphocytes and 44 ± 110 CD20+ B-lymphocytes per mm2, and significant differences from the anterior (T-lymphocytes) and posterior (T- and B-lymphocytes) thirds. T- and B-lymphocytes were primarily organized in hotspots in the vicinity of blood vessels. In addition, a small resident population of macrophages scattered throughout the specimens was detected. No lymphatic vessels were found in any of the EOMs. Conclusions: These findings can serve as a reference dataset in the assessment of EOM biopsies in the diagnostic process of inflammatory orbital and systemic disorders. Moreover, from a regenerative perspective, our results highlight the importance of taking into account the presence of a resident immune cell population when studying the host immune response on transplanted tissues or engineered constructs.


Asunto(s)
Linfocitos B , Músculos Oculomotores , Humanos , Anciano , Músculos Oculomotores/patología , Linfocitos T , Párpados , Imagen por Resonancia Magnética
2.
Ophthalmic Plast Reconstr Surg ; 39(6): e179-e182, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37405752

RESUMEN

A 35-year-old woman was treated for extensive squamous cell carcinoma of the nasal septal mucosa with total rhinectomy, including removal of the nasal septum, and chemoradiotherapy. A magnet-retained nasal prosthesis was fitted. She had developed right-sided epiphora from total proximal lacrimal canalicular obstruction, for which an angled Jones lacrimal bypass tube was inserted. The tube, however, intermittently rotated in the nasal cavity, causing recurrent epiphora and irritation at the caruncular site. With the aid of 3-dimensional technology, we designed a septum for the prosthesis that stabilized the tube within the nasal cavity. At the follow-up 2 years later, the patient was satisfied with the nasal prosthesis and lacrimal stent. To our knowledge, this report is the first to describe a patient-specific nasal prosthesis adapted for a Jones tube after total rhinectomy.


Asunto(s)
Dacriocistorrinostomía , Aparato Lagrimal , Obstrucción del Conducto Lagrimal , Femenino , Humanos , Adulto , Dacriocistorrinostomía/métodos , Aparato Lagrimal/cirugía , Prótesis e Implantes , Impresión Tridimensional
3.
Surv Ophthalmol ; 68(2): 265-279, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36372115

RESUMEN

In the management of orbital disorders and defects, minimally invasive surgical approaches have become increasingly efficient for their reduction of operative trauma and access without compromise of therapeutic benefit or diagnostic yield. Various approaches have focused on bone- and canthal-sparing techniques and concealed and small skin incisions. We review the current state of knowledge of procedures to enter the orbit via the conjunctiva. Any quadrant of the orbit can be accessed via the conjunctiva. Surgical incisions involve the orbital palpebral, forniceal, and bulbar conjunctiva. According to the location, nature, and size of the lesion, the transconjunctival orbitotomy can be used as a single procedure, in combination with a caruncular approach or as an adjunct in a multidisciplinary procedure for lesions extending deep into or outside the orbit. The working space and field of operating view can be expanded by releasing the horizontal tension of the eyelid with a lateral cantholysis, lateral paracanthal blepharotomy, or medial lid split procedure. Complications related to the conjunctival incision are reduced to dry eye disease.


Asunto(s)
Conjuntiva , Enfermedades Orbitales , Humanos , Conjuntiva/cirugía , Párpados/cirugía , Párpados/patología , Órbita/cirugía , Enfermedades Orbitales/cirugía , Enfermedades Orbitales/patología , Estudios Retrospectivos
4.
Orbit ; 42(4): 383-388, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35924421

RESUMEN

AIM: To study the impact of the prosthesis motility on the Quality of Life (QoL) in anophthalmic patients. METHODS: Cross-sectional, observational study of 100 anophthalmic patients, of whom 64% had an acryl implant, 6% an Allen implant, 1% a hydroxyapatite implant, 4% a dermis fat graft, 16% no implant, and 9% an unknown implant. We quantitatively assessed the motility of the prosthesis with Kestenbaum glasses and the QoL with a validated questionnaire covering five domains: General functional abilities and care, wearing comfort, physical appearance, psychological and social functioning. Associations between measured prosthetic eye motility, patient-perceived motility, and satisfaction were made. RESULTS: Motility of the prosthesis was impaired with an average loss of 76%, and correlated with Cosmetic satisfaction (adduction P = .02, abduction P = .008, elevation P = .04) and Social satisfaction (adduction P = .03, abduction P = .003). The patient-perceived motility of the prosthesis correlated with General functioning abilities (horizontal P = .0004, vertical P = .0004), Comfort (horizontal P = .001, vertical P = .003), Cosmetic satisfaction (horizontal P = .0002, vertical P = .0002), Psychological satisfaction (horizontal P = .001, vertical P = .001), and Social satisfaction (horizontal P = .002, vertical P = .003). CONCLUSIONS: Ocular prosthetic motility has a significant impact on patient-perceived satisfaction and physical appearance, and predicts coping with the prosthetic condition on the psychosocial level. This highlights the need of introducing patient-reported outcome measures in the prosthetic rehabilitation of the anophthalmic patient.


Asunto(s)
Anoftalmos , Ojo Artificial , Humanos , Calidad de Vida , Estudios Transversales , Anoftalmos/cirugía , Implantación de Prótesis
5.
Eur Thyroid J ; 11(6)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36479875

RESUMEN

Thyroid eye disease (TED) remains challenging for clinicians to evaluate and manage. Novel therapies have recently emerged, and their specific roles are still being determined. Most patients with TED develop eye manifestations while being treated for hyperthyroidism and under the care of endocrinologists. Endocrinologists, therefore, have a key role in diagnosis, initial management, and selection of patients who require referral to specialist care. Given that the need for guidance to endocrinologists charged with meeting the needs of patients with TED transcends national borders, and to maximize an international exchange of knowledge and practices, the American Thyroid Association and European Thyroid Association joined forces to produce this Consensus Statement.

6.
Thyroid ; 32(12): 1439-1470, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36480280

RESUMEN

Thyroid eye disease (TED) remains challenging for clinicians to evaluate and manage. Novel therapies have recently emerged, and their specific roles are still being determined. Most patients with TED develop eye manifestations while being treated for hyperthyroidism and under the care of endocrinologists. Endocrinologists, therefore, have a key role in diagnosis, initial management, and selection of patients who require referral to specialist care. Given that the need for guidance to endocrinologists charged with meeting the needs of patients with TED transcends national borders, and to maximize an international exchange of knowledge and practices, the American Thyroid Association and European Thyroid Association joined forces to produce this consensus statement.


Asunto(s)
Oftalmopatía de Graves , Hipertiroidismo , Humanos , Consenso , Oftalmopatía de Graves/diagnóstico , Oftalmopatía de Graves/terapia , Hipertiroidismo/diagnóstico , Hipertiroidismo/terapia , Estados Unidos , Europa (Continente)
7.
Curr Rheumatol Rep ; 24(1): 20-26, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-35138592

RESUMEN

PURPOSE OF REVIEW: To review current knowledge regarding idiopathic orbital myositis. RECENT FINDINGS: Recent publications have focused on possible causes of orbital myositis and the process to reach a diagnosis of idiopathic orbital myositis. With inflamed and enlarged extraocular muscles, features to distinguish between competing diagnostic possibilities are based on imaging in the context of history and clinical signs. Idiopathic orbital myositis is characterized by the clinical triad of acute onset of orbital pain exacerbated on eye movement, double vision, and redness or swelling of the eyelids or conjunctiva, along with the radiological finding of homogeneous, fusiform enlargement of one or more extraocular muscles. In atypical or inconclusive clinico-radiological findings for a diagnosis of idiopathic orbital myositis, or where the clinical behavior changes or fails to respond to corticosteroid treatment, a systemic and oncologic work-up and muscle biopsy are warranted to exclude specific local or systemic disease as cause of the inflamed and enlarged muscle. As our understanding of idiopathic orbital myositis evolves, the diagnostic focus is shifting toward earlier identification of underlying local or systemic disease through systemic work-up and muscle biopsy.


Asunto(s)
Miositis , Miositis Orbitaria , Biopsia , Humanos , Miositis/diagnóstico por imagen , Miositis/patología , Músculos Oculomotores/diagnóstico por imagen , Músculos Oculomotores/patología , Miositis Orbitaria/diagnóstico por imagen , Miositis Orbitaria/tratamiento farmacológico
8.
Graefes Arch Clin Exp Ophthalmol ; 259(7): 2017-2025, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33547966

RESUMEN

PURPOSE: In patients with an anophthalmic condition, the primary determinants of success of ocular prosthetic rehabilitation are satisfaction with care and quality of life (QoL). The aim of this study is to develop a condition-specific questionnaire as a patient-reported outcome measure for patients with an ocular prosthesis. METHODS: Observational cross-sectional prospective study. We included 100 patients (52 female, 48 male, > 18 years old) with an anophthalmic and ocular prosthetic condition existing for 2 years or more. The patients completed a pre-tested 72-item questionnaire regarding their experience on living with an ocular prosthesis in four domains of QoL: single vision and care, wearing comfort, physical appearance and motility, and psychosocial functioning. Associations with demographic factors and condition- and prosthesis-related variables were investigated with multivariate analysis. The questionnaire was reduced with principal component analysis to obtain the Global Ocular Prosthesis Score (GOPS). RESULTS: Satisfaction scores for each QoL domain were high with a mean visual analogue score between 7.2 and 7.6. Patients were generally satisfied with the physical appearance of the artificial eye and reported adequate psychosocial functioning. Patients described the reduced peripheral visual field and socket discharge as chief complaints. The test was reduced to a 20-item questionnaire. The mean GOPS was 70.87 (median 75.00). CONCLUSIONS: Patients with longstanding ocular prosthetic wear are satisfied with their physical appearance and report adequate psychosocial functioning. A concise 20-item questionnaire for the anophthalmic condition is a valuable tool to quantitatively measure patient-reported outcome of ocular prosthetic rehabilitation. TRIAL REGISTRATION NUMBER: NCT04321382, 03/2020, retrospectively registered.


Asunto(s)
Anoftalmos , Ojo Artificial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida
9.
Neuroradiology ; 63(5): 817-820, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33410947

RESUMEN

A 39-year-old woman presented with sudden onset of double vision, right upper eyelid swelling and ptosis, and orbital pain. Imaging revealed an irregular mass of the upper right orbit with central non-enhancing areas. Upon inquiry, the patient recalled an intraorbital trauma with a crayon in her childhood, 35 years ago. Via translid anterior orbitotomy, remnants of a blue crayon embedded in an orbital fat mass were removed. Histopathology showed scavenger reaction of macrophages and sclerosis. Energy-dispersive X-ray spectroscopy revealed the presence of silicate particles. Repeated courses of corticosteroids were given. The patient deteriorated with reduced vision and frozen globe owing to severe orbital fibrosis of the entire orbit.


Asunto(s)
Órbita , Enfermedades Orbitales , Adulto , Niño , Femenino , Fibrosis , Humanos , Inflamación/diagnóstico por imagen , Órbita/diagnóstico por imagen , Órbita/patología , Enfermedades Orbitales/diagnóstico por imagen , Enfermedades Orbitales/etiología , Esclerosis/patología
10.
Acta Ophthalmol ; 99(2): 221-226, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32701212

RESUMEN

PURPOSE: Fitting a customized ocular prosthesis for anophthalmic patients entails an artisanal labour-exhausting process and is standardly based on impression moulding of the socket, which may be anatomically inaccurate. The objective of the study was to design an impression-free socket mould with three-dimensional (3D) technology. METHODS: The ex vivo anophthalmic socket models included one silicone, one fresh pig cadaver head and three fresh-frozen human cadaver heads. After intra-socket application with iodine substance, five observers obtained eighteen low-dose cone beam computed tomography (CBCT) scans and one observer one high-dose CBCT scan of each model. The observers designed non-impression 3D moulds of the socket with 3D software. For the human cadaver sockets 3D geometric models of the ocular prosthesis were rendered from the 3D mould of the socket and the mirrored cornea of the contralateral eye. RESULTS: The posterior surface of the 3D mould was highly accurate, with a mean absolute deviation of 0.28 mm, 0.53 mm, 0.37 mm and mean upper deviation of 0.53 mm, 0.86 mm, 1.17 mm, respectively, for the phantom, pig and human model. The intra- and interobserver repeatability and reproducibility of the 3D moulds and designs was good (<0.35 mm). The largest variation in the 3D geometric model was found at the junction of the 3D mould and mirrored cornea. CONCLUSION: 3D design of an impression-free geometric model for an ocular prosthesis with low-dose CBCT is highly accurate in ex vivo anophthalmic socket models. This novel method is a critical step towards the manufacturing of 3D printed ocular prostheses and requires validation in anophthalmic patients.


Asunto(s)
Anoftalmos/cirugía , Enucleación del Ojo , Ojo Artificial , Impresión Tridimensional , Animales , Modelos Animales de Enfermedad , Humanos , Masculino , Diseño de Prótesis , Reproducibilidad de los Resultados , Porcinos
11.
Ophthalmic Plast Reconstr Surg ; 37(3S): S19-S22, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33009327

RESUMEN

PURPOSE: To report the etiology, management, and possible risk factors for diplopia after canalicular bypass surgery. METHODS: A multicenter retrospective, noncomparative case series of patients who developed diplopia following canalicular bypass surgery were assessed. RESULTS: Twenty-four cases of diplopia were identified across 12 institutions. Tubes were inserted as a primary procedure with external dacryocystorhinostomy (DCR) (1; 4%) or without DCR (10; 42%) or as a secondary procedure after external (8; 33%) or endonasal (5; 21%) DCR. Factors predisposing to local damage were noted in 17 (71%): these factors included preexisting autoimmune/inflammatory condition (7 cases), medial canthal tumor resection (5 cases), preoperative radiotherapy (2 cases), 2 drug treatments (topical and systemic), and 1 local surgery. Horizontal diplopia was due to restriction of abduction and first noted at a median of 3.5 months (mean: 17.8 months, range: 1 day to 112 months) and persisted in 23 (96%) cases with a mean restriction of -2, affecting primary gaze in 4 patients and activities of daily living in 13 (42%). Seventeen patients received various treatments: 10 were operated on resulting in cure in 1 and improvement in 9. A stable degree of diplopia persisted in all but one patient. CONCLUSIONS: Restriction of abduction causing horizontal diplopia is a rare complication with canalicular bypass surgery and a notably high proportion occurred after tube placement without DCR; carunculectomy was not ubiquitous. Although in some the diplopia may be improved with intervention, the chance of cure is low. This complication should probably be included during informed consent for canalicular bypass tubes.


Asunto(s)
Dacriocistorrinostomía , Obstrucción del Conducto Lagrimal , Conducto Nasolagrimal , Actividades Cotidianas , Diplopía/etiología , Humanos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
12.
Eye (Lond) ; 35(7): 1909-1914, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32929179

RESUMEN

BACKGROUND: Following removal of the eye, soft tissue changes of the eyelids and orbit may develop into an anophthalmic socket (AS) syndrome, which is often attributed to orbital volume deficiency. While adequate primary orbital volume replacement is nowadays standard of care, patients may still present with facial asymmetry. The aim of this study is to provide insights into these changes and their impact on patient quality of life (QoL). METHODS: Cross-sectional study of 59 patients with longstanding ocular prosthetic wear after enucleation or evisceration surgery. The alignment, function, and laxity of the eyelids of the anophthalmic side were compared to those of the fellow side. The QoL was assessed with a 4-item questionnaire specific for the prosthetic condition. The different aspects of AS syndrome were analysed in relation to disease-specific and prosthetic data and to the patient QoL scores. RESULTS: Clinical AS syndrome was prevalent in 53% of patients with acquired anophthalmia. The anophthalmic side was statistically significantly different from the fellow side for the known AS syndrome features such as superior sulcus depression, margin reflex distance 1, and enophthalmia, but also for new features such as levator muscle function and lagophthalmia (P < 0.05). The difference was correlated with duration of prosthetic wear, prior orbital radiotherapy, and size of the prosthesis (P < 0.05). QoL scores were not correlated to the separate features of AS syndrome, except for a positive correlation between wearing comfort of the prosthesis and upper eyelid ptosis (P < 0.05). CONCLUSION: Patients with an ocular prosthesis show a relatively high prevalence of one or more distinct clinical features of AS syndrome, which do not negatively affect patient QoL. These findings underscore the importance to tailor prosthetic and surgical treatment to the patient's perceived QoL rather than to the objective clinical findings.


Asunto(s)
Anoftalmos , Implantes Orbitales , Anoftalmos/epidemiología , Anoftalmos/cirugía , Estudios Transversales , Enucleación del Ojo , Ojo Artificial , Humanos , Órbita , Prevalencia , Calidad de Vida
13.
Ophthalmic Plast Reconstr Surg ; 37(3S): S162-S164, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32991495

RESUMEN

Amid the global coronavirus disease 2019 (COVID-19) outbreak, an 89-year-old male with chronic kidney disease presented with acute dacryocystitis and a persistent dry cough. After a course of antibiotics, external dacryocystorhinostomy was performed under local anesthesia without sedation. During planned hemodialysis in the early hours after the procedure, the patient developed nausea and hematemesis followed by severe dyspnea and hypoxemia. The patient was diagnosed with aspiration pneumonia, a previously unreported complication in lacrimal surgery.


Asunto(s)
COVID-19 , Dacriocistitis , Dacriocistorrinostomía , Neumonía por Aspiración , Anciano de 80 o más Años , Anestesia Local/efectos adversos , Dacriocistitis/diagnóstico , Dacriocistitis/etiología , Dacriocistitis/cirugía , Humanos , Masculino , SARS-CoV-2
14.
Graefes Arch Clin Exp Ophthalmol ; 258(7): 1527-1532, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32140924

RESUMEN

PURPOSE: Current methods to analyse the globe position, including Hertel exophthalmometry and computed tomography (CT), are limited to the axial plane and require the lateral orbital rim and cornea as landmarks. This pilot study aimed to design a method to measure the position of the globe in the axial, coronal and sagittal plane and independent from orbital bony and corneal references. METHODS: With the aid of three-dimensional CT reconstruction technology, we determined the globe position in the orbit based on the centre of the globe. Method validation was performed using data of consecutive orbital CT scans from the control group and from the patients with Graves' orbitopathy who underwent orbital decompression surgery with removal of the lateral orbital margin. RESULTS: The inter- and intra-observer reliability was excellent with a high intraclass correlation coefficient (> 0.99, 95% CI [0.97; 1.00]). In the decompressed orbits, there was a statistically significant globe position shift along the anterior-posterior axis (P = 0.0005, 95% CI [0.63; 3.66]), but not along the medial-lateral and superior-inferior axis. CONCLUSION: The 3D CT method can accurately and reliably characterise the globe position shift in the three dimensions without using orbital and corneal anatomical landmarks. The method can be useful to determine the globe shift in proptosis, enophthalmos, hypoglobus and hyperglobus, even in the presence of strabismus and orbital bone defects.


Asunto(s)
Imagenología Tridimensional/métodos , Órbita/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Curva ROC , Estudios Retrospectivos
16.
Ophthalmic Plast Reconstr Surg ; 36(4): 385-389, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31917766

RESUMEN

PURPOSE: Intravenous antibiotic prophylaxis is used for many clean-contaminated surgeries or clean surgeries with an implant, but its value for clean orbital surgery has not been determined. This study investigated infection risks and adverse effects related to antibiotics in patients undergoing orbital surgery. METHODS: A prospective, nonrandomized comparative case series of all patients undergoing orbital surgery with participating surgeons between October 1, 2013, and March 1, 2015. Types of surgery, antibiotic regimens, corticosteroid use, antibiotic side effects, and surgical site infections (SSIs) were entered into an electronic database and subsequently analyzed. Cases in which patients received postoperative oral antibiotics were analyzed separately. RESULTS: Of 1,250 consecutive orbital surgeries, 1,225 met inclusion criteria. A total of 1208 patients were included in the primary analysis: 603 received no antibiotic prophylaxis (group A), and 605 received a single dose of intravenous antibiotic (group B). Five patients (0.42%) developed an SSI, 3 in group A and 2 in group B. The difference in SSI rates was not statistically significant between the 2 groups (p = 0.66). Antibiotic prophylaxis, alloplastic implants, paranasal sinus entry, and corticosteroid use were not associated with differences in SSI rates. All SSIs resolved on a single course of oral antibiotics; an implant was removed in 1 case. There were no complications associated with a single dose of intravenous prophylaxis. However, 12% of 17 patients (group C) who received 1 week of oral postoperative prophylactic antibiotics developed antibiotic-related complications (diarrhea, renal injury), yielding a number needed to harm of 8.5. CONCLUSIONS: In this large series, antibiotic prophylaxis does not appear to have reduced the already low incidence of SSI following orbital surgery. Given the detriments of systemic antibiotics, the rarity of infections related to orbital surgery, and the efficacy of treating such infections should they occur, patients undergoing orbital surgery should be educated to the early symptoms of postoperative infection and followed closely, but do not routinely require perioperative antibiotics.


Asunto(s)
Profilaxis Antibiótica , Infección de la Herida Quirúrgica , Antibacterianos/uso terapéutico , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Infección de la Herida Quirúrgica/prevención & control
17.
Curr Opin Ophthalmol ; 30(5): 372-379, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31261186

RESUMEN

PURPOSE OF REVIEW: To comprehensively review the applications of advanced three-dimensional printing technology in the management of orbital abnormalities. RECENT FINDINGS: Three-dimensional printing has added value in the preoperative planning and manufacturing of patient-specific implants and surgical guides in the reconstruction of orbital trauma, congenital defects and tumor resection. In view of the costs and time, it is reserved as strategy for large and complex craniofacial cases, in particular those including the bony contour. There is anecdotal evidence of a benefit of three-dimensional printing in the manufacturing of prostheses for the exenterated and anophthalmic socket, and in the fabrication of patient-specific boluses, applicators and shielding devices for orbital radiation therapy. In addition, three-dimensional printed healthy and diseased orbits as phantom tangible models may augment the teaching and learning process of orbital surgery. SUMMARY: Three-dimensional printing allows precision treatment tailored to the unique orbital anatomy of the patient. Advancement in technology and further research are required to support its wider use in orbital clinical practice.


Asunto(s)
Enfermedades Orbitales/cirugía , Implantes Orbitales , Impresión Tridimensional , Humanos , Procedimientos Quirúrgicos Oftalmológicos/métodos
18.
Surv Ophthalmol ; 64(6): 741-756, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31276737

RESUMEN

The orbit can harbor mass lesions of various cellular origins. The symptoms vary considerably according to the nature, location, and extent of the disease and include common signs of proptosis, globe displacement, eyelid swelling, and restricted eye motility. Although radiological imaging tools are improving, with each imaging pattern having its own differential diagnosis, orbital mass lesions often pose a diagnostic challenge. To provide an accurate, specific, and sufficiently comprehensive diagnosis, to optimize clinical management and estimate prognosis, pathological examination of a tissue biopsy is essential. Diagnostic orbital tissue biopsy is obtained through a minimally invasive orbitotomy procedure or, in selected cases, fine needle aspiration. The outcome of successful biopsy, however, is centered on its representativeness, processing, and interpretation. Owing to the often small volume of the orbital biopsies, artifacts in the specimens should be limited by careful peroperative tissue handling, fixation, processing, and storage. Some orbital lesions can be characterized on the basis of cytomorphology alone, whereas others need ancillary molecular testing to render the most reliable diagnosis of therapeutic, prognostic, and predictive value. Herein, we review the diagnostic algorithm for orbital mass lesions, using clinical, radiological, and pathological recommendations, and discuss the methods and potential pitfalls in orbital tissue biopsy acquisition and analysis.


Asunto(s)
Neoplasias Orbitales/diagnóstico , Biopsia con Aguja Fina , Diagnóstico Diferencial , Humanos , Neoplasias Orbitales/diagnóstico por imagen , Neoplasias Orbitales/patología
19.
Eye (Lond) ; 33(7): 1158-1160, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30837709

RESUMEN

PURPOSE: To report the customized approach of patients with anophthalmia or microphthalmia with bespoke ocular prosthesis. METHODS: Retrospective analysis of case series. RESULTS: The study included cases with anophthalmia with upper eyelid deformity (one patient), microphthalmia and contralateral corectopia (one patient), microphthalmia with contralateral corneal graft (one patient), and congenital clinical anophthalmia with contralateral sclerocornea (one patient). Using techniques of embedded autologous hair and coating of adhesive pigment emulsion in the ocular prosthesis, the physical appearance of, respectively, an upper eyelid, corectopia, corneal graft, and sclerocornea was reproduced. CONCLUSION: Tailoring the ocular prosthesis to the distinct condition of the anophthalmic socket and contralateral eye adds to the success of rehabilitative prosthetic treatment of the patient.


Asunto(s)
Anoftalmos/cirugía , Ojo Artificial , Microftalmía/cirugía , Adulto , Anciano , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Diseño de Prótesis
20.
Br J Ophthalmol ; 103(9): 1248-1252, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30396885

RESUMEN

BACKGROUND/AIMS: Although a Jones tube is considered the mainstay for epiphora in patients with total blockage of the canalicular system, it has been discouraged in children for reasons of inadequate self-care and maintenance. The purpose of this study is to compare the long-term outcome of Jones tube surgery in paediatric versus adult patients. METHODS: Retrospective, interventional case series of a single academic institution. The medical records of all children (≤16 years old) and adults (>16 years old) who underwent conjunctivorhinostomy with placement of a 130° angled extended Jones tube were reviewed. The outcome measures were patency and anatomical position of the tube, type and frequency of complications and subjective relief of epiphora. RESULTS: The study included 10 children (11 eyes) (range, 5.1-16.0 years old) and 102 adults (127 eyes) (range, 19.7-82.4 years old). The success and complication rate did not differ between the two age groups. Tube dislodgement and obstruction occurred in 4 (36.4%) of the paediatric tubes with an incidence rate of 6.1%/year and in 47 (37.0%) of the adult tubes with an incidence rate of 9.3%/year (p=0.3867). Two adults required routine self-irrigation of the tube. The median follow-up was 6.7 years for the children and 8.7 years for the adults (p=0.3430). CONCLUSION: With a similar outcome profile and minimal self-care, young age is not a prognostic nor limiting factor for surgery with angled Jones tubes. Exchange with tubes of a longer length is not required during growth.


Asunto(s)
Dacriocistorrinostomía/métodos , Intubación/métodos , Obstrucción del Conducto Lagrimal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...