Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Chim Acta ; 487: 241-249, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30292631

RESUMEN

BACKGROUND: Reference measurement procedures (RMP) have rigorous accuracy specifications. For total 25-hydroxyvitamin D, 25(OH)D, bias ≤1.7% and CV ≤5% are recommended. These quality specifications are impractical for minor analytes, such as 25(OH)D2. Furthermore, documentation on RMP quality performance specifications for the individual 25(OH)D metabolites and their daily application are missing. METHODS: To assess accuracy, we used zeta-scores. Daily, 5-10 specimens (duplicate) and 3 reference materials (singleton or duplicate) were measured for 25(OH)D3 and 25(OH)D2 using JCTLM-accepted LC-MS/MS RMPs. Protocols were repeated on 3-4 occasions to generate campaign results. We used separate zeta-score acceptability criteria for daily (≤|2|) and campaign (≤|1|) evaluations. Allowable imprecision was determined experimentally. RESULTS: Across 7 campaigns, unacceptable daily zeta-scores required repeating 2 runs for 25(OH)D3 and 5 runs for 25(OH)D2. Hence, the zeta-scores of acceptable reference material results indicated high accuracy. The allowable imprecision for the RMPs was ≤5% (daily) and ≤ 3% (campaign) for 25(OH)D3 and ≤ 7% (daily) and ≤ 4% (campaign) for 25(OH)D2, respectively. CONCLUSIONS: Using zeta-scores and experimentally derived imprecision, we developed a straightforward approach to assess the acceptability of individual 25(OH)D reference measurements, providing also much-needed practical accuracy specifications for 25(OH)D2.


Asunto(s)
25-Hidroxivitamina D 2/sangre , Calcifediol/sangre , Cromatografía Liquida/normas , Humanos , Estándares de Referencia , Espectrometría de Masas en Tándem/normas
3.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-24187941

RESUMEN

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Asunto(s)
Análisis Químico de la Sangre/normas , Metabolómica/normas , Adulto , Aminoácidos/sangre , Biomarcadores/sangre , Carotenoides/sangre , Ácidos Grasos/sangre , Femenino , Humanos , Masculino , National Institutes of Health (U.S.) , Estándares de Referencia , Estados Unidos , Vitaminas/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA