Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Eur Heart J Case Rep ; 8(3): ytae097, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38454958

RESUMEN

Background: Unicuspid aortic valve (UAV) is a rare valvular heart disease and a challenging diagnosis. Advanced imaging techniques, particularly cardiac computed tomography (CT), appear to be invaluable tools to correctly identify this disease pre-operatively, as this may have an impact on the optimal surgical treatment. Case summary: We describe the case of a young patient admitted with heart failure, due to a severely stenotic UAV. Cardiac CT allowed adjusting the imaging plane to the best view in two orthogonal planes to identify the top of the 'dome' and to accurately measure the smallest valve opening by planimetry. Surgical inspection confirmed a rare case of acommissural UAV. Discussion: Cardiac CT angiography is crucial to understand the complexity of UAV disease and to differentiate the acommissural from the unicommissural type. Accurate positioning of the imaging plane through the smallest valve opening in systole reduces the risk of missing the diagnosis of this rare disease.

2.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-35583290

RESUMEN

OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.


Asunto(s)
Aneurisma de la Aorta , Insuficiencia de la Válvula Aórtica , Anuloplastia de la Válvula Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/efectos adversos , Aneurisma de la Aorta/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Reoperación/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Retrospectivos
3.
Echocardiography ; 39(6): 783-793, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35536700

RESUMEN

OBJECTIVES: To determine the 4D Flow Cardiac Magnetic Resonance (CMR) thresholds that achieve the best agreement with transthoracic echocardiography (TTE) for grading mitral regurgitation (MR). METHODS: We conducted a single-center prospective study of patients evaluated for chronic primary MR in 2016-2020. MR was evaluated blindly by TTE and 4D Flow CMR, respectively by two cardiologists and two radiologists with decades of experience. MR was graded with both methods as mild, moderate, or severe. 4D Flow CMR measurements included MR regurgitant volume per beat (RV) and mitral anterograde flow per beat (MF). RF was obtained as the ratio RV/MF. Additionally, MF was compared to left ventricular stroke volume (LVSV) by cine-CMR. RESULTS: We included 33 patients in the initial cohort and 33 in the validation cohort. Inter-observer agreement was excellent for 4D Flow CMR ICC = .94 (95% CI, .86-.97, p < 0.0001). Using recommended TTE thresholds (30 ml, 60 ml, 30%, 50%), agreement was moderate for RV and RF. The best agreement between 4D Flow CMR and TTE was obtained with CMR thresholds of 20 and 40 ml for RV (κ = .93; 95% CI, .8-1) and 20% and 37% for RF (κ = .90; 95% CI, .7-.9). In the validation cohort, agreement between TTE and 4D Flow CMR was good with the optimal thresholds (κ = .78; 95% CI, .61-.94). CONCLUSION: We propose CMR thresholds that provide a good agreement between TTE and CMR for grading MR. Further studies are needed to fully validate 4D-Flow CMR accuracy for primary MR quantification.


Asunto(s)
Insuficiencia de la Válvula Mitral , Ecocardiografía/métodos , Humanos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
4.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35438171

RESUMEN

OBJECTIVES: We investigated whether aortic valve fenestrations (respected or fixed) represent a factor associated with recurrent aortic insufficiency or reoperation after repair. METHODS: Between 2003 and 2019, patients who underwent aortic valve repair were included. Aortic insufficiency phenotypes were root aneurysm (repair: root remodelling + annuloplasty), ascending aorta aneurysm (repair: tubular aortic replacement + annuloplasty) and isolated regurgitation (repair: single/double annuloplasty). Fenestrations were either respected or fixed according to their features. RESULTS: A total of 618 patients (out of 798 operated on; 77.4%) had their valve repaired, with 167 cases of fenestrations (128 were respected, 39 fixed-32 with a patch, 6 with running suture and 1 with both). After conducting propensity score matching between no-fenestration (n = 167) and fenestration groups (n = 167), respectively, we noted the following: survival [90.3% (n = 7 deaths) vs 95.8% (n = 4)], cumulative incidence of reoperation [6.7% (n = 7) vs 5.2% (n = 4)], aortic insufficiency grade ≥ 3 [6.4% (n = 6) vs 4.4% (n = 4)] and grade ≥ 2 [28.9% (n = 28) vs 37.1% (n = 35)] were similar at 9 years [P = 0.94; median follow-up: 2.2, interquartile range: (0.8, 5.8)], whether fenestration was respected (P = 0.55) or fixed (P = 0.6, at 6 years). Standardization of the surgical approach (consisting of double annuloplasty in isolated regurgitation phenotype and expansible subvalvular annuloplasty with effective height assessment with remodelling repair for root aneurysm phenotype) reduced the risk of reoperation (era before standardization: hazard ratio: 5.4, 95% confidence interval: 1.9-15.7, P = 0.002). CONCLUSIONS: Fenestration, respected or fixed, is not a factor associated with reoperation or recurrence of significant aortic insufficiency after valve repair if the surgical approach is standardized.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Anuloplastia de la Válvula Cardíaca , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Humanos , Reoperación , Respeto , Resultado del Tratamiento
5.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-35165701

RESUMEN

OBJECTIVES: This study was undertaken to analyse outcomes of aortic valve repair using additional material and compare the results to those of cusp repair without the use of the pericardial patch. METHODS: All consecutive patients aged over 16 who underwent aortic valve repair with external ring annuloplasty for isolated aortic insufficiency, aortic insufficiency and tubular aortic aneurysm or aortic root aneurysm between May 2003 and November 2019 were included in a cohort study. Data were collected and analysed from the AVIATOR registry (AorticValve repair InternATiOnal Registry). Propensity score framework analysis (inverse probability of treatment weighting) was used to compare outcomes of the groups while controlling for confounders. RESULTS: During the 16-year study period, 618 patients underwent aortic valve repair. Eight-year survival rate was 92% in the patch group and 90.2% in the no patch group without significant differences [P = 0.957 inverse probability of treatment weighting (IPTW) weighted]. Early valve-related reoperation was more frequent in the patch group as compared to the no patch group (6% vs 1%, P < 0.001 IPTW weighted), the freedom from aortic valve-related reintervention and from structural valve deterioration at 8 years was not significantly different between the patch and no patch groups (93.7% vs 94%, P = 0.968 IPTW weighted; and 99.3% vs 96.7%, P = 0.964 IPTW weighted). CONCLUSIONS: Although a higher rate of early reintervention was observed, aortic valve repair using the pericardial patch, in a standardized approach using external annuloplasty, with effective coaptation height of at least 9 mm, was not associated with an increase in mid-term aortic valve-related reoperation or structural valve deterioration as compared to valve repair without the pericardial patch.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Anuloplastia de la Válvula Cardíaca , Anciano , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Estudios de Cohortes , Humanos , Reoperación , Resultado del Tratamiento
6.
J Am Coll Cardiol ; 78(22): 2131-2143, 2021 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-34823655

RESUMEN

BACKGROUND: There were gaps between guidelines and practice when surgery was the only treatment for aortic stenosis (AS). OBJECTIVES: This study analyzed the decision to intervene in patients with severe AS in the EORP VHD (EURObservational Research Programme Valvular Heart Disease) II survey. METHODS: Among 2,152 patients with severe AS, 1,271 patients with high-gradient AS who were symptomatic fulfilled a Class I recommendation for intervention according to the 2012 European Society of Cardiology guidelines; the primary end point was the decision for intervention. RESULTS: A decision not to intervene was taken in 262 patients (20.6%). In multivariate analysis, the decision not to intervene was associated with older age (odds ratio [OR]: 1.34 per 10-year increase; 95% CI: 1.11 to 1.61; P = 0.002), New York Heart Association functional classes I and II versus III (OR: 1.63; 95% CI: 1.16 to 2.30; P = 0.005), higher age-adjusted Charlson comorbidity index (OR: 1.09 per 1-point increase; 95% CI: 1.01 to 1.17; P = 0.03), and a lower transaortic mean gradient (OR: 0.81 per 10-mm Hg decrease; 95% CI: 0.71 to 0.92; P < 0.001). During the study period, 346 patients (40.2%, median age 84 years, median EuroSCORE II [European System for Cardiac Operative Risk Evaluation II] 3.1%) underwent transcatheter intervention and 515 (59.8%, median age 69 years, median EuroSCORE II 1.5%) underwent surgery. A decision not to intervene versus intervention was associated with lower 6-month survival (87.4%; 95% CI: 82.0 to 91.3 vs 94.6%; 95% CI: 92.8 to 95.9; P < 0.001). CONCLUSIONS: A decision not to intervene was taken in 1 in 5 patients with severe symptomatic AS despite a Class I recommendation for intervention and the decision was particularly associated with older age and combined comorbidities. Transcatheter intervention was extensively used in octogenarians.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Toma de Decisiones Clínicas , Manejo de la Enfermedad , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Ecocardiografía , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Morbilidad/tendencias , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
7.
J Cardiovasc Surg (Torino) ; 62(1): 12-18, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33185078

RESUMEN

Standardization of aortic valve repair techniques with use of a calibrated annuloplasty have led to improved long-term outcomes in dystrophic aortic insufficiency. It can also improve dissemination of techniques and rates of aortic valve repair. Dystrophic aortic insufficiency can be found in three aortic phenotypes: dilated aortic root, dilated ascending aorta and isolated aortic insufficiency. The aortic annulus is invariably dilated above 25 mm in the vast majority of cases of aortic insufficiency, regardless of whether the aorta is dilated or not. A dilated annulus is a risk factor for late failure of aortic valve repair if not addressed at the time of surgery. We perform a calibrated annuloplasty at both sub- and supra-valvular levels in order to restore the ratio of sinotubular junction and annulus. Current evidence shows aortic valve repair reduces valve-related mortality compared to prosthetic valve replacement, with an improved quality of life.


Asunto(s)
Aneurisma de la Aorta/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Anuloplastia de la Válvula Cardíaca/efectos adversos , Anuloplastia de la Válvula Cardíaca/instrumentación , Anuloplastia de la Válvula Cardíaca/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Calidad de Vida , Recuperación de la Función , Factores de Riesgo , Resultado del Tratamiento
8.
Ann Cardiothorac Surg ; 8(3): 331-341, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31240177

RESUMEN

Aortic valve (AV) repair is the preferred surgical treatment in young patients with aortic regurgitation (AR) and/or proximal aorta aneurysm, as noted in the recent European Society of Cardiology (ESC) guidelines. However, this surgical option is still underused in clinical practice. This emphasizes the need to build a heart team dedicated to AV repair with expert surgeons and echocardiographers. Surgical techniques are now standardized in their approaches to enhance the reproducibility and expansion of AV repair. The objective of this keynote is to also demonstrate the need for a standardized pre-pump intra-operative echocardiography protocol to fulfill surgeon's needs in providing a road map and predicting techniques to be used for an effective and durable repair.

9.
ESC Heart Fail ; 6(4): 649-657, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31115164

RESUMEN

AIMS: Cardiac fibrosis is associated with left ventricular (LV) remodelling and contractile dysfunction in aortic stenosis (AS). The fibrotic process in this condition is still unclear. The aim of this study was to determine the role of both local and systemic inflammation as underlying mechanisms of LV fibrosis and contractile dysfunction. The diagnostic values of 2D-strain echocardiography and serum biomarkers in the evaluation of cardiac fibrosis in this condition were assessed through correlation analyses. METHODS AND RESULTS: Patients with AS referred for surgical valve replacement were prospectively and consecutively included. They all had a comprehensive echocardiography including 2D strain. Blood samples were collected to measure cytokines and inflammatory biomarkers using Luminex bead-based assays. A per-surgical myocardial biopsy of the basal antero-septal segment (S1) was performed. Serial sections of each biopsy were stained with Sirius red. Digital image analysis was used to quantify fibrosis. Immunostainings using specific antibodies against macrophage, glycoprotein (gp) 130, and interleukin 6 (IL-6) were also performed. Patients were divided into tertiles reflecting the severity of fibrosis: mild, moderate, and severe load (TF1 to TF3). The mean age of the 58 included patients was 73 ± 11 years. Twenty-four (43%) were in New York Heart Association III-IV. Mean aortic valve area was 0.8 ± 0.2 cm2 . Mean aortic stenosis peak velocity and mean gradient were respectively 4.5 ± 0.8 m/s and 54 ± 15 mmHg. The mean LV ejection fraction was 54 ± 12%, and the global LV longitudinal strain was -15 ± 4%. The mean S1 strain, corresponding to the biopsied region, was -10 ± 6% and was strongly correlated to fibrosis load (R = 0.83, P < 0.0001). TF3 was associated with higher mortality (P = 0.009), higher serum C-reactive protein and IL-6, and lower gp130 compared with the other tertiles (P < 0.05). IL-6 and gp130 were expressed in the heart and respectively in the plasma membrane of macrophages and in the cytoplasm of both macrophages and cardiomyocytes. During follow-up, three patients died and were all in the third fibrosis tertile. CONCLUSIONS: We found a positive correlation between elevated inflammatory markers and degree of fibrosis load. These two parameters were associated with worse outcomes in patients with severe AS. Our results may be of interest especially in patients for whom a transcatheter aortic valve implantation is indicated and myocardial biopsy is not possible. Strategies aiming at preventing inflammation might be considered to decrease or limit the progression of cardiac fibrosis in patients followed for AS.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Miocardio/patología , Anciano , Anciano de 80 o más Años , Femenino , Fibrosis/complicaciones , Fibrosis/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
11.
J Cardiovasc Surg (Torino) ; 59(5): 746-752, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29786406

RESUMEN

BACKGROUND: Concerns have been previously raised regarding the potential early degeneration of the Mitroflow (Sorin Group Italia, Saluggia, Vercelli, Italy) bioprostheses. We aimed to evaluate our clinical experience with the Mitroflow LXA prosthesis for aortic valve replacement. METHODS: We prospectively analyzed data from 227 consecutive patients (133 males, mean age 73.9±9.2 years) implanted with the Mitroflow LXA between February 2007 and October 2011. Follow-up data were obtained by contacting the referring cardiologists. Kaplan-Meier curves were constructed for all-cause mortality, valve related mortality and structural valve degeneration (SVD). Multivariable analysis was conducted to identify SVD predictors. RESULTS: Median follow-up time was 54.2±37.9 months and completeness of follow-up was 95%. Overall mortality in the entire series was at 31% (N.=71) and mortality from cardiac or unknown causes at 20% (N.=46). SVD occurred in 24 patients (10%) (median delay between implantation and diagnosis: 62.6 (36.5) months). Reintervention was required in 20 cases (13 redo surgery, 7 percutaneous transcatheter valve intervention). The 8 years actuarial global survival was 54.7±4.9%, freedom from valve related mortality 67.5±4.9% and freedom from SVD 72±8%. The estimated freedom from SVD was significantly (P=0.007) longer in larger prosthesis (diameter >21 mm, 77±11%) compared to the smaller devices (≤21 mm, 59±13%.). Multivariate analysis identified smaller prostheses and age at implantation as independent predictors of SVD. CONCLUSIONS: The Mitroflow LXA showed evidence of early SVD in this cohort. A close follow-up of these patients is strongly advised.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Factores de Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Supervivencia sin Enfermedad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Paris , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Eur Heart J ; 37(47): 3525-3531, 2016 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-26908951

RESUMEN

BACKGROUND: Aortic stenosis (AS) and transthyretin cardiac amyloidosis (TTR-CA) are both frequent in elderly. The combination of these two diseases has never been investigated. AIMS: To describe patients with concomitant AS and TTR-CA. METHODS: Six cardiologic French centres identified retrospectively cases of patients with severe or moderate AS associated with TTR-CA hospitalized during the last 6 years. RESULTS: Sixteen patients were included. Mean ± SD age was 79 ± 6 years, 81% were men. Sixty per cent were NYHA III-IV, 31% had carpal tunnel syndrome, and 56% had atrial fibrillation. Median (Q1;Q4) NT-proBNP was 4382 (2425;4730) pg/mL and 91% had elevated cardiac troponin level. Eighty-eight per cent had severe AS (n = 14/16), of whom 86% (n = 12) had low-gradient AS. Mean ± SD interventricular septum thickness was 18 ± 4 mm. Mean left ventricular ejection fraction and global LS were 50 ± 13% and -7 ± 4%, respectively. Diagnosis of TTR-CA was histologically proven in 38%, and was based on strong cardiac uptake of the tracer at biphosphonate scintigraphy in the rest. Eighty-one per cent had wild-type TTR-CA (n = 13), one had mutated Val122I and 19% did not had genetic test (n = 3). Valve replacement was surgical in 63% and via transcatheter in 13%. Median follow-up in survivors was 33 (16;65) months. Mortality was of 44% (n = 7) during the whole follow-up period. CONCLUSIONS: Combination of AS and TTR-CA may occur in elderly patients particularly those with a low-flow low-gradient AS pattern and carries bad prognosis. Diagnosis of TTR-CA in AS is relevant to discuss specific treatment and management.


Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Anciano , Femenino , Humanos , Masculino , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Prealbúmina , Volumen Sistólico , Resultado del Tratamiento
13.
Eur J Heart Fail ; 16(6): 639-47, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24549756

RESUMEN

AIMS: To evaluate the prognostic impact of QRS width in patients with low-flow/low-gradient aortic stenosis (LF/LGAS). METHODS AND RESULTS: Among 88 consecutive patients referred to our institution for LF/LGAS from September 1994 to March 2007, baseline demographic, clinical, echocardiographic, and electrocardiographic data were collected. This population was divided into two groups according to baseline QRS duration (cut-off QRS ≥130 ms). Follow-up data, including electrocardiographic evolution and overall mortality, were analysed. The mean follow-up duration was 3.1 (2.2-6.2) years. In the whole group, 67 patients underwent surgical aortic valve replacement. Forty-nine patients (56%) had a QRS duration ≥130 ms. Among operated patients, there was no significant change in QRS duration between baseline and latest follow-up (126 ± 26 ms vs. 131 ± 25 ms; P = 0.82). In addition, wider QRS was a strong independent predictor of overall mortality (hazard ratio 2.20, 95% confidence interval 1.15-4.24; P = 0.027). CONCLUSION: Significant intraventricular conduction disturbances are common in patients with LF/LGAS and do not recover after aortic valve replacement. QRS duration is strongly associated with mortality in this selected population.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/epidemiología , Electrocardiografía , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/etiología , Arritmias Cardíacas/etiología , Angiografía Coronaria , Ecocardiografía de Estrés , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Disfunción Ventricular Izquierda/complicaciones
14.
J Am Soc Echocardiogr ; 26(8): 868-74, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23768690

RESUMEN

BACKGROUND: Global longitudinal strain (GLS) and basal longitudinal strain (BLS) assessed using two-dimensional speckle-tracking imaging have been proposed as subtle markers of left ventricular (LV) systolic dysfunction with potential prognostic value in patients with aortic stenosis (AS). The aim of this study was to evaluate the relationship between longitudinal strain and symptomatic status in patients with AS. METHODS: GLS and BLS were measured in 171 patients with pure, isolated, at least mild AS prospectively enrolled at two institutions. The population was divided into four groups: asymptomatic nonsevere AS (n = 55), asymptomatic severe AS with preserved LV ejection fraction (LVEF; ≥50%) (n = 37), symptomatic severe AS with preserved LVEF (n = 60), and severe AS with reduced LVEF (<50%) (n = 19). RESULTS: GLS was significantly different among the four groups (P < .0001), but the difference was due mainly to patients with reduced LVEFs. In addition, there was an important overlap among the groups, and in multivariate analysis, after adjustment for age, gender, AS severity, and LVEF, GLS was not an independent predictor of symptomatic status (P = .07). BLS was also significantly different among the four groups (P < .0001) but in contrast was independently associated with symptomatic status (P < .0001). However, as for GLS, there was an important overlap between groups and differences were close to intraobserver or interobserver variability (1.3 ± 1.1% and 2.0 ± 1.6%, respectively). CONCLUSIONS: In this prospective multicenter cohort of patients with wide ranges of AS severity, symptoms, and LVEFs, BLS but not GLS was independently associated with symptomatic status. However, there was an important overlap among groups, and differences were close to measurements' reproducibility, raising caution regarding the use of longitudinal strain, at least as a single criterion, in the decision-making process for patients with severe asymptomatic AS.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Anciano , Estudios de Cohortes , Femenino , Francia/epidemiología , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Am Soc Echocardiogr ; 26(7): 721-6, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23623594

RESUMEN

BACKGROUND: Right ventricular (RV) function is a strong predictor of patient outcome after cardiac surgery. Limited studies have compared the predictive value of RV global longitudinal strain (RV-GLS) with tricuspid annular plane systolic excursion (TAPSE) and RV fractional area change (RVFAC) in this setting. METHODS: The study included 250 patients (66 ± 13 years old, LVEF = 52% ± 12%) referred for cardiac surgery (EuroSCORE-II = 4.8% ± 8.0%). RV function before surgery was assessed by RV-GLS by using speckle-tracking analysis (3-segment from the RV free wall), RVFAC and TAPSE was compared with postoperative outcome defined by 1-month mortality. RESULTS: Overall, 19 patients (7.6%) had RVFAC < 35%, 34 (13.6%) had TAPSE < 16 mm, and 99 (39.6%) had impaired RV-GLS > -21% (35% with normal RVFAC ≥ 35%). Postoperative death (n = 25) was higher in patients with abnormal RV-GLS > -21% (22% vs 3%; P < .0001), TAPSE < 16 mm (24% vs 8%; P = .007), and RVFAC < 35% (32% vs 9%; P = .001). Mortality was 3% in patients with preserved RV-GLS. In patients with preserved RVFAC ≥ 35% but abnormal RV-GLS, mortality was similar to that of those with RVFAC < 35% (20% vs 32%; P = .12). Among RV systolic indexes, only RV-GLS was associated with patient outcome by multivariate analysis adjusted to EuroSCORE-II and cardiopulmonary bypass duration. CONCLUSIONS: RV-GLS is a sensitive marker of RV dysfunction and correlates with postoperative mortality.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Ecocardiografía Doppler , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/fisiopatología , Anciano , Área Bajo la Curva , Distribución de Chi-Cuadrado , Comorbilidad , Femenino , Hemodinámica , Humanos , Modelos Logísticos , Masculino , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo
16.
Am J Cardiol ; 111(12): 1778-83, 2013 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-23528030

RESUMEN

Transcatheter aortic valve implantation (TAVI) is effective in treating severe aortic stenosis in high-risk surgical patients. We evaluated the value of the QRS duration (QRSd) in predicting the mid-term morbidity and mortality after TAVI. We conducted a prospective cohort study of 91 consecutive patients who underwent TAVI using the CoreValve at our teaching hospital cardiology unit in 2008 to 2010 who survived to hospital discharge; 57% were women, and their mean age was 84 ± 7 years. The QRSd at discharge was used to classify the patients into 3 groups: QRSd ≤120 ms, n = 18 (20%); QRSd >120 ms but ≤150 ms, n = 30 (33%); and QRSd >150 ms, n = 43 (47%). We used 2 end points: (1) all-cause mortality and (2) all-cause mortality or admission for heart failure. After a median of 12 months, the normal-QRSd patients showed a trend toward, or had, significantly better overall survival and survival free of admission for heart failure compared with the intermediate-QRSd group (p = 0.084 and p = 0.002, respectively) and the long-QRSd group (p = 0.015 and p = 0.001, respectively). The factors significantly associated with all-cause mortality were the Society of Thoracic Surgeons score, aortic valve area, post-TAVI dilation, acute kidney injury, hospital days after TAVI, and QRSd at discharge. On multivariate analysis, QRSd was the strongest independent predictor of all-cause mortality (hazard ratio 1.036, 95% confidence interval 1.016 to 1.056; p <0.001) and all-cause mortality or heart failure admission (hazard ratio 1.025, 95% confidence interval 1.011 to 1.039; p <0.001). The other independent predictors were the Society of Thoracic Surgeons score, acute kidney injury, and post-TAVI hospital days. In conclusion, a longer QRSd after TAVI was associated with greater morbidity and mortality after 12 months. The QRSd at discharge independently predicted mortality and morbidity after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Estudios de Cohortes , Electrocardiografía , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hospitales de Enseñanza , Humanos , Pacientes Internos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento
17.
Am J Cardiol ; 111(11): 1619-24, 2013 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-23523059

RESUMEN

Decrease in blood platelet count has been described after percutaneous coronary intervention and surgical valve replacement, although no study has been performed in the setting of transcatheter aortic valve implantation (TAVI). The aim of this study was to address the incidence, mechanism, and impact of blood platelet count decrease after TAVI. One hundred forty-four consecutive patients (mean age 84 ± 7 years, 64 men) with severe symptomatic aortic stenosis who underwent TAVI from December 2007 to July 2011 were enrolled. Blood platelet count was recorded before and after aortic valve implantation. Decrease in blood platelet count was compared with in-hospital major adverse cardiovascular events (death, stroke, and major or life-threatening bleeding). Blood platelet count decreases occurred in all but 1 patient. The percentage of platelet count decrease averaged 34 ± 15% and was 24% greater than blood protein decrease. Decrease in platelet count was associated with a higher rate of prosthesis migration, longer x-ray and procedural times, and larger contrast amounts (230 ± 128 ml for the third tertile vs 170 ± 77 ml for the second and first tertiles, p = 0.0006), but no association was observed with regard to changes in bilirubin. In-hospital major adverse cardiovascular events (n = 50 [35%]) were observed more frequently in patients with severe platelet count decreases (21% for the first tertile, 35% for the second tertile, and 48% for the third tertile, p = 0.02). Finally, the percentage of blood platelet count decrease was the only predictor of in-hospital major adverse cardiovascular events (odds ratio 1.67, 95% confidence interval 1.05 to 2.67, p = 0.03). In conclusion, a decrease in platelet count is a common phenomenon after TAVI, and its severity is associated with poor outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemorragia Posoperatoria/epidemiología , Accidente Cerebrovascular/epidemiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Cateterismo Cardíaco/efectos adversos , Femenino , Arteria Femoral , Estudios de Seguimiento , Francia/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Recuento de Plaquetas , Hemorragia Posoperatoria/etiología , Pronóstico , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Trombosis/sangre , Trombosis/etiología , Trombosis/prevención & control
18.
Catheter Cardiovasc Interv ; 81(5): 882-7, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22972678

RESUMEN

OBJECTIVE: To identify clinical and electrical factors predicting delayed high-degree atrio-ventricular block (AVB) after transcatheter aortic valve implantation (TAVI). BACKGROUND: TAVI is a new technique for treating severe aortic valve stenosis in patients at high surgical risk but can be followed by high-grade AVB requiring permanent pacing (PP). METHODS AND RESULTS: The study included 79 patients (82 ± 17 years, Euroscore = 23% ± 10%) free of PP need before and immediately after TAVI procedure. Delayed high-degree AVB was defined by types 2 or 3 AVB diagnosed at least 24 hr after the index procedure. Permanent pacemaker implantation was performed for all these patients. We compared clinical and electrical variables before and after TAVI in patients with delayed AVB or not. TAVI was performed successfully in all patients. The 21 (26%) patients who exhibited delayed high-grade AVB had significantly deeper prosthesis implantation (12 ± 4 mm vs. 9 ± 5 mm, P = 0.03) and wider post-TAVI QRS duration (155 ± 17 msec vs. 131 ± 25 msec, P = 0.0004), with no difference in baseline QRS duration. Post-TAVI QRS duration was the only independent predictor of post-TAVI permanent for delayed high-degree AVB (P = 0.02). After a mean follow-up of 10 ± 8 months, all 21 patients with post-TAVI QRS ≤ 128 msec were free of high-grade AVB, whereas 21/55 (38%) patients with post-TAVI QRS >128 msec had PP (P = 0.0016). CONCLUSION: Delayed (>24 hr after the procedure) high-grade AVB necessitating PP is common after TAVI. QRS duration measured immediately after TAVI was the best independent predictor of PP in this population. Patients with QRS ≤ 128 msec immediately after TAVI had no risk of requiring PP.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Bloqueo Atrioventricular/etiología , Bioprótesis , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Distribución de Chi-Cuadrado , Electrocardiografía , Femenino , Frecuencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Marcapaso Artificial , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
19.
Eur Heart J Cardiovasc Imaging ; 14(1): 77-84, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22893712

RESUMEN

AIMS: Global longitudinal strain (GLS) seems accurate for detecting subclinical myocardial dysfunction, and may therefore be used to improve risk stratification for cardiac surgery. METHODS AND RESULTS: Longitudinal strain (by two-dimensional speckle tracking) was computed in 425 patients [mean age 67 ± 13 years, 69% male, left ventricular ejection fraction (LVEF) 51 ± 13%] referred for cardiac surgery [isolated coronary artery bypass graft (CABG) (n = 155), aortic valve surgery (n = 174), mitral surgery (n = 96)]. GLS (global-ε) was assessed for predicting early postoperative death. Despite a fair correlation between LVEF and global strain (r = -0.73, P < 0.0001), 40% of patients with preserved LVEF (defined as LVEF ≥50%) had abnormal global-ε (defined as global-ε >-16%): -12.8 ± 1.7%, range -15% to -8%. In patients with preserved LVEF, NT-proBNP level (983 vs. 541 pg/mL, P = 0.03), heart failure symptoms (NYHA class, 2.2 ± 0.9 vs. 1.9 ± 0.9, P = 0.02), and the need for prolonged (>48 h) inotropic support after surgery (33.3 vs. 21.2%, P = 0.03) were greater when global-ε was impaired. Importantly, despite similar EuroSCORE (9.7 ± 12 vs. 7.7 ± 9%, P = 0.2 for EuroSCORE I and 4.2 ± 6.2 vs. 3.4 ± 4.9%, P = 0.4 for EuroSCORE II), the rate of postoperative death was 2.4-fold (11.8 vs. 4.9%, P = 0.04) in patients with preserved LVEF when global-ε was impaired. Multivariate analysis showed that global-ε is an independent predictor for early postoperative mortality [odds ratio = 1.10 (1.01-1.21)] after adjustment to EuroSCORE. CONCLUSION: GLS has an incremental value over LVEF for risk stratification in patients referred for cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Volumen Sistólico , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda
20.
Am J Cardiol ; 111(1): 94-9, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23068861

RESUMEN

The present study sought to assess the effectiveness of local anesthesia with conscious sedation (LACS) during transcatheter aortic valve implantation (TAVI). On its introduction, TAVI was mostly performed with the patient under general anesthesia (GA); however, evidence supporting the use of less-invasive LACS has been increasing. The data from 174 consecutive patients who underwent TAVI by way of the femoral artery from December 2007 to December 2011 were analyzed. GA was mainly used in early phase of the study (n = 44); this was gradually shifted to LACS in the late phase (n = 130). The clinical outcomes were compared for those patients who received GA versus LACS. The incidence and causes of "LACS failure," defined as conversion to GA from LACS during TAVI, were also assessed. The rates of procedural success and 30-day mortality were not different between the 2 groups (93.3% vs 95.3%, p = 0.60; 6.7% vs 7.8%, p = 0.55, respectively). Although the clinical backgrounds of the patients showed differences, these results were not significant after adjusting for other influential confounders. The intensive care unit stay and hospital stay were longer in the GA group than in the LACS group (3.9 ± 2.2 vs 3.3 ± 1.5 days, p = 0.044; and 12.2 ± 8.3 vs 8.1 ± 6.5 days, p = 0.001, respectively). LACS failure occurred in 6 patients (4.6%), and the causes were multifactorial, as follows: cardiac tamponade in 2, cardiac arrest in 2, myocardial infarction in 1, and stroke in 1. In conclusion, transfemoral TAVI with the patient under LACS could be successfully performed in most patients, with the advantage of early recovery, although the perioperative risks involved in the TAVI procedure should be considered.


Asunto(s)
Anestesia Local/métodos , Anestésicos Locales/administración & dosificación , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Sedación Consciente/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Causas de Muerte/tendencias , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA