Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 13(3)2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36979591

RESUMEN

A sensitive and selective label-free photoelectrochemical (PEC) immunosensor was designed for the detection of cardiac troponin I (cTnI). The platform was based on a fluorine-doped tin oxide (FTO)-coated glass photoelectrode modified with bismuth vanadate (BiVO4) and sensitized by an electrodeposited bismuth sulfide (Bi2S3) film. The PEC response of the Bi2S3/BiVO4/FTO platform for the ascorbic acid (AA) donor molecule was approximately 1.6-fold higher than the response observed in the absence of Bi2S3. The cTnI antibodies (anti-cTnI) were immobilized on the Bi2S3/BiVO4/FTO platform surface to produce the anti-cTnI/Bi2S3/BiVO4/FTO immunosensor, which was incubated in cTnI solution to inhibit the AA photocurrent. The photocurrent obtained by the proposed immunosensor presented a linear relationship with the logarithm of the cTnI concentration, ranging from 1 pg mL-1 to 1000 ng mL-1. The immunosensor was successfully employed in artificial blood plasma samples for the detection of cTnI, with recovery values ranging from 98.0% to 98.5%.


Asunto(s)
Técnicas Biosensibles , Infarto del Miocardio , Humanos , Límite de Detección , Técnicas Electroquímicas , Troponina I , Flúor , Inmunoensayo , Electrodos , Infarto del Miocardio/diagnóstico , Biomarcadores
2.
Food Chem ; 227: 16-21, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28274417

RESUMEN

A novel photoelectrochemical sensor was developed for determination of tert-butyl-hydroquinone (TBHQ) in edible vegetable oils, based on CdSe/ZnS core-shell quantum dots sensitized with lithium tetracyanoethylenide (LiTCNE). The CdSe/ZnS/LiTCNE photoelectrochemical sensor presented a TBHQ photocurrent about 13-fold higher and a charge transfer resistance 62-fold lower than observed for a CdSe/ZnS sensor. The photoelectrochemical sensor showed selectivity to TBHQ, with a high photocurrent for this antioxidant compared to the photocurrent responses for other phenolic antioxidants. The CdSe/ZnS/LiTCNE photoelectrochemical sensor presented a linear range from 0.6 to 250µmolL-1, sensitivity of 0.012µALµmol-1, and a limit of detection of 0.21µmolL-1 for TBHQ, under optimized experimental conditions. The sensor was successfully employed in the analysis of edible oil samples, with recoveries of between 98.25% and 99.83% achieved.


Asunto(s)
Antioxidantes/química , Aditivos Alimentarios/química , Análisis de los Alimentos/métodos , Hidroquinonas/química , Aceites de Plantas/química , Análisis de los Alimentos/instrumentación , Litio/química , Puntos Cuánticos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA