1.
Cureus ; 15(4): e38245, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37252510

RESUMEN

Background Intraoperative hypofibrinogenemia is a major factor associated with increased postoperative blood loss in adult cardiac surgery. However, previous pediatric studies on this topic did not sufficiently adjust for potential confounders and variations in surgeons' techniques. Therefore, evidence for the association between hypofibrinogenemia and postoperative blood loss after cardiac surgery in children remains insufficient. In this study, we aimed to evaluate the association between postoperative blood loss and hypofibrinogenemia by adjusting for potential confounders and the effects of differences in surgeons' techniques. Methodology This single-center, retrospective, cohort study included children who underwent cardiac surgery with cardiopulmonary bypass from April 2019 to March 2022. Multilevel logistic regression models with mixed effects were used to evaluate the association of major blood loss in the first six hours postoperatively with fibrinogen concentration at the end of cardiopulmonary bypass. The difference in the surgeon's techniques was adjusted as a random effect for the model. The model included potential confounders identified as risk factors in previous studies. Results A total of 401 patients were included. A fibrinogen concentration ≤150 mg/dL (adjusted odds ratio (aOR) = 2.08; 95% confidence interval (CI) = 1.18-3.67; p = 0.011) and the presence of cyanotic disease (aOR = 2.34; 95% CI = 1.10-4.97; p = 0.027) were associated with major blood loss in the first six postoperative hours. Conclusions A fibrinogen concentration ≤150 mg/dL and the presence of cyanotic disease were associated with postoperative blood loss in pediatric cardiac surgery. Maintaining a fibrinogen concentration >150 mg/dL is recommended, especially for patients with cyanotic diseases.

2.
Pediatr Cardiol ; 43(6): 1205-1213, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35124709

RESUMEN

We evaluate the validity of cardiac index (CI) measurements utilizing the Ultrasonic Cardiac Output Monitor (USCOM), a non-invasive Doppler ultrasound device, by comparing measurements to cardiac catheterization-derived CI measurements in patients with single-ventricle physiology. USCOM measurements were repeated three times for each patient at the beginning of a cardiac catheterization procedure for twenty-six patients undergoing elective pre-Glenn or pre-Fontan catheterization. CI was measured by USCOM and was calculated from cardiac catheterization data using Fick's method. Bland-Altman analysis for CI showed bias of 0.95 L/min/m2 with the 95% limits of agreement of - 1.85 and 3.75. Pearson's correlation coefficient was 0.89 (p < 0.001) indicating a strong positive relationship between USCOM and cardiac catheterization CI measurements. When excluding two patients with significant dilation of the neo-aortic valve (z-score > + 5), the bias improved to 0.66 L/min/m2 with the 95% limits of agreement of - 1.38 and 2.70. Percent error of limits of agreement was 34%. There was excellent intra-operator reproducibility of USCOM CI measurements with an intra-class coefficient of 0.96. We demonstrate the use of USCOM to measure CI in patients with single-ventricle physiology for the first time, showing acceptable agreement of the CI measurements between USCOM and cardiac catheterization with a high intra-operator reproducibility.


Asunto(s)
Anomalías Cardiovasculares , Ultrasonido , Gasto Cardíaco , Humanos , Monitoreo Fisiológico/métodos , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...