Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Ophthalmol Retina ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38750936

RESUMEN

PURPOSE: To report a previously undescribed finding of peripapillary hyper reflective ovoid mass-like structures (PHOMS) in Stickler Syndrome DESIGN: Non-comparative case series SUBJECTS: Participants, and/or Controls: 22 eyes with anomalous optic disc from 11 Stickler Syndrome patients were identified and imaged. METHODS: Intervention, or Testing: PHOMS were graded using enhanced depth imaging optical coherence tomography (EDI-OCT) according to the consensus recommendations of The Optic Disc Drusen Studies Consortium. All EDI-OCT scans were obtained using the Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany) with a dense horizontal raster (15 × 10°, 97 sections) centred on the optic nerve head and graded by two independent assessors. In case of disagreement, the image was graded by a third assessor. The presence of any co-existing optic disc drusen was also assessed using EDI-OCT and autofluorescence. MAIN OUTCOME MEASURES: The presence of PHOMS, clinical characteristics and genetic mutations. RESULTS: A pilot sample of 22 eyes with phenotypic optic disc abnormalities from 11 Stickler Syndrome patients were identified and imaged. Eight patients were female and 3 were male. The mean age was 31 years (13-58 years). PHOMS were present in 91% (n=20 eyes) of imaged eyes. 70% (n=14 eyes) were type 1 Stickler Syndrome and 30% (n=6 eyes) were type 2 Stickler Syndrome. Five percent (n=1 eye) developed retinal detachment and 75% (n=15 eyes) had undergone 360o prophylactic retinopexy. 41% (n=9) of eyes with PHOMS were present in patients with co-existing hearing loss and 13.6% (n=3) had orofacial manifestation of Stickler Syndrome in the form of a cleft palate. Seventy-five percent (n=15 eyes) of patients with PHOMS reported joint laxity or symptoms of arthritis. No co-existing optic disc drusen were identified and raised intracranial pressure was also excluded after neurological investigation. CONCLUSION: These data suggest that PHOMS are a novel finding in Stickler Syndrome patients and should be considered when evaluating the optic nerves of these patients.

2.
Transl Vis Sci Technol ; 13(4): 15, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38591945

RESUMEN

Purpose: The purpose of this study was to estimate the distribution of the true rates of progression (RoP) of visual field (VF) loss. Methods: We analyzed the progression of mean deviation over time in series of ≥ 10 tests from 3352 eyes (one per patient) from 5 glaucoma clinics, using a novel Bayesian hierarchical Linear Mixed Model (LMM); this modeled the random-effect distribution of RoPs as the sum of 2 independent processes following, respectively, a negative exponential distribution (the "true" distribution of RoPs) and a Gaussian distribution (the "noise"), resulting in a skewed exGaussian distribution. The exGaussian-LMM was compared to a standard Gaussian-LMM using the Watanabe-Akaike Information Criterion (WAIC). The random-effect distributions were compared to the empirical cumulative distribution function (eCDF) of linear regression RoPs using a Kolmogorov-Smirnov test. Results: The WAIC indicated a better fit with the exGaussian-LMM (estimate [standard error]: 192174.4 [721.2]) than with the Gaussian-LMM (192595 [697.4], with a difference of 157.2 [22.6]). There was a significant difference between the eCDF and the Gaussian-LMM distribution (P < 0.0001), but not with the exGaussian-LMM distribution (P = 0.108). The estimated mean (95% credible intervals, CIs) "true" RoP (-0.377, 95% CI = -0.396 to -0.359 dB/year) was more negative than the observed mean RoP (-0.283, 95% CI = -0.299 to -0.268 dB/year), indicating a bias likely due to learning in standard LMMs. Conclusions: The distribution of "true" RoPs can be estimated with an exGaussian-LMM, improving model accuracy. Translational Relevance: We used these results to develop a fast and accurate analytical approximation for sample-size calculations in clinical trials using standard LMMs, which was integrated in a freely available web application.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Teorema de Bayes , Glaucoma/diagnóstico , Ojo , Programas Informáticos
3.
Invest Ophthalmol Vis Sci ; 65(4): 28, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38630674

RESUMEN

Purpose: The purpose of this study was to investigate structure-function correlations in multiple evanescent white dot syndrome (MEWDS) using microperimetry (MP) and spectral-domain optical coherence tomography (SD-OCT). Methods: Single-center prospective observational study including 14 eyes from 13 patients with MEWDS monitored over a median of 49.5 days (interquartile range = 29-92 days). Investigations focused on best-corrected visual acuity (BCVA), foveal granularity, and the Photoreceptor Reflectivity Ratio (PRR) as a measure of photoreceptor integrity. MP assessed average retinal threshold sensitivity (RTS) and bivariate contour ellipse area (BCEA) for fixation stability. A linear mixed model was used to test associations and interactions among RTS, time, and clinical variables. A hierarchical linear mixed model was used to analyze structure-function relationships, addressing both individual and location-specific variations. Results: Overall, 2340 MP locations were tested. PRR revealed a transient decrease within 30 days post-presentation, indicative of early photoreceptor disruption, followed by a progressive increase, signaling recovery. Significantly lower foveal sensitivity (RTS = 14.8 ± 7.4 vs. 22.5 ± 4.4 decibel [dB], P = 0.04) and increased fixation spread (63% BCEA = 1.26 ± 0.97 vs. 0.48 ± 0.35 deg2, P = 0.06) were noted in eyes with foveal granularity compared to those without. A significant increase in RTS was demonstrated over time (0.066 dB/day, P < 0.001), with a central-to-peripheral gradient of improvement. The interaction between follow-up time and baseline BCVA (P < 0.001) indicated more rapid improvement in eyes with worse initial vision. There was a robust, nonlinear association between PRR and RTS across all tested locations (P < 0.001), becoming asymptotic for sensitivity losses exceeding 20 dB. Conclusions: Photoreceptor reflectivity accurately aligned with visual function in MEWDS on longitudinal examinations. The central-to-peripheral gradient of improvement may suggest specific vulnerabilities underlying the area around the disc.


Asunto(s)
Retina , Síndromes de Puntos Blancos , Humanos , Agudeza Visual , Retina/fisiología , Fóvea Central , Tomografía de Coherencia Óptica
4.
Ophthalmology ; 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38354911

RESUMEN

PURPOSE: To investigate whether intraocular pressure (IOP) fluctuation is associated independently with the rate of visual field (VF) progression in the United Kingdom Glaucoma Treatment Study. DESIGN: Randomized, double-masked, placebo-controlled multicenter trial. PARTICIPANTS: Participants with ≥5 VFs (213 placebo, 217 treatment). METHODS: Associations between IOP metrics and VF progression rates (mean deviation [MD] and five fastest locations) were assessed with linear mixed models. Fluctuation variables were mean Pascal ocular pulse amplitude (OPA), standard deviation (SD) of diurnal Goldmann IOP (diurnal fluctuation), and SD of Goldmann IOP at all visits (long-term fluctuation). Fluctuation values were normalized for mean IOP to make them independent from the mean IOP. Correlated nonfluctuation IOP metrics (baseline, peak, mean, supine, and peak phasing IOP) were combined with principal component analysis, and principal component 1 (PC1) was included as a covariate. Interactions between covariates and time from baseline modeled the effect of the variables on VF rates. Analyses were conducted separately in the two treatment arms. MAIN OUTCOME MEASURES: Associations between IOP fluctuation metrics and rates of MD and the five fastest test locations. RESULTS: In the placebo arm, only PC1 was associated significantly with the MD rate (estimate, -0.19 dB/year [standard error (SE), 0.04 dB/year]; P < 0.001), whereas normalized IOP fluctuation metrics were not. No variable was associated significantly with MD rates in the treatment arm. For the fastest five locations in the placebo group, PC1 (estimate, -0.58 dB/year [SE, 0.16 dB/year]; P < 0.001), central corneal thickness (estimate, 0.26 dB/year [SE, 0.10 dB/year] for 10 µm thicker; P = 0.01) and normalized OPA (estimate, -3.50 dB/year [SE, 1.04 dB/year]; P = 0.001) were associated with rates of progression; normalized diurnal and long-term IOP fluctuations were not. In the treatment group, only PC1 (estimate, -0.27 dB/year [SE, 0.12 dB/year]; P = 0.028) was associated with the rates of progression. CONCLUSIONS: No evidence supports that either diurnal or long-term IOP fluctuation, as measured in clinical practice, are independent factors for glaucoma progression; other aspects of IOP, including mean IOP and peak IOP, may be more informative. Ocular pulse amplitude may be an independent factor for faster glaucoma progression. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

5.
Retina ; 44(5): 852-860, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38166238

RESUMEN

PURPOSE: To compare within-subject efficacy and safety of intravitreal dexamethasone implant and topical carbonic anhydrase inhibitors in the treatment of retinitis pigmentosa-related cystoid macular edema. METHODS: Patients with bilateral retinitis pigmentosa-related cystoid macular edema were treated with intravitreal dexamethasone implant in one eye and topical carbonic anhydrase inhibitors in the contralateral eye. The primary endpoint was a change in central macular thickness. Secondary endpoints were changes in best-corrected visual acuity and microperimetric central retinal sensitivity. Intraocular pressure and other ocular complications were evaluated for safety assessment. RESULTS: Nine patients were recruited for this 12-month follow-up study. Central macular thickness was significantly lower in intravitreal dexamethasone implant-treated eyes than in topical carbonic anhydrase inhibitors-treated eyes at Months 1 and 7, whereas mean best-corrected visual acuity was better in eyes treated with topical carbonic anhydrase inhibitors at Month 12 (borderline significant P = 0.0510). There was no difference in microperimetric sensitivity between the two treatments. Three patients developed ocular hypertension after intravitreal dexamethasone implant. Intravitreal dexamethasone implant showed an effect on the contralateral eye in five of nine patients. CONCLUSION: Intravitreal dexamethasone implant was more effective than topical carbonic anhydrase inhibitors in reducing retinitis pigmentosa-related cystoid macular edema 1 month after treatment. Corticosteroids can play a key role in the management of retinitis pigmentosa-related cystoid macular edema; however, their routes, timing, and modes of administration should be further explored.


Asunto(s)
Inhibidores de Anhidrasa Carbónica , Dexametasona , Implantes de Medicamentos , Glucocorticoides , Edema Macular , Retinitis Pigmentosa , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Retinitis Pigmentosa/tratamiento farmacológico , Retinitis Pigmentosa/fisiopatología , Retinitis Pigmentosa/complicaciones , Retinitis Pigmentosa/diagnóstico , Edema Macular/tratamiento farmacológico , Edema Macular/etiología , Edema Macular/diagnóstico , Edema Macular/fisiopatología , Inhibidores de Anhidrasa Carbónica/administración & dosificación , Inhibidores de Anhidrasa Carbónica/uso terapéutico , Dexametasona/administración & dosificación , Estudios Prospectivos , Femenino , Masculino , Proyectos Piloto , Glucocorticoides/administración & dosificación , Persona de Mediana Edad , Adulto , Estudios de Seguimiento , Inyecciones Intravítreas , Anciano , Resultado del Tratamiento , Administración Tópica
6.
J Glaucoma ; 33(3): 162-167, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38245812

RESUMEN

PRCIS: Using a Compass (CMP) (CMP, Centervue, Padova, Italy) fundus perimeter, Zippy Estimation by Sequential Testing (ZEST) FAST strategy showed a significant reduction in examination time compared with ZEST, with good agreement in the quantification of perimetric damage. PURPOSE: The aim of this study was to compare the test duration of ZEST strategy with ZEST FAST and to evaluate the test-retest variability of ZEST FAST strategy on patients with glaucoma and ocular hypertension. PATIENTS AND METHODS: This was a multicenter retrospective study. We analyzed 1 eye of 60 subjects: 30 glaucoma patients and 30 patients with ocular hypertension. For each eye we analyzed, 3 visual field examinations were performed with Compass 24-2 grid: 1 test performed with ZEST strategy and 2 tests performed with ZEST FAST. Mean examination time and mean sensitivity between the 2 strategies were computed. ZEST FAST test-retest variability was examined. RESULTS: In the ocular hypertension cohort, test time was 223±29 seconds with ZEST FAST and 362±48 seconds with ZEST (38% reduction, P <0.001). In glaucoma patients, it was respectively 265±62 and 386±78 seconds (31% reduction using ZEST FAST, P <0.001). The difference in mean sensitivity between the 2 strategies was -0.24±1.30 dB for ocular hypertension and -0.14±1.08 dB for glaucoma. The mean difference in mean sensitivity between the first and the second test with ZEST FAST strategy was 0.2±0.8 dB for patients with ocular hypertension and 0.24±0.96 dB for glaucoma patients. CONCLUSIONS: ZEST FAST thresholding provides similar results to ZEST with a significantly reduced examination time.


Asunto(s)
Glaucoma , Hipertensión Ocular , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Algoritmos , Presión Intraocular , Hipertensión Ocular/diagnóstico , Pruebas del Campo Visual/métodos
7.
Ophthalmology ; 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38199527

RESUMEN

PURPOSE: Review hypotony failure criteria used in glaucoma surgical outcome studies and evaluate their impact on success rates. DESIGN: Systematic literature review and application of hypotony failure criteria to 2 retrospective cohorts. PARTICIPANTS: A total of 934 eyes and 1765 eyes undergoing trabeculectomy and deep sclerectomy (DS) with a median follow-up of 41.4 and 45.4 months, respectively. METHODS: Literature-based hypotony failure criteria were applied to patient cohorts. Intraocular pressure (IOP)-related success was defined as follows: (A) IOP ≤ 21 mmHg with ≥ 20% IOP reduction; (B) IOP ≤ 18 mmHg with ≥ 20% reduction; (C) IOP ≤ 15 mmHg with ≥ 25% reduction; and (D) IOP ≤ 12 mmHg with ≥ 30% reduction. Failure was defined as IOP exceeding these criteria in 2 consecutive visits > 3 months after surgery, loss of light perception, additional IOP-lowering surgery, or hypotony. Cox regression estimated failure risk for different hypotony criteria, using no hypotony as a reference. Analyses were conducted for each criterion and hypotony type (i.e., numerical [IOP threshold], clinical [clinical manifestations], and mixed [combination of numerical or clinical criteria]). MAIN OUTCOME MEASURES: Hazard ratio (HR) for failure risk. RESULTS: Of 2503 studies found, 278 were eligible, with 99 studies (35.6%) lacking hypotony failure criteria. Numerical hypotony was predominant (157 studies [56.5%]). Few studies used clinical hypotony (3 isolated [1.1%]; 19 combined with low IOP [6.8%]). Forty-nine different criteria were found, with IOP < 6 mmHg, IOP < 6 mmHg on ≥ 2 consecutive visits after 3 months, and IOP < 5 mmHg being the most common (41 [14.7%], 38 [13.7%], and 13 [4.7%] studies, respectively). In both cohorts, numerical hypotony posed the highest risk of failure (HR, 1.51-1.21 for criteria A to D; P < 0.001), followed by mixed hypotony (HR, 1.41-1.20 for criteria A to D; P < 0.001), and clinical hypotony (HR, 1.12-1.04; P < 0.001). Failure risk varied greatly with various hypotony definitions, with the HR ranging from 1.02 to 10.79 for trabeculectomy and 1.00 to 8.36 for DS. CONCLUSIONS: Hypotony failure criteria are highly heterogenous in the glaucoma literature, with few studies focusing on clinical manifestations. Numerical hypotony yields higher failure rates than clinical hypotony and can underestimate glaucoma surgery success rates. Standardizing failure criteria with an emphasis on clinically relevant hypotony manifestations is needed. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

9.
Invest Ophthalmol Vis Sci ; 64(14): 36, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38010697

RESUMEN

Purpose: The purpose of this study was to test whether functional loss in the glaucomatous macula is characterized by an enlargement of Ricco's area (RA) through the application of a computational model linking retinal ganglion cell (RGC) damage to perimetric sensitivity. Methods: One eye from each of 29 visually healthy subjects <40 years old, 30 patients with glaucoma, and 20 age-similar controls was tested with a 10-2 grid with stimuli of 5 different area sizes. Structural estimates of point-wise RGC density were obtained from optical coherence tomography (OCT) scans. Structural and functional data from the young healthy cohort were used to estimate the parameters of a computational spatial summation model to generate a template. The template was fitted with a Bayesian hierarchical model to estimate the latent RGC density in patients with glaucoma and age-matched controls. We tested two alternative hypotheses: fitting the data by translating the template horizontally (H1: change in RA) or vertically (H2: loss of sensitivity without a change in RA). Root mean squared error (RMSE) of the model fits to perimetric sensitivity were compared. Ninety-five percent confidence intervals were bootstrapped. The dynamic range of the functional and structural RGC density estimates was denoted by their 1st and 99th percentiles. Results: The RMSE was 2.09 (95% CI = 1.92-2.26) under H1 and 2.49 (95% CI = 2.24-2.72) under H2 (P < 0.001). The average dynamic range for the structural RGC density estimates was only 11% that of the functional estimates. Conclusions: Macular sensitivity loss in glaucoma is better described by a model in which RA changes with RGC loss. Structural measurements have limited dynamic range.


Asunto(s)
Glaucoma , Células Ganglionares de la Retina , Adulto , Humanos , Teorema de Bayes , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos , Pruebas del Campo Visual , Campos Visuales , Degeneración Macular/diagnóstico
10.
Transl Vis Sci Technol ; 12(10): 20, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37906055

RESUMEN

Purpose: The purpose of this study was to evaluate the power of trend-based visual field (VF) progression end points against long-term development of event-based end points accepted by the US Food and Drug Administration (FDA). Methods: One eye from 3352 patients with ≥10 24-2 VFs (median = 11 years) follow-up were analyzed. Two FDA-compatible criteria were applied to these series to label "true-progressed" eyes: ≥5 locations changing from baseline by more than 7 dB (FDA-7) or by more than the expected test-retest variability (GPA-like) in 2 consecutive tests. Observed rates of progression (RoP) were used to simulate trial-like series (2 years) randomly assigned (1000 times) to a "placebo" or a "treatment" arm. We simulated neuroprotective "treatment" effects by changing the proportion of "true progressed" eyes in the two arms. Two trend-based methods for mean deviation (MD) were assessed: (1) linear mixed model (LMM), testing average difference in RoP between the two arms, and (2) time-to-progression (TTP), calculated by linear regression as time needed for MD to decline by predefined cutoffs from baseline. Power curves with 95% confidence intervals were calculated for trend and event-based methods on the simulated series. Results: The FDA-7 and GPA-like progression was achieved by 45% and 55% of the eyes in the clinical database. LMM and TTP had similar power, significantly superior to the event-based methods, none of which reached 80% power. All methods had a 5% false-positive rate. Conclusions: The trend-based methods can efficiently detect treatment effects defined by long-term FDA-compatible progression. Translational Relevance: The assessment of the power of trend-based methods to detect clinically relevant progression end points.


Asunto(s)
Glaucoma , Neuroprotección , Humanos , Ojo , Glaucoma/tratamiento farmacológico , Estados Unidos/epidemiología , Campos Visuales , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
Transl Vis Sci Technol ; 12(10): 10, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37831447

RESUMEN

Purpose: To assess the performance of a perimetric strategy using structure-function predictions from a deep learning (DL) model. Methods: Visual field test-retest data from 146 eyes (75 patients) with glaucoma with (median [5th-95th percentile]) 10 [7, 10] tests per eye were used. Structure-function predictions were generated with a previously described DL model using cicumpapillary optical coherence tomography (OCT) scans. Structurally informed prior distributions were built grouping the observed measured sensitivities for each predicted value and recalculated for each subject with a leave-one-out approach. A zippy estimation by sequential testing (ZEST) strategy was used for the simulations (1000 per eye). Ground-truth sensitivities for each eye were the medians of the test-retest values. Two variations of ZEST were compared in terms of speed (average total number of presentations [NP] per eye) and accuracy (average mean absolute error [MAE] per eye), using either a combination of normal and abnormal thresholds (ZEST) or the calculated structural distributions (S-ZEST) as prior information. Two additional versions of these strategies employing spatial correlations were tested. Results: S-ZEST was significantly faster, with a mean average NP of 213.87 (SD = 28.18), than ZEST, with a mean average NP of 255.65 (SD = 50.27) (P < 0.001). The average MAE was smaller for S-ZEST (1.98; SD = 2.37) than ZEST (2.43; SD = 2.69) (P < 0.001). Spatial correlations further improved both strategies (P < 0.001), but the differences between ZEST and S-ZEST remained significant (P < 0.001). Conclusions: DL structure-function predictions can significantly improve perimetric tests. Translational Relevance: DL structure-function predictions from clinically available OCT scans can improve perimetry in glaucoma patients.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales , Algoritmos , Glaucoma/diagnóstico , Células Ganglionares de la Retina
12.
Clin Exp Ophthalmol ; 51(8): 790-798, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37717946

RESUMEN

BACKGROUND: Evaluation of ocular inflammation via common imaging modalities like optical coherence tomography (OCT) has emphasised cell visualisation, but automated detection of uveitic keratic precipitates (KPs) remains unexplored. METHODS: Anterior segment (AS)-OCT dense volumes of the corneas of patients with uveitic KPs were collected at three timepoints: with active (T0), clinically improving (T1), and resolved (T2) inflammation. At each visit, visual acuity and clinical grading of the anterior chamber cells were assessed. A bespoke algorithm was used to create an en face rendering of the KPs and to calculate their volume and a ratio of the volume of precipitates over the analysed area. The variation of AS-OCT-derived measurements over time was assessed, and compared with clinical grading. RESULTS: Twenty eyes from 20 patients (13 females, mean age 39 years) were studied. At T0, the mean volume of the corneal KPs was 0.1727 mm3 , and it significantly reduced to 0.1111 mm3 (p = 0.03) only at T2. The ratio between the volume of the KPs and the corneal area decreased from T0 (0.007) to T1 (0.006; p = 0.2) and T2 (0.004; p = 0.009). There was a statistically significant correlation between the AC cell count and the AS-OCT volume measurements of the KPs at the three time points. CONCLUSIONS: AS-OCT can image uveitic KPs and through a bespoke algorithm we were able to create an en face rendering allowing us to extrapolate their volume. We found that objective quantification of KPs correlated with inflammatory cell counts in the anterior chamber.


Asunto(s)
Uveítis Anterior , Uveítis , Femenino , Humanos , Adulto , Tomografía de Coherencia Óptica/métodos , Uveítis Anterior/diagnóstico por imagen , Estudios Prospectivos , Uveítis/diagnóstico , Inflamación
13.
JAMA Ophthalmol ; 141(10): 956-964, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37676684

RESUMEN

Importance: Calcium channel blocker (CCB) use has been associated with an increased risk of glaucoma in exploratory studies. Objective: To examine the association of systemic CCB use with glaucoma and related traits among UK Biobank participants. Design, Setting, and Participants: This population-based cross-sectional study included UK Biobank participants with complete data (2006-2010) for analysis of glaucoma status, intraocular pressure (IOP), and optical coherence tomography (OCT)-derived inner retinal layer thicknesses. Data analysis was conducted in January 2023. Exposure: Calcium channel blocker use was assessed in a baseline touchscreen questionnaire and confirmed during an interview led by a trained nurse. Main Outcomes and Measures: The primary outcome measures included glaucoma status, corneal-compensated IOP, and 2 OCT-derived inner retinal thickness parameters (macular retinal nerve fiber layer [mRNFL] and macular ganglion cell-inner plexiform layer [mGCIPL] thicknesses). We performed logistic regression and linear regression analyses to test for associations with glaucoma status and IOP and OCT-derived inner retinal thickness parameters, respectively. Results: This study included 427 480 adults. Their median age was 58 (IQR, 50-63) years, and more than half (54.1%) were women. There were 33 175 CCB users (7.8%). Participants who had complete data for glaucoma status (n = 427 480), IOP (n = 97 100), and OCT-derived inner retinal layer thicknesses (n = 41 023) were eligible for respective analyses. After adjustment for key sociodemographic, medical, anthropometric, and lifestyle factors, use of CCBs (but not other antihypertensive agents) was associated with greater odds of glaucoma (odds ratio [OR], 1.39 [95% CI, 1.14 to 1.69]; P = .001). Calcium channel blocker use was also associated with thinner mGCIPL (-0.34 µm [95% CI, -0.54 to -0.15 µm]; P = .001) and mRNFL (-0.16 µm [95% CI, -0.30 to -0.02 µm]; P = .03) thicknesses but not IOP (-0.01 mm Hg [95% CI, -0.09 to 0.07 mm Hg]; P = .84). Conclusions and Relevance: In this study, an adverse association between CCB use and glaucoma was observed, with CCB users having, on average, 39% higher odds of glaucoma. Calcium channel blocker use was also associated with thinner mGCIPL and mRNFL thicknesses, providing a structural basis that supports the association with glaucoma. The lack of association of CCB use with IOP suggests that an IOP-independent mechanism of glaucomatous neurodegeneration may be involved. Although a causal relationship has not been established, CCB replacement or withdrawal may be considered should glaucoma progress despite optimal care.


Asunto(s)
Bloqueadores de los Canales de Calcio , Glaucoma , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Transversales , Bancos de Muestras Biológicas , Biobanco del Reino Unido , Células Ganglionares de la Retina , Glaucoma/fisiopatología
14.
Ophthalmol Sci ; 3(3): 100377, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37701373
15.
Transl Vis Sci Technol ; 12(7): 3, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37395705

RESUMEN

Purpose: Investigate the association between the optical coherence tomography angiography (OCTA) metrics derived from different analysis programs to understand the comparability of studies using these different approaches. Methods: Secondary analysis of a prospective observational study (March 2018-September 2021). Forty-four right eyes and 42 left eyes from 44 patients were included. Patients were either undergoing upper gastrointestinal surgery with a critical care stay planned or were already in the critical care unit with sepsis. OCTA scans were obtained in an ophthalmology department or critical care setting. Fourteen OCTA metrics were compared within and between the programs, and agreement was measured by Pearson's R coefficient and intraclass correlation coefficient. Results: Correlation was highest between all Heidelberg metrics and Fractalyse (all >0.84), and lowest between Matlab skeletonized or foveal avascular zone metrics and all other measures (e.g., skeletal fractal dimension and vessel density at -0.02). Agreement between eyes was moderate to excellent in all metrics (0.60-0.90). Conclusions: The significant variability between metrics and programs used for OCTA analysis demonstrates that they are not interchangeable and supports a recommendation for perfusion density metrics to be reported as standard. Translational Relevance: Agreement between different OCTA analyses is variable and not interchangeable. The high agreement between non-skeletonized vessel density metrics suggests that these should be routinely reported.


Asunto(s)
Mácula Lútea , Vasos Retinianos , Humanos , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Reproducibilidad de los Resultados
16.
Transl Vis Sci Technol ; 12(7): 19, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37477933

RESUMEN

Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx. Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (±7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD. Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test-retest variability in iAMD (95% confidence interval [CI] ICC of 0.79-0.89 and 0.78-0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55-0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls. Translational Relevance: Expected levels of test-retest variability and discriminatory power of the AdaptDx and MAIA devices in a clinical study setting must be considered when designing future trials for people with AMD.


Asunto(s)
Degeneración Macular , Pruebas del Campo Visual , Humanos , Adaptación a la Oscuridad , Estudios Transversales
18.
Transl Vis Sci Technol ; 12(5): 1, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-37126336

RESUMEN

Purpose: This study was designed to determine if point analysis of the Humphrey visual field (HVF) is an effective outcome measure for people with idiopathic intracranial hypertension (IIH) compared with mean deviation (MD). Methods: Using the IIH Weight Trial data, we performed a pointwise analysis of the numerical retinal sensitivity. We then defined a medically treated cohort as having MDs between -2 dB and -7 dB and calculated the number of points that would have the ability to change by 7 dB. Results: The HVF 24-2 mean ± SD MD in the worse eye was -3.5 ± 1.1 dB (range, -2.0 to -6.4 dB). Total deviation demonstrated a preference for the peripheral and blind spot locations to be affected. Points between 0 dB and -10 dB demonstrated negligible ability to improve, compared with those between -10 dB and -25 dB. For the evaluation of the feasibility for a potential medical intervention trial, only 346 points were available for analysis between -10 dB and -25 dB bilaterally, compared with 4123 points in baseline sensitivities of 0 to -10 dB. Conclusions: Patients with IIH have mildly affected baseline sensitivities in the visual field based on HVF analyzer findings, and the majority of points do not show substantial change over 24 months in the setting of a randomized clinical trial. Most patients with IIH who are eligible for a medical treatment trial generally have the mildest affected baseline sensitivities. In such patients, pointwise analysis offers no advantage over MD in detection of visual field change.


Asunto(s)
Seudotumor Cerebral , Humanos , Seudotumor Cerebral/diagnóstico , Seudotumor Cerebral/tratamiento farmacológico , Campos Visuales , Pruebas del Campo Visual
19.
J Vis ; 23(4): 2, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-37014658

RESUMEN

Spatial summation of perimetric stimuli has been used to derive conclusions about the spatial extent of retinal-cortical convergence, mostly from the size of the critical area of summation (Ricco's area, RA) and critical number of retinal ganglion cells (RGCs). However, spatial summation is known to change dynamically with stimulus duration. Conversely, temporal summation and critical duration also vary with stimulus size. Such an important and often neglected spatiotemporal interaction has important implications for modeling perimetric sensitivity in healthy observers and for formulating hypotheses for changes measured in disease. In this work, we performed experiments on visually heathy observers confirming the interaction of stimulus size and duration in determining summation responses in photopic conditions. We then propose a simplified computational model that captures these aspects of perimetric sensitivity by modelling the total retinal input, the combined effect of stimulus size, duration, and retinal cones-to-RGC ratio. We additionally show that, in the macula, the enlargement of RA with eccentricity might not correspond to a constant critical number of RGCs, as often reported, but to a constant critical total retinal input. We finally compare our results with previous literature and show possible implications for modeling disease, especially glaucoma.


Asunto(s)
Pruebas del Campo Visual , Campos Visuales , Humanos , Pruebas del Campo Visual/métodos , Retina/fisiología , Células Ganglionares de la Retina/fisiología , Células Fotorreceptoras Retinianas Conos/fisiología
20.
Am J Ophthalmol ; 251: 143-155, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36813144

RESUMEN

PURPOSE: To compare visual field (VF) progression between glaucoma patients receiving cataract surgery alone (CS) or with a Hydrus microstent (CS-HMS). DESIGN: Post hoc analysis of VF data from the HORIZON multicenter randomized controlled trial. METHODS: A total of 556 patients with glaucoma and cataract were randomized 2:1 to either CS-HMS (369) or CS (187) and followed up for 5 years. VF was performed at 6 months and then every year after surgery. We analyzed data for all participants with at least 3 reliable VFs (false positives < 15%). Average between-group difference in rate of progression (RoP) was tested using a Bayesian mixed model and a 2-sided Bayesian P value <.05 (main outcome). A multivariable model measured the effect of intraocular pressure (IOP). A survival analysis compared the probability of global VF sensitivity dropping by predefined cutoffs (2.5, 3.5, 4.5, and 5.5 dB) from baseline. RESULTS: Data from 352 eyes in the CS-HMS arm and 165 in the CS arm were analyzed (2966 VFs). The mean RoP was -0.26 dB/y (95% credible interval -0.36, -0.16) for CS-HMS and -0.49 dB/y (95% credible interval -0.63, -0.34) for CS. This difference was significant (P = .0138). The difference in IOP only explained 17% of the effect (P < .0001). Five-year survival analysis showed an increased probability of VF worsening by 5.5 dB (P = .0170), indicating a greater proportion of fast progressors in the CS arm. CONCLUSIONS: CS-HMS has a significant effect on VF preservation in glaucoma patients compared with CS alone, reducing the proportion of fast progressors.


Asunto(s)
Catarata , Glaucoma , Humanos , Campos Visuales , Teorema de Bayes , Agudeza Visual , Glaucoma/cirugía , Presión Intraocular , Progresión de la Enfermedad , Pruebas del Campo Visual , Trastornos de la Visión , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...