Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Helicobacter ; 29(1): e13056, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38402559

RESUMEN

BACKGROUND AND AIMS: This study aimed to validate Helicobacter pylori serological and pepsinogen (PG) assays for detecting infection and gastric neoplasm. METHODS: Individuals who underwent serum Chorus H. pylori and HBI PG assays were included from May to September 2023. The GastroPanel test was performed using the same blood sample. HBI assay findings were interpreted with the ABC method using the criteria of corpus atrophy (PG I ≤ 70 ng/mL & I/II ≤3) and advanced corpus atrophy (PG I ≤ 30 ng/mL & I/II ≤2). RESULTS: A total of 144 H. pylori-infected and 184 non-infected Koreans were analyzed. The Chorus test (sensitivity 97.2%, specificity 89.1%) showed higher area under the curve (0.993 vs. 0.972, p = 0.003) than the GastroPanel test (sensitivity 95.8%, specificity 86.4%). Using the GastroSoft application, the incidence of gastric neoplasms was highest in the corpus atrophy group (50%), followed by the low acid-output (25.8%), H. pylori infection (11.6%), and antral atrophy (9.1%) groups. There were no gastric neoplasms in the normal and high acid output groups. Using the ABC method, the incidence of gastric neoplasms was highest in the corpus atrophy groups (23.8% in Groups C and D), followed by Group B (12.3%) and Group A (2.4%). Corpus atrophy interpreted with the GastroSoft showed poor agreement (k = 0.225) with corpus atrophy interpreted with the ABC method, whereas it showed excellent agreement (k = 0.854) with advanced corpus atrophy. CONCLUSIONS: Although the Chorus test was more accurate than the GastroPanel test, both assays discriminated high-risk individuals by detecting atrophy or infection. There were no gastric neoplasms in the normal or high acid-output groups (GastroSoft application), and gastric neoplasm incidence was lowest in Group A (ABC method). Corpus atrophy determined by GastroSoft application is more consistent with advanced corpus atrophy determined by the ABC method than is corpus atrophy.


Asunto(s)
Infecciones por Helicobacter , Helicobacter pylori , Neoplasias Gástricas , Humanos , Pepsinógeno A , Estudios Prospectivos , Infecciones por Helicobacter/diagnóstico , Atrofia
2.
Diagnostics (Basel) ; 14(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38275478

RESUMEN

We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected. No differences were observed in Ct values, except for the samples obtained on the day of symptom onset. The diagnostic sensitivity and specificity of the oral swabs were 75.0 and 100.0%, respectively, whereas those of the nasal swabs were 85.0 and 98.0%, respectively. The sensitivity was higher in samples with a high viral load collected earlier than those collected later, although the difference was not significant. False-negative results were confirmed in all samples with a Ct value ≥ 30.0. These results indicate that tests using oral and nasal swabs are helpful for diagnosing acute symptomatic cases with suspected high viral loads. Our tests exhibited relatively low sensitivity but high specificity rates, indicating the need to assess negative antigen test results.

3.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38000045

RESUMEN

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Recuento de Células Sanguíneas , Enfermedades Hematológicas/diagnóstico , Leucocitos , Recuento de Leucocitos
4.
Diagnostics (Basel) ; 13(14)2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37510116

RESUMEN

We explored the utility of novel biomarkers, presepsin and interferon-λ3 (IFN-λ3), for predicting disease severity and clinical outcomes in hospitalized Coronavirus (COVID-19) patients. In a total of 55 patients (non-critical, n = 16; critical, n = 39), presepsin and IFN-λ3 were compared with sequential organ failure assessment (SOFA) scores and age. Disease severity and clinical outcomes (in-hospital mortality, intensive care unit admission, ventilator use, and kidney replacement therapy) were analyzed using receiver operating characteristic (ROC) curves. In-hospital mortality was also analyzed using the Kaplan-Meier method with hazard ratios (HR). SOFA scores, age, presepsin, and IFN-λ3 predicted disease severity comparably (area under the curve [AUC], 0.67-0.73). SOFA score and IFN-λ3 predicted clinical outcomes comparably (AUC, 0.68-0.88 and 0.66-0.74, respectively). Presepsin predicted in-hospital mortality (AUC = 0.74). The combination of presepsin and IFN-λ3 showed a higher mortality risk than SOFA score or age (HR [95% confidence interval, CI], 6.7 [1.8-24.1]; 3.6 [1.1-12.1]; 2.8 [0.8-9.6], respectively) and mortality rate further increased when presepsin and IFN-λ3 were added to SOFA scores or age (8.5 [6.8-24.6], 4.2 [0.9-20.6], respectively). In the elderly (≥65 years), in-hospital mortality rate was significantly higher when both presepsin and IFN-λ3 levels increased than when either one or no biomarker level increased (88.9% vs. 14.3%, p < 0.001). Presepsin and IFN-λ3 predicted disease severity and clinical outcomes in hospitalized COVID-19 patients. Both biomarkers, whether alone or added to the clinical assessment, could be useful for managing COVID-19 patients, especially the elderly.

5.
Ann Lab Med ; 43(3): 290-294, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36544341

RESUMEN

While numerous studies have evaluated humoral responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, data on the cellular responses to these vaccines remain sparse. We evaluated T cell responses to ChAdOx1-nCoV-19 and BNT162b2 vaccinations using an interferon gamma (IFN-γ) release assay (IGRA). ChAdOx1-nCoV-19- and BNT162b2-vaccinated participants initially showed stronger T cell responses than unvaccinated controls. The T cell response decreased over time and increased substantially after the administration of a BNT162b2 booster dose. Changes in the T cell response were less significant than those in the anti-receptor-binding domain IgG antibody titer. The study results can serve as baseline data for T cell responses after SARS-CoV-2 vaccination and suggest that the IGRA can be useful in monitoring immunogenicity.


Asunto(s)
COVID-19 , ChAdOx1 nCoV-19 , Humanos , Vacuna BNT162 , Vacunas contra la COVID-19 , COVID-19/prevención & control , SARS-CoV-2 , Vacunación , Anticuerpos Antivirales
6.
Front Med (Lausanne) ; 9: 954114, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36072944

RESUMEN

Presepsin is a highly specific biomarker for diagnosing bacterial infections, but its clinical usefulness is not well validated. A retrospective cross-sectional study was conducted. Among the patients suspected bacterial infection or fulfilled the criteria of systemic inflammatory response syndrome (SIRS) and patients who underwent blood culture, presepsin, procalcitonin (PCT), and C-reactive protein (CRP) at the same time were included. Receiver operating characteristic (ROC) curve analysis and logistic regression were used to compare performance of three biomarkers. A total of 757 patients were enrolled, including 256 patients (33.8%) with culture-proven bacterial infection and 109 patients (14.4%) with bacteremia. The 28-day mortality rate was 8.6%. ROC curve analysis revealed that the area under the curve (AUC) of PCT was higher than that of presepsin for both culture-proven bacterial infection (0.665 and 0.596, respectively; p = 0.003) and bacteremia (0.791 and 0.685; p < 0.001). In contrast, AUC of PCT for 28-day mortality was slower than presepsin (0.593 and 0.720; p = 0.002). In multivariable logistic regression analysis, PCT showed the highest ORs for culture-proven bacterial infection (OR 2.23, 95% CI 1.55-3.19; p < 0.001) and for bacteremia (OR 5.18, 95% CI 3.13-8.56; p < 0.001), while presepsin showed the highest OR for 28-day mortality (OR 3.31, 95% CI 1.67-6.54; p < 0.001). CRP did not show better performance than PCT or presepsin in any of the analyses. PCT showed the best performance predicting culture-proven bacterial infection and bacteremia, while presepsin would rather be useful as a prognostic marker.

7.
Diagnostics (Basel) ; 12(8)2022 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-36010280

RESUMEN

The newly developed Axis-Shield clinical chemistry heparin-binding protein (HBP) assay (Axis-Shield Diagnostics Ltd., Dundee, Scotland) can be applied to fully automated platforms. We aimed to establish a reference interval (RI) of HBP using the Axis-Shield HBP assay, and to evaluate the analytical performance of this assay. An RI was established in 212 sodium citrated plasma samples using the non-parametric method (2.5th and 97.5th percentiles). Precision, linearity, and carry-over were evaluated according to the Clinical and Laboratory Standards Institute guidelines. The RI of HBP was between 5.3 ng/mL and 171.0 ng/mL, which could be applied regardless of gender and age. Percentage coefficients of variations (%CVs) of repeatability and within-laboratory precision were 4.9% and 6.3%, respectively, for low-concentration control and 1.6% and 3.0%, respectively, for high-concentration control. The linearity was excellent (coefficient of determination (R2) = 0.99), and the carry-over rate was negligible (0.05%). This is the first study to establish an RI of HBP using the newly developed and fully automated Axis-Shield HBP assay. The Axis-Shield HBP assay showed an acceptable level of analytical performance and could be used to measure HBP concentrations effectively in routine clinical practice. Further studies are awaited to evaluate the clinical utility of HBP using this automated assay.

8.
J Clin Med ; 11(15)2022 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-35893414

RESUMEN

The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation is the most commonly used equation for estimated glomerular filtration rate (eGFR). Recently, the European Kidney Function Consortium (EKFC) announced a full-age spectrum equation, and the CKD-EPI announced the CKD-EPI refit equations (CKD-EPI-R). We compared CKD-EPI, EKFC, and CKD-EPI-R equations in a large-scale Korean population and investigated their potential implications for CKD prevalence. In a total of 106,021 individuals who received annual check-ups from 2018 to 2020, we compared the eGFR equations according to the Clinical and Laboratory Standards Institute guidelines. Weighted kappa (κ) agreement was used to compare the potential implications for CKD prevalence across the equations. The median value of eGFR tended to increase in the order of EKFC, CKD-EPI, and CKD-EPI-R equations (92.4 mL/min/1.73 m2, 96.0 mL/min/1.73 m2, and 100.0 mL/min/1.73 m2, respectively). The EKFC and CKD-EPI-R equations showed a very high correlation of eGFR and good agreement for CKD prevalence with CKD-EPI equation (r = 0.98 and 1.00; κ = 0.80 and 0.82, respectively). Compared with the CKD-EPI equation, the EFKC equation overestimated CKD prevalence (3.5%), and the CKD-EPI-R equation underestimated it (1.5%). This is the first study comparing CKD-EPI, EKFC, and CKD-EPI-R equations simultaneously. The EKFC and CKD-EPI-R equations were statistically interchangeable with CKD-EPI equations in this large-scale Korean population. The transition of eGFR equations, however, would lead to sizable changes in the CKD prevalence. To improve kidney health, in-depth discussion considering various clinical aspects is imperative for the transition of eGFR equations.

9.
Diagnostics (Basel) ; 12(6)2022 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-35741159

RESUMEN

BACKGROUND: Immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) wanes over time after vaccination. METHODS: We compared SARS-CoV-2 antibody levels in serial samples from 350 vaccinated individuals at 3 time points (3 weeks after the first or second dose and before the third dose) with 4 assays: GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS), Siemens SARS-CoV-2 IgG (sCOVG), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II), and an Immuno-On™ COVID-19 IgG test (Immuno-On IgG). Antibody levels by time, concordance between assays, and values from other tests corresponding to the percent inhibition results in cPASS were assessed. RESULTS: The median values at three time points were 49.31%, 90.87%, and 53.38% inhibition for cPASS, 5.39, 13.65, and 2.24 U/mL for sCOVG, 570.25, 1279.65, and 315.80 AU/mL for CoV-2 IgG II, and 223.22, 362.20, and 62.20 relative units (RU) for Immuno-On IgG. The concordance with cPASS at each time point ranged from 0.735 to 0.984, showing the highest concordance in the second sample and lowest concordance in the third in all comparative tests. The values corresponded to 30% inhibition, and the cutoffs of cPASS, were 2.02 U/mL, 258.6 AU/mL, and 74.2 RU for each test. Those for 50%, 70%, and 90% inhibition were 3.16, 5.66, and 8.26 U/mL for sCOVG, while they were 412.5, 596.9, and 1121.6 AU/mL for CoV-2 IgG II and 141.8, 248.92, and 327.14 RU for Immuno-On IgG. CONCLUSIONS: This study demonstrated the dynamic changes in antibody values at different time points using four test systems and is expected to provide useful baseline data for comparative studies and standardization efforts in the future.

10.
Front Cell Infect Microbiol ; 12: 822599, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35493733

RESUMEN

For the clinical application of semi-quantitative anti-SARS-CoV-2 antibody tests, the analytical performance and titer correlation of the plaque reduction neutralization test (PRNT) need to be investigated. We evaluated the analytical performance and PRNT titer-correlation of one surrogate virus neutralization test (sVNT) kit and three chemiluminescent assays. We measured the total antibodies for the receptor-binding domain (RBD) of the spike protein, total antibodies for the nucleocapsid protein (NP), and IgG antibodies for the RBD. All three chemiluminescent assays showed high analytical performance for the detection of SARS-CoV-2 infection, with a sensitivity ≥ 98% and specificity ≥ 99%; those of the sVNT were slightly lower. The representativeness of the neutralizing activity of PRNT ND50 ≥ 20 was comparable among the four immunoassays (Cohen's kappa ≈ 0.80). Quantitative titer correlation for high PRNT titers of ND50 ≥ 50, 200, and 1,000 was investigated with new cut-off values; the anti-RBD IgG antibody kit showed the best performance. It also showed the best linear correlation with PRNT titer in both the acute and convalescent phases (Pearson's R 0.81 and 0.72, respectively). Due to the slowly waning titer of anti-NP antibodies, the correlation with PRNT titer at the convalescent phase was poor. In conclusion, semi-quantitative immunoassay kits targeting the RBD showed neutralizing activity that was correlated by titer; measurement of anti-NP antibodies would be useful for determining past infections.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , COVID-19/diagnóstico , Humanos , Inmunoensayo , Pruebas de Neutralización , Proteínas de la Nucleocápside , SARS-CoV-2
11.
J Ginseng Res ; 46(1): 126-137, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35058729

RESUMEN

BACKGROUND: Nonalcoholic steatohepatitis (NASH) is one of the main chronic liver diseases. NASH is identified by lipid accumulation, inflammation, and fibrosis. Jinan Red Ginseng (JRG) and licorice have been widely used because of their anti-inflammatory and hepatoprotective effects. Hence, this study assessed JRG and licorice extract mixtures' effects on NASH progression. METHODS: Palmitic acid (PA) and the western diet (WD) plus, high glucose-fructose water were used to induce in vitro and in vivo NASH. Mice were orally administered with JRG-single (JRG-S) and JRG-mixtures (JRG-M; JRG-S + licorice) at 0, 50, 100, 200 or 400 mg/kg/day once a day during the last half-period of diet feeding. RESULTS: JRG-S and JRG-M reduced NASH-related pathologies in WD-fed mice. JRG-S and JRG-M consistently decreased the mRNA level of genes related with inflammation, fibrosis, and lipid metabolism. The treatment of JRG-S and JRG-M also diminished the SREBP-1c protein levels and the p-AMPK/AMPK ratio. The FAS protein levels were decreased by JRG-M treatment both in vivo and in vitro but not JRG-S. CONCLUSION: JRG-M effectively reduced lipogenesis by modulating AMPK downstream signaling. Our findings suggest that this mixture can be used as a prophylactic or therapeutic alternative for the remedy of NASH.

12.
Vox Sang ; 117(3): 399-407, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34318939

RESUMEN

BACKGROUND AND OBJECTIVES: VISION Max (Ortho Clinical Diagnostics, Raritan, NJ) measures anti-A/B isoagglutinin titres using automated column agglutination technology (CAT). We compared tube test (TT) and CAT of VISION Max comprehensively, including failure mode and effect analysis (FMEA), turnaround time (TAT) and cost, and suggested modified CAT (MCAT). MATERIALS AND METHODS: For 100 samples (each 25 for blood type A, B and O with anti-A and anti-B), anti-A/B isoagglutinin titres were measured by TT and CAT (1:2-1:1024 dilution), as well as by MCAT (with agglutination at 1:32 dilution, then perform additional testing from 1:64 to 1:1024). We assessed the agreement and correlation between TT and CAT and compared FMEA (risk priority number [RPN] score), TAT (h:min:sec) and cost (US dollar, US $) among TT, CAT and MCAT. RESULTS: TT and CAT showed overall substantial agreement (k = 0.73) and high correlation (ρ ≥ 0.75) except blood type O with anti-A (ρ = 0.68). Compared with TT, CAT showed lower RPN scores in FMEA and similar TAT and cost (FMEA, 33,700 vs. 184,300; TAT, 15:23:00 vs. 14:26:40; cost, 1377.4 vs. 1312.4, respectively). Regarding FMEA, TAT and cost, MCAT was superior to CAT or TT (43,810; 13:28:00; 899.2, respectively). CONCLUSION: This is the first multidimensional analysis on VISION Max CAT for measuring anti-A/B isoagglutinin titres. The results of anti-A/B isoagglutinin titres by CAT were comparable with those of TT. MCAT would be a safe, time-saving and cost-effective alternative to TT and CAT in high-volume blood bank laboratories.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Hemaglutininas , Aglutinación , Anticuerpos , Tecnología
13.
Ann Lab Med ; 42(2): 249-257, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34635616

RESUMEN

BACKGROUND: Non-invasive clinical algorithms for the detection of liver fibrosis (LF) can reduce the need for liver biopsy (LB). We explored the implementation of two serum biomarkers, enhanced liver fibrosis (ELF) and Mac-2 binding protein glycosylation isomer (M2BPGi), in clinical algorithms for LF in chronic hepatitis B (CHB) patients. METHODS: Two clinical algorithms were applied to 152 CHB patients: (1) transient elastography (TE) followed by biomarkers (TE/ELF and TE/M2GPGi); (2) biomarker test followed by TE (ELF/TE and M2BPGi/TE). Using the cut-off value or index for the detection of advanced LF (TE≥F3; 9.8 in ELF and 3.0 in M2BPGi), LB was expected to be performed in cases with discordant TE and biomarker results. RESULTS: In both algorithms, the expected number of LBs was lower when using M2BPGi than when using ELF (TE/ELF or ELF/TE, 13.2% [N=20]; TE/M2BPGi or M2BPGi/TE, 9.9% [N=15]), although there was no statistical difference (P=0.398). In the TE low-risk group (TE≤F2), the discordance rate was significantly lower in the TE/M2BPGi approach than in the TE/ELF approach (1.5% [2/136] vs. 11.0% [15/136], P=0.002). In the biomarker low-risk group, there was no significant difference between the ELF/TE and M2BPGi/TE approaches (3.9% [5/126] vs. 8.8% [13/147], P=0.118). CONCLUSIONS: Both ELF and M2BPGi can be implemented in non-invasive clinical algorithms for assessing LF in CHB patients. Given the lowest possibility of losing advanced LF cases in the low-risk group when using the TE/M2BPGi approach, this combination seems useful in clinical practice.


Asunto(s)
Hepatitis B Crónica , Algoritmos , Biopsia , Glicosilación , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/diagnóstico , Humanos , Cirrosis Hepática/diagnóstico
14.
Ann Lab Med ; 42(1): 63-70, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34374350

RESUMEN

BACKGROUND: Recently, two fully automated immunoassays for antinuclear antibody (ANA) screening were introduced: EliA CTD Screen (Thermo Fisher Scientific, Freiburg, Germany) and QUANTA Flash CTD Screen Plus (Inova Diagnostics, San Diego, USA). We evaluated their clinical performance in comparison with the indirect immunofluorescence assay (IIFA) and analyzed samples with discrepant results. METHODS: In total, 406 serum samples (206 from patients undergoing routine checkups and 200 from rheumatology clinic patients) were assayed using EliA, QUANTA Flash, and IIFA. We evaluated assay concordance and agreement and confirmed the presence of anti-extractable nuclear antigen (ENA) antibodies in samples with discrepant automated immunoassay and IIFA results. Additionally, we compared the clinical performance of each assay in diagnosing ANA-associated rheumatic disease (AARD) and adjusted the cut-off values. RESULTS: In rheumatology clinic samples, the concordance and agreement were 91.5% and strong between EliA and QUANTA Flash, 79.0% and weak between EliA and IIFA, and 80.5% and moderate between QUANTA Flash and IIFA, respectively. In automated immunoassay-positive, IIFA-negative samples (N=15), all anti-ENA antibodies detected (6/15) were anti-Sjögren's syndrome antigen A/Ro (Ro60) antibodies. The automated immunoassays and IIFA showed high accuracy for diagnosing AARD, and adjusted cut-off values improved their sensitivities (EliA with 0.56 ratio, 82.9% sensitivity; QUANTA Flash with 9.7 chemiluminescent units, 87.8% sensitivity). CONCLUSIONS: The two automated immunoassays showed reliable performance compared with IIFA and can be efficiently used with the IIFA in clinical immunology laboratories. Clinical cut-off values can be adjusted according to the workflow in each laboratory.


Asunto(s)
Anticuerpos Antinucleares , Tamizaje Masivo , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Inmunoensayo , Sensibilidad y Especificidad
15.
Microbiol Spectr ; 9(3): e0120221, 2021 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-34817223

RESUMEN

Multiple vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed and administered to mitigate the coronavirus disease 2019 (COVID-19) pandemic. We assessed the humoral response of BNT162b2 and ChAdOx1 nCoV-19 using Siemens SARS-CoV-2 IgG (sCOVG; cutoff of ≥1.0 U/ml), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; cutoff of ≥50.0 AU/ml), and GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS; cutoff of ≥30% inhibition). We collected 710 serum samples (174 samples after BNT162b2 and 536 samples after ChAdOx1 nCoV-19). Venous blood was obtained 3 weeks after first and second vaccinations. In both vaccines, sCOVG, CoV-2 IgG II, and cPASS showed a high seropositive rate (>95.7%) except for cPASS after the first vaccination with ChAdOx1 nCoV-19 (68.8%). Using sCOVG and CoV-2 IgG II, the ratios of antibody value (second/first) increased 10.6- and 11.4-fold in BNT162b2 (first 14.1, second 134.8 U/ml; first 1,416.2, second 14,326.4 AU/ml) and 2.3- and 2.0-fold in ChAdOx1 nCoV-19 (first 4.0, second 9.1 U/ml; first 431.0, second 9,744.0 AU/ml). cPASS-positive results indicated a very high concordance rate with sCOVG and CoV-2 IgG II (>98%), whereas cPASS-negative results showed a relatively low concordance rate (range of 22.2% to 66.7%). To predict cPASS positivity, we suggested additional cutoffs for sCOVG and CoV-2 IgG II at 2.42 U/ml and 284 AU/ml, respectively. In conclusion, BNT162b2 and ChAdOx1 nCoV-19 evoked robust humoral responses. sCOVG and CoV-2 IgG II showed a very strong correlation with cPASS. sCOVG and CoV-2 IgG II may predict the presence of neutralizing antibodies against SARS-CoV-2. IMPORTANCE The Siemens severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG (sCOVG; Siemens Healthcare Diagnostics Inc., NY, USA) and Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; Abbott Laboratories, Sligo, Ireland), which are automated, quantitative SARS-CoV-2-binding antibody assays, have been recently launched. This study aimed to evaluate the humoral immune response of BNT162b2 and ChAdOx1 nCoV-19 vaccines using sCOVG and CoV-2 IgG II and compare the quantitative values with the results of the GenScript surrogate virus neutralization test (cPASS; GenScript, USA Inc., NJ, USA). Our findings demonstrated that both BNT162b2 and ChAdOx1 nCoV-19 elicited a robust humoral response after the first vaccination and further increased after the second vaccination. sCOVG and CoV-2 IgG II showed a strong correlation, and the concordance rates among sCOVG, CoV-2 IgG II, and cPASS were very high in the cPASS-positive results. The additional cutoff sCOVG and CoV-2 IgG II could predict the results of cPASS.


Asunto(s)
Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Vacunas contra la COVID-19/inmunología , COVID-19/inmunología , Inmunidad Humoral , Vacunación , Adulto , Vacuna BNT162/inmunología , COVID-19/prevención & control , ChAdOx1 nCoV-19/inmunología , Femenino , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Pruebas Serológicas/métodos , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto Joven
16.
Artículo en Inglés | MEDLINE | ID: mdl-34208462

RESUMEN

Asymptomatic/mildly symptomatic coronavirus disease 2019 (COVID-19) patients produce a considerable amount of virus and transmit severe acute respiratory syndrome virus 2 (SARS-CoV-2) through close contact. Preventing in-hospital transmission of SARS-CoV-2 is challenging, since symptom-based screening protocols may miss asymptomatic/mildly symptomatic patients. In particular, dental healthcare workers (HCWs) are at high risk of exposure, as face-to-face contact and exposure to oral secretions is unavoidable. We report exposure of HCWs during dental procedures on a mild symptomatic COVID-19 patient. A 32-year-old male visited a dental clinic at a tertiary care hospital. He experienced mild cough, which started three days before the dental visit, but did not report his symptom during the entrance screening. He underwent several dental procedures and imaging for orthognathic surgery without wearing a mask. Seven HCWs were closely exposed to the patient during dental procedures that could have generated droplets and aerosols. One HCW had close contact with the patient during radiologic exams, and seven HCWs had casual contact. All HCWs wore particulate filtering respirators with 94% filter capacity and gloves, but none wore eye protection or gowns. The next day, the patient experienced dysgeusia and was diagnosed with COVID-19 with high viral load. All HCWs who had close contact with the patient were quarantined for 14 days, and polymerase chain reaction and antibody tests for SARS-CoV-2 were negative. This exposure event suggests the protective effect of particulate filtering respirators in dental clinics. The recommendations of different levels of personal protective equipment (PPE) for dental HCWs according to the procedure types should be established according to the planned procedure, the risk of COVID-19 infection of the patient, and the outbreak situation of the community.


Asunto(s)
COVID-19 , Clínicas Odontológicas , Adulto , Personal de Salud , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Masculino , Equipo de Protección Personal , SARS-CoV-2 , Ventiladores Mecánicos
17.
Int J Lab Hematol ; 43(5): 1191-1197, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33460254

RESUMEN

INTRODUCTION: We evaluated the analytical performance of CoaguChek Pro II (Roche Diagnostics GmbH, Mannheim, Germany), a new point-of-care device measuring the international normalized ratio (INR) values, in comparison with CoaguChek XS Plus (Roche Diagnostics GmbH) and STA-R Max using STA-Neoplastine CI Plus (Diagnostica Stago SAS, Asnières-sur-Seine, France). METHODS: The precision of Pro II was analyzed, according to the Clinical and Laboratory Standards Institute guidelines (CLSI POCT14-A2 and EP15-A3). In 105 clinical samples, the Pro II INR values were compared with those of XS Plus and STA-R Max using STA-Neoplastine CI Plus (CLSI EP09-A3 and EP35). We also compared the Pro II INR values between capillary blood (CB) and venous blood (VB; CLSI EP35). RESULTS: The precision of Pro II was acceptable (within-run and between-run CV%: 2.71% and 3.28% at normal level; 1.52% and 4.47% at abnormal level, respectively). The Pro II INR values showed very high correlation and almost perfect agreement with those of XS Plus and STA-R Max using STA-Neoplastine CI Plus (r = .97 and κ = .94; r = .95 and κ = .91). The mean difference between Pro II and STA-R Max using STA-Neoplastine CI Plus increased as INR values increased, with 60% of samples showing differences >0.5 in the supratherapeutic range. The Pro II INR values showed very high correlation between CB and VB (r = .98). CONCLUSION: Pro II INR values are accurate and reliable using both CB and VB; however, they should be confirmed by laboratory analyzers in the supratherapeutic range.


Asunto(s)
Coagulación Sanguínea , Relación Normalizada Internacional/instrumentación , Sistemas de Atención de Punto , Pruebas de Coagulación Sanguínea/instrumentación , Pruebas de Coagulación Sanguínea/métodos , Femenino , Humanos , Relación Normalizada Internacional/métodos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
18.
Clin Chem Lab Med ; 59(6): 1099-1106, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-33470955

RESUMEN

OBJECTIVES: Vision Pro (West Medica, Perchtoldsdorf, Austria) is a recently developed digital morphology analyzer. We evaluated the performance of Vision Pro on white blood cell (WBC) differentials. METHODS: In a total of 200 peripheral blood smear samples (100 normal and 100 abnormal samples), WBC preclassification and reclassification by Vision Pro were evaluated and compared with manual WBC count, according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: The overall sensitivity was high for normal WBCs and nRBCs (80.1-98.0%). The overall specificity and overall efficiency were high for all cell classes (98.1-100.0% and 97.7-99.9%, respectively). The absolute values of mean differences between Vision Pro and manual count ranged from 0.01 to 1.31. In leukopenic samples, those values ranged from 0.09 to 2.01. For normal WBCs, Vision Pro preclassification and manual count showed moderate or high correlations (r=0.52-0.88) except for basophils (r=0.34); after reclassification, the correlation between Vision Pro and manual count was improved (r=0.36-0.90). CONCLUSIONS: This is the first study that evaluated the performance of Vision Pro on WBC differentials. Vision Pro showed reliable analytical performance on WBC differentials with improvement after reclassification. Vision Pro could help improve laboratory workflow.


Asunto(s)
Leucocitos , Proyectos de Investigación , Recuento de Células Sanguíneas , Recuento de Leucocitos , Estándares de Referencia
19.
Diagnostics (Basel) ; 12(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35054235

RESUMEN

The performance of platelet (PLT) counting in thrombocytopenic samples is crucial for transfusion decisions. We compared PLT counting and its reproducibility between Mindray BC-6800Plus (BC-6800P, Mindray, Shenzhen, China) and Sysmex XN-9000 (XN, Sysmex, Kobe, Japan), especially focused on thrombocytopenic samples. We analyzed the correlation and agreement of PLT-I channels in both analyzers and BC-6800P PLT-O mode and XN PLT-F channel in 516 samples regarding PLT counts. Ten thrombocytopenic samples (≤2.0 × 109/L by XN PLT-F) were measured 10 times to investigate the reproducibility with the desirable precision criterion, 7.6%. The correlation of BC-6800P PLT-I and XN PLT-I was arranged moderate to very high; but the correlation of BC-6800P PLT-O and XN PLT-F was arranged high to very high. Both BC-6800P PLT-I vs. XN PLT-I and BC-6800P PLT-O vs. XN PLT-F showed very good agreement (κ = 0.93 and κ = 0.94). In 41 discordant samples between BC-6800P PLT-O and XN PLT-F at transfusion thresholds, BC-6800P PLT-O showed higher PLT counts than XN-PLT-F, except the one case. BC-6800P PLT-O exceeded the precision criterion in one of 10 samples; but XN PLT-F exceeded it in six of 10 samples. BC-6800P would be a reliable option for PLT counting in thrombocytopenic samples with good reproducibility.

20.
Ann Lab Med ; 41(1): 60-67, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32829580

RESUMEN

BACKGROUND: Neutrophil gelatinase-associated lipocalin (NGAL) is a useful biomarker for acute kidney injury (AKI) prediction. However, studies on whether using both plasma NGAL (PNGAL) and urine NGAL (UNGAL) can improve AKI prediction are limited. We investigated the best approach to predict AKI in high-risk patients when using PNGAL and UNGAL together. METHODS: We enrolled 151 AKI suspected patients with one or more AKI risk factors. We assessed the diagnostic performance of PNGAL and UNGAL for predicting AKI according to chronic kidney disease (CKD) status by determining the areas under the receiver operating curve (AuROC). Independent predictors of AKI were assessed using univariate and multivariate logistic regression analyses. RESULTS: In the multivariate logistic regression analysis for all patients (N=151), Model 2 and 3, including PNGAL (P=0.012) with initial serum creatinine (S-Cr), showed a better AKI prediction power (R2=0.435, both) than Model 0, including S-Cr only (R2=0.390). In the non-CKD group (N=135), the AuROC of PNGAL for AKI prediction was larger than that of UNGAL (0.79 vs 0.66, P=0.010), whereas in the CKD group (N=16), the opposite was true (0.94 vs 0.76, P=0.049). CONCLUSIONS: PNGAL may serve as a useful biomarker for AKI prediction in high-risk patients. However, UNGAL predicted AKI better than PNGAL in CKD patients. Our findings provide guidance for selecting appropriate specimens for NGAL testing according to the presence of CKD in AKI high-risk patients.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Biomarcadores/sangre , Lipocalina 2/sangre , Anciano , Área Bajo la Curva , Biomarcadores/orina , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Lipocalina 2/orina , Modelos Logísticos , Masculino , Persona de Mediana Edad , Curva ROC , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...