Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Muscle Nerve ; 63(3): 421-429, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33290586

RESUMEN

BACKGROUND: Regenerative peripheral nerve interfaces (RPNIs) transduce neural signals to provide high-fidelity control of neuroprosthetic devices. Traditionally, rat RPNIs are constructed with ~150 mg of free skeletal muscle grafts. It is unknown whether larger free muscle grafts allow RPNIs to transduce greater signal. METHODS: RPNIs were constructed by securing skeletal muscle grafts of various masses (150, 300, 600, or 1200 mg) to the divided peroneal nerve. In the control group, the peroneal nerve was transected without repair. Endpoint assessments were conducted 3 mo postoperatively. RESULTS: Compound muscle action potentials (CMAPs), maximum tetanic isometric force, and specific muscle force were significantly higher for both the 150 and 300 mg RPNI groups compared to the 600 and 1200 mg RPNIs. Larger RPNI muscle groups contained central areas lacking regenerated muscle fibers. CONCLUSIONS: Electrical signaling and tissue viability are optimal in smaller as opposed to larger RPNI constructs in a rat model.


Asunto(s)
Miembros Artificiales , Electrodos Implantados , Músculos Isquiosurales/trasplante , Contracción Muscular/fisiología , Conducción Nerviosa/fisiología , Nervio Peroneo/fisiología , Potenciales de Acción , Animales , Electromiografía , Músculos Isquiosurales/inervación , Músculos Isquiosurales/patología , Músculos Isquiosurales/fisiología , Músculo Esquelético/inervación , Músculo Esquelético/patología , Músculo Esquelético/fisiología , Músculo Esquelético/trasplante , Nervios Periféricos , Ratas , Ratas Endogámicas F344 , Robótica , Relación Señal-Ruido
2.
J Neuroeng Rehabil ; 15(1): 108, 2018 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-30458876

RESUMEN

INTRODUCTION: Regenerative peripheral nerve interfaces (RPNIs) are biological constructs which amplify neural signals and have shown long-term stability in rat models. Real-time control of a neuroprosthesis in rat models has not yet been demonstrated. The purpose of this study was to: a) design and validate a system for translating electromyography (EMG) signals from an RPNI in a rat model into real-time control of a neuroprosthetic hand, and; b) use the system to demonstrate RPNI proportional neuroprosthesis control. METHODS: Animals were randomly assigned to three experimental groups: (1) Control; (2) Denervated, and; (3) RPNI. In the RPNI group, the extensor digitorum longus (EDL) muscle was dissected free, denervated, transferred to the lateral thigh and neurotized with the residual end of the transected common peroneal nerve. Rats received tactile stimuli to the hind-limb via monofilaments, and electrodes were used to record EMG. Signals were filtered, rectified and integrated using a moving sample window. Processed EMG signals (iEMG) from RPNIs were validated against Control and Denervated group outputs. RESULTS: Voluntary reflexive rat movements produced signaling that activated the prosthesis in both the Control and RPNI groups, but produced no activation in the Denervated group. Signal-to-Noise ratio between hind-limb movement and resting iEMG was 3.55 for Controls and 3.81 for RPNIs. Both Control and RPNI groups exhibited a logarithmic iEMG increase with increased monofilament pressure, allowing graded prosthetic hand speed control (R2 = 0.758 and R2 = 0.802, respectively). CONCLUSION: EMG signals were successfully acquired from RPNIs and translated into real-time neuroprosthetic control. Signal contamination from muscles adjacent to the RPNI was minimal. RPNI constructs provided reliable proportional prosthetic hand control.


Asunto(s)
Miembros Artificiales , Electromiografía/métodos , Regeneración Nerviosa , Procesamiento de Señales Asistido por Computador , Animales , Miembro Posterior/inervación , Masculino , Movimiento/fisiología , Músculo Esquelético/fisiología , Regeneración Nerviosa/fisiología , Nervios Periféricos/fisiología , Ratas
3.
J Reconstr Microsurg ; 32(3): 194-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26502083

RESUMEN

BACKGROUND: This study compared epimysial patch electrodes with intramuscular hook electrodes using monopolar and bipolar recording configurations. The purpose was to determine which strategy transduced muscle signals with better fidelity for control of myoelectric prostheses. METHODS: One of the two electrode styles, patch (n = 4) or hook (n = 6) was applied to the left extensor digitorum longus muscle in rats. Electrodes were evaluated at the time of placement and at monthly intervals for 4 months. Evaluations consisted of evoked electromyography signals from stimulation pulses applied to the peroneal and tibial nerves in both monopolar and bipolar recording configurations. RESULTS: Compared with hook electrodes, patch electrodes recorded larger signals of interest and minimized muscle tissue injury. A bipolar electrode configuration significantly reduced signal noise when compared with a monopolar configuration. CONCLUSION: Epimysial patch electrodes outperform intramuscular hook electrodes during chronic skeletal muscle implantation.


Asunto(s)
Estimulación Eléctrica/métodos , Electrodos , Miembro Posterior/inervación , Miembro Posterior/cirugía , Músculo Esquelético/inervación , Regeneración Nerviosa/fisiología , Nervios Periféricos/fisiología , Nervios Periféricos/cirugía , Animales , Electromiografía , Ratas , Ratas Endogámicas F344
4.
Artículo en Inglés | MEDLINE | ID: mdl-25570372

RESUMEN

Despite modern technological advances, the most widely available prostheses provide little functional recovery beyond basic grasping. Although sophisticated upper extremity prostheses are available, optimal prosthetic interfaces which give patients high-fidelity control of these artificial limbs are limited. We have developed a novel Regenerative Peripheral Nerve Interface (RPNI), which consists of a unit of free muscle that has been neurotized by a transected peripheral nerve. In conjunction with a biocompatible electrode on the muscle surface, the RPNI facilitates signal transduction from a residual peripheral nerve to a neuroprosthetic limb. The purpose of this study was to explore signal quality and reliability in an RPNI following an extended period of implantation. Following a 14-month maturation period, electromyographic signal generation was evaluated via electrical stimulation of the innervating nerve. The long-term RPNI was viable and healthy, as demonstrated by evoked compound muscle action potentials as well as histological tissue analysis. Signals exceeding 4 mV were successfully acquired and amplitudes were consistent across multiple repetitions of applied stimuli. There were no evident signs of muscle denervation, significant scar tissue, or muscle necrosis. This study provides further evidence that after a maturation period exceeding 1 year, reliable and consistent signals can still be acquired from an RPNI.


Asunto(s)
Regeneración Nerviosa/fisiología , Nervios Periféricos/fisiología , Procesamiento de Señales Asistido por Computador , Interfaz Usuario-Computador , Potenciales de Acción , Animales , Estimulación Eléctrica , Electrodos , Electromiografía , Masculino , Ratas Endogámicas F344 , Reproducibilidad de los Resultados
5.
Artículo en Inglés | MEDLINE | ID: mdl-25570963

RESUMEN

High-fidelity signal acquisition is critical for the fundamental control of a neuroprosthesis. Our group has developed a bio-artificial interface consisting of a muscle graft neurotized by a severed nerve in a rat hind limb model. This regenerative peripheral nerve interface (RPNI) permits nerve signal transmission, amplification, and detection via in situ electromyography (EMG). Our study examined the magnitude of signal interference from simultaneously contracting muscles adjacent to our muscle of interest. In eighteen F344 rats, the extensor digitorum longus (EDL) muscle was used to fabricate simulated RPNI constructs of various sizes in which the neurovascular pedicle was preserved, obviating the need for reinnervation or revascularization. After 3 weeks of recovery, in situ EMG testing was performed using electrical stimulation of the common peroneal nerve. A recording needle was placed in the EDL muscle with a reference/ground electrode in the contralateral toe webspace, comprising a monopolar recording configuration. The superficial peroneal nerve was transected to further isolate stimulation of the anterior compartment. Recordings from the EDL were performed before and after excision of the tibialis anterior (TA) and extensor hallucis longus (EHL) muscles. After TA/EHL excision, EDL compound muscle action potential (CMAP) peak-to-peak amplitudes were significantly lower by an average of 7.4±5.6(SD) mV, or 32±18%, (paired t(17)=-5.7, p<;0.0001). A significant positive linear correlation was seen between CMAP amplitude and EDL mass both before TA/EHL excision (r=0.68, n=18, p<;0.01) and after TA/EHL excision (r=0.79, n=18, p<;0.0001). EDL mass did not correlate with differences in CMAP amplitude or area caused by TA/EHL excision. Monopolar needle EMG recordings from the EDL muscle are significantly, but predictively, contaminated by concomitant muscular contractions in the anterior compartment of the rat hind limb. Further investigation of strategies to reduce this signal interference, including electrode choice or configuration, use of bioelectrical insulators, and filtering methods, is warranted to promote high-fidelity signal acquisition for prosthetic control.


Asunto(s)
Electromiografía , Miembro Posterior/fisiología , Nervios Periféricos/fisiología , Potenciales de Acción , Animales , Estimulación Eléctrica , Masculino , Músculo Esquelético/fisiología , Ratas , Ratas Endogámicas F344 , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA