Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(7)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38610854

RESUMEN

Background: Patent ductus arteriosus (PDA) is a prevalent congenital heart defect in premature infants, associated with significant morbidity and mortality. Accurate and timely diagnosis of PDA is crucial, given the vulnerability of this population. Methods: We introduce an artificial intelligence (AI)-based PDA diagnostic support system designed to assist medical professionals in diagnosing PDA in premature infants. This study utilized electronic health record (EHR) data from 409 premature infants spanning a decade at Severance Children's Hospital. Our system integrates a data viewer, data analyzer, and AI-based diagnosis supporter, facilitating comprehensive data presentation, analysis, and early symptom detection. Results: The system's performance was evaluated through diagnostic tests involving medical professionals. This early detection model achieved an accuracy rate of up to 84%, enabling detection up to 3.3 days in advance. In diagnostic tests, medical professionals using the system with the AI-based diagnosis supporter outperformed those using the system without the supporter. Conclusions: Our AI-based PDA diagnostic support system offers a comprehensive solution for medical professionals to accurately diagnose PDA in a timely manner in premature infants. The collaborative integration of medical expertise and technological innovation demonstrated in this study underscores the potential of AI-driven tools in advancing neonatal diagnosis and care.

2.
Sensors (Basel) ; 23(22)2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-38005621

RESUMEN

The limited availability of calorimetry systems for estimating human energy expenditure (EE) while conducting exercise has prompted the development of wearable sensors utilizing readily accessible methods. We designed an energy expenditure estimation method which considers the energy consumed during the exercise, as well as the excess post-exercise oxygen consumption (EPOC) using machine learning algorithms. Thirty-two healthy adults (mean age = 28.2 years; 11 females) participated in 20 min of aerobic exercise sessions (low intensity = 40% of maximal oxygen uptake [VO2 max], high intensity = 70% of VO2 max). The physical characteristics, exercise intensity, and the heart rate data monitored from the beginning of the exercise sessions to where the participants' metabolic rate returned to an idle state were used in the EE estimation models. Our proposed estimation shows up to 0.976 correlation between estimated energy expenditure and ground truth (root mean square error: 0.624 kcal/min). In conclusion, our study introduces a highly accurate method for estimating human energy expenditure during exercise using wearable sensors and machine learning. The achieved correlation up to 0.976 with ground truth values underscores its potential for widespread use in fitness, healthcare, and sports performance monitoring.


Asunto(s)
Metabolismo Energético , Ejercicio Físico , Adulto , Femenino , Humanos , Metabolismo Energético/fisiología , Ejercicio Físico/fisiología , Pruebas de Función Respiratoria , Prueba de Esfuerzo , Consumo de Oxígeno/fisiología
3.
Sensors (Basel) ; 21(13)2021 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-34283102

RESUMEN

In this study, based on multi-access edge computing (MEC), we provided the possibility of cooperating manufacturing processes. We tried to solve the job shop scheduling problem by applying DQN (deep Q-network), a reinforcement learning model, to this method. Here, to alleviate the overload of computing resources, an efficient DQN was used for the experiments using transfer learning data. Additionally, we conducted scheduling studies in the edge computing ecosystem of our manufacturing processes without the help of cloud centers. Cloud computing, an environment in which scheduling processing is performed, has issues sensitive to the manufacturing process in general, such as security issues and communication delay time, and research is being conducted in various fields, such as the introduction of an edge computing system that can replace them. We proposed a method of independently performing scheduling at the edge of the network through cooperative scheduling between edge devices within a multi-access edge computing structure. The proposed framework was evaluated, analyzed, and compared with existing frameworks in terms of providing solutions and services.


Asunto(s)
Nube Computacional , Ecosistema
4.
Neurourol Urodyn ; 40(1): 421-427, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33197046

RESUMEN

AIMS: To assess the possibility of the body impedance (BI) reflecting bladder volumes (BV) in pediatric patients, the BI signals are measured continuously with the equipment that we have developed and reported previously, during the filling phase of urodynamic study (UDS). METHODS: A total of 30 children (5-12 years old) are included in this prospective study. The equipment uses two dry electrodes embedded inside a strap to collect impedance and electrocardiogram signals. The factors affecting baseline BI and its decreases during UDS have been investigated. RESULTS: The median age is 6.1 years and BI is accurately measured in 27 out of 30 patients (90.0% accuracy). The median value of baseline BI is 1958 Ω. It is higher when they are older, equal to or taller than 125 cm, or non-neurogenic bladder patients. BI decreases as the bladder is filled with saline in 21 patients (77.8%), and remains constant in 6 patients (22.2%). The median age of the Decreased Group is significantly higher than that of Nondecreased Group (p = .036). Height of 125 cm or more is significant in the Decreased Group (p = .020). Heart rates also have been simultaneously measured and revealed a mild decrease during the filling phase. CONCLUSIONS: The baseline BI is affected by the height and age of the children. BI is effectively measured and reflects a change in the BV in older children who are taller than 125 cm, with a small device using a smartphone and a strap.


Asunto(s)
Impedancia Eléctrica/uso terapéutico , Vejiga Urinaria Neurogénica/terapia , Urodinámica/fisiología , Niño , Preescolar , Femenino , Humanos , Masculino , Estudios Prospectivos , Vejiga Urinaria Neurogénica/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...