Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Palliat Med Rep ; 3(1): 322-325, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36636613

RESUMEN

The syndrome of remitting seronegative symmetrical synovitis with pitting edema (RS3PE) is a rare diagnosis that is often missed due to lack of both definitive diagnostic criteria and awareness of the disease. This case report describes a patient with chronic lymphocytic leukemia whose diagnosis of RS3PE was possibly delayed due to concomitant treatment-related arthralgias. The pathophysiology, presentation, and treatment of RS3PE are discussed. Greater awareness of malignancy-related RS3PE is crucial from a palliative care perspective as typical opioid pain management will prove ineffective and delay appropriate treatment.

2.
Am J Physiol Endocrinol Metab ; 318(5): E779-E790, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32208001

RESUMEN

Glucagon's effect on hepatic glucose production (HGP), under hyperglycemic conditions, is time dependent such that after an initial burst of HGP, it slowly wanes. It is not known whether this is also the case under hypoglycemic conditions, where an increase in HGP is essential. This question was addressed using adrenalectomized dogs to avoid the confounding effects of other counterregulatory hormones. During the study, infusions of epinephrine and cortisol were given to maintain basal levels. Somatostatin and insulin (800 µU·kg-1·min-1) were infused to induce hypoglycemia. After 30 min, glucagon was infused at a basal rate (1 ng·kg-1·min-1, baGGN group, n = 5 dogs) or a rate eightfold basal (8 ng·kg-1·min-1, hiGGN group, n = 5 dogs) for 4 h. Glucose was infused to match the arterial glucose levels between groups (≈50 mg/dL). Our data showed that glucagon has a biphasic effect on the liver despite hypoglycemia. Hyperglucagonemia stimulated a rapid, transient peak in HGP (4-fold basal production) over ~60 min, which was followed by a slow reduction in HGP to a rate 1.5-fold basal. During the last 2 h of the experiment, hiGGN stimulated glucose production at a rate fivefold greater than baGGN (2.5 vs. 0.5 mg·kg-1·min-1, respectively), indicating a sustained effect of the hormone. Of note, the hypoglycemia-induced rises in norepinephrine and glycerol were smaller in hiGGN compared with the baGGN group despite identical hypoglycemia. This finding suggests that there is reciprocity between glucagon and the sympathetic nervous system such that when glucagon is increased, the sympathetic nervous response to hypoglycemia is downregulated.


Asunto(s)
Glucagón/farmacocinética , Gluconeogénesis/efectos de los fármacos , Hipoglucemia/metabolismo , Hígado/efectos de los fármacos , Sistema Nervioso Simpático/efectos de los fármacos , Adrenalectomía , Animales , Perros , Epinefrina/farmacología , Femenino , Hidrocortisona/farmacología , Hipoglucemia/inducido químicamente , Insulina , Hígado/metabolismo , Masculino , Somatostatina , Sistema Nervioso Simpático/metabolismo
3.
J Process Control ; 76: 62-73, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31178632

RESUMEN

Current artificial pancreas systems (AP) operate via subcutaneous (SC) glucose sensing and SC insulin delivery. Due to slow diffusion and transport dynamics across the interstitial space, even the most sophisticated control algorithms in on-body AP systems cannot react fast enough to maintain tight glycemic control under the effect of exogenous glucose disturbances caused by ingesting meals or performing physical activity. Recent efforts made towards the development of an implantable AP have explored the utility of insulin infusion in the intraperitoneal (IP) space: a region within the abdominal cavity where the insulin-glucose kinetics are observed to be much more rapid than the SC space. In this paper, a series of canine experiments are used to determine the dynamic association between IP insulin boluses and plasma glucose levels. Data from these experiments are employed to construct a new mathematical model and to formulate a closed-loop control strategy to be deployed on an implantable AP. The potential of the proposed controller is demonstrated via in-silico experiments on an FDA-accepted benchmark cohort: the proposed design significantly outperforms a previous controller designed using artificial data (time in clinically acceptable glucose range: 97.3±1.5% vs. 90.1±5.6%). Furthermore, the robustness of the proposed closed-loop system to delays and noise in the measurement signal (for example, when glucose is sensed subcutaneously) and deleterious glycemic changes (such as sudden glucose decline due to physical activity) is investigated. The proposed model based on experimental canine data leads to the generation of more effective control algorithms and is a promising step towards fully automated and implantable artificial pancreas systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA