Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Pediatr ; 261: 113585, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37354991

RESUMEN

We evaluated the association between left cardiac 3-dimensional echocardiographic parameters and brain injury in a single-center prospective study of neonates with neonatal encephalopathy. On day 2 of life, neonates with brain injury had greater left ventricle end-diastolic and stroke volume but also greater peak global circumferential strain detected by 3-dimensional echocardiogram.


Asunto(s)
Lesiones Encefálicas , Ecocardiografía Tridimensional , Disfunción Ventricular Izquierda , Recién Nacido , Humanos , Lactante , Función Ventricular Izquierda , Estudios Prospectivos , Ecocardiografía/métodos , Ecocardiografía Tridimensional/métodos , Volumen Sistólico , Ventrículos Cardíacos/diagnóstico por imagen , Lesiones Encefálicas/complicaciones , Lesiones Encefálicas/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen
2.
J Pediatr ; 257: 113369, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36868306

RESUMEN

OBJECTIVES: To compare trends in the anterior cerebral artery (ACA) Doppler markers of vascular flow for neonates with a congenital heart defect (CHD) with and without diastolic systemic steal during the first 7 days of life. METHODS: Prospective study recruiting newborns (≥35 weeks of gestation) with a CHD. Doppler ultrasound and echocardiography were performed daily from day 1 to 7. The cohort was divided into the presence/absence of holo-diastolic retrograde flow in the postductal aorta ("retrograde") on the last-available echocardiogram. Data extractors were masked to retrograde status. Mixed effect models (random slope/intercept) were constructed using RStudio. RESULTS: We enrolled 38 neonates with CHD. Retrograde aortic flow was present on the last echocardiogram in 23 (61%). Peak systolic velocity and mean velocity increased significantly over time, independent of retrograde status. However, having a "retrograde" flow status conferred a significant decrease over time of their ACA-end-diastolic velocity (ß = -5.75 cm/s, 95% CI -8.38 to -3.12, P < .001, when compared with the nonretrograde group), and a significant increase in the ACA resistive (ß = 0.16, 95% CI 0.10-0.22, P < .001) and pulsatility (ß = 0.49, 95% CI 0.28-0.69, P < .001) indexes. No subject presented retrograde diastolic flow in the ACA. CONCLUSIONS: In neonates with CHD in the first week of life, infants with echocardiographic signs of systemic diastolic steal within the pulmonary circulation have Doppler signs of cerebrovascular steal in the ACA.


Asunto(s)
Circulación Cerebrovascular , Cardiopatías Congénitas , Lactante , Recién Nacido , Humanos , Estudios Prospectivos , Velocidad del Flujo Sanguíneo , Cardiopatías Congénitas/diagnóstico por imagen , Ultrasonografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA