Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485244

RESUMEN

BACKGROUND: Postacute Covid-19 patients commonly present with respiratory symptoms; however, a noninvasive imaging method for quantitative characterization of respiratory patterns is lacking. PURPOSE: To evaluate if quantitative characterization of respiratory pattern on free-breathing higher temporal resolution MRI stratifies patients by cardiopulmonary symptom burden. STUDY TYPE: Prospective analysis of retrospectively acquired data. SUBJECTS: A total of 37 postacute Covid-19 patients (25 male; median [interquartile range (IQR)] age: 58 [42-64] years; median [IQR] days from acute infection: 335 [186-449]). FIELD STRENGTH/SEQUENCE: 0.55 T/two-dimensional coronal true fast imaging with steady-state free precession (trueFISP) at higher temporal resolution. ASSESSMENT: Patients were stratified into three groups based on presence of no (N = 11), 1 (N = 14), or ≥2 (N = 14) cardiopulmonary symptoms, assessed using a standardized symptom inventory within 1 month of MRI. An automated lung postprocessing workflow segmented each lung in each trueFISP image (temporal resolution 0.2 seconds) and respiratory curves were generated. Quantitative parameters were derived including tidal lung area, rates of inspiration and expiration, lung area coefficient of variability (CV), and respiratory incoherence (departure from sinusoidal pattern) were. Pulmonary function tests were recorded if within 1 month of MRI. Qualitative assessment of respiratory pattern and lung opacity was performed by three independent readers with 6, 9, and 23 years of experience. STATISTICAL TESTS: Analysis of variance to assess differences in demographic, clinical, and quantitative MRI parameters among groups; univariable analysis and multinomial logistic regression modeling to determine features predictive of patient symptom status; Akaike information criterion to compare the quality of regression models; Cohen and Fleiss kappa (κ) to quantify inter-reader reliability. Two-sided 5% significance level was used. RESULTS: Tidal area and lung area CV were significantly higher in patients with two or more symptoms than in those with one or no symptoms (area: 15.4 cm2 vs. 12.9 cm2 vs. 12.8 cm2 ; CV: 0.072, 0.067, and 0.058). Respiratory incoherence was significantly higher in patients with two or more symptoms than in those with one or no symptoms (0.05 vs. 0.043 vs. 0.033). There were no significant differences in patient age (P = 0.19), sex (P = 0.88), lung opacity severity (P = 0.48), or pulmonary function tests (P = 0.35-0.97) among groups. Qualitative reader assessment did not distinguish between groups and showed slight inter-reader agreement (κ = 0.05-0.11). DATA CONCLUSION: Quantitative respiratory pattern measures derived from dynamic higher-temporal resolution MRI have potential to stratify patients by symptom burden in a postacute Covid-19 cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
J Thorac Imaging ; 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37732714

RESUMEN

PURPOSE: The purpose of this study was to identify differences in imaging features between patients with confirmed right middle lobe (RML) torsion compared to those suspected yet without torsion. MATERIALS AND METHODS: This retrospective study entailing a search of radiology reports from April 1, 2014, to April 15, 2021, resulted in 52 patients with suspected yet without lobar torsion and 4 with confirmed torsion, supplemented by 2 additional cases before the search period for a total of 6 confirmed cases. Four thoracic radiologists (1 an adjudicator) evaluated chest radiographs and computed tomography (CT) examinations, and Fisher exact and Mann-Whitney tests were used to identify any significant differences in imaging features (P<0.05). RESULTS: A reversed halo sign was more frequent for all readers (P=0.001) in confirmed RML torsion than patients without torsion (83.3% vs. 0% for 3 readers, one the adjudicator). The CT coronal bronchial angle between RML bronchus and bronchus intermedius was larger (P=0.035) in torsion (121.28 degrees) than nontorsion cases (98.26 degrees). Patients with torsion had a higher percentage of ground-glass opacity in the affected lobe (P=0.031). A convex fissure towards the adjacent lobe on CT (P=0.009) and increased lobe volume on CT (P=0.001) occurred more often in confirmed torsion. CONCLUSION: A reversed halo sign, larger CT coronal bronchial angle, greater proportion of ground-glass opacity, fissural convexity, and larger lobe volume on CT may aid in early recognition of the rare yet highly significant diagnosis of lobar torsion.

3.
J Am Coll Radiol ; 20(12): 1215-1224, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37473854

RESUMEN

PURPOSE: The aim of this study was to evaluate the association between census tract-level measures of social vulnerability and residential segregation and incidental pulmonary nodule (IPN) follow-up. METHODS: This retrospective cohort study included patients with IPNs ≥6 mm in size or multiple subsolid or ground-glass IPNs <6 mm (with nonoptional follow-up recommendations) diagnosed between January 1, 2018, and December 30, 2019, at a large urban tertiary center and followed for ≥2 years. Geographic sociodemographic context was characterized by the 2018 Centers for Disease Control and Prevention Social Vulnerability Index (SVI) and the index of concentration at the extremes (ICE), categorized in quartiles. Multivariable binomial regression models were used, with a primary outcome of inappropriate IPN follow-up (late or no follow-up). Models were also stratified by nodule risk. RESULTS: The study consisted of 2,492 patients (mean age, 65.6 ± 12.6 years; 1,361 women). Top-quartile SVI patients were more likely to have inappropriate follow-up (risk ratio [RR], 1.24; 95% confidence interval [CI], 1.12-1.36) compared with the bottom quartile; risk was also elevated in top-quartile SVI subcategories of socioeconomic status (RR, 1.23; 95% CI, 1.13-1.34), Minority status and language (RR, 1.24; 95% CI, 1.03-1.48), housing and transportation (RR, 1.13; 95% CI, 1.02-1.26), and ICE (RR, 1.20; 95% CI, 1.11-1.30). Furthermore, top-quartile ICE was associated with greater risk for inappropriate follow-up among high-risk versus lower risk IPNs (RR, 1.33 [95% CI, 1.18-1.50] versus 1.13 [95% CI, 1.02-1.25]), respectively; P for interaction = .017). CONCLUSIONS: Local social vulnerability and residential segregation are associated with inappropriate IPN follow-up and may inform policy or interventions tailored for neighborhoods.


Asunto(s)
Nódulos Pulmonares Múltiples , Disparidades Socioeconómicas en Salud , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Estudios de Seguimiento , Clase Social
4.
J Am Coll Radiol ; 20(5S): S224-S233, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37236745

RESUMEN

Routine chest imaging has been used to identify unknown or subclinical cardiothoracic abnormalities in the absence of symptoms. Various imaging modalities have been suggested for routine chest imaging. We review the evidence for or against the use of routine chest imaging in different clinical scenarios. This document aims to determine guidelines for the use of routine chest imaging as initial imaging for hospital admission, initial imaging prior to noncardiothoracic surgery, and surveillance imaging for chronic cardiopulmonary disease. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Diagnóstico por Imagen , Sociedades Médicas , Humanos , Estados Unidos , Diagnóstico por Imagen/métodos
5.
Acad Radiol ; 30(10): 2269-2279, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37210268

RESUMEN

RATIONALE AND OBJECTIVES: Finding comparison to relevant prior studies is a requisite component of the radiology workflow. The purpose of this study was to evaluate the impact of a deep learning tool simplifying this time-consuming task by automatically identifying and displaying the finding in relevant prior studies. MATERIALS AND METHODS: The algorithm pipeline used in this retrospective study, TimeLens (TL), is based on natural language processing and descriptor-based image-matching algorithms. The dataset used for testing comprised 3872 series of 246 radiology examinations from 75 patients (189 CTs, 95 MRIs). To ensure a comprehensive testing, five finding types frequently encountered in radiology practice were included: aortic aneurysm, intracranial aneurysm, kidney lesion, meningioma, and pulmonary nodule. After a standardized training session, nine radiologists from three university hospitals performed two reading sessions on a cloud-based evaluation platform resembling a standard RIS/PACS. The task was to measure the diameter of the finding-of-interest on two or more exams (a most recent and at least one prior exam): first without use of TL, and a second session at an interval of at least 21 days with the use of TL. All user actions were logged for each round, including time needed to measure the finding at all timepoints, number of mouse clicks, and mouse distance traveled. The effect of TL was evaluated in total, per finding type, per reader, per experience (resident vs. board-certified radiologist), and per modality. Mouse movement patterns were analyzed with heatmaps. To assess the effect of habituation to the cases, a third round of readings was performed without TL. RESULTS: Across scenarios, TL reduced the average time needed to assess a finding at all timepoints by 40.1% (107 vs. 65 seconds; p < 0.001). Largest accelerations were demonstrated for assessment of pulmonary nodules (-47.0%; p < 0.001). Less mouse clicks (-17.2%) were needed for finding evaluation with TL, and mouse distance traveled was reduced by 38.0%. Time needed to assess the findings increased from round 2 to round 3 (+27.6%; p < 0.001). Readers were able to measure a given finding in 94.4% of cases on the series initially proposed by TL as most relevant series for comparison. The heatmaps showed consistently simplified mouse movement patterns with TL. CONCLUSION: A deep learning tool significantly reduced both the amount of user interactions with the radiology image viewer and the time needed to assess findings of interest on cross-sectional imaging with relevant prior exams.


Asunto(s)
Aprendizaje Profundo , Humanos , Estudios Retrospectivos , Radiólogos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos
6.
J Comput Assist Tomogr ; 47(2): 212-219, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36790870

RESUMEN

PURPOSE: To assess deep learning denoised (DLD) computed tomography (CT) chest images at various low doses by both quantitative and qualitative perceptual image analysis. METHODS: Simulated noise was inserted into sinogram data from 32 chest CTs acquired at 100 mAs, generating anatomically registered images at 40, 20, 10, and 5 mAs. A DLD model was developed, with 23 scans selected for training, 5 for validation, and 4 for test.Quantitative analysis of perceptual image quality was assessed with Structural SIMilarity Index (SSIM) and Fréchet Inception Distance (FID). Four thoracic radiologists graded overall diagnostic image quality, image artifact, visibility of small structures, and lesion conspicuity. Noise-simulated and denoised image series were evaluated in comparison with one another, and in comparison with standard 100 mAs acquisition at the 4 mAs levels. Statistical tests were conducted at the 2-sided 5% significance level, with multiple comparison correction. RESULTS: At the same mAs levels, SSIM and FID between noise-simulated and reconstructed DLD images indicated that images were closer to a perfect match with increasing mAs (closer to 1 for SSIM, and 0 for FID).In comparing noise-simulated and DLD images to standard-dose 100-mAs images, DLD improved SSIM and FID. Deep learning denoising improved SSIM of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in SSIM from 0.91 to 0.94, 0.87 to 0.93, 0.67 to 0.87, and 0.54 to 0.84, respectively. Deep learning denoising improved FID of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in FID from 20 to 13, 46 to 21, 104 to 41, and 148 to 69, respectively.Qualitative image analysis showed no significant difference in lesion conspicuity between DLD images at any mAs in comparison with 100-mAs images. Deep learning denoising images at 10 and 5 mAs were rated lower for overall diagnostic image quality ( P < 0.001), and at 5 mAs lower for overall image artifact and visibility of small structures ( P = 0.002), in comparison with 100 mAs. CONCLUSIONS: Deep learning denoising resulted in quantitative improvements in image quality. Qualitative assessment demonstrated DLD images at or less than 10 mAs to be rated inferior to standard-dose images.


Asunto(s)
Aprendizaje Profundo , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Relación Señal-Ruido
8.
J Comput Assist Tomogr ; 47(1): 50-57, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36571247

RESUMEN

OBJECTIVE: This study aimed to determine the prevalence of axillary and subpectoral (SP) lymph nodes after ipsilateral COVID-19 vaccine administration on chest computed tomography (CT). METHODS: Subjects with chest CTs between 2 and 25 days after a first or second vaccine dose, December 15, 2020, to February 12, 2021, were included. Orthogonal measures of the largest axillary and SP nodes were recorded by 2 readers blinded to vaccine administration and clinical details. A mean nodal diameter discrepancy of ≥6 mm between contralateral stations was considered positive for asymmetry. Correlation with the side of vaccination, using a Spearman rank correlation, was performed on the full cohort and after excluding patients with diseases associated with adenopathy. RESULTS: Of the 138 subjects (81 women, 57 men; mean [SD] age, 74.4 ± 11.7 years), 48 (35%) had asymmetrically enlarged axillary and/or SP lymph nodes, 42 (30%) had ipsilateral, and 6 (4%) had contralateral to vaccination ( P = 0.003). Exclusion of 29 subjects with conditions associated with adenopathy showed almost identical correlation, with asymmetric nodes in 32 of 109 (29%) ipsilateral and in 5 of 109 (5%) contralateral to vaccination ( P = 0.002). CONCLUSIONS: Axillary and/or SP lymph nodes ipsilateral to vaccine administration represents a clinical conundrum. Asymmetric nodes were detected at CT in 30% of subjects overall and 29% of subjects without conditions associated with adenopathy, approximately double the prevalence rate reported to the Centers for Disease Control and Prevention by vaccine manufacturers. When interpreting examinations correlation with vaccine administration timing and site is important for pragmatic management.


Asunto(s)
COVID-19 , Linfadenopatía , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , SARS-CoV-2 , Vacunas contra la COVID-19 , Prevalencia , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/patología , Tomografía Computarizada por Rayos X , Linfadenopatía/diagnóstico por imagen , Linfadenopatía/epidemiología , Linfadenopatía/patología , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Vacunación
10.
Eur J Radiol ; 156: 110515, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36099832

RESUMEN

PURPOSE: To evaluate detection and characterization of groundglass and fibrosis-like opacities imaged by non-contrast 0.55 Tesla MRI, and versus clinically-acquired chest CT images, in a cohort of post-Covid patients. MATERIALS AND METHODS: 64 individuals (26 women, mean age 53 ± 14 years, range 19-85) with history of Covid-19 pneumonia were recruited through a survivorship registry, with 106 non-contrast low-field 0.55 T cardiopulmonary MRI exams acquired from 9/8/2020-9/28/2021. MRI exams were obtained at an average interval of 9.5 ± 4.5 months from initial symptom report (range 1-18 months). Of these, 20 participants with 22 MRI exams had corresponding clinically-acquired CT chest imaging obtained within 30 days of MRI (average interval 18 ± 9 days, range 0-30). MR and CT images were reviewed and scored by two thoracic radiologists, for presence and extent of lung opacity by quadrant, opacity distribution, and presence versus absence of fibrosis-like subpleural reticulation and subpleural lines. Scoring was performed for each of four lung quadrants: right upper and middle lobe, right lower lobe, left upper lobe and lingula, and left lower lobe. Agreement between readers and modalities was assessed with simple and linear weighted Cohen's kappa (k) coefficients. RESULTS: Inter-reader concordance on CT for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 99%, 78%, 97%, 99%, and 94% (k 0.96, 0.86, 0.94, 0.97, 0.89), respectively. Inter-reader concordance on MR, among all 106 exams, for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 85%, 48%, 70%, 86%, and 76% (k 0.57, 0.32, 0.46, 0.47, 0.37), respectively. Inter-modality agreement between CT and MRI for opacity presence, opacity extent, opacity distribution, and presence subpleural lines and reticulation was 86%, 52%, 79%, 93%, and 76% (k 0.43, 0.63, 0.65, 0.80, 0.52). CONCLUSION: Low-field 0.55 T non-contrast MRI demonstrates fair to moderate inter-reader concordance, and moderate to substantial inter-modality agreement with CT, for detection and characterization of groundglass and fibrosis-like opacities.


Asunto(s)
COVID-19 , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen , Fibrosis
11.
Sci Rep ; 12(1): 11813, 2022 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-35821374

RESUMEN

Quantitative radiomic and iodine imaging features have been explored for diagnosis and characterization of tumors. In this work, we invistigate combined whole-lesion radiomic and iodine analysis for the differentiation of pulmonary tumors on contrast-enhanced dual-energy CT (DECT) chest images. 100 biopsy-proven solid lung lesions on contrast-enhanced DECT chest exams within 3 months of histopathologic sampling were identified. Lesions were volumetrically segmented using open-source software. Lesion segmentations and iodine density volumes were loaded into a radiomics prototype for quantitative analysis. Univariate analysis was performed to determine differences in volumetric iodine concentration (mean, median, maximum, minimum, 10th percentile, 90th percentile) and first and higher order radiomic features (n = 1212) between pulmonary tumors. Analyses were performed using a 2-sample t test, and filtered for false discoveries using Benjamini-Hochberg method. 100 individuals (mean age 65 ± 13 years; 59 women) with 64 primary and 36 metastatic lung lesions were included. Only one iodine concentration parameter, absolute minimum iodine, significantly differed between primary and metastatic pulmonary tumors (FDR-adjusted p = 0.015, AUC 0.69). 310 (FDR-adjusted p = 0.0008 to p = 0.0491) radiomic features differed between primary and metastatic lung tumors. Of these, 21 features achieved AUC ≥ 0.75. In subset analyses of lesions imaged by non-CTPA protocol (n = 72), 191 features significantly differed between primary and metastatic tumors, 19 of which achieved AUC ≥ 0.75. In subset analysis of tumors without history of prior treatment (n = 59), 40 features significantly differed between primary and metastatic tumors, 11 of which achieved AUC ≥ 0.75. Volumetric radiomic analysis provides differentiating capability beyond iodine quantification. While a high number of radiomic features differentiated primary versus metastatic pulmonary tumors, fewer features demonstrated good individual discriminatory utility.


Asunto(s)
Yodo , Neoplasias Pulmonares , Anciano , Biopsia , Femenino , Humanos , Pulmón/patología , Neoplasias Pulmonares/patología , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos
12.
Semin Ultrasound CT MR ; 43(3): 230-245, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35688534

RESUMEN

Lung nodules are frequently encountered while interpreting chest CTs and are challenging to detect, characterize, and manage given they can represent both benign or malignant etiologies. An understanding of features associated with malignancy and causes of interpretive pitfalls is helpful to avoid misdiagnoses. This review addresses pertinent topics related to the etiologies for missed lung nodules on radiography and CT. Additionally, CT imaging technical pitfalls and challenges in addition to issues in the evaluation of nodule morphology, attenuation, and size will be discussed. Nodule management guidelines will be addressed as well as recent investigations that further our understanding of lung nodules.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Humanos , Neoplasias Pulmonares/patología , Radiografía , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X
13.
Clin Imaging ; 88: 24-32, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35569280

RESUMEN

Acute pulmonary embolism (PE) is a critical, potentially life-threatening finding on contrast-enhanced cross-sectional chest imaging. Timely and accurate diagnosis of thrombus acuity and extent directly influences patient management, and outcomes. Technical and interpretive pitfalls may present challenges to the radiologist, and by extension, pose nuance in the development and integration of artificial intelligence support tools. This review delineates imaging considerations for diagnosis of acute PE, and rationale, hurdles and applications of artificial intelligence for the PE task.


Asunto(s)
Inteligencia Artificial , Embolia Pulmonar , Enfermedad Aguda , Estudios Transversales , Diagnóstico por Imagen , Humanos , Embolia Pulmonar/diagnóstico por imagen
14.
Acad Radiol ; 29 Suppl 2: S98-S107, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33610452

RESUMEN

OBJECTIVE: To evaluate the inter-observer consistency for subsolid pulmonary nodule radiomic features. MATERIALS AND METHODS: Subsolid nodules were selected by reviewing radiology reports of CT examinations performed December 1, 2015 to April 1, 2016. Patients with CTs at two time points were included in this study. There were 55 patients with subsolid nodules, of whom 14 had two nodules. Of 69 subsolid nodules, 66 were persistent at the second time point, yielding 135 lesions for segmentation. Two thoracic radiologists and an imaging fellow segmented the lesions using a semi-automated volumetry algorithm (Syngo.via Vb20, Siemens). Coefficient of variation (CV) was used to assess consistency of 91 quantitative measures extracted from the subsolid nodule segmentations, including first and higher order texture features. The accuracy of segmentation was visually graded by an experienced thoracic radiologist. Influencing factors on radiomic feature consistency and segmentation accuracy were assessed using generalized estimating equation analyses and the Exact Mann-Whitney test. RESULTS: Mean patient age was 71 (38-93 years), with 39 women and 16 men. Mean nodule volume was 1.39mL, range .03-48.2mL, for 135 nodules. Several radiomic features showed high inter-reader consistency (CV<5%), including entropy, uniformity, sphericity, and spherical disproportion. Descriptors such as surface area and energy had low consistency across inter-reader segmentations (CV>10%). Nodule percent solid component and attenuation influenced inter-reader variability of some radiomic features. The presence of contrast did not significantly affect the consistency of subsolid nodule radiomic features. Near perfect segmentation, within 5% of actual nodule size, was achieved in 68% of segmentations, and very good segmentation, within 25% of actual nodule size, in 94%. Morphologic features including nodule margin and shape (each p <0.01), and presence of air bronchograms (p = 0.004), bubble lucencies (p = 0.02) and broad pleural contact (p < 0.01) significantly affected the probability of near perfect segmentation. Stroke angle (p = 0.001) and length (p < 0.001) also significantly influenced probability of near perfect segmentation. CONCLUSIONS: The inter-observer consistency of radiomic features for subsolid pulmonary nodules varies, with high consistency for several features, including sphericity, spherical disproportion, and first and higher order entropy, and normalized non-uniformity. Nodule morphology influences the consistency of subsolid nodule radiomic features, and the accuracy of subsolid nodule segmentation.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Radiólogos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/patología , Tomografía Computarizada por Rayos X/métodos
15.
J Am Coll Radiol ; 19(3): 407-414, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34896068

RESUMEN

OBJECTIVE: To evaluate the impact of structured recommendations on follow-up completion for incidental lung nodules (ILNs). METHODS: Patients with ILNs before and after implementation of structured Fleischner recommendations and electronic tracking were sampled randomly. The cohorts were compared for imaging follow-up. Multivariable logistic regression was used to assess appropriate follow-up and loss to follow-up, with independent variables including use of structured recommendations or tracking, age, sex, race, ethnicity, setting of the index test (inpatient, outpatient, emergency department), smoking history, and nodule features. RESULTS: In all, 1,301 patients met final inclusion criteria, including 255 patients before and 1,046 patients after structured recommendations or tracking. Baseline differences were found in the pre- and postintervention groups, with smaller ILNs and younger age after implementing structured recommendations. Comparing pre- versus postintervention outcomes, 40.0% (100 of 250) versus 29.5% (309 of 1,046) of patients had no follow-up despite Fleischner indications for imaging (P = .002), and among the remaining patients, 56.6% (82 of 145) versus 75.0% (553 of 737) followed up on time (P < .001). Delayed follow-up was more frequent before intervention. Differences postintervention were mostly accounted for by nodules ≤8 mm in the outpatient setting (P < .001). In multivariable analysis, younger age, White race, outpatient setting, and larger nodule size showed significant association with appropriate follow-up completion (P < .015), but structured recommendations did not. Similar results applied for loss to follow-up. DISCUSSION: Consistent use of structured reporting is likely key to mitigate selection bias when benchmarking rates of appropriate follow-up of ILN. Emergency department patients and inpatients are at high risk of missed or delayed follow-up despite structured recommendations.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Electrónica , Humanos , Hallazgos Incidentales , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen
16.
J Am Coll Radiol ; 18(11S): S320-S329, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34794591

RESUMEN

Diffuse lung disease, frequently referred to as interstitial lung disease, encompasses numerous disorders affecting the lung parenchyma. The potential etiologies of diffuse lung disease are broad with several hundred established clinical syndromes and pathologies currently identified. Imaging plays a critical role in diagnosis and follow-up of many of these diseases, although multidisciplinary discussion is the current standard for diagnosis of several DLDs. This document aims to establish guidelines for evaluation of diffuse lung diseases for 1) initial imaging of suspected diffuse lung disease, 2) initial imaging of suspected acute exacerbation or acute deterioration in cases of confirmed diffuse lung disease, and 3) clinically indicated routine follow-up of confirmed diffuse lung disease without acute deterioration. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Asunto(s)
Enfermedades Pulmonares , Sociedades Médicas , Diagnóstico por Imagen , Medicina Basada en la Evidencia , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Estados Unidos
17.
J Am Coll Radiol ; 18(11S): S394-S405, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34794596

RESUMEN

Chest pain is a common reason that patients may present for evaluation in both ambulatory and emergency department settings, and is often of musculoskeletal origin in the former. Chest wall syndrome collectively describes the various entities that can contribute to chest wall pain of musculoskeletal origin and may affect any chest wall structure. Various imaging modalities may be employed for the diagnosis of nontraumatic chest wall conditions, each with variable utility depending on the clinical scenario. We review the evidence for or against use of various imaging modalities for the diagnosis of nontraumatic chest wall pain. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Asunto(s)
Pared Torácica , Dolor en el Pecho/diagnóstico por imagen , Diagnóstico por Imagen , Medicina Basada en la Evidencia , Humanos , Sociedades Médicas , Pared Torácica/diagnóstico por imagen , Estados Unidos
18.
J Comput Assist Tomogr ; 45(5): 765-775, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34347714

RESUMEN

ABSTRACT: Percutaneous computed tomography-guided transthoracic lung biopsy is an effective and minimally invasive procedure to achieve tissue diagnosis. Radiologists are key in appropriate referral for further workup, with percutaneous computed tomography-guided transthoracic lung biopsy performed by both thoracic and general interventionalists. Percutaneous computed tomography-guided transthoracic lung biopsy is increasingly performed for both diagnostic and research purposes, including molecular analysis. Multiple patient, lesion, and technique-related variables influence diagnostic accuracy and complication rates. A comprehensive understanding of these factors aids in procedure planning and may serve to maximize diagnostic yield while minimizing complications, even in the most challenging scenarios.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja , Humanos , Biopsia Guiada por Imagen , Pulmón/diagnóstico por imagen , Pulmón/patología , Reproducibilidad de los Resultados , Riesgo
19.
J Chem Phys ; 154(17): 174104, 2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-34241048

RESUMEN

We show that the centroid molecular dynamics (CMD) method provides a realistic way to calculate the thermal diffusivity a = λ/ρcV of a quantum mechanical liquid such as para-hydrogen. Once a has been calculated, the thermal conductivity can be obtained from λ = ρcVa, where ρ is the density of the liquid and cV is the constant-volume heat capacity. The use of this formula requires an accurate quantum mechanical heat capacity cV, which can be obtained from a path integral molecular dynamics simulation. The thermal diffusivity can be calculated either from the decay of the equilibrium density fluctuations in the liquid or by using the Green-Kubo relation to calculate the CMD approximation to λ and then dividing this by the corresponding approximation to ρcV. We show that both approaches give the same results for liquid para-hydrogen and that these results are in good agreement with the experimental measurements of the thermal conductivity over a wide temperature range. In particular, they correctly predict a decrease in the thermal conductivity at low temperatures-an effect that stems from the decrease in the quantum mechanical heat capacity and has eluded previous para-hydrogen simulations. We also show that the method gives equally good agreement with the experimental measurements for the thermal conductivity of normal liquid helium.

20.
Radiographics ; 41(4): 1043-1063, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34197245

RESUMEN

Lung transplant is increasingly performed for the treatment of end-stage lung disease. As the number of lung transplants and transplant centers continues to rise, radiologists will more frequently participate in the care of patients undergoing lung transplant, both before and after transplant. Potential donors and recipients undergo chest radiography and CT as part of their pretransplant assessment to evaluate for contraindications to transplant and to aid in surgical planning. After transplant, recipients undergo imaging during the postoperative hospitalization and also in the long-term outpatient setting. Radiologists encounter a wide variety of conditions leading to end-stage lung disease and a myriad of posttransplant complications, some of which are unique to lung transplantation. Familiarity with these pathologic conditions, including their imaging findings and their temporal relationship to the transplant, is crucial to accurate radiologic interpretation. Knowledge of the surgical techniques and expected postoperative appearance prevents confusing normal posttransplant imaging findings with complications. A basic understanding of the indications, contraindications, and surgical considerations of lung transplant aids in imaging interpretation and protocoling and also facilitates communication between radiologists and transplant physicians. Despite medical and surgical advances over the past several decades, lung transplant recipients currently have an average posttransplant life expectancy of only 6.7 years. As members of the transplant team, radiologists can help maximize patient survival and hopefully increase posttransplant life expectancy and quality of life in the coming decades. ©RSNA, 2021 An invited commentary by Bierhals is available online. Online supplemental material is available for this article.


Asunto(s)
Trasplante de Pulmón , Calidad de Vida , Diagnóstico por Imagen , Humanos , Trasplante de Pulmón/efectos adversos , Selección de Paciente , Complicaciones Posoperatorias/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...