1.
IEEE Trans Biomed Eng ; 66(10): 2848-2854, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30716028

RESUMEN

OBJECTIVE: To develop a novel radio-frequency (RF) concept for ultra-high field (UHF) human magnetic resonance imaging (MRI) based on a coaxial resonant cavity. METHODS: A two-channel slotted coaxial cavity RF applicator was designed for human head MRI at 9.4T. Physical dimensions made the proposed conducting structure resonant at the required frequency without tuning lumped elements. Numerical electromagnetic modeling was used to optimize the design. RF safety was assessed with two representative human body models. MR experiments on a 9.4T scanner included gradient echo images and mapping of a circularly polarized RF magnetic field in the human head phantom. RESULTS: The simulations and the phantom MR experiments agreed both qualitatively and quantitatively. The design was relatively simple, robust and required only a few additional reactive elements for the applicator's input impedance matching. The transmit efficiency and homogeneity of the excitation field were only 20% and 4% lower compared to a conventional 8-channel head array. CONCLUSION: The coaxial RF applicator was feasible for human MRI at UHF and required no lumped elements for its tuning. Imaging performance of the RF applicator was only moderately lower compared to the conventional transmit array, but would be sufficient to provide an anatomical reference for the heteronuclei MRI. SIGNIFICANCE: An alternative approach with the minimal involvement of lumped elements becomes feasible to design volume-type RF coils for UHF human MRI.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Seguridad de Equipos , Cabeza , Humanos , Fantasmas de Imagen , Ondas de Radio
2.
J Magn Reson ; 2010 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-20580891

RESUMEN

Parallel excitation holds strong promises to mitigate the impact of large transmit B(1) (B(1)(+)) distortion at very high magnetic field. Accelerated RF pulses, however, inherently tend to require larger values in RF peak power which may result in substantial increase in Specific Absorption Rate (SAR) in tissues, which is a constant concern for patient safety at very high field. In this study, we demonstrate adapted rate RF pulse design allowing for SAR reduction while preserving excitation target accuracy. Compared with other proposed implementations of adapted rate RF pulses, our approach is compatible with any k-space trajectories, does not require an analytical expression of the gradient waveform and can be used for large flip angle excitation. We demonstrate our method with numerical simulations based on electromagnetic modeling and we include an experimental verification of transmit pattern accuracy on an 8 transmit channel 9.4T system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...