Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Placenta ; 148: 53-58, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38401206

RESUMEN

INTRODUCTION: The objective was to confirm and semiquantify the maternal perfusion of the intervillous space between 8 and 13 + 6 gestational weeks (GW). METHODS: We conducted a prospective, multicenter, and nonrandomized open study. Women undergoing voluntary termination of pregnancy at three different gestational ages (Group 8 GW: 8 to 8 + 6 GW, Group 11GW: 11 to 11 + 6 GW and Group 13GW: 13 to 13 + 6 GW) were included, with 14 subjects per group. Women presenting with a personal risk of preeclampsia and/or intrauterine growth restriction were excluded. Contrast-enhanced ultrasound (CEUS) was performed with an intravenous bolus administration of 2.4 mL of microbubbles. The region of interest (ROI) was the entire placenta. The perfusion curves and kinetic parameters, including wash-in perfusion index, peak enhancement and mean transit time, were calculated. RESULTS: Of the 42 women initially included, interpretable perfusion curves could be obtained for 33. Regardless of the gestational age, contrast was observed in the entire placenta. No significant difference in perfusion parameters was observed between groups. There was an association between signal intensity and both maternal heart frequency and placental location. Signal intensity was decreased when the heart frequency increased (p < 0.05) and when the placenta was in a nonanterior position (p > 0.005). DISCUSSION: We confirmed the presence of maternal perfusion of the intervillous space as early as 8 GW. No significant increase in perfusion parameters was observed between 8 and 13 + 6 GW. Our observations, in accordance with the previous experiment published by Roberts et al.1, strongly challenge the classic trophoblastic plug theory.


Asunto(s)
Placenta , Femenino , Embarazo , Humanos , Placenta/diagnóstico por imagen , Primer Trimestre del Embarazo , Estudios Prospectivos , Ultrasonografía , Perfusión
2.
J Mech Behav Biomed Mater ; 147: 106139, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37757616

RESUMEN

Fasciae are soft tissues permitting a large but finite sliding between organs, but also between skin and its underlying elements. The contribution of fasciae has been seldomly reported in the literature, and is usually neglected or overly simplified within simulations. In the present contribution, we propose to use peeling tests in order to quantify the skin-to-bone interaction associated with a simple computational approach based on a geometrical modeling of the skin-to-bone interface. To this aim, a new experimental set up combined with a computational model to characterize the skin-to-bone interaction were proposed. The current work is devoted to the porcine scalp complex since it constitutes a common mechanical surrogate for the human scalp complex. The ad hoc computational approach and peeling set up were firstly evaluated on a validation material, before being used to characterize the skin-to-bone interaction within 6 porcine specimens harvested from the scalp. Our experimental setup allowed to measure the peeling response of porcine scalp, showing a three-regimes response including a plateau force. The computational approach satisfyingly reproduced the peeling response based uniquely on experimental-based parameters and on a discrete modeling of skin-to-bone interface. The presented methodology is a first attempt to propose a computationally efficient geometrically based model able to take into account the skin-to-bone interaction up to failure and corroborated by experimental data, and may be largely extended to the modeling of soft interactions between biological human tissues in the future.

3.
Clin Biomech (Bristol, Avon) ; 109: 106093, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37734119

RESUMEN

BACKGROUND: The vacuum assisted delivery represents, in France, the most used operative vaginal delivery technique. The purpose was to provide a preliminar quantification of the operator's hand kinematics while performing a vacuum assisted delivery. METHODS: A group of 21 participants composed of 12 trainees and 9 obstetricians were recorded performing a vacuum assisted delivery on a training dummy, the matching fetal presentation was a left occiput anterior position. FINDINGS: The mean movement was composed of a first phase corresponding to a descendant pull, followed by an ascendant finish of the gesture. No significative difference were found between the trainees and the obstetricians' mean gesture. INTERPRETATION: This is the first quantification of the clinical gesture associated with the vacuum assisted delivery.

4.
Bioinspir Biomim ; 17(6)2022 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-36206746

RESUMEN

The design of obstetrical suction cups used for vacuum assisted delivery has not substantially evolved through history despite of its inherent limitations. The associated challenges concern both the decrease of risk of soft tissue damage and failure of instrumental delivery due to detachment of the cup. The present study firstly details some of the suction-based strategies that have been developed in wildlife in order to create and maintain an adhesive contact with potentially rough and uneven substratum in dry or wet environments. Such strategies have permitted the emergence of bioinspired suction-based devices in the fields of robotics or biomedical patches that are briefly reviewed. The objective is then to extend the observations of such suction-based strategies toward the development of innovative medical suction cups. We firstly conclude that the overall design, shape and materials of the suction cups could be largely improved. We also highlight that the addition of a patterned surface combined with a viscous fluid at the interface between the suction cup and scalp could significantly limit the detachment rate and the differential pressure required to exert a traction force. In the future, the development of a computational model including a detailed description of scalp properties should allow to experiment various designs of bioinspired suction cups.


Asunto(s)
Animales Salvajes , Robótica , Animales , Succión , Viscosidad , Evolución Biológica
6.
Theriogenology ; 187: 135-140, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35569412

RESUMEN

OBJECTIVES: The main aim of the study was to quantitatively characterize placental perfusion using contrast-enhanced ultrasound in a longitudinal study performed in pregnant rabbits. As a secondary objective, we qualitatively assessed the placental perfusion. METHODS: Three pregnant rabbits were used. Contrast-enhanced ultrasound was performed twice for each dam, either on embryo development (ED) day 14, 21 or 28 of pregnancy, under general anesthesia. Both qualitative and quantitative analyses were performed based on ultrasound assessment. RESULTS: Altogether, data from 29 fetuses were analyzed: 10 at ED-14; 12 at ED-21, and 7 at ED-28. Placental vascularization was mainly peripheral at the earliest gestational age and became gradually homogeneous within the whole placenta as pregnancy progressed. Intensity parameters and relative blood flows significantly increased with gestational age. The wash-in and wash-out rates were correlated and a significant increase in wash-in compared to in wash-out rates was observed with increased gestational age. CONCLUSION: Contrast-enhanced ultrasound is feasible in animal models and allows qualitative and quantitative analysis of placental vascularization during pregnancy.


Asunto(s)
Placenta , Animales , Femenino , Edad Gestacional , Estudios Longitudinales , Perfusión/veterinaria , Placenta/diagnóstico por imagen , Embarazo , Conejos , Ultrasonografía/veterinaria
7.
Gynecol Obstet Fertil Senol ; 50(4): 314-321, 2022 04.
Artículo en Francés | MEDLINE | ID: mdl-34990881

RESUMEN

INTRODUCTION: A constitutional karyotype is often assayed for the couple before ICSI management. The objective of this study was to assess the prevalence of chromosomal abnormality in an infertile population, the impact on the care of couples and its cost. METHODS: A single-center retrospective study was carried out at the Fertility Center of the University Hospital of Nancy, including all infertile couples who underwent a karyotype analysis from June 2009 to December 2016. RESULTS: 1252 couples were included. 7.9% had at least one abnormal karyotype. A change in care affected 22% of these couples, i.e. 1.7% of the total population. 9% of couples with karyotype abnormality underwent PGD. In the male population, the percentage of abnormal spermograms is significantly higher in the group with karyotype abnormality compared to the control group (85.7% vs. 46.5%, P<0.001). DISCUSSION: The constitutional karyotype, due to its high economic and human cost, and limited interest, is a screening method for chromosomal abnormalities that has no place systematically before performing IVF. The future lies in the restriction of the indications for prescribing the karyotype as well as in the realization of PGS in targeted situations.


Asunto(s)
Infertilidad , Inyecciones de Esperma Intracitoplasmáticas , Aberraciones Cromosómicas , Hospitales , Humanos , Cariotipificación , Masculino , Estudios Retrospectivos
8.
Placenta ; 117: 5-12, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34768169

RESUMEN

Ultrasound imaging is a vital tool for exploring in vivo the placental function which is essential to understand pathological phenomena such as preeclampsia or intrauterine growth restriction. As technology advances including ready availability of three-dimensional (3D) probes and novel software, new markers of placental function become possible. The objective of this review was to provide an overview of the new ultrasound markers of placental function with a focus on the potential clinical application of three-dimensional power Doppler (3DPD). A broad-free text literature search was undertaken based on human placental studies and sixty full-text studies were included in this review. Three-dimensional power Doppler is a promising technique to predict preeclampsia in the first trimester. However, the influence of external factors such as body mass index, parameter standardisation and machine settings still need to be addressed. Contrast-enhanced ultrasound is currently reserved for research, because the required injected contrast mediums are not currently approved for use in pregnancy, although the safety data is reassuring.


Asunto(s)
Placenta/diagnóstico por imagen , Ultrasonografía Prenatal/tendencias , Femenino , Humanos , Imagenología Tridimensional , Preeclampsia/diagnóstico por imagen , Embarazo , Ultrasonografía Prenatal/métodos
9.
Gynecol Obstet Fertil Senol ; 50(5): 390-394, 2022 05.
Artículo en Francés | MEDLINE | ID: mdl-34800739

RESUMEN

OBJECTIVE: The prediction model M6 classifies pregnancy of unknown location (PUL) into a low-risk or a high-risk group in developing ectopic pregnancy (EP). The aim of this study was to validate the two-step M6 model's ability to classify PUL in French women. MATERIAL AND METHODS: All women with a diagnosis of PUL over a year were included in this single center retrospective study. Patients with a diagnosis of EP at the first consultation of with incomplete data were excluded. For each patient, the M6 model calculator was used to classified them into "high risk of EP" and "low risk of EP" group. The reference standard was the final diagnostic: failed PUL (FPUL), intrauterine pregnancy (IUP) of EP. The statistical measures of the test's performance were calculated. RESULTS: Over the period, 255 women's consulted for a PUL, 197 has been included in the study. Final diagnosis were: 94 FPUL (94/197; 47.7%), 74 IUP (74/197; 37.6%) et 29 EP (29/197; 14.7%). The first step of the M6 model classified 16 women in the FPUL group of which 15 (15/16; 93.7%) correctly. The second step of the M6 model classified 181 women: 90 (90/181; 49.7%) in the "high risk of EP" group of which 63 (63/90; 70%) were FPUL/IUP and 27 (27/90; 30%) were EP. 91 (91/181; 50.3%) was classified in the "low risk of EP" group of which 90 (90/91; 98.9%) were FPUL/IUP and 1 (1/91; 1.1%) were EP. EP were correctly classified with sensitivity of 96.4%, negative predictive value of 98.9%, specificity of 58.8% and positive predictive value of 30.0%. CONCLUSIONS: The prediction model of PUL M6 classified EP in "high risk of EP group" with a sensitivity of 96.4%. It classified 50.3% of PUL in a "low risk of EP" group with a negative predictive value of 98.9%.


Asunto(s)
Embarazo Ectópico , Femenino , Humanos , Valor Predictivo de las Pruebas , Embarazo , Embarazo Ectópico/diagnóstico , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
Ann Cardiol Angeiol (Paris) ; 70(5): 299-307, 2021 Nov.
Artículo en Francés | MEDLINE | ID: mdl-34635331

RESUMEN

PURPOSE: Coronary catheterization after transcatheter aortic valve implantation (TAVR) may be challenging. The main objective of the study is to assess the feasibility of coronary catheterization and angioplasty according to each type of valve. PATIENTS AND METHOD: We retrospectively studied coronary angiography or percutaneous angioplasty procedures after TAVR in two different centers. The catheterization success of coronary artery was evaluated according to the quality of engagement in ostium and opacification of the artery. Other indicators were collected including catheters used, fluoroscopy and angiography times, DAP and the volume of the contrast agent. RESULTS: Among 1512 TAVR procedures, 33 patients were included. The Sapien 3® valve was implanted in 22 patients and the Evolut® in 11 patients (7 Evolut-R® and 4 Evolut Pro®). Coronary angiography with selective or partially selective catheterization has been successfully performed in all patients with a Sapien 3® valve. In the Evolut® group we identified 3 cases of non-selective catheterization for the right coronary and 1 case for the left coronary. Standard Judkins catheters seem to be the most suitable for both types of valve with very good efficiency. CONCLUSION: The results of our study is promising for the future of TAVR with a coronary catheterization success rate close to 100% with some difficulties for the Evolut® supra-annular valves. Special attention should be paid to the technique of implantation and orientation of cups in the aortic sinus.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
11.
J Gynecol Obstet Hum Reprod ; 50(8): 102135, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33798748

RESUMEN

CONTEXT: Simulation-based education (SBE) has demonstrated its acceptability and effectiveness in improving ultrasound training. Because of the high cost of its implementation (investment in equipment and supervision), a pragmatic assessment of the transfer of skills learned in SBE to clinical practice and the identification of its optimal scheduling conditions have been requested to optimize its input. OBJECTIVES: To quantify the long-term impact of simulation-based education (SBE) on the adequate performance of ultrasound fetal biometry measurements (I). The secondary objective was to identify the temporal patterns that enhanced SBE input in learning (II). METHODS: Trainees were arbitrarily assigned to a 6-month course in obstetric ultrasound with or without an SBE workshop. In the SBE group, the workshop was implemented 'before' or at an 'early' or a 'late-stage' of the course. Those who did not receive SBE were the control group. The ultrasound skills of all trainees were prospectively collected, evaluated by calculating the delta between OSAUS (Objective Structured Assessment of Ultrasound Skills) scores before and after the course (I). Concomitantly, the accuracy of trainees' measurements was assessed throughout the course by verifying their correlation with the corresponding measurements by their supervisors. The percentage of trainees able to perform five consecutive sets of correct measurements in the control group and in each SBE subgroup were compared (II). RESULTS: The study included 61 trainees (39 SBE and 22 controls). Comparisons between groups showed no significant difference in the quantitative assessment of skill enhancement (difference in the pre- and post-internship OSAUS score: 1.09 ± 0.87 in the SBE group and 0.72 ± 0.98 in the control group) (I). Conversely, the predefined acceptable skill level was reached by a significantly higher proportion of trainees in the 'early' SBE subgroup (74%, compared with 30% in the control group, P<0.01)(II). CONCLUSIONS: The quantitative assessment does not support the existence of long-term benefits from SBE training, although the qualitative assessment confirmed SBE helped to raise the minimal level within a group when embedded in an 'early' stage of a practical course.


Asunto(s)
Biometría/métodos , Simulación por Computador/normas , Feto/diagnóstico por imagen , Aprendizaje , Ultrasonografía/métodos , Adulto , Biometría/instrumentación , Simulación por Computador/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Entrenamiento Simulado/métodos , Entrenamiento Simulado/normas , Entrenamiento Simulado/estadística & datos numéricos , Ultrasonografía/normas , Ultrasonografía/estadística & datos numéricos
12.
Gynecol Obstet Fertil Senol ; 49(9): 660-664, 2021 Sep.
Artículo en Francés | MEDLINE | ID: mdl-33636411

RESUMEN

OBJECTIVE: To compare the effectiveness and the safety of cervical ripening between two methods: the Cook double balloon catheter and the dinoprostone pessary (Propess 10mg). METHODS: We performed a retrospective comparative study in a French maternity. We analyzed 404 women with induction of labour after 37 gestational weeks, with singleton cephalic live fetus, unscarred uterus, unruptured membranes, and Bishop score<6. The primary endpoint was the time between the start of the ripening and the delivery. Secondary endpoints include effectiveness and safety outcomes of the methods. RESULTS: Compared to dinoprostone pessary, the balloon catheter was associated with a longer time to delivery (34.4±16.5 vs 25.5±15.3h; P<0.001). This difference is found in both primiparous and multiparous women. Balloon catheter is also associated with a smaller improvement of the Bishop score (2.5±2.1 vs 4.2±2.9 Bishop's points; P<0.001) and more failure to achieve delivery in 24h (32.3% vs 56.7%; P<0.001). There was no difference in mother and fetal safety. CONCLUSION: In this retrospective study, cervical ripening using balloon catheter seems to lengthen the induction of labour. No difference in safety outcomes with dinoprostone was found.


Asunto(s)
Maduración Cervical , Oxitócicos , Catéteres , Dinoprostona , Femenino , Humanos , Trabajo de Parto Inducido , Embarazo , Estudios Retrospectivos
13.
BJOG ; 128(10): 1646-1655, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33393174

RESUMEN

OBJECTIVE: To describe and compare the characteristics of women with placenta accreta spectrum (PAS) and their pregnancy outcomes according to the presence of placenta praevia and a prior caesarean section. DESIGN: Prospective population-based study. SETTING: All 176 maternity hospitals of eight French regions. POPULATION: Two hundred and forty-nine women with PAS, from a source population of 520 114 deliveries. METHODS: Women with PAS were classified into two risk-profile groups, with or without the high-risk combination of placenta praevia (or an anterior low-lying placenta) and at least one prior caesarean. These two groups were described and compared. MAIN OUTCOME MEASURES: Population-based incidence of PAS, characteristics of women, pregnancies, deliveries and pregnancy outcomes. RESULTS: The PAS population-based incidence was 4.8/10 000 (95% CI 4.2-5.4/10 000). After exclusion of women lost to follow up from the analysis, the group with placenta praevia and a prior caesarean included 115 (48%) women and the group without this combination included 127 (52%). In the group with both factors, PAS was more often suspected antenatally (77% versus 17%; P < 0.001) and more often percreta (38% versus 5%; P < 0.001). This group also had more hysterectomies (53% versus 21%, P < 0.001) and higher rates of blood product transfusions, maternal complications, preterm births and neonatal intensive care unit admissions. Sensitivity analysis showed similar results after exclusion of women who delivered vaginally. CONCLUSION: More than half the cases of PAS occurred in women without the combination of placenta praevia and a prior caesarean delivery, and these women had better maternal and neonatal outcomes. We cannot completely rule out that some of the women who delivered vaginally had placental retention rather than PAS; however, we found similar results among women who delivered by caesarean. TWEETABLE ABSTRACT: Half the women with PAS do not have both placenta praevia and a prior caesarean delivery, and they have better maternal outcomes.


Asunto(s)
Cesárea , Placenta Accreta/epidemiología , Placenta Previa , Adulto , Femenino , Francia/epidemiología , Humanos , Placenta Accreta/etiología , Embarazo , Resultado del Embarazo , Estudios Prospectivos
14.
Gynecol Obstet Fertil Senol ; 49(4): 275-281, 2021 04.
Artículo en Francés | MEDLINE | ID: mdl-33453459

RESUMEN

OBJECTIVES: To develop and validate a customized variant for fetal biometry of the generic OSAUS score (Objective Structured Assessment of Ultrasound Skills) METHODS: The 5-points OSAUS METHOD grid was elaborated by defining five target skills specific to fetal biometry for each thematic item of the generic score. The level of skills of 43 trainees was prospectively assessed during an ultrasound examination by using this grid. The results of the "novice" level group (experience<10 ultrasounds) were compared to those of the "intermediate" level group (experience≥10 ultrasounds) (I). The reached/non-reached skills ratio within the different items composing the score allowed the identification of priority areas of improvement (II). Previously published distribution and actual distribution of ratings according to the generic pass/fail score were compared (III). RESULTS: Median scores of "novices" (n=29) and "intermediates" (n=14) groups were statistically different, 1.87 (±0.75) and 3.31 (±0.83) (P=1.85-5), respectively and corresponded to the pre-existing experience (I). A lower ratio of reached skill allowed the identification of "documentation of the examination" item as a priority area of improvement for both groups (II). The relevance of the pass/fail score is consolidated, even if an overlap was observed between novices and intermediates groups (III). CONCLUSIONS: The relevancy and feasibility of using OSAUS scoring method for fetal biometry are supported. In addition, the possibility of comparisons with generic OSAUS remains.


Asunto(s)
Competencia Clínica , Proyectos de Investigación , Biometría , Femenino , Humanos , Embarazo , Ultrasonografía , Ultrasonografía Prenatal
17.
Gynecol Obstet Fertil Senol ; 48(11): 800-805, 2020 11.
Artículo en Francés | MEDLINE | ID: mdl-32461028

RESUMEN

BACKGROUND: Fetal biometry quality directly influences obstetrical care relevance. However, obstetrician proficiencies are heterogeneous in particular during initial training. OBJECTIVES: To assess the predictive value of OSAUS scale to identify operators with enough command to perform a valid estimation of fetal weight (EFW) (I). This study also assesses OSAUS intra-operator inter-exams variability (II) and pass/fail score relevancy (III). METHODS: Lecturers in Nancy University Hospital assessed trainees' proficiency for EWF systematically and prospectively through OSAUS scale. The trainee assessment was performed right after the one of the senior operator (reference EFW) on three consecutive patients during standard care ultrasounds. To ensure variability in proficiency within the sample, previous practice was taken into account during enrollment ("novices" and "intermediates" for<20 and 20 past exams, respectively). Correlation between mean OSAUS and validity of EFW (a valid EFW was defined by a difference with the reference EWF<0.8 Z-score) and variability between consecutive assessments were assessed. RESULTS: The study population was constituted of 8 "novice" and 8 "intermediate" trainees. Association between OSAUS and EFW validity was significant (P<0.03) (I). Intra-operator inter-exams variability was majored in the "novice" group (coefficients of variation were 25% vs. 10% in "novice" and "intermediate" group respectively) (II). Within the sample, specificity and positive predictive value of a pass/fail score OSAUS>3.5 to predict EFW validity were 77% and 71%, respectively (III). CONCLUSION: A 3.5 OSAUS pass/fail score could provide a relevant threshold to estimate operator proficiency in assessing fetal biometry in an autonomous and secure way.


Asunto(s)
Biometría , Ultrasonografía Prenatal , Femenino , Peso Fetal , Humanos , Embarazo , Estudios Prospectivos , Ultrasonografía
19.
Diagn Interv Imaging ; 101(7-8): 481-487, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32241702

RESUMEN

PURPOSE: To compare fetal ultrasound measurements performed by two observers with different levels of experience and evaluate the potential contribution of the use of three-dimensional (3D) ultrasound on repeatability, reproducibility and agreement of two-dimensional (2D) and 3D-derived measurements. MATERIALS AND METHODS: Two observers (one senior and one junior) measured head circumference (HC), abdominal circumference (AC) and femur length (FL) in 33 fetuses (20 to 40 weeks of gestation). Each observer performed two series of 2D measurements and two series of 3D measurements (i.e., measurements derived from triplane volume processing). Measurements were converted into Z-scores according to gestational age. Variability between the different series of measurements was studied using Bland-Altmann plots and intra-class correlation coefficients (ICC). RESULTS: Agreement with the 2D measurements of the senior observer was higher in 3D than in 2D for the junior observer (systematic differences of -0.4, -0.2 and -0.8 Z-score vs. -0.1, -0.1 and -0.6 for HC, AC and FL on 2D and 3D datasets, respectively). The use of 3D ultrasound improved junior observer repeatability (ICC=0.94, 0.88, 0.90 vs. 0.94, 0.94 and 0.96 for HC, AC and FL in 2D and 3D, respectively). The reproducibility was greater using the junior observer 3D datasets (ICC=0.75, 0.60 and 0.45 vs. 0.79, 0.89 and 0.63 for HC, AC and FL, respectively). CONCLUSION: The use of 3D ultrasound improves the consistency of the measurements performed by a junior observer and increases the overall repeatability and reproducibility of measurements performed by observers with different levels of experience.


Asunto(s)
Biometría , Feto , Femenino , Feto/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Variaciones Dependientes del Observador , Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía Prenatal
20.
Gynecol Obstet Fertil Senol ; 48(5): 428-435, 2020 05.
Artículo en Francés | MEDLINE | ID: mdl-32145451

RESUMEN

As a result of improvements in life expectancy and therapies, increasing numbers of patients with cystic fibrosis become pregnant. The first studies were pessimistic and report adverse outcomes on the fetus and the mother. In the recent publications, long-term outcome for women with cystic fibrosis does not appear to be negatively impacted by pregnancy. Furthermore, the number of women successfully completing pregnancy continues to rise. The aim of this review is to assess the outcome of pregnancy in women with cystic fibrosis and the impact of pregnancy on the disease. It is hoped it will improve the counseling for pregnant women with cystic fibrosis and their obstetrical management.


Asunto(s)
Fibrosis Quística , Complicaciones del Embarazo , Consejo , Fibrosis Quística/complicaciones , Fibrosis Quística/terapia , Femenino , Humanos , Embarazo , Complicaciones del Embarazo/terapia , Resultado del Embarazo , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...