Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
4.
J Invasive Cardiol ; 31(8): 212-216, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31088992

RESUMEN

BACKGROUND: Stroke recurrence despite optimal oral anticoagulation (OAC) might represent a novel indication for left atrial appendage occlusion (LAAO). The heterogeneity of these patients is generally high, as the presence of valvular atrial fibrillation (VAF) is common. The aim of this study was to explore the role of LAAO as an adjunctive therapy to OAC in patients with recurrent stroke despite optimal OAC. METHODS: The study screened consecutive patients who underwent percutaneous LAAO at nine centers between 2009 and 2017. Patients with recurrent stroke despite optimal OAC were selected and those with an absolute or relative contraindication to OAC were not included in the study. RESULTS: Among 837 patients who underwent LAAO between the study period, a total of 22 (2.6%) met the inclusion criteria. There was a high percentage of VAF (38%) and 59% presented more than one cardioembolic event before LAAO. All patients underwent successful implantation of the device and no procedural major adverse events were reported. In all but 3 patients, anticoagulation was continued after LAAO. With a median clinical follow-up of 1.8 years (range, 0.7-2.8 years), only 1 stroke and 1 transient ischemic attack were reported, translating into a significant reduction of cerebrovascular events before and after LAAO (2.0 ± 1.0 events vs 0.1 ± 0.3 events; P<.01). Imaging follow-up revealed only 1 case of device thrombosis. CONCLUSIONS: LAAO as an adjunctive therapy to OAC seems to be feasible and safe in patients with previous cardioembolic events despite optimal OAC. In our series, this strategy was associated with a low rate of cerebrovascular events after LAAO.


Asunto(s)
Anticoagulantes/administración & dosificación , Apéndice Atrial/cirugía , Fibrilación Atrial/terapia , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Fibrilación Atrial/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
8.
JACC Cardiovasc Interv ; 11(19): 1932-1941, 2018 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-30249439

RESUMEN

OBJECTIVES: This study sought to evaluate the feasibility, safety, and efficacy of the Ultraseal device for left atrial appendage closure (LAAC) (Cardia, Eagan, Minnesota) in patients with nonvalvular atrial fibrillation at high bleeding risk. BACKGROUND: The Ultraseal device is a novel bulb-and-sail designed LAAC device, with an articulating joint enabling conformability to heterogeneous angles and shapes of appendage anatomy. METHODS: This was a multicenter study including consecutive patients undergoing LAAC with the Ultraseal device at 15 Canadian and European sites. Periprocedural and follow-up events were systematically collected, and transesophageal echocardiography at 45 to 180 days post-procedure was routinely performed in all centers but 3. RESULTS: A total of 126 patients (mean age 75 ± 8 years; mean CHA2DS2-VASc score 5 ± 2; mean HAS-BLED score 4 ± 1) were included. The device was successfully implanted in 97% of patients. A major periprocedural adverse event occurred in 3 (2.4%) patients (clinically relevant pericardial effusion [n = 1], stroke [n = 1], device embolization [n = 1]). Ninety percent of patients were discharged on single or dual antiplatelet therapy. Follow-up transesophageal echocardiography was available in 89 (73%) patients, with no cases of large (>5 mm) residual leak and 5 (5.6%) cases of device-related thrombosis (all successfully treated with anticoagulation therapy). At a median follow-up of 6 (interquartile range: 3 to 10) months, the rates of stroke and transient ischemic attack were 0.8% and 0.8%, respectively, with no systemic emboli. None of the events occurred in patients with device-related thrombosis. CONCLUSIONS: In this initial multicenter experience, LAAC with the Ultraseal device was associated with a high implant success rate and a very low incidence of periprocedural complications. There were no late device-related clinical events and promising efficacy results were observed regarding thromboembolic prevention at midterm follow-up. Larger studies are further warranted to confirm the long-term safety and efficacy of this novel device.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Canadá , Cateterismo Cardíaco/efectos adversos , Diseño de Equipo , Europa (Continente) , Estudios de Factibilidad , Femenino , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
JACC Cardiovasc Interv ; 11(11): 1074-1083, 2018 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-29880102

RESUMEN

OBJECTIVES: The aims of this registry were to determine the incidence, predictors, and prognostic value of periprocedural acute kidney injury (AKI) after left atrial appendage closure (LAAC). BACKGROUND: No data exist on the occurrence of AKI after LAAC. METHODS: A total of 355 patients undergoing LAAC were included in the study. AKI was defined as an absolute or a relative increase in serum creatinine of >0.3 mg/dl or ≥50%, respectively, after the procedure or the need for hemodialysis during index hospitalization. RESULTS: The incidence of AKI was 9%, and patients with worse baseline renal function were at higher risk for developing AKI (odds ratio: 1.32; 95% confidence interval [CI]: 1.09 to 1.61; p = 0.004 for each 10 ml/min decrease in glomerular filtration rate). In-hospital bleeding events occurred more frequently in the AKI group (5.3% vs. 15.6%; p = 0.037). After a median follow-up period of 18 months, patients in the AKI group had higher mortality (hazard ratio [HR]: 2.59; 95% CI: 1.36 to 4.92; p = 0.004), more embolic events (HR: 6.14; 95% CI: 2.23 to 16.92; p = 0.001) and major bleeding events (HR: 2.36; 95% CI: 0.89 to 6.24; p = 0.083). The occurrence of AKI was an independent predictor of midterm mortality (HR: 2.00; 95% CI: 1.02 to 3.91; p = 0.044). CONCLUSIONS: The occurrence of AKI was relatively frequent following LAAC, and patients with lower renal glomerular filtration rates were at high risk for developing this complication. AKI identified a group of patients with worse midterm outcomes, highlighting the importance of further preventive strategies in this population.


Asunto(s)
Lesión Renal Aguda/epidemiología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/efectos adversos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/terapia , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/mortalidad , Canadá/epidemiología , Cateterismo Cardíaco/mortalidad , Femenino , Tasa de Filtración Glomerular , Humanos , Incidencia , Riñón/fisiopatología , Masculino , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , España/epidemiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA