Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Photochem Photobiol B ; 163: 269-76, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27599114

RESUMEN

Achyrocline satureioides is a medicinal plant widely used in South America that exhibits a well-documented antioxidant activity. Such activity has been related to their main aglycone flavonoids quercetin, luteolin, and 3-O-methylquercetin (3MQ). This study addresses the development of antioxidant hydrogels containing an A. satureioides extract-loaded nanoemulsions aimed at topical application. The systems investigated were A. satureioides extract-loaded nanoemulsions (ASNE) obtained by spontaneous emulsification procedure formulated in semisolid hydrogels composed of Carbopol® Ultrez 20 (HASNE). Hydrogels exhibit a non-Newtonian pseudoplastic behavior. A higher release of 3MQ from ASNE (3.61µg/cm(2)/h) was observed when compared with HASNE (2.83µg/cm(2)/h). Different parameters that may have an influence on the retention of flavonoids into the skin were investigated by using a Franz-type diffusion cells. Indeed, the amount of formulation applied on donor compartment was found to play a crucial role. At the optimized conditions, retention of approximately 2µg/cm(2) of flavonoids was detected into the skin. A higher retention of 3MQ was detected (approximately 1.0µg/cm(2)) in comparison with the other flavonoids. Finally, a protection the porcine ear skin by formulations, against oxidative stress generated by UVA/UVB light was demonstrated by means of TBARS, protein carbonylation, and protein thiol content assays. The overall results showed the potential of the formulations developed in this study for the prevention of oxidative stress on the skin.


Asunto(s)
Achyrocline/química , Hidrogeles/química , Nanoestructuras/química , Extractos Vegetales/química , Extractos Vegetales/farmacología , Piel/efectos de los fármacos , Piel/efectos de la radiación , Antioxidantes/química , Antioxidantes/metabolismo , Antioxidantes/farmacología , Composición de Medicamentos , Liberación de Fármacos , Emulsiones , Flavonoides/metabolismo , Estrés Oxidativo/efectos de los fármacos , Permeabilidad/efectos de los fármacos , Permeabilidad/efectos de la radiación , Extractos Vegetales/metabolismo , Protectores contra Radiación/química , Protectores contra Radiación/metabolismo , Protectores contra Radiación/farmacología , Piel/citología , Piel/metabolismo , Viscosidad
2.
J Vasc Interv Radiol ; 12(11): 1279-84, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11698626

RESUMEN

PURPOSE: To determine (i) whether there is a significant increase in hepatic artery blood flow (HABF) after transjugular intrahepatic portosystemic shunt (TIPS) creation and (ii) whether the extent of incremental increase in HABF is predictive of clinical outcome after TIPS creation. MATERIALS AND METHODS: Prospective, nonrandomized, nonblinded duplex Doppler ultrasound (US) examinations were performed on 24 consecutive patients (19 men; Child Class A/B/C: 4/12/8, respectively) with a mean age of 52.8 years who were referred for TIPS creation for variceal bleeding. Peak hepatic artery velocity and vessel dimensions were used to calculate the hepatic arterial blood flow (HABF) before and after TIPS creation. Patients were clinically followed in the gastrohepatology clinic and TIPS US surveillance was performed at 1 and 3 months to assess shunt function. The extent of incremental increase in HABF was analyzed as a predictor of post-TIPS encephalopathy and/or death. RESULTS: The technical success rate of TIPS creation was 100%. The shunt diameters were either 10 mm (n = 11) or 12 mm (n = 13). TIPS resulted in a significant reduction in the portosystemic gradient from 24.3 mm Hg +/- 5.7 to 9.3 mm Hg +/- 2.9 (P <.001). The hepatic artery peak systolic velocity and HABF increased significantly after TIPS creation, from 60.8 cm/sec +/- 26.7 to 121 cm/sec +/- 51.5 (P <.001) and from 254.2 mL/min +/- 142.2 to 507.8 mL/min +/- 261.3 (P <.001), respectively. The average incremental increase in HABF from pre-TIPS to post-TIPS was 253.6 mL/min +/- 174.2 and the average decremental decrease in portosystemic gradient was 15.0 mm Hg +/- 5.3, but there was no significant correlation (r = 0.04; P =.86) between the two. All shunts were patent at 30 and 90 days without sonographic evidence of shunt dysfunction. After TIPS creation, new or worsened encephalopathy developed in five patients at 30 days and in an additional three at 90 days. They were all successfully managed medically. Three patients (12.5%) died within 30 days of the TIPS procedure. The extent of incremental increase in HABF after TIPS was variable and did not correlate with the development of 30-day and 90-day encephalopathy (P =.41 and P =.83, respectively) or 30-day mortality (P =.2). CONCLUSIONS: HABF increases significantly after TIPS but is not predictive of clinical outcome. The significance of the incremental increase is yet to be determined.


Asunto(s)
Várices Esofágicas y Gástricas/cirugía , Hemorragia Gastrointestinal/cirugía , Arteria Hepática/diagnóstico por imagen , Hepatopatías/cirugía , Derivación Portosistémica Intrahepática Transyugular , Ultrasonografía Doppler Dúplex , Adulto , Anciano , Análisis de Varianza , Velocidad del Flujo Sanguíneo , Várices Esofágicas y Gástricas/diagnóstico por imagen , Várices Esofágicas y Gástricas/mortalidad , Femenino , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/mortalidad , Encefalopatía Hepática/etiología , Humanos , Hepatopatías/diagnóstico por imagen , Hepatopatías/mortalidad , Masculino , Persona de Mediana Edad , Vena Porta/diagnóstico por imagen , Valor Predictivo de las Pruebas , Estudios Prospectivos , Resultado del Tratamiento
3.
J Vasc Interv Radiol ; 12(8): 985-9, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11487680

RESUMEN

PURPOSE: To compare, with use of intravascular ultrasound (IVUS) as an internal reference standard in a porcine model, arterial diameters measured from arteriograms obtained with use of CO(2) to those obtained with use of iodinated contrast material (ICM). MATERIALS AND METHODS: In nine pigs, digital subtraction angiograms (DSAs) were obtained in the aorta and iliac arteries to compare vessel diameters measured with use of CO(2) to those measured with use of ICM. These measurements were divided by measurements made with use of intravascular ultrasound (IVUS) to yield a DSA/IVUS ratio. Differences between ICM and CO(2) were compared with analysis of variance to assess the effect of location (aorta vs iliac), contrast material used (ICM vs CO(2)), and position (posteroanterior, right anterior oblique, or left anterior oblique). Secondary analysis compared measurements of dependent and nondependent iliac arteries and compared the use of hand-injected CO(2) to that of CO(2) injected by an injector. RESULTS: The DSA/IVUS ratio was 70.7% +/- 4.4% with ICM use and 69.6% +/- 6.3% with CO(2) use, which did not represent a significant difference (P =.311). Animal position had no effect (P =.477). Underestimation was worse in the iliac arteries than in the aorta (67.4% +/- 1.5% vs 71.4% +/- 1.7%; P =.038). There was no difference in nondependent (P =.163) arteries, but CO(2) underestimated dependent iliac artery size more than ICM did (66.3% +/- 4.8% vs 70.3% +/- 5.4%; P =.051). Vessel diameter was underestimated more with the CO(2) injector than with hand-injected CO(2) (64.3% +/- 2.3% vs 71.7% +/- 1.7%; P <.0001). CONCLUSION: There is no difference in diameter underestimation between CO(2) and ICM in this animal model. Hand-injection of CO(2) causes less underestimation of vessel diameter than does the CO(2) injector.


Asunto(s)
Angiografía/métodos , Aorta Abdominal/ultraestructura , Dióxido de Carbono , Medios de Contraste , Arteria Ilíaca/diagnóstico por imagen , Yodo , Animales , Aorta Abdominal/diagnóstico por imagen , Cobayas , Modelos Animales , Ultrasonografía
5.
Radiology ; 219(3): 663-7, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11376251

RESUMEN

PURPOSE: To determine the predisposing factors to transplant renal arterial stenosis (TRAS) and assess the outcome of percutaneous transluminal angioplasty (PTA) as the primary treatment. MATERIALS AND METHODS: Of 831 renal allograft recipients (584 cadaveric, 247 living related) between January 1991 and December 1998, 72 had hypertension and/or renal dysfunction. All 72 underwent arteriography, and their medical charts were retrospectively reviewed. RESULTS: Prevalence of TRAS was 3.1% (26 of 831). Technical success rate of PTA was 94% (16 of 17), and clinical success rate was 82% (14 of 17). Those with renal dysfunction had a mean pre-PTA creatinine value of 2.6 mg/dL (230 micromol/L) +/- 0.5 (SD) versus a 1-week post-PTA value of 1.7 mg/dL (150 micromol/L) +/- 0.3 (P <.001). Of those with hypertension, all but one had substantial improvement in mean diastolic blood pressure. At 26.9 months mean follow-up in 16 patients with successful PTA, two stenoses reoccurred, and two grafts were lost to chronic rejection. TRAS was present in 14 of 45 end-to-side anastomoses and 12 of 27 end-to-end anastomoses (P =.31), and TRAS was more prevalent in cadaveric grafts (24 of 584) than in living related grafts (two of 247). In cadaveric grafts, the mean cold ischemia time was 29.0 hours +/- 6.9 in those with TRAS (n = 24), as compared with 25.5 hours +/- 8.1 in those with no TRAS (n = 39; P = .35). Seven of 17 patients with acute rejection and six of 35 with chronic rejection had TRAS. CONCLUSION: Primary treatment of TRAS with PTA has good intermediate-term results. TRAS is more prevalent in cadaveric allografts with long cold ischemia time.


Asunto(s)
Angioplastia de Balón , Trasplante de Riñón , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Obstrucción de la Arteria Renal/epidemiología , Obstrucción de la Arteria Renal/terapia , Adulto , Cadáver , Causalidad , Femenino , Humanos , Donadores Vivos , Masculino , Prevalencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
6.
J Vasc Interv Radiol ; 11(4): 437-44, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10787201

RESUMEN

PURPOSE: Precise vessel sizing prior to endovascular intervention is critical to achievement of technical success. Diameter measurements obtained with CO2 and iodinated contrast material in an aortoiliac flow model were compared. MATERIALS AND METHODS: Aortoiliac flow was simulated in a compliant, silicone elastomer phantom of the aortoiliac system using an autoperfusion pump (flow volume, approximately 1100 mL/min; mean arterial pressure, 70-80 mm Hg at 80-90 cycles/minute) and a glycerol solution (40% by weight; viscosity 3.7 centipoise at 20 degrees C). Digital subtraction angiography was performed with the phantom in the anteroposterior (AP) plane and in three oblique planes with both CO2 and iodinated contrast material. Five sets of images for both CO2 and iodinated contrast material were obtained for each projection. Two readers independently performed vessel diameter measurements at seven sites (distal abdominal aorta, bilateral proximal and distal common iliac, and mid-external iliac arteries). The model was then evaluated with intravascular ultrasound (IVUS) using a 20-MHz imaging catheter. Actual diameter measurements were taken from the inner wall to inner wall in orthogonal planes at the same locations within the model, as described previously. Analysis was performed to determine local difference in measurements (t tests), difference when compared to the standard AP projection with iodinated contrast material (Dunnett's test) and inter-reader variability (Pitman's test). RESULTS: The contralateral iliac vessel segment did not opacify when imaging with CO2 in the 45 degrees obliquities; thus, 22 of 28 sites were available for comparison. At 18 of 22 (81.8%) sites, there was significant difference in vessel measurements (P < .01), with CO2 yielding a significantly larger diameter at 17 of 22 (77.3%) of the sites. The difference in mean diameter ranged from -1.28 to 4.47 mm. With use of the AP iodinated contrast material run as the standard, there were significant differences (P < .05) in vessel diameter at 17 of 22 (77.3%) and four of 21 (19%) sites for CO2 and iodinated contrast material respectively, with CO2 tending toward greater diameter measurements. Significant differences (P < .05) in variance between the two readers were present but occurred primarily with CO2 in the AP projection and iodinated contrast material in the 45 degrees left obliquity. With use of IVUS as the standard, there were significant differences (P < .05) in the measured vessel diameters with CO2 at nine of 22 (40.9%) of the sites and with iodinated contrast material at 17 of 28 (60.7%) of the sites. Of the measurements made with CO2, seven of nine (77.8%) of the measurements were of larger diameter than those obtained with IVUS. By contrast, of the measurements made with iodinated contrast material angiography, IVUS measured larger diameters in 16 of 17 (94.1%). CONCLUSION: CO2 angiography consistently yielded significantly larger vessel measurements when compared to both iodinated contrast angiography and WVUS. These results have important implications in regards to planning intervention based solely on CO2 angiography. Further evaluation is needed before recommending CO2 for vessel sizing in clinical practice.


Asunto(s)
Angiografía de Substracción Digital , Aorta Abdominal/diagnóstico por imagen , Dióxido de Carbono , Arteria Ilíaca/diagnóstico por imagen , Yodo , Modelos Anatómicos , Medios de Contraste , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Ultrasonografía
7.
J Vasc Interv Radiol ; 11(3): 382-90, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10735436

RESUMEN

PURPOSE: To test the technical feasibility of creating a left ventricle to coronary sinus shunt using endovascular techniques. MATERIALS AND METHODS: By means of a right jugular vein approach, a needle puncture was made from the coronary sinus to the left ventricle in 10 dogs. The tracts were balloon dilated and lined with 6-mm Wallstents. Shunt patencies, immediate and 4-hours later, were fluoroscopically assessed by contrast material injection into the left ventricle. Blood pressure, pulse, oxygen saturation, and cardiac rhythm were monitored. The dogs were then euthanized. Thoracic cavities and hearts were dissected and inspected. RESULTS: Technical success and immediate shunt patency were 100%. No cardiac dysrhythmias, electrocardiographic changes, or reduction in voltage potential were seen. Eight (80%) of the shunts were patent at 4 hours, one (10%) had thrombosed, and one dog died. Nine (90%) dogs had no pericardial hematoma and one (10%) had minimal pericardial blood from needle passes into the pericardial sac. The coronary sinuses were intact and no injuries to the valve leaflets or chordae tendineae were seen. The puncture sites were from the coronary sinus, 1-2 mm (mean, 1.3) from its auricular orifice, into the left ventricle, just below the inferior margin of the posterior leaflet of the mitral valve. One dog died at 3 hours with no preceding electrocardiographic evidence of impending demise. Autopsy showed no pericardial hematoma and the heart findings were no different from the other nine dogs. CONCLUSIONS: Creation of a left ventricle to coronary sinus shunt with use of endovascular techniques is technically feasible. Study of a transmyocardial intracardiac coronary retroperfusion shunt to deliver oxygenated blood to the ischemic myocardium is warranted.


Asunto(s)
Vasos Coronarios/cirugía , Ventrículos Cardíacos/cirugía , Isquemia Miocárdica/cirugía , Revascularización Miocárdica/métodos , Anastomosis Quirúrgica , Animales , Angiografía Coronaria , Modelos Animales de Enfermedad , Perros , Estudios de Factibilidad , Femenino , Isquemia Miocárdica/diagnóstico por imagen , Resultado del Tratamiento
8.
Radiology ; 213(1): 301-2, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10540676

RESUMEN

Functioning hemodialysis grafts were used as access sites for peripheral vascular arteriography and interventional procedures. In 11 patients with end-stage renal disease and ischemia, upper extremity (n = 8) or lower extremity (n = 3) arteriography was performed successfully. Angioplasty and other interventional procedures were performed via the same route in two of the patients. No bleeding complications occurred, and all patients were ambulatory immediately after the procedure.


Asunto(s)
Angiografía/métodos , Derivación Arteriovenosa Quirúrgica , Extremidades/irrigación sanguínea , Radiografía Intervencional , Diálisis Renal , Catéteres de Permanencia , Humanos
9.
Radiology ; 213(1): 303-6, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10540677

RESUMEN

In 34 patients with chronic renal insufficiency or failure, 43 small-bore central catheters were placed via the internal or external jugular veins: right internal jugular vein, 28; left internal jugular vein, 14; right external jugular vein, one. Central venous access was achieved in all patients (mean catheter dwell time, 28 days; range, 3-99 days), with two minor complications (arterial puncture and catheter damage during suturing). Tunneled jugular small-bore central catheters are a vein-preserving alternative to peripherally inserted central catheters in this population.


Asunto(s)
Cateterismo Venoso Central , Fallo Renal Crónico/terapia , Diálisis Renal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diálisis Renal/instrumentación , Diálisis Renal/métodos
10.
J Vasc Interv Radiol ; 10(8): 1025-31, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10496703

RESUMEN

PURPOSE: To assess the safety and efficacy of using the Arrow-Trerotola percutaneous thrombolytic device (PTD) as the sole means of mechanical thrombolysis in hemodialysis access grafts, including in situ treatment of the arterial plug. PATIENTS AND METHODS: Fifty consecutive patients (22 women, 28 men; mean age, 58 years; mean graft age, 29 months), in whom mechanical thrombolysis of a thrombosed hemodialysis access graft using the PTD was planned, were included in the study. In all patients, the PTD was used to treat the arterial plug in situ at the arterial anastomosis, instead of using a Fogarty catheter to reposition the plug, as indicated in the PTD product labeling. Prospective data collection included demographic information, technical details of the procedure, immediate outcomes, and complications. Patients were followed for 3 months using definitions and data forms that were identical to those used in the original clinical trial of the PTD. A sample of procedures drawn from the PTD clinical trial database (n = 54) served as control. RESULTS: Immediate technical patency was 100%. Complications included arterial embolization (6% versus 2% control; P = NS; all successfully treated with backbleeding); venous rupture (6% versus 2% control; P = NS); and sepsis (n = 1), probably due to occult graft infection. Adjunctive therapy with an Adherent Clot catheter was needed in two procedures (4%). Three month patency using life-table analysis was 42% (versus 39% control; P = NS). The number of subsequent interventions (surgical/percutaneous) to the arterial limb of the graft did not differ from the PTD trial, and no native arterial stenoses were detected during the follow-up period. CONCLUSIONS: The PTD is safe and effective when used as the sole means of mechanical thrombolysis of hemodialysis grafts. Treating the arterial plug in situ with the PTD eliminates the need for a Fogarty or Adherent Clot catheter in 96% of procedures. A slight increase in arterial embolic complications was observed but these were easily treated with backbleeding.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Oclusión de Injerto Vascular/cirugía , Diálisis Renal , Trombectomía/instrumentación , Trombosis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Seguridad , Succión , Resultado del Tratamiento
11.
J Vasc Interv Radiol ; 10(8): 1032-8, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10496704

RESUMEN

PURPOSE: To evaluate short-term flow rates achieved with a new split-tip polyurethane hemodialysis catheter. PATIENTS AND METHODS: This was a prospective, randomized, nonblinded study. Patients referred for a tunneled-dialysis catheter received either a conventional silicone (Bard Hickman 13.5 F) if randomized to the control group, or a split-tip, high-flow polyurethane (MedComp AshSplit 14.5 F) catheter if randomized to the study group. Effective flow rates (QbEff) and recirculation were measured with use of ultrasonic dilution at pump settings (Qb) of 200, 300, 350 and 400 mL/min, as well as maximum Qb (QbMax, up to 500 mL/min) sustainable for at least 3 minutes. Measurements were repeated weekly for 6 weeks. Procedure times and initial and late complications were recorded. RESULTS: Twelve patients were enrolled in each group, 11 and eight completed the study in the test and control groups, respectively. Insertion complications, limited to the split-tip group, included asymptomatic air embolus (n = 1), prolonged tunnel bleeding (n = 2), and kinking (n = 2). Recirculation in both groups was low (mean < 6% at all flow rates). QbMax was 499 mL/min in the Ash group and 470 mL/min in the Hickman group. A repeated measures analysis of variance was used. Adjusted (for week) mean effective flow rates (Qbeff, mL/min) were as follows: at Qb = 200, Ash = 211, Bard = 211, P = .93; at Qb = 300, Ash = 301, Bard = 292, P = .28; at Qb = 350, Ash = 341, Bard = 314, P = .03; at Qb = 400, Ash = 375, Bard = 329, P = .01; at QbMax, Ash = 422, Bard = 359, P = .0005. CONCLUSION: Both catheters delivered flows within the acceptable range indicated by the Dialysis Outcomes Quality Initiative. The split-tip catheter is capable of higher flow rates (Qb and QbEff) compared with the conventional catheter, which may allow more efficient dialysis. Insertion complications appear to be higher with the new design.


Asunto(s)
Catéteres de Permanencia , Diálisis Renal/instrumentación , Velocidad del Flujo Sanguíneo , Soluciones para Diálisis , Femenino , Humanos , Venas Yugulares/fisiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional
13.
AJR Am J Roentgenol ; 171(5): 1271-6, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9798859

RESUMEN

OBJECTIVE: We evaluated the usefulness of carbon dioxide as the primary contrast material for renal transplant arteriography. CONCLUSION: Carbon dioxide accurately showed artery pathology including anastomotic and intrarenal stenoses, arteriovenous shunting, and diffuse arterial disease from chronic transplant rejection. Using carbon dioxide as a contrast agent reduced the volume of iodinated contrast material that needed to be used. There was no procedure-associated nephrotoxicity.


Asunto(s)
Dióxido de Carbono , Medios de Contraste , Trasplante de Riñón/diagnóstico por imagen , Arteria Renal/diagnóstico por imagen , Adulto , Angiografía/métodos , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/etiología , Femenino , Humanos , Trasplante de Riñón/efectos adversos , Masculino , Persona de Mediana Edad , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/etiología
16.
J Vasc Interv Radiol ; 9(2): 187-98, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9540901

RESUMEN

PURPOSE: Pseudoaneurysms represent contained disruption of the arterial wall. Iatrogenic pseudoaneurysms frequently complicate complex endovascular procedures. With use of an animal model, the authors attempted to determine the safety and efficacy of using a perfusion balloon catheter (PBC) to thrombose surgically created pseudoaneurysms. MATERIALS AND METHODS: An in vitro system measured maximum flow volume through a 5-F PBC. Pseudoaneurysms were created in domestic swine with use of a jugular vein patch anastomosed to a femoral arteriotomy. The PBC was inflated across the pseudoaneurysm neck for 30-minute intervals until thrombosis was confirmed by ultrasound. Completion arteriography was performed to evaluate for vascular complications. RESULTS: Maximum flow through the PBC was 62.6 mL/min measured at a constant pressure gradient of 120 mm Hg. Five pseudoaneurysms were created in four animals. The PBC completely thrombosed all five lesions. The mean treatment duration was 129 minutes (+/- 39 minutes SD). No native arterial injury, in situ thrombus, or distal embolization occurred. Partial recanalization of three of the five treated pseudoaneurysms was identified on follow-up arteriography and gross sectioning (n = 2 and n = 1, respectively). CONCLUSION: The PBC safely and effectively thrombosed surgically created pseudoaneurysms. Partial recanalization of treated pseudoaneurysms was demonstrated. Clinical trials are warranted.


Asunto(s)
Aneurisma Falso/terapia , Cateterismo , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/patología , Animales , Distinciones y Premios , Cateterismo Periférico/efectos adversos , Embolización Terapéutica , Arteria Femoral/patología , Radiografía Intervencional , Sociedades Médicas , Porcinos , Trombosis
17.
Comput Med Imaging Graph ; 19(5): 427-30, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-8734781

RESUMEN

Abdominal aortic coarctation is an uncommon entity in the elderly. We present a case of abdominal aortic coarctation with computed tomography (CT), magnetic resonance imaging (MRI) and conventional angiographic correlation. CT and MR imaging detected an abnormal abdominal aorta distal to the origin of the celiac axis with the diagnosis of abdominal aortic coarctation confirmed by conventional angiography. Clinical presentation and diagnostic imaging findings depend on the level of the coarctation and its relationship to the renal vessels.


Asunto(s)
Aorta Abdominal/anomalías , Coartación Aórtica/diagnóstico , Aortografía , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/patología , Coartación Aórtica/diagnóstico por imagen , Arteria Celíaca/diagnóstico por imagen , Arteria Celíaca/patología , Femenino , Humanos , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Arteria Renal/patología , Venas Renales/diagnóstico por imagen , Venas Renales/patología
19.
Clin Imaging ; 18(2): 93-5, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-8033012

RESUMEN

An unusual case of renal lymphoma occurring in a patient with Castleman's disease is presented. The radiographic features and the relationship to the lymphoproliferative disorders, Castleman's disease, and multicentric angiofollicular lymph node hyperplasia are described.


Asunto(s)
Enfermedad de Castleman/complicaciones , Neoplasias Renales/etiología , Linfoma/etiología , Adulto , Humanos , Neoplasias Renales/diagnóstico por imagen , Linfoma/diagnóstico por imagen , Masculino , Tomografía Computarizada por Rayos X , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...