Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38708449

RESUMEN

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.

2.
Cont Lens Anterior Eye ; : 102155, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38609792

RESUMEN

Presbyopia is often the first sign of ageing experienced by humans. Standardising terminology and adopting it across the BCLA CLEAR Presbyopia reports, improves consistency in the communication of the evidence-based understanding of this universal physiological process. Presbyopia can be functionally and psychologically debilitating, especially for those with poor access to eyecare. Presbyopia was defined as occurring when the physiologically normal age-related reduction in the eye's focusing range reaches a point that, when optimally corrected for far vision, the clarity of vision at near is insufficient to satisfy an individual's requirements. Accommodation is the change in optical power of the eye due to a change in crystalline lens shape and position, whereas pseudo-accommodation is the attainment of functional near vision in an emmetropic or far-corrected eye without changing the refractive power of the eye. Other definitions specific to vision and lenses for presbyopia were also defined. It is recommended that these definitions be consistently adopted in order to standardise future research, clinical evaluations and education.

3.
Cont Lens Anterior Eye ; : 102158, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38631935

RESUMEN

This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike.

4.
Cont Lens Anterior Eye ; : 102156, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38641525

RESUMEN

It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.

5.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578134

RESUMEN

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Asunto(s)
Lentes de Contacto , Anteojos , Fijación Ocular , Presbiopía , Lectura , Refracción Ocular , Agudeza Visual , Humanos , Presbiopía/fisiopatología , Presbiopía/terapia , Femenino , Masculino , Persona de Mediana Edad , Agudeza Visual/fisiología , Fijación Ocular/fisiología , Refracción Ocular/fisiología , Adulto , Movimientos de la Cabeza/fisiología , Movimientos Oculares/fisiología
6.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38546401

RESUMEN

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Asunto(s)
Parpadeo , Lentes de Contacto Hidrofílicos , Lágrimas , Humanos , Lentes de Contacto Hidrofílicos/efectos adversos , Masculino , Femenino , Adulto , Lágrimas/metabolismo , Lágrimas/fisiología , Proyectos Piloto , Parpadeo/fisiología , Adulto Joven , Concentración Osmolar , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Párpados
7.
J. optom. (Internet) ; 16(4): 296-304, October - December 2023. tab, graf
Artículo en Inglés | IBECS | ID: ibc-225619

RESUMEN

Purpose: This work seeks to identify the most impactful journals, papers, authors, institutions, and countries that cite optometry journal articles. Methods: The Scopus database was searched for papers citing at least one article published in any of the 18 optometry journals included in that database (i.e. ‘optometry articles’). The 10 most highly cited papers that cite optometry journal articles were determined from 82,830 papers found. A h-index for “optometry journal citations” (the hOJC-index) was derived for each entity in the categories of journals, papers, authors, institutions and countries to serve as a measure of impact. Results: The hOJC-index of the body of papers citing optometry journal articles is 370. Papers citing optometry journal articles have themselves been cited 2,054,816 times. Investigative Ophthalmology & Visual Science (hOJC = 154) is the most impactful journal citing optometry articles and Optometry and Vision Science the most prolific (5310 papers). The most impactful paper citing optometry journal articles (5725 citations) was published in Journal of Clinical Epidemiology. Ophthalmologist Seang Mei Saw (hOJC = 69) is the most impactful author and optometrist Nathan Efron is the most prolific (288 papers). Harvard University (hOJC = 127) is the most impactful and UNSW Sydney is the most prolific institution (1761 papers). The United States is the most impactful and prolific nation (hOJC = 313; 28,485 papers). Conclusions: Optometry journal articles are cited extensively by optometrists, ophthalmologists, and vision scientists world-wide, as well as authors from a broad spectrum of non-ophthalmic research domains. This work confirms the utility and influence of optometry journals. (AU)


Asunto(s)
50088 , Factor de Impacto de la Revista , Publicaciones Periódicas como Asunto , Optometría/tendencias
8.
Clin Exp Optom ; : 1-11, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37989323

RESUMEN

CLINICAL RELEVANCE: Evaluating how Meibomian glands can change in appearance has the potential to advance the understanding of Meibomian gland health and may lead to enhanced diagnosis and therapy. BACKGROUND: This work aimed to investigate Meibomian gland appearance after therapeutic Meibomian gland expression. METHODS: Fifteen subjects attended three study visits over a two-week period. Meibography was performed before and after therapeutic Meibomian gland expression, the following day, and 2 weeks after expression. Six central glands were used to calculate Meibomian gland morphological parameters such as gland length ratio, gland width, gland area, gland tortuosity, and gland contrast. A custom semi-automated image analysis software was used to calculate Meibomian gland metrics. Furthermore, a high-resolution imaging system was developed to capture clear images of the Meibomian glands, free of any artefacts, which were used for precise calculations of Meibomian gland contrast. RESULTS: The expression procedure had a significant impact on Meibomian gland contrast and length ratio immediately afterwards. The least square mean difference (95% CI) from baseline for Michelson contrast was -0.006 (-0.010, -0.001) and -1.048 (-2.063, -0.033) for simple contrast. The least square mean ratio of the gland length ratio immediately after the expression to baseline was 0.758 (0.618, 0.931). CONCLUSIONS: Following therapeutic expression, Meibomian glands exhibit reduced brightness and length. However, within 24 h, they appear to recover and return to their baseline state, indicating a relatively short recovery time. This sheds light on whether meibography is solely focused on capturing gland structure or if it also captures acinar activity. The hyperreflective properties of lipids suggest that the decrease in contrast observed after expression could be attributed to a reduction in the visualisation of acini activity. A decrease in Meibomian gland length ratio implies that the loss of gland structure following treatment may be indicative of a temporary structural alteration.

9.
Ophthalmol Sci ; 3(4): 100334, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37920420

RESUMEN

Purpose: To develop and evaluate a deep learning algorithm for Meibomian gland characteristics calculation. Design: Evaluation of diagnostic technology. Subjects: A total of 1616 meibography images of both the upper (697) and lower (919) eyelids from a total of 282 individuals. Methods: Images were collected using the LipiView II device. All the provided data were split into 3 sets: the training, validation, and test sets. Data partitions used proportions of 70/10/20% and included data from 2 optometry settings. Each set was separately partitioned with these proportions, resulting in a balanced distribution of data from both settings. The images were divided based on patient identifiers, such that all images collected for one participant could end up only in one set. The labeled images were used to train a deep learning model, which was subsequently used for Meibomian gland segmentation. The model was then applied to calculate individual Meibomian gland metrics. Interreader agreement and agreement between manual and automated methods for Meibomian gland segmentation were also carried out to assess the accuracy of the automated approach. Main Outcome Measures: Meibomian gland metrics, including length ratio, area, tortuosity, intensity, and width, were measured. Additionally, the performance of the automated algorithms was evaluated using the aggregated Jaccard index. Results: The proposed semantic segmentation-based approach achieved average aggregated Jaccard index of mean 0.4718 (95% confidence interval [CI], 0.4680-0.4771) for the 'gland' class and a mean of 0.8470 (95% CI, 0.8432-0.8508) for the 'eyelid' class. The result for object detection-based approach was a mean of 0.4476 (95% CI, 0.4426-0.4533). Both artificial intelligence-based algorithms underestimated area, length ratio, tortuosity, widthmean, widthmedian, width10th, and width90th. Meibomian gland intensity was overestimated by both algorithms compared with the manual approach. The object detection-based algorithm seems to be as reliable as the manual approach only for Meibomian gland width10th calculation. Conclusions: The proposed approach can successfully segment Meibomian glands; however, to overcome problems with gland overlap and lack of image sharpness, the proposed method requires further development. The study presents another approach to utilizing automated, artificial intelligence-based methods in Meibomian gland health assessment that may assist clinicians in the diagnosis, treatment, and management of Meibomian gland dysfunction. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

10.
Cont Lens Anterior Eye ; 46(5): 101887, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37460374

RESUMEN

PURPOSE: To determine clinical performance and the 'Willingness To Pay' for toric vs. spherical soft contact lenses in an astigmatic population. METHODS: In the clinical study, subjects with binocular low to moderate astigmatism (-0.75DC to -1.50DC) wore pairs of soft toric (Biofinity toric) and spherical (Biofinity) contact lenses in random sequence. Visual acuity (high and low contrast, monocular and binocular), subjective comfort and subjective vision were recorded. In the economics study, first subjects who had participated in the clinical study were presented with a series of randomised economic scenarios in order to determine their Willingness To Pay a premium (i.e. an increase) for toric lenses. Then, a similar set of scenarios were presented to a much larger group of online respondents and again, Willingness To Pay was established. RESULTS: For the four measures of visual acuity, the Biofinity toric lens out-performed the Biofinity spherical lens by 0.6 to 1.1 lines.. Subjective vision performance was statistically significantly better with the toric lens for the distance task only. Comfort scores were not significantly different. Similar findings for Willingness To Pay were established for the clinical subjects and for the online respondents. The Willingness To Pay premium (additional fee) for a monthly supply of toric lenses (over spherical lenses) was between £13 and £16, if a toric lens provides better vision and similar comfort, as shown in the clinical study. CONCLUSION: Consumers are willing to pay a monthly premium of around 50% to benefit from the typical experience of better vision and similar comfort for toric vs. spherical lenses. The level of additional cost for toric lenses compared to their spherical equivalents is less than this in the market, so eye care professionals should consider that toric lenses are delivering a greater clinical return than anticipated by wearers for the relatively small increase in price.


Asunto(s)
Astigmatismo , Lentes de Contacto Hidrofílicos , Humanos , Agudeza Visual , Refracción Ocular , Astigmatismo/terapia
11.
J Optom ; 16(4): 296-304, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37271623

RESUMEN

PURPOSE: This work seeks to identify the most impactful journals, papers, authors, institutions, and countries that cite optometry journal articles. METHODS: The Scopus database was searched for papers citing at least one article published in any of the 18 optometry journals included in that database (i.e. 'optometry articles'). The 10 most highly cited papers that cite optometry journal articles were determined from 82,830 papers found. A h-index for "optometry journal citations" (the hOJC-index) was derived for each entity in the categories of journals, papers, authors, institutions and countries to serve as a measure of impact. RESULTS: The hOJC-index of the body of papers citing optometry journal articles is 370. Papers citing optometry journal articles have themselves been cited 2,054,816 times. Investigative Ophthalmology & Visual Science (hOJC = 154) is the most impactful journal citing optometry articles and Optometry and Vision Science the most prolific (5310 papers). The most impactful paper citing optometry journal articles (5725 citations) was published in Journal of Clinical Epidemiology. Ophthalmologist Seang Mei Saw (hOJC = 69) is the most impactful author and optometrist Nathan Efron is the most prolific (288 papers). Harvard University (hOJC = 127) is the most impactful and UNSW Sydney is the most prolific institution (1761 papers). The United States is the most impactful and prolific nation (hOJC = 313; 28,485 papers). CONCLUSIONS: Optometry journal articles are cited extensively by optometrists, ophthalmologists, and vision scientists world-wide, as well as authors from a broad spectrum of non-ophthalmic research domains. This work confirms the utility and influence of optometry journals.


Asunto(s)
Oftalmología , Optometría , Publicaciones Periódicas como Asunto , Humanos , Estados Unidos , Bibliometría , Bases de Datos Factuales
12.
JAMA Ophthalmol ; 141(7): 651-657, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37261835

RESUMEN

Importance: The primary vehicle for reporting and testing advances in eye care is refereed ophthalmic journals, which can be characterized using targeted bibliometric analyses. Objective: To identify all ophthalmic journals and evaluate citation metrics relating to articles, journals, authors, institutions, and countries published therein. Design and Setting: A bibliometric analysis was undertaken of all ophthalmic journals included in the Scopus database (Elsevier). The search was restricted to all article types published in ophthalmic journals in English from inception through November 18, 2022. After excluding general medical journals, journals published in a language other than English, and spurious titles unrelated to the ophthalmic field, the Scopus database was found to list 335 ophthalmic journal titles that have published 471 184 articles, constituting the data set for this analysis. The 20 most highly cited articles were identified. Rank-order lists by article count were assembled for journals, authors, institutions, and countries. Main Outcomes and Measures: An h-index for ophthalmic journal articles was derived from citations and article counts for each constituent of each category. Results: The h-index for ophthalmic journal articles was determined to be 494. The journal with the highest h-index was Ophthalmology (h-index, 297). The journal with the greatest number of articles was American Journal of Ophthalmology (38 441 articles). The most highly cited article was by Quigley and Broman, 2006 (5147 citations), concerning the epidemiology of glaucoma. The author with the highest h-index for ophthalmic journal articles was Ronald Klein, MD (h-index, 126), and the most prolific was Carol L. Shields, MD (1400 articles). Johns Hopkins University (h-index, 215) was the institution with the highest h-index for ophthalmic journal articles, and Harvard University was the most prolific (10 071 articles). The United States was the nation with the highest h-index for ophthalmic journal articles (h-index, 444) and was the most prolific (180 017 articles). Conclusions and Relevance: In this study, the most highly cited articles published in ophthalmic journals were revealed, as well as the leading journals, authors, institutions, and countries. While excluding ophthalmology articles in general medical journals, this investigation affords a means of identifying highly cited authors, institutions, and countries which individuals or institutions can use as a guide regarding contributions to the field.


Asunto(s)
Oftalmología , Publicaciones Periódicas como Asunto , Humanos , Estados Unidos , Bibliometría , Publicaciones
13.
Cont Lens Anterior Eye ; 46(3): 101827, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36935225

RESUMEN

Soft contact lens discontinuations have a dramatic impact on the overall success of this form of vision correction, and evidence suggests that the reasons for contact lens cessation are different for new wearers than for established lens users. In descending order, these relate to vision, discomfort, handling, inconvenience/loss of interest, ocular health and cost. This paper considers the background and underlying evidence for these causes of soft lens discontinuation in new wearers, and presents clinical management strategies to minimise this phenomenon. Such measures can reasonably be expected to significantly reduce the number of contact lens discontinuations leading to happier patients, increased satisfaction for eye care professionals (ECPs), and greater success for both individual practices and the contact lens industry more broadly.


Asunto(s)
Lentes de Contacto Hidrofílicos , Humanos , Visión Ocular , Satisfacción del Paciente
14.
Transl Vis Sci Technol ; 12(2): 9, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36749580

RESUMEN

Purpose: To develop and evaluate a custom imaging system to provide high-resolution, wide depth-of-field, reflection-free, multispectral infrared (IR) imaging of the Meibomian glands. Methods: Lower eyelids of 15 volunteers were everted to obtain multispectral images of the Meibomian glands with custom imaging setup. Photographs were captured at 10 different ISO settings (from underexposure to overexposure) and using nine IR imaging filters (ranging from 600 nm to 1000 nm in 50-nm steps). Meibomian gland contrast (simple and Michelson) was calculated for the images to choose an optimal wavelength for Meibomian gland imaging and to determine differences in contrast across individuals. Results: The overall linear regression model showed a significant effect of wavelength on Meibomian gland contrast (Simple contrast: F = 7.24, P < 0.0001; Michelson contrast: F = 7.19, P < 0.0001). There was a significant negative correlation between Meibomian gland contrast and Meibomian gland depth for 750-nm IR filter (ρs= -0.579; P = 0.026). Conclusions: Meibomian gland contrast varies across individuals and depends on Meibomian gland depth. IR filter of 750 nm is the optimal choice for Meibomian gland imaging because it provides images of greatest contrast. Translational Relevance: This study adds to our understanding of Meibomian gland imaging. It has successfully demonstrated that Meibomian glands that are deeper in the tarsal plate require longer wavelengths for imaging.


Asunto(s)
Glándulas Tarsales , Humanos , Glándulas Tarsales/diagnóstico por imagen
15.
Eye Contact Lens ; 48(11): 455-459, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36083156

RESUMEN

OBJECTIVES: To assess the impact of national affluence on the extent of prescribing of various types of soft contact lenses. METHODS: Using information derived from a large bank of contact lens prescribing data, the relationship between the percentage prescribing of daily disposable, toric, silicone hydrogel, and multifocal contact lenses versus the gross domestic product at purchasing parity per capita (GDP [PPP]) was determined for all countries in which contact lens prescribers returned survey forms relating to greater than 100 contact lens fits between 2017 and 2021, inclusive. RESULTS: Data from 39 countries were analyzed, comprising 94,181 contact lens fits. The relationship between percentage contact lens prescribing versus GDP (PPP) was highly statistically significant for daily disposable lenses (r 2 =0.35, P <0.0001), marginally significant for toric lenses (r 2 =0.08, P =0.06), and not significant for silicone hydrogel lenses (r 2 =0.01, P =0.42) or multifocal lenses (r 2 =0.02, P =0.35). CONCLUSIONS: The rate of prescribing daily disposable contact lenses, and to a lesser extent toric lenses, is related to national affluence. The contact lens industry, practitioners, and governments/regulatory bodies should remain cognizant of this association and, where possible, reduce cost barriers to the purchase of such contact lens products so that they can be prescribed based on important clinical, refraction, and lifestyle considerations.


Asunto(s)
Lentes de Contacto Hidrofílicos , Optometría , Humanos , Prescripciones , Siliconas , Hidrogeles
16.
Int J Mol Sci ; 23(17)2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36077001

RESUMEN

Meibomian gland orifices (MGOs) are located along the eyelid margin and secrete meibum into the tear film. The profile of resident innate immune cells (ICs) at this site is not well understood. The distribution and phenotype of resident ICs around MGOs in mice was investigated and herein defined as MGO-associated immune cells (MOICs). The effect of topical 0.1% benzalkonium chloride (BAK) on MOICs was also assessed. Eyelids from healthy CD11ceYFP and Cx3cr1gfp/gfp mice aged three or seven months were compared. ICs were identified as CD11c+, Cx3cr1+, and MHC-II+ using four-colour immunostaining and confocal microscopy. MOIC density was variable but clustered around MGOs. There were more CD11c+ MOICs in three-month-old compared with seven-month-old mice (three-month-old: 893 ± 449 cells/mm2 vs. seven-month-old: 593 ± 493 cells/mm2, p = 0.004). Along the eyelid margin, there was a decreasing gradient of CD11c+ MOIC density in three-month-old mice (nasal: 1003 ± 369 cells/mm2, vs. central: 946 ± 574 cells/mm2, vs. temporal: 731 ± 353 cells/mm2, p = 0.044). Cx3cr1-deficient mice had two-fold fewer MHC-II+ MOICs, suggesting a role for Cx3cr1 receptor signaling in meibomian gland surveillance. CD11c+ MOIC density was lower in BAK-exposed eyes compared to saline-treated controls, suggesting a change in homeostasis. This study provides novel insight into resident ICs located at MGOs, and their contribution to MG homeostasis.


Asunto(s)
Enfermedades de los Párpados , Glándulas Tarsales , Animales , Compuestos de Benzalconio/farmacología , Ratones , Fenotipo , Lágrimas
17.
Ocul Surf ; 25: 119-128, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35724917

RESUMEN

Meibography is a visualisation technique that has been used for over 40 years. There have been significant improvements in image quality, examination technique and image interpretation over this period. Although meibography has received sporadic reviews in the past, an updated review is timely due to the rapid recent rise of relevant technology and advances in both image processing and artificial intelligence. The primary aim of this paper is to review recent research into Meibomian gland imaging and update the community about the most relevant technologies and approaches used in the field.


Asunto(s)
Síndromes de Ojo Seco , Enfermedades de los Párpados , Inteligencia Artificial , Síndromes de Ojo Seco/diagnóstico , Enfermedades de los Párpados/diagnóstico , Humanos , Procesamiento de Imagen Asistido por Computador , Glándulas Tarsales/diagnóstico por imagen , Lágrimas
18.
Clin Exp Optom ; 105(5): 457-458, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35772933
19.
Cont Lens Anterior Eye ; 45(5): 101596, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35466057

RESUMEN

PURPOSE: The aim of this pilot study was to investigate the initial effect of contact lens wear on spontaneous blink characteristics. METHODS: This was a randomised, crossover pilot study. Spontaneous blinking was recorded using a high-speed infrared camera in ten subjects with three different soft contact lenses (spherical hydrogel, spherical silicone hydrogel and toric hydrogel), one rigid contact lens and without contact lenses. Custom semi-automated software was used to determine palpebral aperture height, interblink interval (IBI), blink speed, blink completeness and blink duration. RESULTS: The IBI was significantly greater for non-lens wear compared with the silicone hydrogel [ratio (95% CI): 1.34 (1.16, 1.55), p < 0.0001], toric hydrogel [1.28 (1.10, 1.48), p = 0.0001] and rigid corneal lenses [1.48 (1.27, 1.73), p < 0.0001]. The spherical silicone hydrogel lens showed greater closing-phase speed than non-lens wear [mean difference (95% CI): 27.4 (5.6, 49.1) mm/s, p = 0.006]. Shorter total blink duration was found for non-lens wear compared with any of the lens types [spherical hydrogel: ratio 0.89 (0.81, 0.98), p = 0.01; spherical silicone hydrogel: 0.87 (0.80, 0.95), p = 0.0001; toric hydrogel: 0.90 (0.83, 0.98), p = 0.004; and rigid corneal: 0.88 (0.82, 0.96), p = 0.0004]. Opening-phase speed (p = 0.12) and blink completeness metrics (all p > 0.5) were not influenced by wearing condition. CONCLUSION: This work showed that short-term contact lens wear influenced the palpebral aperture height, IBI, speed and duration of the blink, and the effect is dependent on the contact lens type. The completeness of the blink was not altered by contact lens wear. Future work should be conducted to assess the effect of long-term wear of different contact lens types on blink characteristics. The measurement of spontaneous blinking characteristics represents an immediate, sensitive and non-invasive evaluation of the impact of a contact lens on the ocular surface.


Asunto(s)
Parpadeo , Lentes de Contacto Hidrofílicos , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Hidrogeles , Proyectos Piloto , Siliconas
20.
Clin Exp Optom ; 105(3): 298-312, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35184672

RESUMEN

CLINICAL RELEVANCE: Contact lens prescribing data serve as a benchmark for eye care clinicians in assessing their own prescribing patterns and provide useful contextual information for researchers and the contact lens industry. PURPOSE: To document global trends in contact lens prescribing during the first two decades of this century. METHODS: A longitudinal survey of contact lens prescribing was conducted by asking contact lens practitioners to provide 11 items of information from 10 consecutive contact lens fits between January and March each year from 1996 to 2020, inclusive. RESULTS: Data relating to 406,859 contact lens fits were collected from 71 countries between 1996 and 2020, generating 4.5 million data points. Demographic analysis for 61 nations returning ≥100 fits demonstrated that a majority of lenses (65-70%) were fitted to females. The average age of lens wearers was 30.8 ± 13.9 years for males and 32.5 ± 14.3 years for females. Trend analysis of 20 countries returning prescribing data for ≥13 years between 2000 and 2020 revealed the following: increase in the age of lens wearers; dramatic rise in the extent of fitting silicone hydrogel and daily disposable lenses; increased fitting of soft toric and multifocal lenses; increasing proportion of rigid lens fits in specialist (non-spherical) designs; incomplete provision of near contact lens corrections for contact lens wearing presbyopes; ongoing low levels of extended wear fits; and almost exclusive use of multi-purpose care systems. Daily disposable lenses were used for both full-time and part-time wear, whereas rigid and soft reusable lenses were primarily worn full time. CONCLUSIONS: The evolution of international contact lens fitting over the first two decades of this century is documented. The data presented here may assist all stakeholders in advancing contact lens clinical practice, informing contact lens research, and guiding contact lens manufacturers.


Asunto(s)
Lentes de Contacto Hidrofílicos , Lentes de Contacto , Optometría , Adolescente , Adulto , Femenino , Humanos , Masculino , Prescripciones , Siliconas , Encuestas y Cuestionarios , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...