Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36231898

RESUMEN

In 2020, COVID-19 spread throughout the world, and international measures such as travel bans, quarantines, and increased social distancing were implemented. In Japan, the number of infected people increased, and a state of emergency was declared from 16 April to 25 May 2020. Such a change in physical activity could lead to a decline in physical function in people with disabilities. A retrospective study was conducted to determine the impact of the pandemic on the physical function of disabled persons living in the community. Data were collected at four points in time: two points before the declaration of the state of emergency was issued and two points after the declaration period had ended. Time series data of physical function at four points in time were compared for 241 people with disabilities. The mean age was 72.39 years; 157 had stroke, 59 musculoskeletal disease, and 26 other diseases. Overall, there was a long-term decrease in walking speed (p < 0.001) and a worsening of the Timed Up-and-Go (TUG) score (p < 0.001) after the period of the state of emergency. The TUG score worsened only in the group with a walking speed of 1.0 m/s or less before the state of emergency (p = 0.064), suggesting that this group was more susceptible.


Asunto(s)
COVID-19 , Personas con Discapacidad , Anciano , COVID-19/epidemiología , Humanos , Vida Independiente , Japón/epidemiología , Pandemias , Estudios Retrospectivos
2.
Hip Int ; 21(6): 718-23, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22101620

RESUMEN

Adequate fixation at the time of cementless stem implantation depends on the operator's experience. An objective evaluation method to determine whether the stem has been appropriately implanted may be helpful. We studied the relationship between the hammering sound frequency during stem implantation and internal stress in a femoral model, and evaluated the possible usefulness of hammering sound frequency analysis for preventing intraoperative fracture. Three types of cementless stem (BiCONTACT®, SL-PLUS®, and AI-Hip®) were used. Surgeons performed stem insertion using a procedure similar to that employed in a routine operation. Stress was estimated by finite element analysis, the hammering force was measured, and frequency analysis of hammering sound data obtained using a microphone. Finite element analysis showed a decrease in the hammering sound frequency with an increase in the estimated maximum stress. When a decrease in frequency was observed, adequate hammering had occurred, and the continuation of hammering risked fracture. Based on the relationship between stress and frequency, the evaluation of changes in frequency may be useful for preventing the development of intraoperative fractures. Using our method, when a decrease in frequency is observed, the hammering force should be reduced. Hammering sound frequency analysis may allow the prediction of bone fractures that can be visually confirmed, and may be a useful objective evaluation method for the prevention of intraoperative periprosthetic fractures during stem insertion.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/etiología , Prótesis de Cadera , Fracturas Periprotésicas/prevención & control , Falla de Prótesis , Espectrografía del Sonido/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Cementación , Fracturas del Fémur/diagnóstico , Humanos , Complicaciones Intraoperatorias , Periodo Intraoperatorio , Modelos Anatómicos , Fracturas Periprotésicas/diagnóstico , Diseño de Prótesis , Sonido , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA