Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Heliyon ; 9(6): e17310, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37383209

RESUMEN

Objectives: To evaluate the correlation between patient characteristics, operative variables and the risk of blood stream infection as well as the association of primary blood stream infection and adverse outcomes. Methods: Clinical records of 6500 adult patients who underwent open heart surgery between February 2008 and October 2020 were analyzed. The microbiological pattern of the primary BSI and its association with adverse events, such as mortality and major cardiovascular events, were evaluated. Results: Primary bloodstream infection was diagnosed in 1.7% (n = 108) of patients following cardiac surgery with the application of cardiopulmonary bypass. Most isolated bacteria were gram-negative bacillus groups, such as the Enterobacteriaceae family with Serrata marcescens in 26.26%, followed by the Enterococcaceae family with the Enterococcus faecalis in 7.39% and Enterococcus faecium in 9.14% as the most frequently identified bacteria. The postprocedural mortality, stroke rate p < 0.001, the incidence of postoperative new renal failure p < 0.001, and the renal replacement therapy p < 0.001 were significantly higher in the primary BSI group. Aortic cross-clamp time >120 min, OR 2.31 95%CI 1.34 to 3.98, perfusion time >120 min, OR 2.45 95%CI 1.63 to 3.67, and duration of the intervention >300min, OR 2.78 95%CI 1.47 to 5.28, were significantly related to the primary BSI. Conclusion: The gram-negative bacillus was the most common microorganism identified in BSI after cardiovascular operations using cardiopulmonary bypass. Patients on dialysis prior to cardiac surgery are at higher risk for having BSI. Enteric bacterial translocation after prolonged cardiopulmonary bypass is a possible mechanism of early primary bloodstream infection in these patients. In patients at high risk, prophylactic use of an antibiotic regimen with broader gram-negative bacteria coverage should be considered, especially in those with prolonged cardiopulmonary bypass and intervention time.

2.
Bioengineering (Basel) ; 10(2)2023 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-36829650

RESUMEN

Transapical transcatheter aortic valve implantation (TA-TAVI) is generally considered to be associated with increased morbidity and mortality compared with transfemoral transcatheter aortic valve implantation TAVI (TF-TAVI). We aimed to compare different patient risk profiles, access-related complications, and long-term survival using inverse probability treatment weighting. This is a retrospective, single-center analysis of 925 consecutive patients with aortic valve stenosis undergoing TF-TAVI (n = 802) or TA-TAVI (n = 123) at the University Hospital Basel, Switzerland, as a single procedure between September 2011 and August 2020. Baseline characteristics revealed a higher perioperative risk as reflected in the EuroSCORE II (geometric mean 2.3 (95% confidence interval (CI) 2.2 to 2.4) vs. 3.7 (CI 3.1 to 4.5); before inverse probability of treatment weighting (IPTW) p < 0.001) in the transfemoral than in the transapical group, respectively. After 30 days, TF-TAVI patients had a higher incidence of any bleeding than TA-TAVI patients (TF-TAVI n = 146 vs. TA-TAVI n = 15; weighted hazard ratio (HR) 0.52 (0.29 to 0.95); p = 0.032). After 5 years, all-cause mortality did not differ between the two groups (TF-TAVI n = 162 vs. TA-TAVI n = 45; weighted HR 1.31, (0.92 to 1.88); p = 0.138). With regard to our data, we could demonstrate, despite a higher perioperative risk, the short- and long-term safety and efficacy of the transapical approach for TAVI therapies. Though at higher perioperative risk, transapically treated patients suffered from less bleeding or vascular complications than transfemorally treated patients. It is of utmost interest that 5-year mortality did not differ between the groups.

3.
Eur J Heart Fail ; 25(3): 347-357, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36644890

RESUMEN

AIMS: Primary acute heart failure (AHF) is a common cause of hospitalization. AHF may also develop postoperatively (pAHF). The aim of this study was to assess the incidence, phenotypes, determinants and outcomes of pAHF following non-cardiac surgery. METHODS AND RESULTS: A total of 9164 consecutive high-risk patients undergoing 11 262 non-cardiac inpatient surgeries were prospectively included. The incidence, phenotypes, determinants and outcome of pAHF, centrally adjudicated by independent cardiologists, were determined. The incidence of pAHF was 2.5% (95% confidence interval [CI] 2.2-2.8%); 51% of pAHF occurred in patients without known heart failure (de novo pAHF), and 49% in patients with chronic heart failure. Among patients with chronic heart failure, 10% developed pAHF, and among patients without a history of heart failure, 1.5% developed pAHF. Chronic heart failure, diabetes, urgent/emergent surgery, atrial fibrillation, cardiac troponin elevations above the 99th percentile, chronic obstructive pulmonary disease, anaemia, peripheral artery disease, coronary artery disease, and age, were independent predictors of pAHF in the logistic regression model. Patients with pAHF had significantly higher all-cause mortality (44% vs. 11%, p < 0.001) and AHF readmission (15% vs. 2%, p < 0.001) within 1 year than patients without pAHF. After Cox regression analysis, pAHF was an independent predictor of all-cause mortality (adjusted hazard ratio [aHR] 1.7 [95% CI 1.3-2.2]; p < 0.001) and AHF readmission (aHR 2.3 [95% CI 1.5-3.7]; p < 0.001). Findings were confirmed in an external validation cohort using a prospective multicentre cohort of 1250 patients (incidence of pAHF 2.4% [95% CI 1.6-3.3%]). CONCLUSIONS: Postoperative AHF frequently developed following non-cardiac surgery, being de novo in half of cases, and associated with a very high mortality.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Estudios Prospectivos , Incidencia , Enfermedad Aguda , Enfermedad Crónica , Fenotipo
4.
Eur J Heart Fail ; 25(2): 174-184, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36597828

RESUMEN

AIMS: Systemic inflammation may be central in the pathophysiology of acute heart failure (AHF). We aimed to assess the possible role of systemic inflammation in the pathophysiology, phenotyping, and risk stratification of patients with AHF. METHODS AND RESULTS: Using a novel Interleukin-6 immunoassay with unprecedented sensitivity (limit of detection 0.01 ng/L), we quantified systemic inflammation in unselected patients presenting with acute dyspnoea to the emergency department in a multicentre study. One-year mortality was the primary prognostic endpoint. Among 2042 patients, 1026 (50.2%) had an adjudicated diagnosis of AHF, 83.7% of whom had elevated interleukin-6 concentrations (>4.45 ng/L). Interleukin-6 was significantly higher in AHF patients compared to patients with other causes of dyspnoea (11.2 [6.1-26.5] ng/L vs. 9.0 [3.2-32.3] ng/L, p < 0.0005). Elevated interleukin-6 concentrations were independently predicted by increasing N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin T, as well as the clinical diagnosis of infection. Among the different AHF phenotypes, interleukin-6 concentrations were highest in patients with cardiogenic shock (25.7 [14.0-164.2] ng/L) and lowest in patients with hypertensive AHF (9.3 [4.8-21.6] ng/L, p = 0.001). Inflammation as quantified by interleukin-6 was a strong and independent predictor of 1-year mortality both in all AHF patients, as well as those without clinically overt infection at presentation (adjusted hazard ratio [95% confidence interval] 1.45 [1.15-1.83] vs. 1.48 [1.09-2.00]). The addition of interleukin-6 significantly improved the discrimination of the BIOSTAT-CHF risk score. CONCLUSION: An unexpectedly high percentage of patients with AHF have subclinical systemic inflammation as quantified by interleukin-6, which seems to contribute to AHF phenotype and to the risk of death.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Enfermedad Aguda , Biomarcadores , Disnea , Insuficiencia Cardíaca/diagnóstico , Inflamación , Interleucina-6 , Pronóstico , Estudios Prospectivos , Medición de Riesgo
5.
ESC Heart Fail ; 9(4): 2703-2712, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35438261

RESUMEN

AIMS: New-onset atrial fibrillation (NOAF) is the most common complication after cardiac surgery, occurring in 25-50% of patients. It is associated with post-operative stroke, increased mortality, prolonged hospital length of stay, and higher treatment costs. Previous small observational studies have identified the left atrium as a source of the electrical rotors and foci maintaining NOAF, but confirmation by a large prospective clinical study is still missing. The aim of the proposed study is to investigate whether the source of NOAF lies in the left atrium. The correct identification of NOAF-maintaining structures in cardiac surgical patients might offer potential therapeutic targets for prophylactic perioperative ablation strategies. METHODS AND RESULTS: This is a prospective single-centre observational study of patients developing NOAF after cardiac surgery. The primary outcome is the description of NOAF-maintaining structures within the atria. Key secondary outcomes include overall mortality, intensive care unit length of stay, hospital-ventilator-free days, and proportion of persistent NOAF. In NOAF patients, the non-invasive electrophysiological mapping will be conducted using a 252-electrode electrocardiogram vest. After mapping, a low-dose computed tomography scan of the chest will be performed to integrate the electrophysiological mapping results into a 3D picture of the heart. The study will include approximately 570 patients, of whom 30% (n = 170) are expected to develop NOAF. Sample size calculation revealed that 157 NOAF patients are necessary to assess the primary outcome. Patients will be tracked for a total of 5 years. CONCLUSIONS: This is the largest prospective study to date describing the electrophysiological mechanisms of NOAF using non-invasive mapping.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Electrocardiografía , Humanos , Estudios Observacionales como Asunto , Estudios Prospectivos , Factores de Riesgo
6.
Perfusion ; 37(8): 773-784, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34112048

RESUMEN

OBJECTIVES: The main aim was a systematic evaluation of the current evidence on outcomes for patients undergoing right ventricular assist device (RVAD) implantation following left ventricular assist device (LVAD) implantation. METHODS: This systematic review was registered on PROSPERO (CRD42019130131). Reports evaluating in-hospital as well as follow-up outcome in LVAD and LVAD/RVAD implantation were identified through Ovid Medline, Web of Science and EMBASE. The primary endpoint was mortality at the hospital stay and at follow-up. Pooled incidence of defined endpoints was calculated by using random effects models. RESULTS: A total of 35 retrospective studies that included 3260 patients were analyzed. 30 days mortality was in favour of isolated LVAD implantation 6.74% (1.98-11.5%) versus 31.9% (19.78-44.02%) p = 0.001 in LVAD with temporary need for RVAD. During the hospital stay the incidence of major bleeding was 18.7% (18.2-19.4%) versus 40.0% (36.3-48.8%) and stroke rate was 5.6% (5.4-5.8%) versus 20.9% (16.8-28.3%) and was in favour of isolated LVAD implantation. Mortality reported at short-term as well at long-term was 19.66% (CI 15.73-23.59%) and 33.90% (CI 8.84-59.96%) in LVAD respectively versus 45.35% (CI 35.31-55.4%) p ⩽ 0.001 and 48.23% (CI 16.01-80.45%) p = 0.686 in LVAD/RVAD group respectively. CONCLUSION: Implantation of a temporary RVAD is allied with a worse outcome during the primary hospitalization and at follow-up. Compared to isolated LVAD support, biventricular mechanical circulatory support leads to an elevated mortality and higher incidence of adverse events such as bleeding and stroke.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Derecha , Humanos , Corazón Auxiliar/efectos adversos , Disfunción Ventricular Derecha/etiología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Hemorragia/etiología
7.
CJC Open ; 3(10): 1313-1315, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34888513

RESUMEN

A 70-year-old female heart failure patient could not be weaned from temporary left ventricular mechanical support with Impella CP (Abiomed Inc, Danvers, MA) after myocardial infarction; therefore, she underwent left ventricular assist device implantation (HeartMate 3; Abbott, Chicago, IL). After uneventful surgery, the patient had an early postoperative thrombus in the aortic root, and surgical thrombectomy on extracorporeal circulation was performed on the seventh postoperative day. The patient recovered well and presented in good condition with no neurologic symptoms at the 6-month follow-up visit. Surgical excision of aortic root thrombus is a feasible option even for frail patients with a left ventricular assist device.


Après un infarctus du myocarde, une patiente de 70 ans présentant une insuffisance cardiaque n'a pas pu être sevrée d'une assistance mécanique temporaire pour le ventricule gauche par dispositif Impella CP (Abiomed Inc, Danvers, MA); elle a donc subi l'implantation d'un dispositif d'assistance ventriculaire gauche (HeartMate 3; Abbott, Chicago, IL). Après une intervention sans incident, la patiente a présenté un thrombus postopératoire précoce dans l'anneau aortique, et une thrombectomie chirurgicale sous circulation extracorporelle a été réalisée le septième jour suivant l'intervention. La patiente s'est bien rétablie et semblait en bonne santé, sans symptômes neurologiques, au moment de la visite de suivi six mois plus tard. L'excision chirurgicale du thrombus de l'anneau aortique est une option réaliste même chez les patients fragiles ayant un dispositif d'assistance ventriculaire gauche.

8.
J Cardiothorac Surg ; 16(1): 64, 2021 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-33789723

RESUMEN

BACKGROUND: In Switzerland, long-term circulatory support programs have been limited to heart transplant centers. In 2014, to improve the management of patients with end-stage heart failure not eligible for transplantation, we implemented a left ventricular assist device (LVAD) program for destination therapy at the University Hospital of Basel. METHODS: We described the program set-up with practical aspects. Patients aged 65 and above with therapy refractory end-stage heart failure without major contraindication for LVAD implantation were included. Younger patients with bridge-to-candidacy profile were also considered. Using the Kaplan-Meier estimate, we retrospectively analyzed the overall survival and freedom from major adverse events after LVAD implantation. We compared our results to internationally reported data. RESULTS: Between October 2014 and September 2019, 16 patients received an LVAD in our center. The mean age at implantation was 67.1 years. The mean EuroSCORE II was 24.4% and the median INTERMACS level was 4. Thirteen patients received an LVAD as destination therapy and three patients as bridge-to-candidacy. The overall survival was 87.5 and 70% at 1 and 2 years, respectively. Freedom from stroke was 81.3% at 1 and 2 years. Freedom from device infection was 67.7 and 58.7% at 1 and 2 years, respectively. Freedom from gastrointestinal bleeding was 75 and 56.3% at 1 and 2 years, respectively. Freedom from readmission was 50 and 31.3% and at 6 months and 1 year, respectively. CONCLUSIONS: The Basel experience demonstrated the possible implementation of an LVAD program for destination therapy or bridge-to-candidacy in a non-transplant comprehensive heart-failure center with midterm survival results and freedom from major adverse events comparable to international registries. Patient selection remains crucial. TRIAL REGISTRATION: This study was registered on the ClinicalTrials.gov database ( NCT04263012 ).


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Anciano , Femenino , Estudios de Seguimiento , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Hospitales Universitarios , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Estudios Retrospectivos , Accidente Cerebrovascular/prevención & control , Suiza
9.
Case Rep Cardiol ; 2021: 6651361, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33728072

RESUMEN

In March 2020, a 64-year-old female with mitral valve insufficiency and persistent atrial fibrillation underwent preoperative noninvasive mapping for developing an ablation strategy. In the computed tomography (CT) scan, typical signs of COVID-19 were described. Since the consecutive polymerase chain reaction (PCR) test was negative, the severely symptomatic patient was planned for urgent surgery. Noninvasive mapping showed that atrial fibrillation was maintained by left atrial structures and pulmonary veins only. On admission day, the preoperative routine COVID-19 PCR test was positive, and after recovery, uneventful mitral valve repair with cryoablation of the left atrium and pulmonary veins was performed. Our case describes the potential benefit of preoperative noninvasive mapping for the development of a surgical ablation strategy, as well as the challenges in managing urgent surgical patients during the COVID-19 pandemic and the corresponding diagnostic relevance of CT.

10.
J Int Med Res ; 49(2): 300060520986710, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33535858

RESUMEN

We report a bail out approach of endovascular thoracic aorta repair following incorrect deployment of a modified frozen elephant trunk stent graft into the false lumen. A 76-year-old patient was admitted to our Emergency Department. A computed tomography angiography scan showed type I DeBakey aortic dissection. An emergency modified frozen elephant trunk procedure was performed. Immediate postoperative computed tomography angiography showed that the distal segment of the stent was deployed in the false lumen, probably through a re-entry tear at the descending thoracic aorta. Emergency endovascular repair of the thoracic aorta, as well as angioplasty of the superior mesenteric artery and left iliac artery, were performed.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Humanos , Stents , Resultado del Tratamiento
11.
Mediators Inflamm ; 2019: 5648051, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31885497

RESUMEN

BACKGROUND: Single-dose cardioplegia is preferred in minimal invasive mitral valve surgery to maintain the adjustment of the operative site without change of preset visualization. The aim of our study was to compare two widely used crystalloid cardioplegias Bretschneider (Custodiol®) versus St. Thomas 2 in patients who underwent mitral valve repair via small anterolateral right thoracotomy. MATERIAL AND METHODS: From May 2012 until February 2019, 184 isolated mitral valve procedures for mitral valve repair via anterolateral right thoracotomy were performed using Bretschneider (Custodiol®) cardioplegia (n = 123) or St. Thomas (n = 61). Primary efficacy endpoint was peak postoperative high-sensitivity cardiac troponin (hs-cTnT) during hospitalization. Secondary endpoints were peak creatine kinase-muscle brain type (CK-MB) and creatine kinase (CK) as well as safety outcomes. We used inverse probability of treatment weighting (IPTW) in order to adjust for confounding by indication. RESULTS: Peak hs-cTnT was higher after use of Bretschneider (Custodiol®) (geometric mean 716 mg/L, 95% confidence interval (CI) 605-847 mg/L) vs. St. Thomas 2 (561 mg/L, CI 467-674 mg/L, p = 0.047). Peak CK-MB (geometric mean after Bretschneider (Custodiol®): 40 µg/L, CI 35-46, St. Thomas 2: 33 µg/L, CI 27-41, p = 0.295) and CK (geometric mean after Bretschneider (Custodiol®): 1370 U/L, CI 1222-1536, St. Thomas 2: 1152 U/L, CI 972-1366, p = 0.037) showed the same pattern. We did not see any difference with respect to postoperative complications between treatment groups after IPTW. CONCLUSION: Use of St. Thomas 2 cardioplegia was associated with lower postoperative peak levels of all cardiac markers that reflect cardiac ischemia such as hs-cTnT, CK, and CK-MB as compared to Bretschneider (Custodiol®) in propensity-weighted treatment groups.


Asunto(s)
Soluciones Cardiopléjicas/uso terapéutico , Válvula Mitral/efectos de los fármacos , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Soluciones Cardiopléjicas/efectos adversos , Intervalos de Confianza , Femenino , Glucosa/efectos adversos , Glucosa/uso terapéutico , Corazón/efectos de los fármacos , Humanos , Masculino , Manitol/efectos adversos , Manitol/uso terapéutico , Persona de Mediana Edad , Válvula Mitral/metabolismo , Válvula Mitral/cirugía , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/prevención & control , Miocardio/metabolismo , Cloruro de Potasio/efectos adversos , Cloruro de Potasio/uso terapéutico , Procaína/efectos adversos , Procaína/uso terapéutico , Toracotomía/métodos
12.
J Cardiothorac Surg ; 14(1): 121, 2019 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-31253165

RESUMEN

BACKGROUND: Pacemaker implantation techniques using thoracoscopy have been described since about 25 years. However, the published reports concerning types of electrodes refer mostly to monopolar screw-in leads. We report our experience of thoracoscopic implantation of a bipolar suture-on epicardial electrode with monofilamentous sutures tightened by automated fasteners to avoid hand-tied knots. CASE PRESENTATION: A 69-year-old Caucasian female patient with a cardiac resynchronization therapy - defibrillator (CRT-D) due to dilated cardiomyopathy required the implantation of a supplementary left ventricluar resynchronization electrode. Because of unfavorable venous access, we chose a thoracoscopic approach. A bipolar suture-on epicardial electrode, was implanted by means of polypropylene monofilament 2-0 threads and automated titanium fasteners (Cor-Knot®). The intervention was uneventful. The correct function of the device was confirmed postoperatively and the patient was dismissed within 3 days from hospital. Six months after implantation the cardiologic control asserted regular device function and restitution of normal ejection fraction (EF 60%). CONCLUSION: This case demonstrates the feasibility, safety and effectiveness of automated fasteners in the setting of thoracoscopic implantation of epicardial bipolar suture-on leads.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Cardiomiopatía Dilatada/terapia , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Técnicas de Sutura/instrumentación , Toracoscopía/métodos , Titanio , Anciano , Femenino , Humanos , Suturas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...