Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Robot Surg ; 18(1): 73, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38349425

RESUMEN

Partial nephrectomy (PN) represents a procedure where the use of a robot has further enabled successful completion of this complex surgery. The results of this procedure using Versius Robotic Surgical System (VRSS) still need to be evaluated. Our working group described the technique and reported the initial results of a series of PN using VRSS. We presented our setting, surgical technique and outcomes for PN, using VRSS. Between 2022 and 2023, 15 patients underwent PN performed by two surgeons in two different centers. Fifteen patients underwent PN. The median lesion size identified on preoperative imaging was 4 (IQR 2.3-5) cm. Median PADUA score was 8 (IQR 7-9). Two procedures were converted to radical nephrectomy for enhanced oncological disease control. Of the 13 nephrectomies that were completed as partial, 7 were performed clampless and 6 with warm ischemia clamping. Median clamping time was 10 (IQR 9-11) minutes. No procedure was converted to open. Median blood loss was 200 (IQR 100-250) mL. Median total operative time was 105 (IQR 100-110) minutes. Median console time was 75 (IQR 66-80) minutes. Median set-up time was 13 (IQR 12-14) minutes. No intraoperative complications were reported. The median hospitalization time was 4 (IQR 3.5-4) days. None of the patients were transfused and none of the patients required readmission. In a pathology report, one patient had a positive surgical margin. Our initial experience suggests that performing PN using VRSS is feasible with good short-term outcomes.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Cirujanos , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Complicaciones Intraoperatorias , Nefrectomía , Tempo Operativo
3.
World J Urol ; 42(1): 31, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217724

RESUMEN

INTRODUCTION: Versius CMR is a novel robotic system characterized by an open surgical console and independent bedside units. The system has potentials of flexibility and versatility, and has been used in urological, gynecological, and general surgical procedure. The aim is to depict a comprehensive analysis of the Versius system for pelvic surgery. METHODS: This is a study involving two Institutions, ASST Santi Paolo and Carlo, Milan, and Apuane Hospital, Massa, Italy. All interventions performed in the pelvic area with the Versius were included. Data about indications, intra-, and post-operative course were prospectively collected and analyzed. RESULTS: A total of 171 interventions were performed with the Versius. Forty-two of them involved pelvic procedures. Twenty-two had an oncological indication (localized prostate cancer), the remaining had a non-oncological or functional purpose. The mostly performed pelvic procedure was radical prostatectomy (22) followed by annexectomy (9). No intra-operative complication nor conversion to other approaches occurred. A Clavien II complication and one Clavien IIIb were reported. Malfunctioning/alarms requiring a power cycle of the system occurred in 2 different cases. An adjustment in trocar placement according to patients' height was required in 2 patients undergoing prostatectomy, in which the trocar was moved caudally. In two cases, a pelvic prolapse was repaired concomitant with other gynecological procedures. CONCLUSIONS: Pelvic surgery with the Versius is feasible without major complications; either dissection and reconstructive steps could be accomplished, provided a proper OR setup and trocar placement are pursued. Versius can be easily adopted by surgeons of different disciplines and backgrounds; a further multi-specialty implementation is presumed and long-term oncological and functional outcomes are awaited.


Asunto(s)
Procedimientos de Cirugía Plástica , Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Masculino , Humanos , Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Cuidados Preoperatorios
4.
BJU Int ; 133(2): 197-205, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37604773

RESUMEN

OBJECTIVE: To present the results of the first series of patients treated with robot-assisted radical prostatectomy (RARP) with the use of the Versius® Surgical System (CMR Surgical Ltd., Cambridge, UK). RARP has demonstrated better perioperative outcomes compared to open RP. However, RARP remains limited by platform availability and cost-effectiveness issues. The increasing competition from new robotic surgical platforms may further drive utilisation of the robotic approach. PATIENTS AND METHODS: Data were collected prospectively for our first 18 consecutive patients with localised prostate cancer who underwent RARP at our centre over a 3-month period. We recorded parameters, including patient demographics and perioperative outcomes. We also report our optimised set-up with regard to trocar placement, bedside unit placement, and overall composition of the operating room for this procedure. Describing the incremental modifications carried out to achieve reductions in set-up and operating times to optimise utilisation of the Versius system. RESULTS: The median (interquartile range [IQR]) set-up time was 8.5 (7-10) min. The median (IQR) console time was 201 (170-242) min. The median (IQR) operative time was 213 (186-266) min. The median (IQR) total surgery time was 226 (201-277) min. Bilateral pelvic lymphadenectomy median (IQR) time was 19 (17-20) min. There were no complications and/or limitations related to the use of the Versius system including need for conversion. There were no relevant intra- or postoperative complications at the 1-month follow-up related to the use of the Versius system. Patients were discharged after a median (IQR) of 4 (3.75-5) days, and the transurethral catheter was removed after a mean (range) of 8 (7-14) days. Continence at 2 months was achieved in 72.2% of the patients. CONCLUSIONS: Performing RARP using the Versius system is feasible, safe, and easily reproducible. Our set-up enables a rapid docking approach and efficient completion of the surgery.


Asunto(s)
Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Robótica , Masculino , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Próstata/cirugía , Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/etiología , Resultado del Tratamiento
5.
Urol Ann ; 15(2): 238-241, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37304515

RESUMEN

A 85-year-old female patient underwent nephrostomy tube insertion for a huge hydronephrosis due to a papillary mass involving the right ureteral ostium diagnosed by at computed tomography scan. As soon as the nephrostomy tube was inserted, a pulsatile bleeding was found and a renal angiography was done. A massive bleeding from the main and unique right renal artery was found such as to require prompt endovascular embolization. A transurethral resection of the bladder was performed and the pathology report confirmed high-grade pTa transitional cell carcinoma. An open drainage was then placed to empty the contents of the pyelocalyceal system of the kidney. Once obtained the volumetric reduction of the abdominal mass the patient underwent the right nephroureterectomy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...